• Title/Summary/Keyword: Quality evaluation

Search Result 14,126, Processing Time 0.048 seconds

The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery (Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2017
  • Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting $^{99m}TcO_4$ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.

  • PDF

Development of Artificial Pulmonary Nodule for Evaluation of Motion on Diagnostic Imaging and Radiotherapy (움직임 기반 진단 및 치료 평가를 위한 인공폐결절 개발)

  • Woo, Sang-Keun;Park, Nohwon;Park, Seungwoo;Yu, Jung Woo;Han, Suchul;Lee, Seungjun;Kim, Kyeong Min;Kang, Joo Hyun;Ji, Young Hoon;Eom, Kidong
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.76-83
    • /
    • 2013
  • Previous studies about effect of respiratory motion on diagnostic imaging and radiation therapy have been performed by monitoring external motions but these can not reflect internal organ motion well. The aim of this study was to develope the artificial pulmonary nodule able to perform non-invasive implantation to dogs in the thorax and to evaluate applicability of the model to respiratory motion studies on PET image acquisition and radiation delivery by phantom studies. Artificial pulmonary nodule was developed on the basis of 8 Fr disposable gastric feeding tube. Four anesthetized dogs underwent implantation of the models via trachea and implanted locations of the models were confirmed by fluoroscopic images. Artificial pulmonary nodule models for PET injected $^{18}F$-FDG and mounted on the respiratory motion phantom. PET images of those acquired under static, 10-rpm- and 15-rpm-longitudinal round motion status. Artificial pulmonary nodule models for radiation delivery inserted glass dosemeter and mounted on the respiratory motion phantom. Radiation delivery was performed at 1 Gy under static, 10-rpm- and 15-rpm-longitudinal round motion status. Fluoroscpic images showed that all models implanted in the proximal caudal bronchiole and location of models changed as respiratory cycle. Artificial pulmonary nodule model showed motion artifact as respiratory motion on PET images. SNR of respiratory gated images was 7.21. which was decreased when compared with that of reference images 10.15. However, counts of respiratory images on profiles showed similar pattern with those of reference images when compared with those of static images, and it is assured that reconstruction of images using by respiratory gating improved image quality. Delivery dose to glass dosemeter inserted in the models were same under static and 10-rpm-longitudinal motion status with 0.91 Gy, but dose delivered under 15-rpm-longitudinal motion status was decreased with 0.90 Gy. Mild decrease of delivered radiation dose confirmed by electrometer. The model implanted in the proximal caudal bronchiole with high feasibility and reflected pulmonary internal motion on fluoroscopic images. Motion artifact could show on PET images and respiratory motion resulted in mild blurring during radiation delivery. So, the artificial pulmonary nodule model will be useful tools for study about evaluation of motion on diagnostic imaging and radiation therapy using laboratory animals.

Precision evaluation of the treatment that used coordinates confirmation of couch in case of two forgets adjoined. (Couch의 좌표 확인을 이용한 치료 위치 이동의 정확성 평가)

