• Title/Summary/Keyword: Quantification Analysis

Search Result 1,437, Processing Time 0.031 seconds

Enhancing the radar-based mean areal precipitation forecasts to improve urban flood predictions and uncertainty quantification

  • Nguyen, Duc Hai;Kwon, Hyun-Han;Yoon, Seong-Sim;Bae, Deg-Hyo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.123-123
    • /
    • 2020
  • The present study is aimed to correcting radar-based mean areal precipitation forecasts to improve urban flood predictions and uncertainty analysis of water levels contributed at each stage in the process. For this reason, a long short-term memory (LSTM) network is used to reproduce three-hour mean areal precipitation (MAP) forecasts from the quantitative precipitation forecasts (QPFs) of the McGill Algorithm for Precipitation nowcasting by Lagrangian Extrapolation (MAPLE). The Gangnam urban catchment located in Seoul, South Korea, was selected as a case study for the purpose. A database was established based on 24 heavy rainfall events, 22 grid points from the MAPLE system and the observed MAP values estimated from five ground rain gauges of KMA Automatic Weather System. The corrected MAP forecasts were input into the developed coupled 1D/2D model to predict water levels and relevant inundation areas. The results indicate the viability of the proposed framework for generating three-hour MAP forecasts and urban flooding predictions. For the analysis uncertainty contributions of the source related to the process, the Bayesian Markov Chain Monte Carlo (MCMC) using delayed rejection and adaptive metropolis algorithm is applied. For this purpose, the uncertainty contributions of the stages such as QPE input, QPF MAP source LSTM-corrected source, and MAP input and the coupled model is discussed.

  • PDF

In-Vitro Model Design of Mitral Valve Regurgitation and Comparative Study of Quantification between PISA and 4D flow MRI (승모판 역류 In-Vitro 모델을 활용한 초음파 및 4D flow MRI 기반 혈류 정량화 비교연구)

  • Juyeon Lee;Minseong Kwon;Hyungkyu Huh
    • Journal of the Korean Society of Visualization
    • /
    • v.22 no.1
    • /
    • pp.40-48
    • /
    • 2024
  • This study presents an in-vitro model designed to simulate mitral valve regurgitation, aiming to compare the quantification results between Proximal Isovelocity Surface Area(PISA) and 4D Flow MRI on both fixed and valve annulus tracking(VAT) views. The in-vitro model replicates the dynamic conditions of the mitral valve in a pulsatile environment, utilizing a piston pump set at 60 bpm. Through systematic experiments and analysis, the study evaluates the accuracy and effectiveness of PISA and 4D Flow MRI in assessing regurgitation severity, considering both fixed and valve annulus tracking. The displacement length measured in echo closely resembled that of optical measurements, making it advantageous for structural analysis. VAT-4D flow MRI exhibited the smallest deviation from actual flow rate values, establishing it as most accurate method for quantitative regurgitation assessment.

3D Measurement Method Based on Point Cloud and Solid Model for Urban SingleTrees (Point cloud와 solid model을 기반으로 한 단일수목 입체적 정량화기법 연구)

  • Park, Haekyung
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.6_2
    • /
    • pp.1139-1149
    • /
    • 2017
  • Measuring tree's volume is very important input data of various environmental analysis modeling However, It's difficult to use economical and equipment to measure a fragmented small green space in the city. In addition, Trees are sensitive to seasons, so we need new and easier equipment and quantification methods for measuring trees than lidar for high frequency monitoring. In particular, the tree's size in a city affect management costs, ecosystem services, safety, and so need to be managed and informed on the individual tree-based. In this study, we aim to acquire image data with UAV(Unmanned Aerial Vehicle), which can be operated at low cost and frequently, and quickly and easily quantify a single tree using SfM-MVS(Structure from Motion-Multi View Stereo), and we evaluate the impact of reducing number of images on the point density of point clouds generated from SfM-MVS and the quantification of single trees. Also, We used the Watertight model to estimate the volume of a single tree and to shape it into a 3D structure and compare it with the quantification results of 3 different type of 3D models. The results of the analysis show that UAV, SfM-MVS and solid model can quantify and shape a single tree with low cost and high time resolution easily. This study is only for a single tree, Therefore, in order to apply it to a larger scale, it is necessary to follow up research to develop it, such as convergence with various spatial information data, improvement of quantification technique and flight plan for enlarging green space.

