• 제목/요약/키워드: Quality monitoring stations

검색결과 209건 처리시간 0.019초

이동통신 기지국을 이용한 대기환경 모니터링 (A Method for monitoring air pollution using base stations)

  • 오현정;이재욱;백송훈
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2008년도 정보통신설비 학술대회
    • /
    • pp.205-208
    • /
    • 2008
  • This article presents a methodology for the monitoring of air pollution. All over the world, the interest in the environment has been continuously increasing. Unfortunately, much of this interest is due to emerging problems, such as the greenhouse effect and climate change. For this reason, research into carbon dioxide, which causes the greenhouse effect, is progressing rapidly. This article presents a method of measuring the level of carbon dioxide and other substances in the air through the utilization of mobile-networking base stations and measured data. First of all, sensors are attached at the appropriate position of the mobile-networking base stations. These sensors will measure the air quality in their respective positions, and send sensor data to an urban management center via network gateways and data-collecting systems. The measured data can be used for various purposes. In general, it can be used to measure the air quality, which can then be used as a basis for urban planning. The method described herein utilizes airpollution sensors that are attached to the base stations in different locations and at varying heights. The data obtained hereby will be applicable in many fields. At this time this is simply a methodology, however we hope that it will lead to a practical application.

  • PDF

대기오염도 실측에 의한 대기오염 자동측정망의 대표성 평가 (Evaluation of the Representativeness of Air Quality Monitoring Network in Seoul through Actual Measurement)

  • 전의찬
    • 환경영향평가
    • /
    • 제5권1호
    • /
    • pp.79-85
    • /
    • 1996
  • Simultaneous monitoring in many locations is necessary to evaluate the air quality and analyze future trend of a city, For this purpose, it is essential to install air pollution monitoring network. The first automatic air pollution monitoring network was introduced Seoul in 1973. As of 1995, 20 monitoring stations are now in operation. Concerning the management of the air pollution monitoring network, there was some argument among the relavant scholars, non-governmental organization(NGO) and the government organization. So far, there was no extensive evaluation and analysis about the network. The purpose of this study was to evaluate the representativeness of air quality monitoring network through actual measurement of the concentration of the air pollutant. The concentration of NOx was extensively measured widely in Seoul area three times using the TEA simple measuring technique. Even the judgement level for the area representativeness was lowered to 80%, Ssangmun-dong monitoring station tend to overestimate the pollutant concentration of the covered area. While, Sinlimdong monitoring station tend to underestimate the pollutant concentration of the covered area.

  • PDF

Air Pollution Trends in Japan between 1970 and 2012 and Impact of Urban Air Pollution Countermeasures

  • Wakamatsu, Shinji;Morikawa, Tazuko;Ito, Akiyoshi
    • Asian Journal of Atmospheric Environment
    • /
    • 제7권4호
    • /
    • pp.177-190
    • /
    • 2013
  • Air pollution trends in Japan between 1970 and 2012 were analyzed, and the impact of air pollution countermeasures was evaluated. Concentrations of CO decreased from 1970 to 2012, and in 2012, the Japanese environmental quality standard (EQS) for CO was satisfied. Concentrations of $SO_2$ dropped markedly in the 1970s, owing to use of desulfurization technologies and low-sulfur heavy oil. Major reductions in the sulfur content of diesel fuel in the 1990s resulted in further decreases of $SO_2$ levels. In 2012, the EQS for $SO_2$ was satisfied at most air quality monitoring stations. Concentrations of $NO_2$ decreased from 1970 to 1985, but increased from 1985 to 1995. After 1995, $NO_2$ concentrations decreased, especially after 2006. In 2012, the EQS for $NO_2$ was satisfied at most air quality monitoring stations, except those alongside roads. The annual mean for the daily maximum concentrations of photochemical oxidants (OX) increased from 1980 to 2010, but after 2006, the $98^{th}$ percentile values of the OX concentrations decreased. In 2012, the EQS for OX was not satisfied at most air quality monitoring stations. Non-methane hydrocarbon (NMHC) concentrations generally decreased from 1976 to 2012. In 2011, NMHC concentrations near roads and in the general environment were nearly the same. The concentration of suspended particulate matter (SPM) generally decreased. In 2011, the EQS for SPM was satisfied at 69.2% of ambient air monitoring stations, and 72.9% of roadside air-monitoring stations. Impacts from mineral dust from continental Asia were especially pronounced in the western part of Japan in spring, and year-round variation was large. The concentration of $PM_{2.5}$ generally decreased, but the EQS for $PM_{2.5}$ is still not satisfied. The air pollution trends were closely synchronized with promulgation of regulations designed to limit pollutant emissions. Trans-boundary OX and $PM_{2.5}$ has become a big issue which contains global warming chemical species such as ozone and black carbon (so called SLCP: Short Lived Climate Pollutants). Cobeneficial reduction approach for these pollutants will be important to improve both in regional and global atmospheric environmental conditions.

