• 제목/요약/키워드: Quality of Radiation Characteristics

검색결과 224건 처리시간 0.029초

Effect of Atmospheric Pressure Plasma Jet on Inactivation of Listeria monocytogenes, Quality, and Genotoxicity of Cooked Egg White and Yolk

  • Lee, Hyun-Jung;Song, Hyun-Pa;Jung, Hee-Soo;Choe, Won-Ho;Ham, Jun-Sang;Lee, Jun-Heon;Jo, Cheo-Run
    • 한국축산식품학회지
    • /
    • 제32권5호
    • /
    • pp.561-570
    • /
    • 2012
  • The objective of this study was to evaluate the effects of an atmospheric pressure plasma (APP) jet on L. monocytogenes inactivation, quality characteristics, and genotoxicological safety of cooked egg white and yolk. APP treatment using He gas resulted in a 5 decimal reduction in the number of L. monocytogenes in cooked egg white, whereas that using $He+O_2$, $N_2$, and $N_2+O_2$ decreased the number further, and to undetectable levels. All treatments of cooked egg yolk resulted in undetectable levels of inoculated L. monocytogenes. There were no viable cells of total aerobic bacteria after APP treatment on day 0 while the control showed approximately 3-4 Log CFU/g. On day 7, the numbers of total aerobic bacteria had increased by approximately 3 log cycles in cooked egg white, but there were no viable cells in cooked egg yolk after 2 min of APP jet. APP treatment decreased the $L^*$-values of cooked egg white and yolk significantly on day 0. No significant sensory differences were found among the cooked egg white samples, whereas significant reductions in flavor, taste, and overall acceptability were found in cooked egg yolks treated with APP jets. SOS chromotest did not reveal the presence of genotoxic products following APP treatments of cooked egg white and yolk. Therefore, it can be concluded that APP jets can be used as a non-thermal means to enhance the safety and extend the shelf-life of cooked egg white and yolk.

Stereotactic Radiosurgery

  • Chung, Hyun-Tai;Lee, Dong-Joon
    • 한국의학물리학회지:의학물리
    • /
    • 제31권3호
    • /
    • pp.63-70
    • /
    • 2020
  • Stereotactic radiosurgery is one of the most sophisticated forms of modern advanced radiation therapy. Unlike conventional fractionated radiotherapy, stereotactic radiosurgery uses a high dose of radiation with steep gradient precisely delivered to target lesions. Lars Leksell presented the principle of radiosurgery in 1951. Gamma Knife® (GK) is the first radiosurgery device used in clinics, and the first patient was treated in the winter of 1967. The first GK unit had 179 cobalt 60 sources distributed on a hemispherical surface. A patient could move only in a single direction. Treatment planning was performed manually and took more than a day. The latest model, Gamma Knife® IconTM, shares the same principle but has many new dazzling characteristics. In this article, first, a brief history of radiosurgery was described. Then, the physical properties of modern radiosurgery machines and physicists' endeavors to assure the quality of radiosurgery were described. Intrinsic characteristics of modern radiosurgery devices such as small fields, steep dose distribution producing sharp penumbra, and multi-directionality of the beam were reviewed together with the techniques to assess the accuracy of these devices. The reference conditions and principles of GK dosimetry given in the most recent international standard protocol, International Atomic Energy Agency TRS 483, were shortly reviewed, and several points needing careful revisions were highlighted. Understanding the principles and physics of radiosurgery will be helpful for modern medical physicists.

Wide and Dual-Band MIMO Antenna with Omnidirectional and Directional Radiation Patterns for Indoor Access Points

  • Yeom, Insu;Jung, Young Bae;Jung, Chang Won
    • Journal of electromagnetic engineering and science
    • /
    • 제19권1호
    • /
    • pp.20-30
    • /
    • 2019
  • A wide-band multiple-input multiple-output (MIMO) antenna with dual-band (2.4 and 5 GHz) operation is proposed for premium indoor access points (IAPs). Typically, an omni-directional pattern is used for dipole antennas and a directional radiation pattern is used for patch antennas. In this paper, both antenna types were used to compare their performance with that of the proposed $2{\times}2$ MIMO antenna. We simulated and measured the performance of the MIMO antenna, including the isolation, envelope correlation coefficient (ECC), mean effective gain (MEG) for the IAPs, and the throughput, in order to determine its communication quality. The performance of the antennas was analyzed according to the ECC and MEG. The proposed antenna has sufficient performance and excellent characteristics, making it suitable for IAPs. We analyzed the communication performance of wireless networks using the throughput data of a typical office environment. The network throughput of an 802.11n device was used for the comparison and was conducted according to the antenna type. The results showed that the values of the ECC, MEG, and the throughput have unique characteristics in terms of their directivity, antenna gains, isolation, etc. This paper also discusses the communication performance of various aspects of MIMO in multipath situations.

