• 제목/요약/키워드: Quantitative parameters

검색결과 1,130건 처리시간 0.021초

Multi-camera System Calibration with Built-in Relative Orientation Constraints (Part 2) Automation, Implementation, and Experimental Results

  • Lari, Zahra;Habib, Ayman;Mazaheri, Mehdi;Al-Durgham, Kaleel
    • 한국측량학회지
    • /
    • 제32권3호
    • /
    • pp.205-216
    • /
    • 2014
  • Multi-camera systems have been widely used as cost-effective tools for the collection of geospatial data for various applications. In order to fully achieve the potential accuracy of these systems for object space reconstruction, careful system calibration should be carried out prior to data collection. Since the structural integrity of the involved cameras' components and system mounting parameters cannot be guaranteed over time, multi-camera system should be frequently calibrated to confirm the stability of the estimated parameters. Therefore, automated techniques are needed to facilitate and speed up the system calibration procedure. The automation of the multi-camera system calibration approach, which was proposed in the first part of this paper, is contingent on the automated detection, localization, and identification of the object space signalized targets in the images. In this paper, the automation of the proposed camera calibration procedure through automatic target extraction and labelling approaches will be presented. The introduced automated system calibration procedure is then implemented for a newly-developed multi-camera system while considering the optimum configuration for the data collection. Experimental results from the implemented system calibration procedure are finally presented to verify the feasibility the proposed automated procedure. Qualitative and quantitative evaluation of the estimated system calibration parameters from two-calibration sessions is also presented to confirm the stability of the cameras' interior orientation and system mounting parameters.

RELATIONSHIPS OF THE SOLAR WIND PARAMETERS WITH THE MAGNETIC STORM MAGNITUDE AND THEIR ASSOCIATION WITH THE INTERPLANETARY SHOCK

  • OH SU YEON;YI YU
    • 천문학회지
    • /
    • 제37권4호
    • /
    • pp.151-157
    • /
    • 2004
  • It is investigated quantitative relations between the magnetic storm magnitude and the solar wind parameters such as the Interplanetary Magnetic Field (hereinafter, IMF) magnitude (B), the southward component of IMF (Bz), and the dynamic pressure during the main phase of the magnetic storm with focus on the role of the interplanetary shock (hereinafter, IPS) in order to build the space weather fore-casting model in the future capable to predict the occurrence of the magnetic storm and its magnitude quantitatively. Total 113 moderate and intense magnetic storms and 189 forward IPSs are selected for four years from 1998 to 2001. The results agree with the general consensus that solar wind parameter, especially, Bz component in the shocked gas region plays the most important role in generating storms (Tsurutani and Gonzales, 1997). However, we found that the correlations between the solar wind parameters and the magnetic storm magnitude are higher in case the storm happens after the IPS passing than in case the storm occurs without any IPS influence. The correlation coefficients of B and $BZ_(min)$ are specially over 0.8 while the magnetic storms are driven by IPSs. Even though recently a Dst prediction model based on the real time solar wind data (Temerin and Li, 2002) is made, our correlation test results would be supplementary in estimating the prediction error of such kind of model and in improving the model by using the different fitting parameters in cases associated with IPS or not associated with IPS rather than single fitting parameter in the current model.

음성장애에 대한 음향학적 중등도 지표 (The Acoustic Severity Index in the Pathologic Voice)

