This paper introduces a new technique that reduces the search times and Improves the accuracy of motion estimation using high temporal and spatial correlation of motion vector. Instead of using the fixed first search Point of previously proposed search algorithms, the proposed method finds more accurate first search point as to compensating searching area using high temporal and spatial correlation of motion vector. Therefore, the main idea of proposed method is to find first search point to improve the performance of motion estimation and reduce the search times. The proposed method utilizes the direction of the same coordinate block of the previous frame compared with a block of the current frame to use temporal correlation and the direction of the adjacent blocks of the current frame to use spatial correlation. Based on these directions, we compute the first search point. We search the motion vector in the middle of computed first search point with two fixed search patterns. Using that idea, an efficient adaptive predicted direction search algorithm (APDSA) for block matching motion estimation is proposed. In the experimental results show that the PSNR values are improved up to the 3.6dB as depend on the Image sequences and advanced about 1.7dB on an average. The results of the comparison show that the performance of the proposed APDSA algorithm is better than those of other fast search algorithms whether the image sequence contains fast or slow motion, and is similar to the performance of the FS (Full Search) algorithm. Simulation results also show that the performance of the APDSA scheme gives better subjective picture quality than the other fast search algorithms and is closer to that of the FS algorithm.
A commercial ion chamber matrix was examined the characteristics and its performance for radiotherapy qualify assurance. The device was the I'mRT 2D-MatriXX (Scanditronix-Wellhofer, Schwarzenbruck, Germany). The 2D-MatriXX device consists of a 1020 vented ion chamber array, arranged in $24{\times}24cm^2$ matrix. Each ion chamber has a volume of $0.08cm^3$, spacing of 0.762 cm and minimum sampling time of 20 ms. For the investigation of the characteristics, dose linearity, output factor, short-term reproducibility and dose rate dependency were tested. In the testing of dose linearity. It has shown a good signal linearity within 1% in the range of $1{\sim}800$cGy. Dose rate dependency was found to be lower than 0.4% (Range: 100-600 Mu/min) relative to a dose rate of 300 Mu/min as a reference. Output factors matched very well within 0.5% compared with commissioned beam data using a ionization chamber (CC01, Scanditronix-Wellhofer, Schwarzenbruck, Germany) in the range of field sizes $3{\times}3{\sim}24{\times}24cm^2$. Short-term reproducibility (6 times with a interval of 15 minute) was also shown a good agreement within 0.5%, when the temperature and the pressure were corrected by each time of measurement. in addition, we compared enhanced dynamic wedge (EDW, Varian, Palo Alto, USA) profiles from calculated values in the radiation planning system with those from measurements of the MatriXX. Furthermore, anon-uniform IMRT dose fluence was tested. All the comparison studies have shown good agreements. In this study, the MatriXX was evaluated as a reliable dosimeter, and it could be used as a simplistic and convenient tool for radiotherapy qualify assurance.
Jo, Myung-Hee;Byun, Myeung-Sub;Sim, Jun-Seok;Jang, Sung-Hyun
Journal of the Korean Association of Geographic Information Studies
/
v.17
no.3
/
pp.175-194
/
2014
This study attempts to identify the spatial distributions of Achnanthes convergens, and elucidate the environmental factors that affect the Periphyton diatom habitat. Data in 250 points of Nakdong river basin are collected between April(primary) and September(secondary) 2012, with the National Institute of Environmental Research's support. We define "clean area" over 10% of Achnanthes convergens appearance, and the others as "non-clean areas". Spatial statistics of Kriging, Hotspot, LISA are used in this study. Results show that 1) 56 points are identified as clean areas in the primary survey, while 41 points are discovered in the following survey; 2) using water quality variables, density of turbidity(clean $101.83{\mu}s/cm$; non-clean $598.48{\mu}s/cm$) and conductivity(clean 1.95 NTU; nonclear 5.58 NTU) are five-fold lower in clean-areas; 3) Habitat and Riparian Factors in Nakdong basin illustrate that natural sand bar, diversity of velocity, sediment condition, levee material, riverside land affect Achnanthes convergens; 4) Hotspots of Achnanthes convergens are located in watersheds, including upper Andong Dam, upper Imha dam, Wi-cheon, Miryang river, Nam river and Hwang river whereas mainstream/downstream of Nakdong river and Keumho river watershed are shown as coldspots.
