• 제목/요약/키워드: Quantity of Light

검색결과 279건 처리시간 0.028초

Water Injection/Urea SCR System Experimental Results for NOx Reduction on a Light Duty Diesel Engine

  • Nam, Jeong-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.394-403
    • /
    • 2008
  • The effects of water injection (WI) and urea injection for NOx on a 4-cylinder Direct Injection (DI) diesel engine were investigated experimentally. For water injection, it was installed at the intake pipe and the water quantity was controlled at the intake manifold and Manifold Air Flow (MAF) temperatures while the urea injection was located at the exhaust pipe and the urea quantity was controlled by NOx quantity and MAF. The effects of WI system, urea-SCR system and the combined system were investigated with and without exhaust gas recirculation (EGR). Several experiments were performed to characterize the urea-SCR system, using engine operating points of varying raw NOx emissions. The results of the Stoichiometric Urea Flow (SUF) and NOx map were obtained. In addition, NOx results were illustrated according to the engine speed and load. It is concluded that the NOx reduction effects of the combined system without the EGR were better than those with the EGR-based engine.

Silicate 형광체 증가에 대한 발광 특성 및 신뢰성 분석 (Analysis for luminescence property about an increase quantity of silicate phosphor and reliability)

  • 윤양기;장중순
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제12권4호
    • /
    • pp.275-285
    • /
    • 2012
  • This paper presents a changes of luminescence property for converted white LEDs with the commercially available silicate phosphor. If silicate phosphor's quantity increase step by step. luminescence property will be changing. we analyze luminescence property for these change and carry out the high temperature aging test for 7,000 hours, the high temperature and humidity aging test for 7,000 hours for reliability. LED degradation not only results in reduced light output but also in color changes. so we monitor correlated color temperature (CCT), chromaticity coordinates(x, y) and spectrum intensity. Those results suggest that humidity factor more bad effect in color changes than temperature factor and Lighting quality is related with quantity of phosphor.

경량골재를 사용한 경량콘크리트의 펌프압송 성능향상에 관한 실험적 연구 (The Experimental Study on improvement the pump sending of the light weight concrete using the light weight aggregate)

  • 박대오;서치호;지석원;이진우;신상태;지석원
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 춘계학술논문 발표대회 제6권1호
    • /
    • pp.23-26
    • /
    • 2006
  • The study about the concrete to use recently a light weight aggregate, processed actively. And concrete pumping with a high pressure pump has been popularized, the mechanical development, such as high pressure pumps or pipes, is progressing rapidly. Concrete placing by pumping has the advantage of the reduction of the construction period with workability, easiness of work and the increase of placing, but the quality variation of concrete is caused by pumping is seldom considered, including the increase of the pipe length by high-rising and large-sizing, there by the loss of the unit quantity of water, with pumpability or workability deteriorated. In this research, we will compare and analyze before pumping and after pumping samples of ready-mixed light weight concrete. The result of study as follow. The case of a light weight concrete which the low slump is more decrement compared with high slump light weight concrete in after pumping samples. After pumping the water by pressure of a pump was absorbed to the aggregate inside, and it showed an increase of compression strength about $5{\sim}20%$.

  • PDF

A Study of the Optical Properties of Cosmetics Measured by Polarized Light Goniophotometry

  • Choi, Sun Kyung;Yang, Young Jun;Kim, Kyung Nam;Choi, Jaewook;Choi, Yeong Jin;Han, Sang Hoon
    • Journal of the Optical Society of Korea
    • /
    • 제16권1호
    • /
    • pp.36-41
    • /
    • 2012
  • Polymethylmethacrylate powders are commonly used to improve the spreadability and blurring effects of powder foundation cosmetics. In this study, the opacity and haze effect of four types of polymethylmethacrylate powders and their 10wt% powder foundation formulation was evaluated. The distorted random hemispherical particulates with both concave and convex portions showed the highest haze and opacity value as a single powder substance. And as a formulated phase, the powder foundation formulation containing particulates with fine pores provided the highest haze and opacity value. We also examined the quantity of reflected light over the angular range $20-75^{\circ}$ by polarized light goniophotometry. The total reflected light intensity, surface-reflected light, and internally reflected light were characterized. These studies demonstrated that hemispherical PMMA powders produce natural brilliance by creating high internally reflected light which is similar to the total reflection profile of artificial skin.