  • 홍기환;김현기;양윤수
    • 음성과학
    • /
    • 제10권4호
    • /
    • pp.201-219
    • /
    • 2003
  • Background: The perceptual assessment is generally performed by the voice specialist. The objective evaluation is performed in a voice laboratory. Research in voice laboratories has generated a variety of different objective tests and parameters. The perceptual evaluation is one of the most controversial topics in voice research. Review of literature reveals a wide variety of rating scales and reliability data fluctuating from study to study. Unfortunately, there is no widely accepted valid method for classifying voice disorders and assessing outcome after voice treatment. Objectives: The goals of this research were to identify important objective acoustic parameters of vocal quality, and to establish an objective and quantitative correlate of the perceived vocal quality. Materials and Methods : We evaluated the voice analyzed data from 122 dysphonic patients and 20 normal volunteers. A computerized speech lab. 4300B(CSL) was used to carry out the analysis of each voice sample. Results: Three dysphonia severity indices(DSI) were created using discriminant analysis. DSI is based on the weighted combination of the following selected set of acoustic parameters: absolute jitter(Jita in us), smoothed pitch period perturbation (sPPQ in %), amplitude perturbation quotient(APQ in %), soft phonation index(SPI), average fundamental frequency(Fo in Hz), lowest fundamental frequency(Flo in Hz), and smoothed amplitude perturbation quotient(sAPQ in %). The DSI, being the discriminating rule calculated by the logistic regression, consists of three equation based on statistically significant acoustic parameters. Three DSI were created to reflects best the degree of hoarseness as expressed by G from the GRBAS scale. The more positive this DSI is for a patient, the worse the vocal quality. The more it is negative, the better it is. The effect of sex is included implicitly in the DSI-1 and DSI-2, so that a separate DSI-1 and DSI-2 for males and females need not be used. The DSI is objective because no perceptual input is required for its calculation. Conculsion : This research demonstrates that the voice function values calculated from three different multivariate objective dysphonia severity indices are significantly associated with subjective voice assessments. These multivariate objective dysphonia severity indices may be appropriate for use in clinical trials and outcomes research on treatment effectiveness for voice disorders.

  • PDF

Visual Explanation of a Deep Learning Solar Flare Forecast Model and Its Relationship to Physical Parameters

  • Yi, Kangwoo;Moon, Yong-Jae;Lim, Daye;Park, Eunsu;Lee, Harim
    • 천문학회보
    • /
    • 제46권1호
    • /
    • pp.42.1-42.1
    • /
    • 2021
  • In this study, we present a visual explanation of a deep learning solar flare forecast model and its relationship to physical parameters of solar active regions (ARs). For this, we use full-disk magnetograms at 00:00 UT from the Solar and Heliospheric Observatory/Michelson Doppler Imager and the Solar Dynamics Observatory/Helioseismic and Magnetic Imager, physical parameters from the Space-weather HMI Active Region Patch (SHARP), and Geostationary Operational Environmental Satellite X-ray flare data. Our deep learning flare forecast model based on the Convolutional Neural Network (CNN) predicts "Yes" or "No" for the daily occurrence of C-, M-, and X-class flares. We interpret the model using two CNN attribution methods (guided backpropagation and Gradient-weighted Class Activation Mapping [Grad-CAM]) that provide quantitative information on explaining the model. We find that our deep learning flare forecasting model is intimately related to AR physical properties that have also been distinguished in previous studies as holding significant predictive ability. Major results of this study are as follows. First, we successfully apply our deep learning models to the forecast of daily solar flare occurrence with TSS = 0.65, without any preprocessing to extract features from data. Second, using the attribution methods, we find that the polarity inversion line is an important feature for the deep learning flare forecasting model. Third, the ARs with high Grad-CAM values produce more flares than those with low Grad-CAM values. Fourth, nine SHARP parameters such as total unsigned vertical current, total unsigned current helicity, total unsigned flux, and total photospheric magnetic free energy density are well correlated with Grad-CAM values.

  • PDF

Assessment of Diffusion Tensor Imaging Parameters of Hepatic Parenchyma for Differentiation of Biliary Atresia from Alagille Syndrome

