Quench Analysis in HTS Pancake Coil (고온 초전도체 팬케이크 코일의 퀜치 해석)

  • Park, C.S.;Ahn, T.K.;Park, K.W.;Kim, D.H.;Cha, G.S.;Seo, J.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.6-9
    • /
    • 2009
  • The thermal characteristics of quench propagation is a crucial problem for the stability of the superconductor. The objective of this study is to simulate the quench propagation with the variation of disturbance energy in Bi-2223/Ag HTS pancake coil. In this analysis, the temperature-time trace of a point away from heater was calculated under conditions of different quench energy. The critical disturbance energy between quench propagation and quench recovering was calculated, In addition, the minimum quench energy with different transport currents was obtained through the present simulation. These results are significant to the application of HTS.

Breakdown Characteristics of Liquid Nitrogen Induced by Quench (Quench에 의해 유도되는 액체 $N_2$의 절연파괴 특성)

  • Kim, Yeong-Seok;Jeong, Jong-Man;Gwak, Min-Hwan;Jeong, Sun-Yong;Kim, Sang-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.1
    • /
    • pp.23-28
    • /
    • 1999
  • Electrical breakdown characteristics of liquid nitrogen($LN_2$) used as both coolant and insulator for high $T_c$ superconductor system are very important. This paper presents dynamic breakdown characteristics fo $LN_2$ by quench phenomena of thermal bubble under high electric field. Experimental results revealed dynamic breakdown voltage fell down drastically compared with the static breakdown voltage without the quench. Because of increasing heat power, bubble size becomes big and breakdown voltage decreases. The breakdown voltage mechanism of $LN_2$ depends on thermal bubble effect. In the Electrode arrangement, electrical breakdown voltage of horizontal arrangement appears lower than that of vertical arrangement. Also, we observed the behavior of thermal bubbles in $LN_2$ which were generated after quench using camera.

  • PDF

Quench Analysis and Operational Characteristics of the Quench Detection System for the KSTAR PF Superconducting Coils (펄스전류 운전에 따른 KSTAR PF 초전도자석의 퀜치 분석 및 퀜치 검출 시스템 운전 특성)

  • Chu, Y.;Yonekawa, H.;Kim, Y.O.;Park, K.R.;Lee, H.J.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.20-25
    • /
    • 2009
  • The quench detection system of the KSTAR (Korea Superconducting Tokamak Advanced Research) primarily uses the resistive voltage measurement due to a quench. This method is to detect the resistive voltage generated by a quench, which is continuously maintained above the preset voltage threshold for a given holding time. As the KSTAR PF (Poloidal Field) coils are operated in the pulse current mode, the large inductive voltages are generated. Therefore the voltage threshold and the quench holding time should be determined by considering both the inductive voltages measured during the operation, and the maximum conductor temperature rise through the quench analysis. In this paper, the compensation methods for minimizing the inductive voltages are presented for the KSTAR PF coils. The quench hot spot analysis of the PF coils was carried out by the analytical and numerical methods for determining the proper values of the quench voltage threshold and the allowable quench protection delay time.

Quench Characteristics of Field Winding in a superconducting Generator Using 2-Dimensional Analysis (2차원 해석을 이용한 초전도 발전기 계자 코일의 퀜치 특성)

  • 강준선;나완수;최세용;권영길;손명환;류강식
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.177-179
    • /
    • 2000
  • In this paper, we analyzed quench characteristics of field windings using 2 dimensional analysis. The quench origin was assumed to take place at the inner most point in the mid-plane of the coil. The temperature distribution was numerically calculated on the coil cross section using FDM analysis, and was used to estimate the normal zone resistance of the coil. Finally, we obtained voltage current characteristics of the quenched winding coils.

  • PDF

Quench Characteristics of Superconducting Elements using Reactors at Series and Parallel Connections (직·병렬연결시 리액터를 이용한 초전도 소자의 퀜치 특성)

  • Choi, Hyo-Sang;Lim, Sung-Hun;Cho, Yong-Sun;Nam, Gueng-Hyun;Lee, Na-young;Park, Hyoung-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.9
    • /
    • pp.863-869
    • /
    • 2005
  • We investigated quench characteristics of superconducting elements connected in series and parallel each other. The serial and parallel connections of superconducting elements causes a difficulty in simultaneous quench due to slight difference between their critical current densities. In other to induce simultaneous quench, we fabricated four type circuits; serially connected circuit before parallel connection, the circuit connected in parallel before serial connection, serially connected circuit before parallel connection with reactors, the circuit connected in Parallel before serial connection with reactors. We confirmed that the simultaneous quenches occurred in serial and parallel connections of superconducting elements using reactors. In addition, the power burden of superconducting elements was smaller than those of serial and parallel connections of superconducting elements without reactors.