  • Seo Jeong-min;Jeong Cheon-young;Park Young-hwan;Song Ki-won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.35-40
    • /
    • 2003
  • I. Purpose Confirming an error to be able to break out in a method to move couch manually while operator sees the skin marks on patient in case of curing head who got 2 targets adjoined, so we analyze coordinates price of couch, evaluate reproducibility and precision of change movements between targets. II. Materials and Methods In radiotherapy, for confirming errors in manual movements by operators by exchanging between two targets to treat patient head, we read coordinates price(vertical, longitudinal, lateral three directions of couch) shown on a monitor of LINAC( CL 2100, Varian, USA) in order to evaluate accuracy about the length that moved in time for moving couch manually. After reading movement length of coordinates recorded in three directions of all treatment, we compared distance between targets recorded in RTP(Pinnacle, ADAC, USA) with reading coordinates price of couch, setting actually done the same patient for ten times, coordinates were recorded, treated for evaluating averages and degrees of errors and standard deviations. III. Results In method to confirm skin marks of patient by operators' view and to move couch manually, average standard deviations of movements between two targets are vertical 1.4mm, longitudinal 0.9mm, lateral 2.2mm in each direction. As for the error in straight dimension, it is about 3.6mm averages and 5.1mm maximum. The average of errors in each directions was vertical 1mm, longitudinal 0.7mm, lateral 2.7mm. The greatest error broke out in lateral direction with $25\%$ of all cases ; to exceed an error average. IV. Conclusions If operators moved manually couch for changing target points, errors about 3.6mm average degrees occur. It is important that operators confirm the errors prices of actual couch coordinates for asking a correct movement between the targets adjoined each other ; in case of treatment demanding high precision like 3D conformal therapy or IMRT. Therefore, if we apply couch coordinates confirmation to reproducibility and to precision evaluation of treatment, it's expected that we can execute high-quality radiotherapy.

  • PDF

The Evaluation of Reconstructed Images in 3D OSEM According to Iteration and Subset Number (3D OSEM 재구성 법에서 반복연산(Iteration) 횟수와 부분집합(Subset) 개수 변경에 따른 영상의 질 평가)

  • Kim, Dong-Seok;Kim, Seong-Hwan;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 2011
  • Purpose: Presently in the nuclear medicine field, the high-speed image reconstruction algorithm like the OSEM algorithm is widely used as the alternative of the filtered back projection method due to the rapid development and application of the digital computer. There is no to relate and if it applies the optimal parameter be clearly determined. In this research, the quality change of the Jaszczak phantom experiment and brain SPECT patient data according to the iteration times and subset number change try to be been put through and analyzed in 3D OSEM reconstruction method of applying 3D beam modeling. Materials and Methods: Patient data from August, 2010 studied and analyzed against 5 patients implementing the brain SPECT until september, 2010 in the nuclear medicine department of ASAN medical center. The phantom image used the mixed Jaszczak phantom equally and obtained the water and 99mTc (500 MBq) in the dual head gamma camera Symbia T2 of Siemens. When reconstructing each image altogether with patient data and phantom data, we changed iteration number as 1, 4, 8, 12, 24 and 30 times and subset number as 2, 4, 8, 16 and 32 times. We reconstructed in reconstructed each image, the variation coefficient for guessing about noise of images and image contrast, FWHM were produced and compared. Results: In patients and phantom experiment data, a contrast and spatial resolution of an image showed the tendency to increase linearly altogether according to the increment of the iteration times and subset number but the variation coefficient did not show the tendency to be improved according to the increase of two parameters. In the comparison according to the scan time, the image contrast and FWHM showed altogether the result of being linearly improved according to the iteration times and subset number increase in projection per 10, 20 and 30 second image but the variation coefficient did not show the tendency to be improved. Conclusion: The linear relationship of the image contrast improved in 3D OSEM reconstruction method image of applying 3D beam modeling through this experiment like the existing 1D and 2D OSEM reconfiguration method according to the iteration times and subset number increase could be confirmed. However, this is simple phantom experiment and the result of obtaining by the some patients limited range and the various variables can be existed. So for generalizing this based on this results of this experiment, there is the excessiveness and the evaluation about 3D OSEM reconfiguration method should be additionally made through experiments after this.