  • Ahmed Abdel Khalek Abdel Razek;Ahmed Abdalla;Reda Elfar;Germeen Albair Ashmalla;Khadiga Ali;Tarik Barakat
    • Korean Journal of Radiology
    • /
    • 제21권12호
    • /
    • pp.1367-1373
    • /
    • 2020
  • Objective: To assess diffusion tensor imaging (DTI) parameters of the hepatic parenchyma for the differentiation of biliary atresia (BA) from Alagille syndrome (ALGS). Materials and Methods: This study included 32 infants with BA and 12 infants with ALGS groups who had undergone DTI. Fractional anisotropy (FA) and mean diffusivity (MD) of the liver were calculated twice by two separate readers and hepatic tissue was biopsied. Statistical analyses were performed to determine the mean values of the two groups. The optimum cut-off values for DTI differentiation of BA and ALGS were calculated by receiver operating characteristic (ROC) analysis. Results: The mean hepatic MD of BA (1.56 ± 0.20 and 1.63 ± 0.2 × 10-3 mm2/s) was significantly lower than that of ALGS (1.84 ± 0.04 and 1.79 ± 0.03 × 10-3 mm2/s) for both readers (r = 0.8, p = 0.001). Hepatic MD values of 1.77 and 1.79 × 10-3 mm2/s as a threshold for differentiating BA from ALGS showed accuracies of 82 and 79% and area under the curves (AUCs) of 0.90 and 0.91 for both readers, respectively. The mean hepatic FA of BA (0.34 ± 0.04 and 0.36 ± 0.04) was significantly higher (p = 0.01, 0.02) than that of ALGS (0.30 ± 0.06 and 0.31 ± 0.05) for both readers (r = 0.80, p = 0.001). FA values of 0.30 and 0.28 as a threshold for differentiating BA from ALGS showed accuracies of 75% and 82% and AUCs of 0.69 and 0.68 for both readers, respectively. Conclusion: Hepatic DTI parameters are promising quantitative imaging parameters for the detection of hepatic parenchymal changes in BA and ALGS and may be an additional noninvasive imaging tool for the differentiation of BA from ALGS.

신경질환의 진단을 위한 탈신경 전위와 종판 전위의 구별에 관한 연구 (A Study for the Distinction between Denervation Potentials and Endplate Spikes for the Diagnosis of Neuropathy)

  • 임재중;김남균;황윤성;박인선
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권4호
    • /
    • pp.451-459
    • /
    • 1999
  • 신경질환의 진단에 있어서 근육군에서의 세동전위나 양성예각파와 같은 탈신경전위를 관찰함으로써 신경의 이상유무와 손상부위를 예측할수 있는데 이는 임상의의 주관적인 경험에만 의존하여 구별되고 있으며 검사과정 중 정상인에게서도 나타날 수 있는 종판전위가 탈신경전위로 오인되어 진단에 혼선을초래할 수 있다. 따라서 본 연구는 탈신경전위와 종판전위를 정량적으로 구별할 수 있는 알고리듬을 수립하는데 필요한 매개변수들을 추출함으로써 신경손상의 진단과 병변의 국소화에 정확성을 향상시키고자 하였다. 본 연구에서는 여러 종류의 신경손상을 보이는 10명의 환자들에 대한 근전도 검사를 실시하여 탈신경전위인 양성예각파나 세동전위, 그리고 종판전위를 검출하였다. 이들 신호로부터 지속시간, 면적, 기울기, 첨두시간 진폭, 양첨두지 진폭, 음첨두치 진폭 및 첨두치 비율 그리고 상(phase)의 여덟가지 매개변수를 구하고 각 파형에서의 값들을 비교하였다. 그 결과, 두 종류의 탈신경전위와 종판전위의 구분에 공통적으로 좋은 결과를 제공하는 매개변수는 기울기, 첨두치간 진폭, 양첨두치 진폭 그리고 첨두치간의 비율로 나타났다. 본 연구를 통해 구해진 매개변수들의 특성은 근전도 분석의 자동화를 위한 알고리듬의 수립에 응용되어질 수 있을 것이며 보다 정량화된 근전도 분석을 통해 진단의 정확성을 향상시켜 줄 것이다.