대기오염측정망 정도관리의 문제점과 개선방향 (Problems and Improvements in the Quality Control of the Air Monitoring Network)

  • 김덕승;박정호
    • 한국환경과학회지
    • /
    • 제29권8호
    • /
    • pp.847-855
    • /
    • 2020
  • This study presented problems and improvements in the quality control of an air monitoring network, using Gyeongnam as an example. 1) The effective utilization rate of the air monitoring was 95%, which showed good management, but the maximum of 2% was indicated by zero or detection limit among measurement data. 2) In the equivalence evaluation of PM2.5, the slope and intercept satisfy the evaluation criteria; however, 1% of the PM2.5/PM10 ratios were outliers. 3) All air monitoring stations meet the quality control standards; however, the management status is added to the quality inspection, management system is unified and the related budget is expanded, and systematic commission management is required.

CMAQ을 이용한 수도권 풍하지역의 고농도 오존 현상 모사 (A Simulation of High Ozone Episode in Downwind Area of Seoul Metropolitan Using CMAQ Model)

  • 이종범;송은영
    • 환경영향평가
    • /
    • 제15권3호
    • /
    • pp.193-206
    • /
    • 2006
  • Recently, high ozone episode occurred frequently in Korea. Moreover ozone episode occurred not only in the city but also in background area where local anthropogenic sources are not important. It analyzed frequency exceeding 100ppb ozone at air quality monitoring stations in Seoul and rural area during 1995-2004. This paper reports on the use of the Community Multiscale Air Quality (CMAQ) modelling system to predict hourly ozone levels. Domain resolutions of 30km, 10km, 3.333km (innermost) have been employed for this study. Summer periods in June 2004 have been simulated and the predicted results have been compared to data for metropolitan and rural air quality monitoring stations. The model performance has been evaluated with measured data through a range of statistical measures. Although, the CMAQ model reproduces the ozone temporal spatial trends it was not able to simulate the peak magnitudes consistently.

대기오염 측정 자료에 의한 지방도시의 대기환경규제지역 설정에 관한 타당성 검토 (Investigation on the Validation for Designating Air Quality Control Region among Provincial Cities by the Data Measured with Air Quality Monitoring Network)

  • 유미선;양성봉;우경빈
    • 한국환경과학회지
    • /
    • 제25권1호
    • /
    • pp.181-190
    • /
    • 2016
  • Regional air quality regulation is a system that allows the Minister of Environment to designate the local area as air quality control region where the concentrations of air pollutants are exceeding the environmental standards, and the local governments that administrate the regulated area have to develop and practise a plan for reducing the air pollutants. From the data observed yearly by the monitoring stations in 8 provincial cities with more than 0.5 million people was judged the compliance with air quality standards in each municipality for the period of 2003 to 2013. As the result of investigation on air pollutants concentrations of each city, it was found that there was no station that exceeds the ambient air quality standards of CO, $SO_2$ and 24-hour $NO_2$. But all municipalities exceeded the standards of 8-hour $O_3$, annual and 24-hour $PM_{10}$, and therefore 8 municipalities can be designated to be under the local air regulation. For the annual $NO_2$ were the monitoring sites necessary requirements for designation of the air quality regulation region in Cheongju, Cheonan, Daejeon and Gwangju area. Incase of 1-hour $O_3$, some of stations in Pohang, Cheongju, Cheonan and Changwon area were over the designation standards for the air quality control region.

한강수계 수질측정망 개선을 위한 목적 지향 설계 방안에 관한 연구 (Object-oriented Design for Water Quality Monitoring Networks in the Han River System)

  • 왕수균;나은혜;박석순
    • 대한환경공학회지
    • /
    • 제27권5호
    • /
    • pp.453-460
    • /
    • 2005
  • 우리나라에서는 1970년대 후반 이후 여러 기관의 상이한 필요성과 측정목적에 따라 별도의 측정망에서 수질측정이 이루어져 왔으며, 이러한 수질측정망의 분산된 운영으로 인한 일관된 측정 원칙의 결여는 수질자료의 관리에 많은 어려움을 야기하고 있다. 이는 과거 수질측정망의 확대 과정에서 과학적인 측정지점 선정 원칙이 결여된 채 수질 악화로 인한 관리의 필요성 증대에 따라 관리자의 경험과 주관적 판단에 의해 이루어졌기 때문이다. 따라서 본 연구에서는 장단기 수질변화 경향의 파악, 수질환경기준 위반사항 조사, 수질변화를 야기하는 외부 영향 파악, 용수이용 지원, 특정시기의 수질변화 규명 등 전통적인 측정망 운영 목적과 함께 오염총량관리제 시행에 따른 배수구역별 오염부하량을 산정, 과학적인 수질정책 수립을 위한 수질모델 적용 지원, 물관리정보화 지원 등 새로운 물관리 환경 변화에 따른 운영 목적에 대하여 이를 만족시킬 수 있는 수질자료 생산을 위한 수질측정망의 측정 지점 선정방법을 개발하고, 이를 한강수계에 적용하여 수질측정망의 개선 확충 방안을 제시하고자 하였다.