고함량 사포나린 함유 보리 어린 순 재배를 위한 식물공장내 인공광 조건 및 사포나린 추출 분석법 최적화 (Optimization of the extraction procedure for quantitative analysis of saponarin and the artificial light condition for saponarin production from barley sprout)

  • 오경열;송영훈;이득영;이태근;김진효
    • Journal of Applied Biological Chemistry
    • /
    • 제64권3호
    • /
    • pp.197-203
    • /
    • 2021
  • 본 연구에서는 보리 어린 순의 기능성 성분인 saponarin의 정량적 추출을 위한 최적의 추출 분석 조건을 methanol, ethanol, acetonitrile 및 water를 대상으로 반응표면분석법을 통해 실시하였다. 이를 통해 용매의 농도, 추출 시간에 따른 saponarin과 색소 추출율을 확인한 결과, 53.7% methanol 수용액에서 3.9 h 동안 진탕추출하는 것이 높은 saponarin 추출율을 유지하면서, 불필요한 색소의 추출을 최소화하는 최적 추출조건으로 확인되었다. 보리 어린 순의 재배에 필요한 인공광의 saponarin 생성 영향 평가를 광 주기, 광량, 광질을 달리한 조건에서 시험한 결과, saponarin 고함유 보리 어린 순의 인공광 최적 재배 조건은 8 h day-1의 광 주기에서 6500K LED와 적색보광을 통한 총 광량 220-320 μmol m-2 s-1 에서 가장 효과적임을 확인 할 수 있었고, 청색광이 saponarin 생합성에 주요 인자로 작용함을 확인할 수 있었다.

Degree of conversion of resin composite cured by light through a translucent fiber posts

  • Urapepon, Somchai
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권3호
    • /
    • pp.194-199
    • /
    • 2014
  • PURPOSE. This study evaluated the depth of cure of resin composite cured by light through a translucent fiber post. MATERIALS AND METHODS. The opaque plastic tubes in various lengths of 2, 4, 6, 8, 10, 12, 14 mm. were filled with resin composite in which two different translucent fiber posts were inserted into the center and photo-polymerized for 40 seconds. The degree of conversion of the cured composite at bottom surface were examined using Fourier transform infrared attenuated total reflection spectrometer (FTIR/ATR) at 0.1, 0.5 and 1.0 mm apart from the post surface. RESULTS. The degree of conversion of the 0.1 mm, 0.5 mm, 1.0 mm apart from the post surface was highest at the 2 mm level and continuously decreased when the distance from the light source was increased and drastically decreased when the depth from the top of the post was greater than 4-6 mm. For each level, the highest degree of conversion was at 0.1 mm from the post surface and decreased continuously when the distance apart from the post surface was increased. CONCLUSION. The quantity of light transmission depends on the type of post and the light transmission capability of the post, especially after 4-6 mm depth and the area further apart from the post surface, are insufficient for clinical light activation of resin composite.

Response of Growth and Development of Young Tomato Plants to End-of-day Monochromatic Light from Various LEDs

  • Khoshimkhujaev, Bekhzod;Kwon, Joon Kook;Lee, Jae Han;Choi, Hyo Gil;Park, Kyoung Sub;Kang, Nam Jun
    • 농업생명과학연구
    • /
    • 제50권5호
    • /
    • pp.1-9
    • /
    • 2016
  • Plant growth and development strongly influenced by light quantity and its spectral composition. Young tomato plants were cultivated in growth cabinets under artificial light provided by red and blue light emitting diodes(LEDs) during 12 hours, then plants were exposed to monochromatic ultraviolet, blue, green and red lights as an end-of-day(EOD) treatment during 4 hours to study their effect on plant growth parameters. EOD lighting from various LEDs increased total fresh and dry weights as well as assimilation area compared to those in control. Blue light increased stem height, internode length and stem diameter. Monochromatic UV-A light reduced stem elongation, highly increased stomatal conductance. Compactness and health index of young tomato plants were increased in UV-A and red light treatments.