Shin, Jung-Ah;Chun, Ji Yeon;Lee, Junsoo;Shin, Ki Yong;Lee, Soon Kyu;Lee, Ki-Teak
Journal of the Korean Society of Food Science and Nutrition
/
v.42
no.12
/
pp.1949-1957
/
2013
The contents of ${\beta}$-carotene and retinol in processed and restaurant foods, such as Korean noodles, mandus, rice cakes and bread products, were quantified by high-performance liquid chromatography (HPLC) with UV/visible and fluorescence detector, respectively. Samples were collected from different local areas (i.e. Gangwon-do, Gyeonggi-do, Gyeongsang-do, Seoul, Jeolla-do, and Chungcheong-do). After homogenization, samples were hydrolyzed by direct alkali saponification; thereafter, fat-soluble components were extracted by a mixture of n-hexane/ethylacetate (85:15, v/v), containing 0.01% butylated hydroxytoluene (BHT). ${\beta}$-carotene and retinol contents in infant formula used as an in-house material for the analytical quality control. Among 14 Korean noodles, high contents of ${\beta}$-carotene were found in Bibim-Guksu (average 442.43 ${\mu}g/100g$) and Jjolmyeon (average 301.39 ${\mu}g/100g$). In 4 Korean mandus, the highest contents of ${\beta}$-carotene was determined in Kimchi-mandu (average 197.64 ${\mu}g/100g$), resulting in 33.3 RE of the converted vitamin A. Among 12 Korean rice cakes, Maeun-Tteokbokki and Modm-Chaltteok contained relatively high content of ${\beta}$-carotene with 205.11 and 41.33 ${\mu}g/100g$, respectively, while retinol was detected only in Maeun- Tteokbokki (1.65~10.45 ${\mu}g/100g$). In addition, among 8 bread products, 77.3 RE of pastry, 51.2 RE of buttercream- bread, and 41.4 RE of morning roll were found as the contents of the converted vitamin A.
KSCE Journal of Civil and Environmental Engineering Research
/
v.33
no.5
/
pp.2021-2031
/
2013
Due to the rapid economic growth within the nation, the quality of life of individuals have improved dramatically. The scope of living activities of individuals have also extended, resulting in a rapidly increasing demand for automobiles. The number of vehicles registered in Korea is rapidly increasing and will reach 188.71 million as of December 2012. Compared to the registered residents of 50.94 million provided by the Ministry of Public Administration and Security, the registered population reflects about 4 people per every automobile. Due to the high demands for vehicles, the demands for parking lots in collective housing and businesses are also increasing. In reality, the current state of expansion of parking lots are underground, due to the limited available space on ground level. Specifically, the slope of a parking lot cannot exceed 17% linear slope and 14% curved slope according to the 'parking lot laws', however studies show that the driver feels at risk for safety when stopped on the parking ramp while driving in the parking lot. This study seeks to examine the suitability of parking lot ramps, concerning the safety aspects of the driver. First, the ramp type was categorized as linear or curved, then test drives were performed based on variations of slopes, slant distances, directions and points. A survey was administered to the driver after the completion of the test drive, in order to element design for an ideal ramp. In the case of curved ramp, the results of the estimate suggests a counterclockwise, slope at a maximum of 12% incline. The maximum slope for a linear ramp was analyzed to be between 13~14%, suggesting that slope greater than 15% need to be eliminated. In conclusion, it is anticipated that the element design parking ramp reported in this study will help to serve as a reference for future parking lot related guidelines, and provide cost effective traffic safety mechanisms in future parking lot businesses to follow.