농촌마을 하천의 수질관리 시스템 - 시험유역 조사 및 시스템 설계 - (Water Quality Management System for a Farm Village Stream -watershed monitoring and the system design-)

  • 정하우;최진용
    • 농촌계획
    • /
    • 제2권2호
    • /
    • pp.109-117
    • /
    • 1996
  • The purpose of this study Is to develop water quality management system fort a farm village stream. The framework design of the system and the ecological monitoring of a test watershed were carried out, The system consists of GIS(Geographic Information System ), database, pollution source management, water quality and hydrologic analysis. Suri watershed located on Idong, Yongin city, Kyunggi Province, was selected as the test watershed for the application of the system. The fifteen's monitoring stations were chooses at up- and down-stream of the watershed. The results of an aquatic ecological monitoring were analyzed by the GPI(Group Pollution Index) method. The GPI revealed that water quality was varied within the stream. GPI and DO map for the watershed stream were developed, These maps facilitated to analyze the spatial distribution of the water quality.

  • PDF

다변량분석법을 이용한 금강 유역의 수질오염특성 연구 (Evaluation of the Geum River by Multivariate Analysis: Principal Component Analysis and Factor Analysis)

  • 김미아;이재관;조경덕
    • 한국물환경학회지
    • /
    • 제23권1호
    • /
    • pp.161-168
    • /
    • 2007
  • The main aim of this work is focus on the Geum river water quality evaluation of pollution data obtained by monitoring measurement during the period 2001-2005. The complex data matrix 19 (entire monitoring stations)*13 (parameters), 60 (month)*13 (parameters) and 20 (season)*13 (parameters) were treated with different multivariate techniques such as factor analysis/principal component analysis (FA/PCA). FA/PCA identified two factor (19*13) classified pollutant Loading factor (BOD, COD, pH, Cond, T-N, T-P, $NH_3$-N, $NO_3$-N, $PO_4$-P, Chl-a), seasonal factor (water temp, SS) and three Factor (60*13, 20*13) classified pollutant Loading factor (BOD, COD, Cond, T-N, T-P, $NH_3$-N, $NO_3$-N, $PO_4$-P), seasonal factor (water temp, SS) and metabolic factor (Chl-a, pH). Loadings of pollutant factor is potent influence main factor in the Geum river which is explained by loadings of pollutant factor at whole sampling stations (71.16%), month (52.75%) and season (56.57%) of main water quality stations. Result of this study is that pollutant loading factor is affected at Gongju 1, 2, Buyeo 1, 2, Gangkyeong, Yeongi stations by entire stations and entire month (Gongju 1, Cheongwon stations), April, May, July and August (buyeo 1) by month. Also the pollutant Loading factor is season gives an influence in winter (Gongju 1, buyeo 1) from main sampling stations, but Cheongwon characteristic is non-seasonal influenced. This study presents necessity and usefulness of multivariate statistic techniques for evaluation and interpretation of large complex data set with a view to get better information data effective management of water sources.

차세대 RNSS 감시국을 위한 고장 검출 알고리즘 개발 방안 (Development Approach of Fault Detection Algorithm for RNSS Monitoring Station)

  • 정다님;이수민;이찬희;김의호;최헌호
    • 한국항행학회논문지
    • /
    • 제28권1호
    • /
    • pp.1-14
    • /
    • 2024
  • 위치, 항법 및 시각정보 서비스를 제공하는 위성항법시스템은 위성시스템, 지상시스템, 사용자시스템으로 구성된다. 지상시스템의 구성요소인 감시국은 위성항법시스템의 서비스 제공 및 고장 검출을 위해, 위성항법 신호를 연속적으로 수집하고 위성의 SIS (signal-in-space) 고장과 수신기 및 다중반사파를 포함한 Local 고장과 같은 신호 이상을 검출하여 수신한 데이터와 검출 결과를 중앙처리국으로 전송하는 역할을 한다. 본 논문에서는 기존 위성항법시스템 감시국의 수신한 위성 신호에 대한 품질 판단 및 고장 검출을 위한 주요 모니터와 측정치 전처리 과정을 소개하고, 이를 활용하여 차세대 지역 위성항법시스템 (RNSS; regional navigation satellite system) 감시국의 구성요소와 아키텍처 및 알고리즘 개발 방안을 제시하였다.