  • PDF

Evaluation of Feed Values for Imported Hay Using Near Infrared Reflectance Spectroscopy (근적외선분광법을 이용한 수입 건초의 사료가치 평가)

  • Park, Hyung Soo;Kim, Ji Hye;Choi, Ki Choon;Oh, Mirae;Lee, Ki-Won;Lee, Bae Hun
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.39 no.4
    • /
    • pp.258-263
    • /
    • 2019
  • Near infrared reflectance spectroscopy (NIRS) has become increasingly used as a rapid and accurate method of evaluating some chemical compositions in forages. The objective of this study was to evaluate the potential of NIRS, applied to imported forage, to estimate the moisture and chemical parameters for imported hays. A population of 392 imported hay representing a wide range in chemical parameters was used in this study. Samples of forage were scanned at 1 nm intervals over the wavelength range 680-2500nm and the optical data was recorded as log 1/Reflectance(log 1/R), which scanned in intact fresh condition. The spectral data were regressed against a range of chemical parameters using partial least squares(PLS) multivariate analysis in conjunction with spectral math treatments to reduced the effect of extraneous noise. The optimum calibrations were selected based on the highest coefficients of determination in cross validation(R2) and the lowest standard error of cross-validation(SECV). The results of this study showed that NIRS predicted the chemical parameters with very high degree of accuracy. The R2 and SECV for imported hay calibration were 0.92(SECV 0.61%) for moisture, 0.98(SECV 0.65%) for acid detergent fiber, 0.97(SECV 0.40%) for neutral detergent fiber, 0.99(SECV 0.06%) for crude protein and 0.97(SECV 3.04%) for relative feed value on a dry matter(%), respectively. Results of this experiment showed the possibility of NIRS method to predict the moisture and chemical composition of imported hay in Korea for routine analysis method to evaluate the feed value.

Strategies for Public Health Service Development in the Times of Local Autonomy (지방자치시대의 공공보건사업 발전 전략)

  • 박정한
    • Health Policy and Management
    • /
    • v.12 no.3
    • /
    • pp.1-22
    • /
    • 2002
  • Health is a fundamental human right and a sine qua non for happiness of people and for national development. Government has a responsibility for the provision of health services for their people. Recent changes of disease pattern, i.e. decrease of Infectious diseases and increase of chronic and degenerative diseases Including cancer and cardiovascular diseases, together with universal coverage of health insurance and improved living standard have prompted medical care utilization and skyrocketed the national health expenses. The goal of national health policy is improving the quality of life through the betterment of health level. To achieve this goal it is necessary to establish a healthcare system for lifetime, to improve the efficiency of healthcare delivery system, and to strengthen the public health services for disease prevention and health promotion. The current public health service programs are Inefficient due to an inconsistent policy for health service program, lack of health information system, irrational health program planning and evaluation, and Inadequate training of health workers. Local government has a legal responsibility for health service program planning and promoting the competence of health workers. Thus, municipal and provincial health departments should expand their roles and strengthen their function. The strategies for developing public health service programs at local level are ${\circled}1$ stipulating the goals of health policy, ${\circled}2$ promoting the ability for health program planning and evaluation, ${\circled}3$ establishing health information and surveillance system, ${\circled}4$ training of health workers, ${\circled}5$ establishing an institution for health information management and training of health workers, and ${\circled}61$ collaboration with local universities.

Research of Statistical Model for Genetic Evaluation of Hanwoo Carcass Traits (한우 도체형질의 유전능력평가를 위한 통계모형 탐색)