  • PDF

자기공명영상장치의 뇌 T2 강조 영상에서 여기횟수 변화에 따른 영상 특성의 경향성 평가: MRiLab Simulation 연구 (Evaluation of Tendency for Characteristics of MRI Brain T2 Weighted Images according to Changing NEX: MRiLab Simulation Study)

  • 김남영;김주희;임준;강성현;이영진
    • 한국방사선학회논문지
    • /
    • 제15권1호
    • /
    • pp.9-14
    • /
    • 2021
  • 방사선에 의한 피폭 없이 대조도가 우수한 영상의 획득이 가능한 자기공명영상은 진단에 필수적이지만 영상에서의 노이즈 발생은 불가피한 요소이기 때문에 이를 보완하기 위해 자기공명영상장치의 변수들을 조절하여 우수한 특성을 가진 영상을 획득할 수 있다. 이 중, 여기횟수 (NEX; number of excitation)는 추가적인 영상 특성의 저하 없이 우수한 특성의 영상을 획득할 수 있지만 scan time이 증가하여 motion artifact를 발생시킬 수 있고, scan time의 증가에 비례하여 영상의 특성이 향상되지 않기 때문에 적절한 NEX의 설정이 필요하다. 따라서, 본 연구에서는 MRiLab simulation program을 통해 자기공명영상의 모든 변수들을 고정시킨 후, NEX만을 조절하여 획득한 뇌 T2 강조 영상의 정량적 평가를 통해 NEX 변화에 따른 영상 특성의 경향성을 평가하고자 하였다. 획득한 영상의 노이즈 레벨 및 유사도 평가를 하기 위해 신호 대 잡음비 (SNR; signal to noise ratio), 대조도 대 잡음비 (CNR; contrast to noise ratio), 평균 제곱근 오차 (RMSE; root mean square error) 그리고 최대 신호 대 잡음비 (PSNR; peak signal to noise ratio)를 계산하였다. 결과적으로, 노이즈 레벨 및 유사도 평가 인자 모두 NEX가 증가함에 따라 개선된 값을 보였으나, 점차 증가폭이 감소함을 보였다. 따라서, 과도하게 큰 NEX는 장시간의 scan에 따른 motion artifact를 발생시켜 영상 특성을 저하시킬 수 있으므로, 적절한 NEX의 설정이 중요함을 확인하였다.

Usefulness of Bone SPECT/CT for Predicting Avascular Necrosis of the Femoral Head in Children with Slipped Capital Femoral Epiphysis or Femoral Neck Fracture

  • Yoo Sung Song;Won Woo Lee;Moon Seok Park;Nak Tscheol Kim;Ki Hyuk Sung
    • Korean Journal of Radiology
    • /
    • 제23권2호
    • /
    • pp.264-270
    • /
    • 2022
  • Objective: This study aimed to investigate the usefulness of bone single-positron emission tomography/computed tomography (SPECT/CT) of the hip in predicting the later occurrence of avascular necrosis (AVN) after slipped capital femoral epiphysis (SCFE) or femoral neck fracture in pediatric patients. The quantitative parameters of SPECT/CT useful in predicting AVN were identified. Materials and Methods: Twenty-one (male:female, 10:11) consecutive patients aged < 18 years (mean age ± standard deviation [SD], 11.0 ± 2.7 years) who underwent surgery for SCFE or femoral neck fracture and postoperative bone SPECT/CT were included. The maximum standardized uptake value (SUV), mean SUV, and minimum SUV of the femoral head were measured. The ratios of the maximum SUV, mean SUV, and minimum SUV of the affected femoral head to the contralateral side were determined. Patients were followed up for > 1 year after the surgery. The SPECT/CT parameters were compared between patients who developed AVN and those who did not. The accuracy of SPECT/CT parameters for predicting AVN was assessed. Results: Six patients developed AVN. There was a significant difference in the ratio of the mean SUV among patients who developed AVN (mean ± SD, 0.8 ± 0.3) and those who did not (1.1 ± 0.2, p = 0.018). However, there were no significant differences in the ratios of the maximum and minimum SUV between the groups (all p = 0.205). For the maximum, mean, and minimum SUVs, no significant differences were observed between the groups (p = 0.519, 0.733, and 0.470, respectively). The cutoff mean SUV ratio of 0.87 yielded a 66.7% sensitivity and 93.2% specificity for predicting AVN. Conclusion: Quantitative bone SPECT/CT is useful for evaluating femoral head viability in pediatric patients with SCFE or femoral neck fractures. Clinicians should consider the high possibility of later AVN development in patients with a decreased mean SUV ratio.