Radiation treatment techniques using photon beam such as three-dimensional conformal radiation therapy (3D-CRT) as well as intensity modulated radiotherapy treatment (IMRT) demand accurate dose calculation in order to increase target coverage and spare healthy tissue. Both jaw collimator and multi-leaf collimators (MLCs) for photon beams have been used to achieve such goals. In the Pinnacle3 treatment planning system (TPS), which we are using in our clinics, a set of model parameters like jaw collimator transmission factor (JTF) and MLC transmission factor (MLCTF) are determined from the measured data because it is using a model-based photon dose algorithm. However, model parameters obtained by this auto-modeling process can be different from those by direct measurement, which can have a dosimetric effect on the dose distribution. In this paper we estimated JTF and MLCTF obtained by the auto-modeling process in the Pinnacle3 TPS. At first, we obtained JTF and MLCTF by direct measurement, which were the ratio of the output at the reference depth under the closed jaw collimator (MLCs for MLCTF) to that at the same depth with the field size $10{\times}10\;cm^2$ in the water phantom. And then JTF and MLCTF were also obtained by auto-modeling process. And we evaluated the dose difference through phantom and patient study in the 3D-CRT plan. For direct measurement, JTF was 0.001966 for 6 MV and 0.002971 for 10 MV, and MLCTF was 0.01657 for 6 MV and 0.01925 for 10 MV. On the other hand, for auto-modeling process, JTF was 0.001983 for 6 MV and 0.010431 for 10 MV, and MLCTF was 0.00188 for 6 MV and 0.00453 for 10 MV. JTF and MLCTF by direct measurement were very different from those by auto-modeling process and even more reasonable considering each beam quality of 6 MV and 10 MV. These different parameters affect the dose in the low-dose region. Since the wrong estimation of JTF and MLCTF can lead some dosimetric error, comparison of direct measurement and auto-modeling of JTF and MLCTF would be helpful during the beam commissioning.
User-Centered Design Approach plays important role in dealing with usability issues for developing modern technology products. Yet it is still questionable whether the User-Centered approach is enough for the development of successful consumer contents since the User-Centered Design is originated from the software engineering field where meeting customers' functional requirement is the most critical aspect in developing a software. However, modern consumer market is already saturated and in order to meet ever increasing consumer requirements, the User-Centered Design approach needs to be expanded. As a way of incorporating the User-Centered Approach into the consumer product development, Jordan suggested the 'Pleasure-based Approach' in industrial design field, which usually generates multi-dimensional user requirements: 1)physical, 2)cognitive, 3)identity and 4) social. It is the current tendency that many portal and community service providers focus on fulfilling both functional and emotional needs for users when developing new items, contents and services. Previously fulfilling consumers' emotional needs solely depend on visual designer's graphical sense and capability. However, taking the customer-centered approach on withdrawing consumers' unknown needs is getting critical in the competitive market environment. This paper reviews different types of user research techniques and categorized into 6 ways based on Kano(1992)'s product quality model. Based on his theory, only performance factors, such as suability, can be identified through the user-centered design approach. The user-centered design approach has to be expanded to include factors include personality, sociability, pleasure, and so on. In order to identify performance as well as excellent factors through user research, a user-research framework was established and tested through the case study, which is ' the development of new online service for teens '. The results of the user research were summarized at the end of the paper and the pros and cons of each research techniques were analyzed.
Park, Jung-Im;Kim, Young-Kyun;Chung, Mi-Hee;Song, Mi-Young;Lee, Sang-Ho;Chon, Tae-Soo;Lee, Kun-Seop
Korean Journal of Environmental Biology
/
v.24
no.3
/
pp.230-239
/
2006
Nutrient over-enrichment as a consequence of anthropogenic loading leads to eutrophication, which has the detrimental effects on river and stream ecosystems. To examine dynamics of factors causing cultural eutrophication in a over-licked mountain stream due to anthropogenic loading, physicochemical parameters were measured from 5 stations in the upper Daecheon stream, Busan, from January 2002 to May 2003. The five study sites were located along the stream gradient. DC1 is upper most clean site, and DC5 is located at the lowest area. Wastewater was released into the stream from just upstream of DC2 site. Water column ammonium and phosphate concentrations were higher during winter than other seasons, while water column nitrate +nitrite concentration did not show clear seasonal variation. Water column ammonium, nitrate+nitrite and phosphate concentrations were lowest at DC1 and highest at DC2 in which waste water loading occurred. TOC and DOC, conductivity, turbidity, and BOD in the water column were also increased drastically at DC2, and then decreased at DC5. Sediment pore water phosphate concentrations during winter and spring were higher than those in summer and fall, while sediment pore water ammonium and nitrate +nitrite concentrations showed no seasonal trend. Sediment pore water ammonium and phosphate concentration were also increased at DC2 and slightly decreased at DC5, while sediment pore water nitrate+nitrite concentration was highest at DC5. Organic matter and inorganic nutrients at up-stream of Daechon stream significantly increased as a result of wastewater discharge, and the nutrient concentrations decreased at low-stream suggesting self-purification ability of the stream.