국지 기상 특성에 따른 군산, 대구 및 포항의 대기질의 일변화 (Variations of Air Quality in Kunsan, Taegu, and Pohang due to the Characteristics of Local Weather)

  • 서기수;윤일희
    • 한국환경과학회지
    • /
    • 제6권6호
    • /
    • pp.613-628
    • /
    • 1997
  • Diurnal variations of air quality due to the characteristic features of local weather phenomena over Kunsan, Taegu, and Pohang are analyzed using various synoptic wand fields and the characteristics of local weather during the period of 1990 to 1992. The air pollutants analyzed are sulfur dioxide($SO2_$), nitrogen dioxide($NO_2$), and oxidants ($0_3$). The synoptic wind fields estimated at over the 850 hPa geopotential height are divided in terms of four wand directions and two wand speed categories for each season. The synoptic weather conditions are also classified Into two categories depending on the 850 hPa cloud amounts. The present study shows that the $SO_2$ concentration over Kunsan, and Taegu was maximum at the two or three hours after sunrise and second primary was three or flour hours after sunset. On the other hand, Its concentration over Kunsan was malnmum at 1900 LST or 2000 LST The $O_3$ concentration over the three cities shows Its mapdmum In the afternoon when the solar radiation is strong. The $NO_2$ concentration over Kansan shows in reverse proportion to the $O_3$ concentration over the Kunsan.

  • PDF

Calculation of X-ray spectra characteristics and kerma to personal dose equivalent Hp(10) conversion coefficients: Experimental approach and Monte Carlo modeling

  • Arectout, A.;Zidouh, I.;Sadeq, Y.;Azougagh, M.;Maroufi, B.;Chakir, E.;Boukhal, H.
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.301-309
    • /
    • 2022
  • This work aims to establish some X-ray qualities recommended by the International Standard Organization (ISO) using the half-value layer (HVL) and Hp(10) dosimetry approaches. The HVL values of the following qualities N-60, N-80, N-100, N-150 and N-250 were determined using various attenuation layers. The obtained results were compared to those of reference X-ray beam qualities and a good agreement was found (difference less than 5% for all qualities). The GAMOS (Geant4-based Architecture for Medicine-Oriented Simulations) radiation transport Monte Carlo toolkit was employed to simulate the production of X-ray spectra. The characteristics HVLs, mean energy and the spectral resolution of simulated spectra have been calculated and turned out to be conform to the ISO reference ones (difference less than the limit allowed by ISO). Furthermore, the conversion coefficients from air kerma to personal dose equivalent for simulated and measured spectra were fairly similar (the maximum difference less than 4.2%).

건축물 제배연시나리오 작성을 위한 구획실 발열특성 연구 (Study on Characteristics of Heat Release Rate in Compartment of Building for Scenario of Smoke Management)

  • 김정엽;신현준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.398-403
    • /
    • 2009
  • The theoretical bases on characteristics of heat release rate in compartment of building for scenario of smoke management are introduced and the numerical applications to simple compartment model are carried out. The growth stage which is important for smoke management design is modelled as t-squared fire curve including fire growth coefficient with related to growth rate. The conditions for the happening of flashover is presented such as $600^{\circ}C$ of temperature or $20kW/m^2$ of radiation heat flux. After the flashover happen, the fire in compartment changes to fully developed fire having the characteristics of ventilation-controlled fire. As the result of numerical analysis to simple compartment model, the time to reach 900K under ceiling for condition of medium growth is twice for condition of fast growth.

  • PDF

스테비아(Stevia rebaudiana Bert)의 아조돌연변이유기를 위한 기내유식물체의 방사선감수성 (Radiosensitivity of the in vitro Cultured Young Plants for Sport Mutation Induction of Stevia rebaudiana Bert)

  • 윤태영;김이엽;현경섭;조한직;이영일;주선아;오승철;김동섭;강시용;고정애
    • 방사선산업학회지
    • /
    • 제4권4호
    • /
    • pp.297-306
    • /
    • 2010
  • Due to the increasing incidence of diabetes, obesity and hypertensive, stevia has been placed great attentions as the sweetener to substitute sucrose in the world. Stevia was introduced to Korea in 1970's, but it has not been an attractive crop in that time. However, recently it has more attention for the natural food sweet additives. Because stevia have many problems for cultivation especially cultivar, seed germination, fertility, uniformity and glycoside quality, the sport mutation was attempted to in vitro plants for the improvement of some characteristics. The young in vitro plants was nursed on MS medium supplemented with $1mg\;l^{-1}\;GA_3$. Shoots of 10 cm height were irradiated with 0~200 Gy of gamma ray and the every node was separated and inoculated on MS basic medium. The lethality, number and length of shoot, numbers of node and branch were investigated for the evaluation of radiosensitivity. The optimum dose of gamma ray seemed to be around 80 Gy for the sport mutation induction in stevia. The lower node was more sensitive than higher node to radiation.

