• Title/Summary/Keyword: Quality of chest compression

Search Result 54, Processing Time 0.023 seconds

A Comparison of the Efficiency of Chest Compression Methods during Cardiopulmonary Resuscitation (소아 심폐소생술 중 가슴압박 방법의 효율성 비교)

  • Yun, Seong-Woo;Lee, Hyo-Ju
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.388-390
    • /
    • 2022
  • Cardiac arrest is a series of conditions that occur when the heart is stopped, regardless of the cause. Cardiac arrest due to heart disease is included in the cause of death in korea every year and is unpredictable. One of the only ways to save a patient's life when a cardiac arrest is cardiopulmonary resuscitation is to maintain circulation through this procedure. Therefore compared the quality of chest compressions with visual information using mirrors. There was a significant difference in the mean depth of chest compressions(48.93±6.76, 53.86±4.56, <0.001), and there was also a difference in compression to relaxation ratio(0.87±0.13, 0.96±0.10, <0.002). There was also a significant difference in attitude awareness(4.93±0.85, 8.14±1.38, <0.001).

  • PDF

Estimation of Chest Compression Depth during Cardiopulmonary Resuscitation by using Single Frequency Analysis (단일주파수분석을 이용한 심폐소생술 흉부압박깊이 추정)

  • U, One Sang;Kang, Seong Min;Choi, Seong Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.211-217
    • /
    • 2017
  • During the emergency situation such as cardiac arrest, cardiopulmonary resuscitation(CPR) is the most important treatment to maintain patient's blood circulation. Since the quality of CPR can not be easily measured or evaluated by the eye, an assistive device with an accelerometer can help to assess the pressure depth of CPR. In this study, we propose a single frequency analysis method to reduce the error of the accelerometer by extracting only one frequency component from the Fourier transform process. To verify the effectiveness of the single frequency analysis, acceleration data at CPR conditions were measured at a sampling rate of 50 / sec using a wristband equipped with an acceleration sensor. Then, We compared the existing distance estimation method and the single frequency analysis method using the measured data. The amplitude value proportional to the compression depth was obtained by applying the single frequency analysis method.

A Study on Quality Improvement of Cardiopulmonary Resuscitation Using Pad Attachment Glove (패드부착장갑을 이용한 심폐소생술 질 향상 연구)

  • Kim, Ye-Rim
    • Journal of Digital Convergence
    • /
    • v.17 no.11
    • /
    • pp.289-295
    • /
    • 2019
  • This study was conducted to present effective CPR by identifying the usefulness of Pad Attachment Glove. The study subjects and data collection were conducted from 1 April 2019 to 30 April on Paramedic students of G university located in G-wide city and analyzed using the SPSS/Win 23.0. The study found that the chest compressions after wearing pad attachment gloves were higher in the areas of Chest Compressions total score, Number of chest compressions, chest recoil rate, hand position accuracy, CPR velocity than before wearing them. It was understood that pad attachment gloves improved the quality of chest compressions more than Hands-Only CPR. This will be used as a basic material for cardiopulmonary resuscitation education in the future, and is believed to contribute to devising a practical program.

Chest Compression Energy(kg) Measurement of 4 Types of Rescue Device on the Floor (4종류의 구급장비 및 마루(Floor) 위에서 시행한 가슴압박 에너지(kg)측정 실험에 관한 연구)

  • Shin, Dong-Min;Han, Yong-Taek;Kim, Seung-Yong;Park, Si-Eun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.125-131
    • /
    • 2014
  • The purpose of this study is to investigate the effect of high quality CPR using the 4 types of rescue device equipment and chest compressions energy measurement in pre-hospital settings. So, we used the mode to insert load cell in ALS Skill master Manikin to develop CFMM(Compression Force Measurement Manikin) on main stretcher, CPR board, long spine board, scoop stretcher and floor. And, our research team could know that the main stretcher needed average force of 32.55 (${\pm}1.01$) kg, CPR board of 27.23 (${\pm}1.08$) kg, long spine board of 27.13 (${\pm}1.18$) kg, Scoop Stretcher of 27.38 (${\pm}1.05$) kg and Floor of 27.24 (${\pm}0.93$) kg. CPR board must be necessary in the case of CPR on main stretcher in a moving ambulance. But if the condition of patient's back surface is the removable stretcher and the long spine plate, the patient doesn't have to be spent time to use a CPR board. Furthermore, this research suggests to consider that how to take advantage of the education to students for the equipment to check in real time the energy(kg) requirement of chest compressions.