Kim, Yoo Gon;Lee, Woo Jong;Won, Chan Hee;Shin, Chul Soo
Analytical Science and Technology
/
v.25
no.6
/
pp.483-491
/
2012
This study is to investigate the issues on how to secure stability during the purification process for the production of recombinant protein A. The final recombinant protein A is produced by passing through the cation exchange column (SP) and the anion-exchange column (Q) during the production process, for which the samples produced by the step-by-step processes can be exposed to trouble in securing stable storage in case the next process cannot be taken within the proper time period. Accordingly, this study aims to evaluate the proper storage conditions and length of time when storing samples produced in the production process. That is, in this study, how to store fair samples, how long the storage period should be set up, and how to evaluate the security of its quality depending on time are dealt with. The items to be experimented with were enodotoxin, SDS-PAGE, HPLC purity and concentration. Experimental results showed that after passing the cation exchange column, when stored at $4^{\circ}C$ or room temperature, SDS-PAGE showed a major band, endotoxin is 5.0 Eu/mg or less, and concentration is on average of 8.21 to 8.24 mg/mL and RSD% 0.10~0.62%. In addition, HLPC purity showed somewhat stable results; at the HPLC purity 214 nm, the average is 99.24% to 99.37% and RSD% is 0.22~0.29%, while the average is 89.72% to 89.80% and RSD% 0.62~1.26% at 280 nm. On the contrary, after passing the anion exchange column, when stored at $4^{\circ}C$ or room temperature, SDS-PAGE revealed the major band, endotoxin is 0.5 Eu/mg or less, and concentration is on average of 5.59 mg/mL and RSD% 0.03~0.10%. when it comes to HLPC purity, the result showed that at the HPLC purity 214 nm, the average is 99.74% and RSD% is 0.10~0.11%, while the average is 96.16% to 96.85% and RSD% 0.72~1.13%. In conclusion, the stability of fair samples of recombinant protein A during the manufacturing process could be obtained without substance decomposition for 7~8 days at $4^{\circ}C$ or 20~21 days at room temperature.
Properties and frying performance of domestic rice bran oil were studied. For this purpose, the analyses on the following characteristics were performed and their comparison with the characteristics of soybean oil was made: fatty acid composition, glycerides, composition, acid value, specific gravity, color, petroleum ether insoluble oxidized fatty acid, viscosity, smoke point, foam test, and water solubility. The results were as follow: 1) Fatty acid composition of domestic rice bran oil by gas chromatography was same as perviously reported, and similar to the fatty acid composition of the rice bran oil in foreign countries. Also the glyceride composition of domestic rice bran oil was analyzed by the methods of TLC, column chromatography, and high performance liquid chromatography. The results were monoglyceride ranged from one to four percent; diglyceride 30-30% and triglyceride 66-80%. Consequently, the composition was proven completely different from that of the other edible oils. 2) The high contents of mono-glyceride in rice bran oil resulted in high values of specific gravity and water-solubility respectively. However, high contents mono glyceride and diglyceride indicated little affection to changes of acid value, color, petroleum ether insoluble oxidized fatty acid, and smoke point on frying. 3) Because of low contents of linoleic acid, domestic rice bran oil was estimated stable on frying, whereas soybean oil was easily polymerized. 4) A serious foaming and low smoke point on Frying in domestic rice bran oil were caused by its impurities. It seems that monoglyceride and diglyceride had little relation with foaming and smoke point. 5) Oils with serious foaming and low smoke point on frying caused a substantial quality loss in terms of flavor and appearance of fried materials.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.