의료용 선형가속기의 소조사면에 대한 검출기 종류에 따른 평가 (Evaluation of the Small Field of for the Detector Type Medical Linear Accelerator)

  • 이동운;정강교;신귀순;조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.177-184
    • /
    • 2016
  • 최근 선형가속기를 이용한 방사선치료는 세기조절방사선치료, 정위적방사선치료 등이 널리 사용되고 있다. 이러한 방사선 치료기법은 일반적으로 역방향치료계획을 사용함으로써 소조사면을 제외하기 어렵다. 그러므로 소조사면의 선량특성에 관한 정확한 측정이 필요하다. 따라서 유효체적이 서로 다른 검출기를 이용하여 소조사면에 대한 깊이선량백분율, 빔측면도, 그리고 선량출력계수를 측정하여 각 검출기의 선량특성 평가하고자 하였다. 실험 결과 X-선 6 MV에너지에 대한 빔선질($PDD_{20}/PDD_{10}$)은 $10{\times}10cm^2$에서 Diode 검출기는 Pinpoint 검출기에 비해 2.4%로 높았다. 모든 조사면에서 유효체적이 작은 Diode 검출기가 다른 검출기들과 50%이상 작은 반음영을 보여 공간분해능이 우수한 것으로 평가되었다. 출력선량계수는 조사면 $2{\times}2cm^2$에서 Semiflex 검출기 다른 검출기에 비해 2%정도 적게 측정되기 시작해서 조사면 $1{\times}1cm^2$에서는 20%정도 차이를 보이며 유효성이 없는 것으로 판단된다. 조사면 $1{\times}1cm^2$에서 Diode 검출기와 Pinpoint 검출기의 측정값은 13%정도 차이를 보였다. 조사면 $3{\times}3cm^2$이하에서는 검출기의 유효체적에 따른 출력선량계수의 차이가 크므로 가능한 유효체적이 작은 검출기를 사용해야 될 것으로 사료된다.

파프리카와 매실 추출액을 첨가한 돈육포의 품질 특성 (Quality Characteristics of Pork Jerky Added with Capsicum annuum L. and Prunus mume Sieb. et Zucc. Extract)

  • 오종숙;박재남;김재훈;이주운;변명우;전순실
    • 한국식품영양과학회지
    • /
    • 제36권1호
    • /
    • pp.81-86
    • /
    • 2007
  • 돈육포에 수용성 파프리카 추출액과 매실 추출액 첨가량을 달리하여 육포의 품질 특성을 살펴보았다. 관능검사 결과 돈육포 제조를 위한 파프리카 및 매실추출액의 최적 첨가량은 파프리카추출액 0.5%와 매실추출액 3.5%로 나타났다. 천연추출액 즉 파프리카추출액 0.5%와 매실추출액 3.5%를 첨가한 돈육포를 실온에서 70일 간 저장하면서 품질 특성을 평가한 결과, 파프리카 및 매실추출액은 제조 직후 및 저장기간 동안 아질산염과 유사한 발색효과를 나타내었으며 천연추출액 처리군에서 무처리군보다 지질산화가 억제되어 아질산염 대체 물질의 효과를 보였다. 조직감 및 관능평가에서 아질산염은 품질 개선 효과가 없었으나, 파프리카 및 매실 추출액은 육포의 연화도를 증진시키고, 풍미와 맛의 기호도를 개선하여 아질산염 처리보다 우수한 품질의 돈육포를 제조할 수 있었다.

The Effect of Grid Ratio and Material of Anti-scatter Grid on the Scatter-to-primary Ratio and the Signal-to-noise Ratio Improvement Factor in Container Scanner X-ray Imaging

  • Lee, Jeonghee;Lim, Chang Hwy;Park, Jong-Won;Kim, Ik-Hyun;Moon, Myung Kook;Lim, Yong-Kon
    • Journal of Radiation Protection and Research
    • /
    • 제42권4호
    • /
    • pp.197-204
    • /
    • 2017
  • Background: X-ray imaging detectors for the nondestructive cargo container inspection using MeV-energy X-rays should accurately portray the internal structure of the irradiated container. Internal and external factors can cause noise, affecting image quality, and scattered radiation is the greatest source of noise. To obtain a high-performance transmission image, the influence of scattered radiation must be minimized, and this can be accomplished through several methods. The scatter rejection method using an anti-scatter grid is the preferred method to reduce the impact of scattered radiation. In this paper, we present an evaluation the characteristics of the signal and noise according to physical and material changes in the anti-scatter grid of the imaging detector used in cargo container scanners. Materials and Methods: We evaluated the characteristics of the signal and noise according to changes in the grid ratio and the material of the anti-scatter grid in an X-ray image detector using MCNP6. The grid was composed of iron, lead, or tungsten, and the grid ratio was set to 2.5, 12.5, 25, or 37.5. X-ray spectrum sources for simulation were generated by 6- and 9-MeV electron impacts on the tungsten target using MCNP6. The object in the simulation was designed using metallic material of various thicknesses inside the steel container. Using the results of the computational simulation, we calculated the change in the scatter-to-primary ratio and the signal-to-noise ratio improvement factor according to the grid ratio and the grid material, respectively. Results and Discussion: Changing the grid ratios of the anti-scatter grid and the grid material decreased the scatter linearly, affecting the signal-to-noise ratio. Conclusion: The grid ratio and material of the anti-scatter grid affected the response characteristics of a container scanner using high-energy X-rays, but to a minimal extent; thus, it may not be practically effective to incorporate anti-scatter grids into container scanners.