A Study on the Cardiopulmonary Resuscitation Methods in Ambulance (구급차 내에서의 심폐소생술 방법에 관한 연구)

  • Shin, So-Yeon;Kim, Jee-Hee;Kim, Gyoung-Yong;Kang, Shin-Woo;Bang, Sung-Hwan;Yun, Jong-Geun;Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.104-111
    • /
    • 2014
  • The purpose of this study is to investigate the CPR within ambulance. The Subjects were 890 emergency medical technicians in fire department in Gyeonggido. After continuing education program, the emergency medical technicians completed the questionnaires from January to February, 2012. Questionnaire consisted of demographic characteristics, method of chest compression (one handed or two handed), chest compression - ventilation ratio, and hands only CPR. Data were analyzed by frequency analysis and Chi-square test, t-test. One-way analysis of variance (ANOVA) was followed by Scheffe post-hoc test to analyze changes in all parameters between all groups. One handed chest compression accounted for 14.0% and two handed chest compression accounted for 86.0%. Hands only CPR accounted for 71.7% and standard CPR (30:2) accounted for 28.3%. In order to perform the high quality CPR, as least three persons must be dispatched in the ambulance. The flexible management of manpower may improve the survival from the cardiac arrest. A systemic approach for educating and training EMT's in CPR is needed.

Effects of 60 Minutes Cardiopulmonary Resuscitation on Blood Lactic Acid Concentration, Heart Rate, and Rating of Perceived Exertion in Rescuers

  • Han, Seung-Eun;Ahn, Hee-Jeong;Shim, Gyu-Sik;Bang, Sung-Hwan;Song, Hyo-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.8
    • /
    • pp.195-202
    • /
    • 2022
  • In this study, when cardiopulmonary resuscitation continued for a long time, the rescuer's blood lactic acid concentration, heart rate, and rating of perceived exertion were measured to identify the change in the rescuer's fatigue. Data collection was conducted from July 5 to July 9, 2021, with a total of 24 students, 12 students department of special warfare medical non-commissioned officer, and 12 students department of emergency medical technology at D University, undergoing a two-person alternative chest compression resuscitation for 60 minutes. As a result of the study, the rescuer's blood lactic acid concentration, heart rate, rating of perceived exertion, and chest compression speed were significantly changed according to the duration of CPR (p<.001, p<.001, p<.001, p<.001). blood lactic acid concentrations at every measurement cycle (30 minutes, 40 minutes, 50 minutes, 60 minutes) showed a significant positive correlation with heart rate (r=.696, p<.001, r=.672, p<.001, r=.709, p<.001, r=.782, p<.001), there was also a significant positive correlation with the rating of perceived exertion (r=.476, p<).05, r=.426, p<.05, r=.470, p<.05, r=.470, p<.05). Therefore, monitoring the fatigue of rescuers using heart rate and rating of perceived exertion will be useful for maintaining high-quality chest compression in situations where cardiopulmonary resuscitation is required for a long time.

Difference of Cardiopulmonary Resuscitation Using Visual Feedback of Mirror (거울의 시각적 피드백을 활용한 심폐소생술의 차이)

  • Yun, Seong-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.438-440
    • /
    • 2018
  • Cardiac arrest is a series of conditions that occur when the heart is stopped, regardless of the cause. Cardiac arrest due to heart disease is included in the cause of death in korea every year and is unpredictable. One of the only ways to save a patient's life when a cardiac arrest is cardiopulmonary resuscitation is to maintain circulation through this procedure. The visual information is transmitted to the brain through the optic nerve. Among them, the mittor can see its movement and its shape, and it can be used for correction and analysis. Therefore compared the quality of chest compressions with visual information using mirrors. There was a significant difference in the mean depth of chest compressions($48.93{\pm}6.76$, $53.86{\pm}4.56$, <0.001), and there was also a difference in compression to relaxation ratio($0.87{\pm}0.13$, $0.96{\pm}0.10$, <0.002). There was also a significant difference in attitude awareness($4.93{\pm}0.85$, $8.14{\pm}1.38$, <0.001).