Towards high-accuracy data modelling, uncertainty quantification and correlation analysis for SHM measurements during typhoon events using an improved most likely heteroscedastic Gaussian process

  • Qi-Ang Wang;Hao-Bo Wang;Zhan-Guo Ma;Yi-Qing Ni;Zhi-Jun Liu;Jian Jiang;Rui Sun;Hao-Wei Zhu
    • Smart Structures and Systems
    • /
    • v.32 no.4
    • /
    • pp.267-279
    • /
    • 2023
  • Data modelling and interpretation for structural health monitoring (SHM) field data are critical for evaluating structural performance and quantifying the vulnerability of infrastructure systems. In order to improve the data modelling accuracy, and extend the application range from data regression analysis to out-of-sample forecasting analysis, an improved most likely heteroscedastic Gaussian process (iMLHGP) methodology is proposed in this study by the incorporation of the outof-sample forecasting algorithm. The proposed iMLHGP method overcomes this limitation of constant variance of Gaussian process (GP), and can be used for estimating non-stationary typhoon-induced response statistics with high volatility. The first attempt at performing data regression and forecasting analysis on structural responses using the proposed iMLHGP method has been presented by applying it to real-world filed SHM data from an instrumented cable-stay bridge during typhoon events. Uncertainty quantification and correlation analysis were also carried out to investigate the influence of typhoons on bridge strain data. Results show that the iMLHGP method has high accuracy in both regression and out-of-sample forecasting. The iMLHGP framework takes both data heteroscedasticity and accurate analytical processing of noise variance (replace with a point estimation on the most likely value) into account to avoid the intensive computational effort. According to uncertainty quantification and correlation analysis results, the uncertainties of strain measurements are affected by both traffic and wind speed. The overall change of bridge strain is affected by temperature, and the local fluctuation is greatly affected by wind speed in typhoon conditions.

A Large Dry PWR Containment Response Analysis for Postulated Severe Accidents (가상적 중대사고에 대한 대형건식 가압경수로 격납용기의 반응해석)

  • Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.19 no.4
    • /
    • pp.292-309
    • /
    • 1987
  • A large dry PWR containment response analysis for postulated severe accidents was performed as part of the Zion Risk Rebaselining study for input to the U.S. NRC's "Reactor Risk Reference Document," NUREG-1150. The Methodologies used in the present work were developed as part of the Severe Accident Risk Reduction Program (SARRP) at Sandia National Laboratory specifically for the Surry Plant, but they were extrapolated to Zion. Major steps of the quantification of risk from a nuclear power plant are first outlined. Then, the methodologies of containment response analysis for severe accidents used for Zion are described in detail: major features of the containment event tree (CET) analysis codes and CET quantification procedures are summarized. In addition, plant specific features important to containment response analysis are presented along with the containment loading and performance issues included in the present uncertainty analysis. Finally, a brief summary of the results of deterministic and statistical containment event tree analysis is presented to provide a perspective on the large dry PWR containment response for postulated severe accidents.accidents.

  • PDF

Development of Alternative Testing Methods without Hazardous Reagents used in Korean Pharmaceutical Codex (고시의약품 시험에 사용되는 유해시약 대체 시험법 개발)

  • Kim, Hee-Yun;Kang, Hyun-Kyung;Choi, Seon-Hee;Bang, Su-Jin;Han, Kyung-Jin;Choi, Sung-Hee;Kim, Jin-Hee;Lee, Hwa-Jung;Kang, Chan-Soon
    • YAKHAK HOEJI
    • /
    • v.54 no.2
    • /
    • pp.142-149
    • /
    • 2010
  • Development of alternative testing methods for the replacement of hazardous reagents with less hazardous ones is strongly enforced because exposure of human and environment to hazardous reagents are restricted and hazardous reagents are gradually prohibited from using in various testing methods. Thus, in this study, we developed 8 monographs from the Korean Pharmaceutical Codex by substituting the use of the hazardous reagents including ICH class 1 such as benzene, chloroform and dioxane to the use of less toxic ones like ICH class 2 or 3 reagents. We also improved their qualification and quantification performance. Among 8 monographs, the 6 newly developed TLC methods for the identification of nifedipine, oxolamine citrate, ketoprofen lysinate, chlorquinaldol, retinol acetate, and riboflavin showed a clear spot of corresponding material without any interference in spite of the replacement with ICH class 2 or 3 reagents. For the quantification of domperidone and trimebutine, HPLC methods were developed for the substitution of UV/VIS spectrometry and titrimetry, respectively. These HPLC methods were validated for the linearity, recovery, reproducibility, and inter-laboratory variations. In conclusion, the newly developed methods could be expected to become valuable tools for revising the Korean Pharmaceutical Codex.