  • Koo, Yang-Mo;Kim, Si-Dong;Kim, Jung-Il;Song, Chi-Eun;Lee, Ki-Hwan;Jeoung, Yeoung-Ho;Lee, Jae-Youn;Jang, Hyun-Gi;Park, Byoung-Ho;Choi, Te-Jong;Cho, Kwang-Hyun;Lee, Seung-Soo;Lee, Jung-Gyu;Kim, Hyo-Sun
    • Journal of Animal Science and Technology
    • /
    • v.53 no.4
    • /
    • pp.283-288
    • /
    • 2011
  • This study was conducted to study the environment effects on live weight, carcass weight, dressing percentage, eye muscle area, backfat thickness, and marbling score, which are the carcass traits of Hanwoo, based on the estimates and all the possible regression for the selection of variable and significance test for 231,382 heads that underwent the carcass measurements. The average and standard deviation for the live weight, carcass weight, dressing percentage, eye muscle area, backfat thickness, and marbling score were 654.79${\pm}$91.61 kg, 362.30${\pm}$67.15 kg, 59.52${\pm}$0.03%, 81.79${\pm}$12.21 $cm^2$, 11.39${\pm}$5.40 mm, 4.38${\pm}$2.29, respectively. The live weight, carcass weight, dressing percentage, eye muscle area, backfat thickness, and marbling score for cow were 532.79${\pm}$78.38 kg, 313.40${\pm}$44.90 kg, 56.50${\pm}$0.03%, 75.24${\pm}$10.69 $cm^2$, 11.82${\pm}$5.10 mm, 4.30${\pm}$2.06, respectively, while for bull were 619.74${\pm}$93.27 kg, 376.89${\pm}$48.62 kg, 58.61${\pm}$0.02%, 85.61${\pm}$10.46 $cm^2$, 5.64${\pm}$2.71 mm, 1.41${\pm}$0.83, respectively, and for steer were 681.78${\pm}$70.72 kg, 415.23${\pm}$49.43 kg, 60.19${\pm}$0.02%, 88.29${\pm}$10.27 $cm^2$, 12.71${\pm}$5.23 mm, 5.42${\pm}$1.99, respectively. In the environmental variables selection based on the variables selection method, the examination by carcass traits suggested that the most appropriate model could be determined when five variables were selected for the live weight, carcass weight, dressing percentage, eye muscle area, and four variables for backfat thickness, and marbling score. When they were considered at a time altogether based on multiple traits, it was deemed to be desirable to insert all five variables into the variables for analysis. In addition, high significance was found by carcass traits.

Effect of raw soy flour addtion to Jeung-Pyun pizza on fermentation time and viscosity of batters and texture and general desirability of Jeung-Pyun pizza (날콩가루를 첨가한 증편 피자판 개발에 관한 연구)

  • Yoon, Sun;Lee, Chun-Ja; Park, Hye-Won;Myoung, Chun-Ok;Choi, Eun-Jung;Lee Ji-Jung
    • Korean journal of food and cookery science
    • /
    • v.16 no.3
    • /
    • pp.267-271
    • /
    • 2000
  • The present study was designed to develop the standardized formula for the preparation Jeung-Pyun with added raw soy flour and to investigate the applicability of Jeung-Pyun as the substitute of regular pizza crust made with wheat flour. The effect of adding raw soy flour at 3%, 5% level on fermentation time and viscosity of batters and texture and general desirability of Jeung-Pyun pizza were also studied. As the level of raw soy flour was increased the time required for 1 st and 2nd fermentation decreased and viscosity of batters increased significantly. Jeung-Pyun crust after steaming found to have appropriate texture and form for a substitute of wheat flour pizza crust. Texture parameters determined by QST showed that Jeung-Pyun crust with added raw soy flour had lower values in hardness, cohesiveness and gumminess without any significant difference. However, chewiness of 5% raw soy flour group was significantly lower than control group. Texture of Jeung-Pyun crust and general desirability of Jeung-Pyun pizza were determined by sensory evaluation. Textural parameters of Jeung-Pyun crust were evaluated on the basis of hardness, cohesiveness, adhesiveness, tenderness and wetness. As a result of sensory evaluation Jeung-Pyun crust made with 5% raw soy flour had significant lower values in hardness, cohesiveness, tenderness and wetness than the control. However, the textural parameters between control and 3 % raw soy flour group were not significantly different. Jeung-Pyun pizza with topping were evaluated by sensory panel. Jeung-Pyun pizza made with 3% raw soy flour received the highest score in apperance and general desirability without any significant difference. 5% raw soy flour group had significantly lower score in general desirability among 3 treatment groups. In conclusion, Jeung-Pyun crust made by traditional Jeung-Pyun preparation method will be a good alternative to replace wheat flour pizza crust. Adding raw soy flour at 3% level did not affect the quality of Jeung-Pyun crust and had an effect of promoting fermentation. Jeung-Pyun Pizza crust was expected to have tender texture and slower retrogradation rate than regular pizza crust with wheat flour.