메디컬 링 라이트의 개발 (Development of Ring Right for Medical Purpose)

  • 천민우;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.766-767
    • /
    • 2010
  • 최근 주목받고 있는 광원인 LED를 이용하여 국소 환부 부위의 무영 촬영을 위해 의료용 링 라이트를 개발하였다. 개발된 링 라이트는 PWM 방식을 이용하여 다양한 광량의 조절이 가능하도록 설계하였으며 각각의 LED를 독립적으로 제어함으로 색온도 및 연색성의 조절이 가능하다. 또한 환부의 연속 촬영을 위한 지속광과 순간적인 촬영을 위한 플래시 모드의 동작이 가능 하다. 본 연구에서는 환부의 순간적인 무영촬영을 위해 구성된 인터페이스 회로를 이용하여 순간적인 플래시 기능의 응답속도를 확인하였다.

  • PDF

경질유 유량표준장치의 신뢰도 검증을 위한 측정정확도 비교 (Intercomparison of Light Oil Flow Standard System for the Reliability of Measurement Accuracy)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제32권9호
    • /
    • pp.712-719
    • /
    • 2008
  • Light Oil Flow Standard System(LOFSS), as a national oil flow standard system, in Korea Research Institute of Standards and Science(KRISS) was developed for oil flowmeter calibration, and the expanded uncertainty of flow quantity determination was estimated within 0.04 %. In order to improve the reliability of the LOFSS measurement, a proficiency test was carried out in the flow range of 20 and $240\;m^3/h$ (Reynolds number $20,000{\sim}900,000$). A turbine flowmeter was used as a transfer package in round robin test. The water flow standard system of KRISS, the pipe prover of the national calibration and test organization and the master meter calibrator of the turbine flowmeter supplier, which used the different working fluid respectively, were compared with the turbine flowmeter measurement. The maximum difference of measurement was 0.15 % between the LOFSS and the pipe prover. The En numbers of the each system measurement were evaluated at the same Reynolds number. It was found that the En numbers were less than 1 in the comparison, which means the procedures of the uncertainty estimation of the each calibrators were reasonable and reliable.

Build-Up 기법을 이용한 경질유 표준장치의 측정범위 확장 (Flow Range Extension of Light Oil Flowmeter Standard System with Build-Up Technique)

  • 임기원;최종오
    • 대한기계학회논문집B
    • /
    • 제30권12호
    • /
    • pp.1139-1146
    • /
    • 2006
  • Light Oil Flow Standard System(LOFSS) in Korea Research Institute of Standards and Science(KRISS) was designed for oil flowmeter calibration. In order to extend the flow range from 120 $m^3/h$ to 200 $m^3/h$, the build-up technique was applied with two positive displacement flowmeters as master flowmeter. The master flowmeters were calibrated against with LOFSS, which has 0.04 % uncertainty of flow quantity determination, then the test flowmeter is calibrated against two master flowmeters. For uncertainty analysis, the repeatability of master flowmeters, the variation of the fluid density and the pipe volume due to temperature change were scrutinized. The contribution of each uncertainty factors to the calibrator and the correlation of each factors were discussed. For investigating the feasibility of uncertainty analysis, a turbine flowmeter as a transfer package was tested with LOFSS and two reference flowmeter. The hypothesis test for both results was coincide with a 95 % significant level. This means that the uncertainty analysis procedure of the calibrator is reasonable and the extension of flow range with master meters was carry out successfully.