A Study of Practical and Optimized Mineral Quantification (실용적이고 최적화된 광물정량분석법 연구)

  • Son, Byeong-Kook;An, Gi-O
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.4
    • /
    • pp.227-239
    • /
    • 2021
  • A practical and effective method of X-ray powder diffraction analysis was investigated for quantitative analysis of the mineral content of natural samples. Sample mounting experiments were conducted to select the best randomly oriented powder sample mount. A comparative experiment was also made between a reference intensity ratio (RIR) method, which compares a single peak intensity with standard material, and the Rietveld method, which calculates a full X-ray diffraction pattern, to search for the effective method of mineral quantification. In addition, samples containing amorphous minerals were quantitatively analyzed by the Rietveld method and the efficiency was reviewed. As a result of the study, the optimal random orientation could be reached by the side mounting method. The Rietveld method using the full pattern of X-ray diffraction was more suitable for mineral quantitative analysis, rather than the RIR method using a specific peak. However, either method could depend on the analyst's experience in addition to analytical technique. Moreover, amorphous minerals can be quantitatively analyzed by the Rietveld method, and the analysis results make the geological analysis possible.

A study on Broad Quantification Calibration to various isotopes for Quantitative Analysis and its SUVs assessment in SPECT/CT (SPECT/CT 장비에서 정량분석을 위한 핵종 별 Broad Quantification Calibration 시행 및 SUV 평가를 위한 팬텀 실험에 관한 연구)

  • Hyun Soo, Ko;Jae Min, Choi;Soon Ki, Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.20-31
    • /
    • 2022
  • Purpose Broad Quantification Calibration(B.Q.C) is the procedure for Quantitative Analysis to measure Standard Uptake Value(SUV) in SPECT/CT scanner. B.Q.C was performed with Tc-99m, I-123, I-131, Lu-177 respectively and then we acquired the phantom images whether the SUVs were measured accurately. Because there is no standard for SUV test in SPECT, we used ACR Esser PET phantom alternatively. The purpose of this study was to lay the groundwork for Quantitative Analysis with various isotopes in SPECT/CT scanner. Materials and Methods Siemens SPECT/CT Symbia Intevo 16 and Intevo Bold were used for this study. The procedure of B.Q.C has two steps; first is point source Sensitivity Cal. and second is Volume Sensitivity Cal. to calculate Volume Sensitivity Factor(VSF) using cylinder phantom. To verify SUV, we acquired the images with ACR Esser PET phantom and then we measured SUVmean on background and SUVmax on hot vials(25, 16, 12, 8 mm). SPSS was used to analyze the difference in the SUV between Intevo 16 and Intevo Bold by Mann-Whitney test. Results The results of Sensitivity(CPS/MBq) and VSF were in Detector 1, 2 of four isotopes (Intevo 16 D1 sensitivity/D2 sensitivity/VSF and Intevo Bold) 87.7/88.6/1.08, 91.9/91.2/1.07 on Tc-99m, 79.9/81.9/0.98, 89.4/89.4/0.98 on I-123, 124.8/128.9/0.69, 130.9, 126.8/0.71, on I-131, 8.7/8.9/1.02, 9.1/8.9/1.00 on Lu-177 respectively. The results of SUV test with ACR Esser PET phantom were (Intevo 16 BKG SUVmean/25mm SUVmax/16mm/12mm/8mm and Intevo Bold) 1.03/2.95/2.41/1.96/1.84, 1.03/2.91/2.38/1.87/1.82 on Tc-99m, 0.97/2.91/2.33/1.68/1.45, 1.00/2.80/2.23/1.57/1.32 on I-123, 0.96/1.61/1.13/1.02/0.69, 0.94/1.54/1.08/0.98/ 0.66 on I-131, 1.00/6.34/4.67/2.96/2.28, 1.01/6.21/4.49/2.86/2.21 on Lu-177. And there was no statistically significant difference of SUV between Intevo 16 and Intevo Bold(p>0.05). Conclusion Only Qualitative Analysis was possible with gamma camera in the past. On the other hand, it's possible to acquire not only anatomic localization, 3D tomography but also Quantitative Analysis with SUV measurements in SPECT/CT scanner. We could lay the groundwork for Quantitative Analysis with various isotopes; Tc-99m, I-123, I-131, Lu-177 by carrying out B.Q.C and could verify the SUV measurement with ACR phantom. It needs periodic calibration to maintain for precision of Quantitative evaluation. As a result, we can provide Quantitative Analysis on follow up scan with the SPECT/CT exams and evaluate the therapeutic response in theranosis.