  • PDF

Emergy Evaluation Overview of the Natural Environment and Economy of the Han River basin in Korea (한강유역의 자연환경과 사회경제활동에 대한 에머지 평가 - 한강유역 및 한강하구 관리를 위한 정책제언 -)

  • Kang, Dae-Seok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.3
    • /
    • pp.138-147
    • /
    • 2007
  • An emergy concept was used to evaluate the environment and economy of the Han River basin in Korea and to suggest policy perspectives far the sustainable utilization of its environment and associated estuarine ecosystem. The economy of the basin used $5.19{\times}10^{23}\;sej/yr$ of emergy in 2005. The economy of the Han River basin was heavily dependent on outside energy sources from foreign countries and other parts of Korea, with internal sources, renewable and nonrenewable, contributing only 15.6% to the total emergy use. The basin's trade balance in terms of emergy showed trade surplus, whereas there was a deficit in monetary terms. The population of the Han River basin was far greater than the carrying capacity calculated using the emergy flow, with renewable carrying capacity only at 1.8% of the basin's population and developed carrying capacity at 14.3%. The economy of the basin imposed a substantial stress on its environment, with an environmental loading ratio of 54.8. Overall, the economy of the Han River basin was not sustainable with an emergy sustainability of 0.02. These are reflected in lower quality of living expressed in the emergy term than the national average. Deconcentration of population and economic activities is needed to reduce environmental stress on the environment of the basin and its valuable estuarine ecosystem. Policies to restore ecosystem productivity of the basin are also needed to ensure the sustainability of the basin's economic activities and the sustainable utilization of the Han River estuary. In this regard, it is urgently needed for the Korean government to implement sustainable management measures for the Han River estuary, a well-preserved, productive natural estuarine ecosystem in Korea.

  • PDF

Comparative Analysis of Ecological Health Conditions Before and After Ecological Restoration in Changwon Stream and Nam Stream (창원천.남천에서 생태복원 전.후의 생태건강도 비교평가)

  • Kim, Hyun-Jeong;Lee, Sang-Jae;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.307-318
    • /
    • 2010
  • This study was to analyze the ecological conditions, based on physical habitat, chemical, and biological conditions before (2006, 2007) and after ecological restoration (2009) in five sites of Changwon Stream (CS) and six sites of Nam Stream (NS), respectively, and then to compare ecological health between the two period. The analysis of ecological health was based on the multimetric models of Index of Biological Integrity (IBI) and Qualitative Habitat Evaluation Index (QHEI) along with water chemistry in the streams. For the study, the models of IBI and QHEI were modified as 8 and 11 metric attributes, respectively. For the evaluations, the survey was conducted in the period of 2006~2007 before the restoration and in 2009 after the restoration by the city. Chemical conditions, based on conductivity, in both streams showed a typical longitudinal declines along the axis of the upstream-to-downstream. There were no significant differences (p>0.05) in water quality between the two periods. Values of IBI in the CS and NS averaged 21.6 and 19.7, respectively, indicating a C grade in the criteria of Ministry of Environment, Korea, and there was no significant differences in the IBI between the two periods. Values of QHEI after the restoration averaged 29.2 and 63.2 in the CS and NS, respectively and the values decreased markedly especially, in the NS (35.3) after the restoration. The habitat disturbance was mainly attributed to destructions (i.e., the narrower width of riparian vegetation and higher substrate exposure by the air) of artificial materials by massive flood in 2009. Overall, our results suggest that the restoration was not effective in the two streams between the two periods, even if the budget was used a lot and that such ecological restoration, not considered the natural disaster, may not effect for the stream restoration.