• 제목/요약/키워드: Quantitative visualization

검색결과 213건 처리시간 0.023초

수평 사각밀폐공간내의 전도열전달 기구에서 열모세관효과 (The Thermocapillary Effect on Pure Conduction Mechanism in a Closed Square Cavity)

  • 유재봉;안도원;유주식;엄용균
    • 대한기계학회논문집B
    • /
    • 제29권11호
    • /
    • pp.1209-1219
    • /
    • 2005
  • In a closed square cavity filled with a liquid, a cooling horizontal upper wall and a heating lower wall, the flow isn't generated under the ground-based condition when Rayleigh number is lower than 1700. In this mechanism, Ra=1534, Temperature and velocity fields near an air-bubble in silicon-oil under a cooled upper wall were investigated. Temperature and velocity fields is visualized using the thermo-sensitive liquid-crystal and light sheet visualization technique. The quantitative analysis fer the temperature and the flow fields were carried out by applying the image processing technique to the original data. The symmetry shape of two vortexes near an air bubble was observed. As the bubble size increased, the size of vortex and the magnitude of velocity increased. In spite of elapsed time, a pair of vortexes was the unique and steady-state flow in a square cavity and wasn't induced to the other flow in the surround region.

UAV용 추력편향 노즐의 정량적 특성에 관한 실험적 연구 (Experimental Study of the Quantitative Characteristics of Fluidic Thrust Vectoring Nozzle for UAV)

  • 박상훈;이열
    • 한국항공우주학회지
    • /
    • 제42권9호
    • /
    • pp.723-730
    • /
    • 2014
  • 이차유동을 이용한 초음속 동축류 추력편향 제어기법에 대한 실험적 연구가 진행되었다. 쉴리렌 유동가시화 및 로드셀을 이용한 고정확도의 다분력 시험장치를 통하여 이차원 초음속(마하수 2.0) 유동의 추력편향 특성이 관찰되었다. 추력편향각은 부유동의 압력이 점차 커지면서 일시 감소 후 다시 증가하는 V-자형 추세를 보이고 있음이 관찰되었다. 추력편향 유동의 성능을 나타내는 성능계수들의 분석이 이루어졌으며, 보다 높은 성능지표를 나타내는 본 시스템의 운용조건이 제시되었다.

Clinical Application of MRI in an Animal Bone Graft Model

  • Liu, Xiaochen;Jia, Wenxiao;Jin, Gele;Wang, Hong;Ma, Jingxu;Wang, Yunling;Yang, Yi;Deng, Wei
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.142-149
    • /
    • 2013
  • We aim to monitor vascularization of early bone perfusion following rabbit lumbar intertransverse bone graft fusion surgery using magnetic resonance imaging assessment. Correlation with graft survival status was evaluated by histological method. Experimental animals were randomly divided into three groups and the model was established by operating bilateral lumbar intertransverse bone graft with different types of bone graft substitute material. The lumbar intertransverse area of three groups of rabbits was scanned via MRI. In addition, histological examinations were performed at the $6^{th}$ week after surgery and the quantitative analysis of the osteogenesis in different grafted area was carried out by an image analysis system. The MRI technique can be used for early postoperative evaluation of vascularized bone graft perfusion after transplantation of different bone materials, whereas histological examination allows direct visualization of the osteogenesis process.

Quantitative observation of co-current stratified two-phase flow in a horizontal rectangular channel

  • Lee, Seungtae;Euh, Dong-Jin;Kim, Seok;Song, Chul-Hwa
    • Nuclear Engineering and Technology
    • /
    • 제47권3호
    • /
    • pp.267-283
    • /
    • 2015
  • The main objective of this study is to investigate experimentally the two-phase flow characteristics in terms of the direct contact condensation of a steam-water stratified flow in a horizontal rectangular channel. Experiments were performed for both air-water and steam-water flows with a cocurrent flow configuration. This work presents the local temperature and velocity distributions in a water layer as well as the interfacial characteristics of both condensing and noncondensing fluid flows. The gas superficial velocity varied from 1.2 m/s to 2.0 m/s for air and from 1.2 m/s to 2.8 m/s for steam under a fixed inlet water superficial velocity of 0.025 m/s. Some advanced measurement methods have been applied to measure the local characteristics of the water layer thickness, temperature, and velocity fields in a horizontal stratified flow. The instantaneous velocity and temperature fields inside the water layer were measured using laser-induced fluorescence and particle image velocimetry, respectively. In addition, the water layer thickness was measured through an ultrasonic method.