Analysis on Fault Current Limiting Characteristics of Three-Phase Transformer Type SFCL using Double Quench According to Three-Phase Ground-Fault Types (이중퀜치를 이용한 삼상변압기형 초전도한류기의 삼상지락 고장 종류에 따른 고장전류 제한 특성 분석)

  • Shin-Won Lee;Tae-Hee Han;Sung-Hun Lim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.614-619
    • /
    • 2023
  • The fault current limiting characteristics of three-phase transformer type superconducting fault current limiter (SFCL), which consisted of three-phase primary and secondary windings wound on E-I iron core, one high-TC superconducting (HTSC) element connected with the secondary winding of one phase and another HTSC element connected in parallel with other two secondary windings of two phases, were analyzed. Unlike other three-phase transformer type SFCLs with three HTSC elements, three-phase transformer type SFCL using double quench has the merit to perform fault current limiting operation for three-phase ground faults with two HTSC elements. To verify its proper three-phase ground fault current limiting operation, three-phase ground faults such as single-line ground, double-line ground and triple-line ground faults were generated in three-phase simulated power system installed with three-phase transformer type SFCL using double quench. From analysis of its fault current limiting characteristics based on tested results, three-phase transformer type SFCL using double quench was shown to be effectively operated for all three-phase ground faults.

Stability of the Cable-in-Conduit Conductors (CIC 초전도 도체의 안정성)

  • 류경우
    • Electrical & Electronic Materials
    • /
    • v.10 no.9
    • /
    • pp.895-900
    • /
    • 1997
  • A Quench in cable-in-conduit (CIC) conductors is often initiated by a disturbance such as strand motion that generates a highly localized normal zone in a strand or a few strands of the CIC conductors. The localized normal zone causes current and heat transfer between a disturbed strand and neighboring strands. Electrical and thermal contact characteristics between strands thus have an effect on the transient stability of the CIC conductors. In this paper the effect of contact characteristics between strands on the CIC conductor stability is presented based on the measured heat transfer characteristics of supercritical helium (SHe) for the local heating. The quench and recovery processes of the strands for the abrupt and highly localized disturbance are analyzed at the boundary between quench and recovery.

  • PDF

Quench characteristic of flux-lock type HTSC FCL (자속구속형 고온초전도 전류제한기의 퀜치특성)

  • Lim, Sung-Hun;Choi, Hyo-Sang;Kang, Hyeong-Gon;Ko, Seok-Cheol;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.77-79
    • /
    • 2003
  • The quench characteristics of flux-lock type high-Tc superconducting fault current limiters(SFCL) was investigated. $YBa_2Cu_3O_{7-x}$(YBCO) thin film was used as the current limiting elements of the flux-lock type SFCL. The quench characteristics of current limiting elements consisting of the flux-lock type SFCL was more improved than that of the resistive type SFCL.

  • PDF

Analysis on Quench Propagation Charactreristics of HTS Tape (고온초전도 테이프 선재의 \ulcorner치 전파 특성 해석)

  • 이지광;김지훈;류경우;차귀수;한송엽
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.1
    • /
    • pp.36-39
    • /
    • 2000
  • The main issues for the power application of high Tc superconducting tape are lower AC loss and higher stability conditions. HTS tape has large stability margin by high heat capacity of superconductor itself and high temperature margin. But, it can be damaged by continuous heat generation at quench point, because normal zone propagation velocity by generating heat is very low. Here, we analyze the quench propagation characteristics using finite element method for BSCCO-2223 HTS tape.

  • PDF

Quench characteristics of YBCO thin films using magnetic field source for superconducting fault current limiters

  • Lee, B.W.;Park, K.B.;Kang, J.S.;Oh, I.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.11-14
    • /
    • 2004
  • YBCO thin films have good characteristics for current limiting materials due to compact size and high current carrying capability. But the irregularities and the extreme thin thickness of YBCO films cause some difficulties in simultaneous quench and thermal shock protection. In order to solve these problems, vertical magnetic field generated from solenoid coil was applied to the YBCO element. And also to minimize the inductance caused by the serial connection of magnetic field source with superconducting elements, magnetic field source was separated from the power lines adapting protective current transformer. In this study, electric field-current (E-I) and quench characteristics of YBCO films were analyzed both by electrical measuring method and observations of bubble propagation. From the experiment results, it was revealed that the magnetic fields generated by surrounding coil could induce the uniform quench distribution for all stripes of current limiting units and finally simultaneous quenches were realized in all serial connection of YBCO elements. In addition, the separation of magnetic field source form electrical network could be good solution for simultaneous quench of YBCO films without any unnecessary effect caused by serial connection.