Study on scheme for screening, quantification and interpretation of trace amounts of hazardous inorganic substances influencing hazard classification of a substance in REACH registration (REACH 물질 등록 시 분류에 영향을 주는 미량 유해 무기물질의 스크리닝·정량·해석을 위한 체계도 연구)

  • Kwon, Hyun-ah;Park, Kwang Seo;Son, Seung Hwan;Choe, Eun Kyung;Kim, Sanghun
    • Analytical Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.233-242
    • /
    • 2019
  • Substance identification is the first step of the REACH registration. It is essential in terms of Classification, Labelling and Packaging (CLP) regulation and because even trace amounts of impurities or additives can affect the classification. In this study, a scheme for the screening, quantification, and interpretation of trace amounts of hazardous inorganic substances is proposed to detect the presence of more than 0.1% hazardous inorganic substances that have been affecting the hazard classification. An exemplary list of hazardous inorganic substances was created from the substances of very high concern (SVHCs) in REACH. Among 201 SVHCs, there were 67 inorganic SVHCs containing at least one or ~2-3 heavy metals, such as As, Cd, Co, Cr, Pb, Sb, and Sn, in their molecular formula. The inorganic SVHCs are listed in excel format with a search function for these heavy metals so that the hazardous inorganic substances, including each heavy metal and the calculated ratio of its atomic weight to molecular weight of the hazardous inorganic substance containing it, can be searched. The case study was conducted to confirm the validity of the established scheme with zinc oxide (ZnO). In a substance that is made of ZnO, Pb was screened by XRF analysis and measured to be 0.04% (w/w) by ICP-OES analysis. After referring to the list, the presence of Pb was interpreted just as an impurity, but not as an impurity relevant for the classification. Future studies are needed to expand on this exemplary list of hazardous inorganic substances using proper regulatory data sources.

Development of Quantification Method and Stability of ${\Delta}^9$-Tetrahydrocannabinol and 11-Nor-9-carboxy-${\Delta}^9$-Tetrahydrocannabinol in Oral Fluid (타액 중 ${\Delta}^9$-Tetrahydrocannabinol 및 11-Nor-9-carboxy-${\Delta}^9$-Tetrahydrocannabinol의 분석법 확립 및 안정성 검토)

  • Choi, Hye-Young;Baeck, Seung-Kyung;Jang, Moon-Hee;Choi, Hwa-Kyung;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.54 no.4
    • /
    • pp.226-231
    • /
    • 2010
  • Oral fluid has become increasingly popular as an alternative specimen in the field of driving under the influence of drugs (DUID) and work place drug testing. In this study, an analytical method for the detection and quantification of ${\Delta}^9$-tetrahydrocannabinol (THC) and its metabolite, 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THC-COOH) in oral fluid by SPE and GC-MS was established and fully validated. The stability of THC and THC-COOH in oral fluid during storage was also determined by examining the THC and THC-COOH concentration changes depending on time and container materials. Oral fluid samples were kept over 21 days at room temperature, $-4^{\circ}C$ and $-20^{\circ}C$ in two different specimen collection tubes; glass and polypropylene tubes. Three replicates for each condition with different temperature and types of a container were analyzed at five different time points over 21 days. When oral fluid samples were stored in glass tubes, the loss of both THC and THC-COOH was less than 10% at all room temperature, $-4^{\circ}C$ and $-20^{\circ}C$. However, in polypropylene tubes, the loss of both THC and THC-COOH increased significantly over the study period. In particular, the concentration of THC decreased more rapidly than that of THC-COOH at room temperature and the maximal percentage of THC lost was 90.3% after 21 days. The result indicates that it would be necessary to collect oral fluid samples in glass containers and cool the samples until analysis in order to prevent the degradation of analytes.