2행정 디젤기관의 소기 효율 평가에 관한 연구 (A Study on the Evaluation of Scavenging Efficiency in a Two-Stroke Diesel Engine.)

  • 조규백;강건용;이진욱;정용일
    • 연구논문집
    • /
    • 통권28호
    • /
    • pp.49-58
    • /
    • 1998
  • 포핏밸브형 2행정 기관의 소기 시스템 형상 변화에 따른 소기유동 및 소기효율의 개선 효과를 해석하기 위해, 각 흡기포트 형상별 소기 유동 가시화와 소기효율 정량화 연구를 수행하고자 한다. 소기시스템의 형상은 기계연구원에서 독자 개발한 RSSV(Rotatable Shrouded Scavenging Valve)의 슈라우드 각도를 변화시켰으며, 소기 효율 정량화를 위해 정상상태하에서 등유와 착색된 물을 사용한 single-cycle method. 동적모사장치(dynamic simulatior)에서 $CO_2$$O_2$가스를 사용한 가스추출법(gas sampling method)을 적용하였으며 실제 기관에서의 소기 효율을 측정하기 위해 압력 선도를 해석하였다. 위 실험들의 결과로부터 $90^circ$슈라우드 밸브가 가장 높은 효율을 가지는 것으로 판명되었으며, 특히 이들 실험방법들은 2행정 엔진 개발에 있어 시간과 비용을 절감하는데 아주 유용한 기법임을 알 수 있었다.

  • PDF

Quantitative analysis using decreasing amounts of genomic DNA to assess the performance of the oligo CGH microarray

  • Song Sunny;Lazar Vladimir;Witte Anniek De;Ilsley Diane
    • 한국생물정보학회:학술대회논문집
    • /
    • 한국생물정보시스템생물학회 2006년도 Principles and Practice of Microarray for Biomedical Researchers
    • /
    • pp.71-76
    • /
    • 2006
  • Comparative genomic hybridization (CGH) is a technique for studying chromosomal changes in cancer. As cancerous cells multiply, they can undergo dramatic chromosomal changes, including chromosome loss, duplication, and the translocation of DNA from one chromosome to another. Chromosome aberrations have previously been detected using optical imaging of whole chromosomes, a technique with limited sensitivity, resolution, quantification, and throughput. Efforts in recent years to use microarrays to overcome these limitations have been hampered by inadequate sensitivity, specificity and flexibility of the microarray systems. The oligonucleotide CGH microarray system overcomes several scientific hurdles that have impeded comparative genomic studies of cancer. This new system can reliably detect single copy deletions in chromosomes. The system includes a whole human genome microarray, reagents for sample preparation, an optimized microarray processing protocol, and software for data analysis and visualization. In this study, we determined the sensitivity, accuracy and reproducibility of the new system. Using this assay, we find that the performance of the complete system was maintained over a range of input genomic DNA from 5 ug down to 0.15 ug.

  • PDF

실시간 근전도 패턴인식을 위한 특징투영 기법에 관한 연구 (A Study on Feature Projection Methods for a Real-Time EMG Pattern Recognition)

  • 추준욱;김신기;문무성;문인혁
    • 제어로봇시스템학회논문지
    • /
    • 제12권9호
    • /
    • pp.935-944
    • /
    • 2006
  • EMG pattern recognition is essential for the control of a multifunction myoelectric hand. The main goal of this study is to develop an efficient feature projection method for EMC pattern recognition. To this end, we propose a linear supervised feature projection that utilizes linear discriminant analysis (LDA). We first perform wavelet packet transform (WPT) to extract the feature vector from four channel EMC signals. For dimensionality reduction and clustering of the WPT features, the LDA incorporates class information into the learning procedure, and finds a linear matrix to maximize the class separability for the projected features. Finally, the multilayer perceptron classifies the LDA-reduced features into nine hand motions. To evaluate the performance of LDA for the WPT features, we compare LDA with three other feature projection methods. From a visualization and quantitative comparison, we show that LDA has better performance for the class separability, and the LDA-projected features improve the classification accuracy with a short processing time. We implemented a real-time pattern recognition system for a multifunction myoelectric hand. In experiment, we show that the proposed method achieves 97.2% recognition accuracy, and that all processes, including the generation of control commands for myoelectric hand, are completed within 97 msec. These results confirm that our method is applicable to real-time EMG pattern recognition far myoelectric hand control.