  • PDF

The effect of portal compression sensor on the quality of chest compressions during cardiopulmonary resuscitation (CPR): A mannequin based simulation study (심페소생술 시행 시에 휴대용 압박 센서 활용이 흉부압박의 질에 미치는 영향: 마네킹 기반 시뮬레이션 연구)

  • Yang, Hyun-Mo;Baeck, Kyung-Min;Kim, Kwang-Suk;Yoon, Byung-Gil;Kim, Jin-Woo;Kim, Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.744-750
    • /
    • 2013
  • This study is to collect a basic data of how Cardiopulmonary Resuscitation (CPR) procedure can influence to cardiac arrest patient with and without the Depth Device during the average transport time period. The data has achieved by comparing result sheet of CPR procedure by hands only versus with Depth Device by twenty 1st and 2nd class Emergency Medical Technician (EMT) from five different fire stations in city of Chong-Ju, and twenty Emergency Rescue major students who completed the BLS provide course. The experiment participators experienced loss of compression depth and rate increase over time. However, the CPR procedure with Depth Device shows that both EMT and students to allow maintaining both the compression depth and rate. The experiment leaves a positive result for CPR operators and considers being valuable domain for cardiac arrest patient.

Comparing the Effectiveness Between Typical Infant CPR method and Over-head CPR method : A Study of the Single-Person Rescuer Simulation Using a Manikin

  • Choi, Sung-Soo;Han, Seung-Tae;Yun, Seong-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.7
    • /
    • pp.151-157
    • /
    • 2020
  • This study is to find out the effectiveness by Infant CPR method of a single rescuer. It was conducted for 51 general public. And typical infant CPR method by a single rescuer and a new method, CPR with two thumb chest compressions wrapped in both hands over the head were compared. SPSS 22.0 was used as an analysis method and to compare the both CPR methods, Paired t-test was used. As a result of the study, the average chest compression depth(39.38±1.07 mm) by CPR with two thumb chest compressions wrapped in both hands over the head was significantly high(p<0.001). Ease of mouth-to-mouth resuscitation(p<0.001), convenience of CPR method(p<0.001), and finger pain level(p<0.001) had a significant difference. As for the preference of the CPR method, 80.4%(41 people) preferred CPR with two thumb chest compressions wrapped in both hands over the head. In this study, CPR with two thumb chest compressions wrapped in both hands over the head showed more effective results than typical CPR method. However, as a virtual study using mannequins, further research is needed to apply high-quality CPR methods to field.

A Systematic Review of the Mechanical CPR and Manual CPR on Out-of-Hospital Cardiac Arrest Occurring in High-rise Building

  • ChanHo, Lee;ByounGgil, Yoon;HongBeom, Ahn;YongSeok, Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.434-443
    • /
    • 2022
  • CPR in High-rise building is one of the challenging tasks to 119 paramedics, evacuating patient from the narrow and vertical area. This study was built to compare the method of mechanical CPR and manual CPR is to maximizing on-scene treatment time, and minimizing the hand-off time in cardiac arrest, transporting patient as fast as possible. The electronic data research (Science, Pubmed, Medline, Medline and 55 academic DB interworking) was conducted, and five articles were included by reviewing and excluding through the Covidence program and Review Manager version 5.4(Cochrane Collaboration). OHCA occurring on the higher floor indicates lower in survival. A total studies uniformly reported mechanical CPR is more effective during the high-rise building evacuation, than manual CPR in rate, depth, and hands-on time of chest compression. Use of mechanical CPR device is more suitable in case of High-rise building OHCA to improve the survival rate which is affected by high-quality CPR.