Chemotherapy-Related Cardiac Dysfunction: Quantitative Cardiac Magnetic Resonance Image Parameters and Their Prognostic Implications

  • Jinhee Kim;Yoo Jin Hong;Kyunghwa Han;Jin Young Kim;Hye-Jeong Lee;Jin Hur;Young Jin Kim;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • 제24권9호
    • /
    • pp.838-848
    • /
    • 2023
  • Objective: To quantitatively analyze the cardiac magnetic resonance imaging (CMR) characteristics of chemotherapy-related cardiac dysfunction (CTRCD) and explore their prognostic value for major adverse cardiovascular events (MACE). Materials and Methods: A total of 145 patients (male:female = 76:69, mean age = 63.0 years) with cancer and heart failure who underwent CMR between January 2015 and January 2021 were included. CMR was performed using a 3T scanner (Siemens). Biventricular functions, native T1 T2, extracellular volume fraction (ECV) values, and late gadolinium enhancement (LGE) of the left ventricle (LV) were compared between those with and without CTRCD. These were compared between patients with mild-to-moderate CTRCD and those with severe CTRCD. Cox proportional hazard regression analysis was used to evaluate the association between the CMR parameters and MACE occurrence during follow-up in the CTRCD patients. Results: Among 145 patients, 61 had CTRCD and 84 did not have CTRCD. Native T1, ECV, and T2 were significantly higher in the CTRCD group (1336.9 ms, 32.5%, and 44.7 ms, respectively) than those in the non-CTRCD group (1303.4 ms, 30.5%, and 42.0 ms, respectively; P = 0.013, 0.010, and < 0.001, respectively). They were not significantly different between patients with mild-to-moderate and severe CTRCD. Indexed LV mass was significantly smaller in the CTRCD group (65.0 g/m2 vs. 78.9 g/mm2; P < 0.001). According to the multivariable Cox regression analysis, T2 (hazard ratio [HR]: 1.14, 95% confidence interval [CI]: 1.01-1.27; P = 0.028) and quantified LGE (HR: 1.07, 95% CI: 1.01-1.13; P = 0.021) were independently associated with MACE in the CTRCD patients. Conclusion: Quantitative parameters from CMR have the potential to evaluate myocardial changes in CTRCD. Increased T2 with reduced LV mass was demonstrated in CTRCD patients even before the development of severe cardiac dysfunction. T2 and quantified LGE may be independent prognostic factors for MACE in patients with CTRCD.

Sensitivity of Input Parameters in the Spectral Wave Model

  • 박효봉
    • 한국해양공학회지
    • /
    • 제23권2호
    • /
    • pp.28-36
    • /
    • 2009
  • Many researches have been done to define the physical parameters for the wave generation and transformation over a coastal region. However, most of these have been limited to the application of particular conditions, as they are generally too empirical. To yield more reasonable wave estimation using a spectral wave model, it is important to understand how they work for the wave estimation. This study involved a comprehensive sensitivity test against the spectral resolution and the physical source/sink terms of the spectral wave model using SWAN and TOMAWAC, which have the same physical background with several different empirical/theoretical formulations. The tests were conducted for the East Anglian coast, UK, which is characterized by a complex bathymetry due to several shoals and offshore sandbanks. For the quantitative and qualitative evaluation of the models' performance with different input conditions, the wave elements and spectrums predicted at representative sites the East Anglia coast were compared/analyzed. The spectral resolution had no significant effect on the model results, but the lowest resolution on the frequency and direction induced underestimations of the wave height and period. The bottom friction and depth-induced breaking terms produced relatively high variations in the wave prediction, depending on which formulation was applied. The terms for the quadruplet and whitecapping had little effect on the wave estimation, whereas the triads tended to predict shorter and higher waves by energy transferring to higher frequencies.