3차원 유동장 측정용 홀로그래피 간섭토모그래피 (Holographic interferometric tomography for reconstructing a three- dimensional flow field)

  • 차동진
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.749-757
    • /
    • 1999
  • Holographic interferornetric tomography can provide reconstruction of instantaneous three dimensional gross flow fields. The technique however confronts ill-posed reconstruction problems in practical applications. Experimental data are usually limited in projection and angular scanning when a field is captured instantaneously or under the obstruction of test models and test section enclosures. An algorithm, based on a series expansion method, has been developed to improve the reconstruction under the ill-posed conditions. A three-dimensional natural convection flow around two interacting isothermal cubes is experimentally investigated. The flow can provide a challenging reconstruction problem and lend itself to accurate numerical solution for comparison. The refractive index fields at two horizontal sections of the thermal plume with and without an opaque object are reconstructed at a limited view angle of 80" The experimental reconstructions are then compared with those from numerical calculation and thermocouple thermometry. It confirms that the technique is applicable to reconstruction of reasonably complex, three-dimensional flow fields.elds.

  • PDF

와동 발생기를 이용한 자외선 살균 시스템 성능 향상에 관한 연구 (A Study on Enhancement of UV Disinfection System Performance by the Vortex Generator)

  • 김봉환;안국찬;김동진
    • 한국안전학회지
    • /
    • 제22권1호
    • /
    • pp.24-29
    • /
    • 2007
  • The effectiveness of a UV(ultra violet) disinfection system depends on the characteristics of the waste water, flow conditions, the intensity of UV radiation, the amount of time the microorganisms are exposed to the radiation, and the reactor configuration. The wast water flow conditions are important factors in the design of UV disinfection system from the point of enhancement view of UV disinfection. The turbulent energy intensity in the wake by the vortex shedding are effective for UV radiation. Therewith the effectiveness of vortex generator is considered as a enhancement of UV disinfection. The experimental results presented give important evidences and explain that it is possible to predict UV disinfection performance based on flow experiments. An experimental investigation of two types of the vortex generator is presented. The qualitative and quantitative evaluations of the wake are made by flow visualization using smoke wire method and the measurement of vortex frequencies in the wind tunnel. From the experiment, following results were obtained that the delta wing type vortex generator is more effective than circular type because of the higher vortex frequencies and the smaller drag.

유정란 태아외부혈관의 단계적으로 분기되는 동맥 분지관 내부 혈액 유동특성의 in-vivo 계측 (In-vivo Measurements of Blood Flow Characteristics in the Arterial Bifurcation Cascade Networks of Chicken Embryo)

  • 이정엽;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.121-124
    • /
    • 2006
  • The arteries are very important in cardiovascular system and easily adapt to varying flow and pressure conditions by enlarging or shrinking to meet the given hemodynamic demands. The blood flow in arteries is dominated by unsteady flow phenomena due to heart beating. In certain circumstances, however, unusual hemodynamic conditions cause an abnormal biological response and often induce circulatory diseases such as atherosclerosis, thrombosis and inflammation. Therefore quantitative analysis of the unsteady pulsatile flow characteristics in the arterial blood vessels plays important roles in diagnosing these circulatory diseases. In order to verify the hemodynamic characteristics, in-vivo measurements of blood flow inside the extraembryonic arterial bifurcation cascade of chicken embryo were carried out using a micro-PIV technique. To analyze the unsteady pulsatile flow temporally, the (low images of RBCs were obtained using a high-speed CMOS camera at 250fps with a spatial resolution of $30{\mu}m\times30{\mu}m$ in the whole blood vessels. In this study, the unusual flow conditions such as flow separation or secondary flow were not observed in the arterial bifurcations. However, the vorticity has large values in the inner side of curvature of vessels. In addition, the mean velocity in the arterial blood vessel was decreased and pulsating frequency obtained by FFT analysis of velocity data extracted in front of the each bifurcation was also decreased as the bifurcation cascaded.

  • PDF