• Title/Summary/Keyword: Quality control standards

Search Result 501, Processing Time 0.027 seconds

Optimum Water Quality Contral of River Basin by Linear Programming (선형계획법에 의한 하천유역의 최적수질관리)

  • 김상근;이순택
    • Water for future
    • /
    • v.16 no.3
    • /
    • pp.159-169
    • /
    • 1983
  • In this paper, a linear programming was used for determining the optimum efficiency required of each wastwater treatment facility and minimum total treatment casts in order to meet any set of stream dissolved oxygen standards within a river basin. The optimum solution of water quality control which was obtained with the inventory equation of Camp-Dobbins' equation incorporated into the constraints of linear programming was compared with that of Streeter-Phelps' equation. It can be concluded that correlation coefficient was 0.997. Then the linear programming incorporating the inventory equation of selected streeter-Phelps equation was used in order to obtain the optimum solution of water quality control based on data form the Nakdong River.

  • PDF

Data intercomparison and determination of toxic and trace elements in Algae using Instrumental Neutron Activation Analysis (중성자방사화분석에 의한 Algae중의 독성미량원소의 정량 및 실험실간 비교검증)

  • Chung, Yong-Sam;Moon, Jong-Hwa;Park, Kwang-Won;Lee, KiI-Yong;Yoon, Yoon-Yeol
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.346-353
    • /
    • 1999
  • For the non-destructive multi-elemental analysis of environmental and biological materials, instrumental neutron activation analysis (INAA) was applied for the determination of toxic and trace elements in a set of three Algae samples provided by the International Atomic Energy Agency (IAEA). The analytical quality control was evaluated by comparing the analytical results of two standard reference materials of the National Institute of Standards and Technology (NIST); Oyster Tissue (SRM 1566a) and Citrus Leaves (SRM 1572). According to given analytical procedure, the concentration of 15-25 elements including spiked elements such as As, Cd, Cr and Hg in Algae samples were determined. To identify and validate these results, a data intercomparison program using more than 35 analytical methods in 150 laboratories was carried out and the estimated statistical data are summarized. Result of INAA is favorable, therefore, it is illustrated that can be applied for routine analysis of essential and toxic elements in algae samples as well as analytical quality assurance.

  • PDF

Modern Paper Quality Control

  • Komppa, Olavi
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.5
    • /
    • pp.72-79
    • /
    • 2000
  • On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard. Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and cockling tendency, and provides the necessary information to fine-tune the manufacturing process for optimum quality. Many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, being beyond the measurement range of the traditional instruments or resulting inconveniently long measuring time per sample. The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, non-leaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layers of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow n well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. Hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly as planned (having even small measurement error or malfunction), the process control will set the machine to operate away from the optimum, resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

  • PDF

Influence of spent ginger yeast cultures on the production performance, egg quality, serum composition, and intestinal microbiota of laying hens

  • Liu, Junhan;Jin, Yuhong;Yang, Junhua
    • Animal Bioscience
    • /
    • v.35 no.8
    • /
    • pp.1205-1214
    • /
    • 2022
  • Objective: Spent ginger is a byproduct of juice extraction from the rhizome of ginger (Zingiber officinale). Despite its nutritional value, it is difficult to preserve or further process and thus is often wasted. This study uses spent ginger as a substrate for fermentation and cultivates spent ginger yeast cultures (SGYCs) that are then added to the feed of laying hens. The effects of SGYCs on production performance, egg quality, serum composition, and intestinal microbiota of laying hens were investigated. Methods: Eighty 60-week-old Hy-Line Brown hens were separated into 5 experimental groups with 4 replicates per group (4 hens per cage, 4 cages per replicate). The control group was fed a basal diet while experimental groups were also given SGYCs at the levels of 5, 10, 20, and 40 g/kg for 6 weeks. Results: The addition of SGYCs significantly increased the laying rate and nutrient digestibility, decreased feed conversion ratio, and enhanced the color of egg yolks (p<0.05). No changes were observed in activity levels of alanine aminotransferase and aspartate aminotransferase in the serum (p>0.05), but the activities of superoxide dismutase, glutathione peroxidase, and peroxidase all significantly increased, and contents of malondialdehyde were significantly reduced (p<0.05). In addition, changes in the relative abundance of Firmicutes and Bacteroidetes might be the main factor contributing to the significant increase in the apparent digestibility of crude protein and crude fat in laying hens (p<0.05). Conclusion: The current evidence shows that dietary supplementation of SGYCs to the feed of laying hens can improve laying rates, enhance antioxidative defenses, and influence dominant intestinal bacteria.

Experimental Study on the Proposal of an Assessment Method and Quality Standard for Identifying the Fine Particles of Clay Components in Fine Aggregates (잔골재의 토분 평가방법 및 품질기준 제안을 위한 실험적 연구)

  • Choi, Hyun-Kyu;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.585-596
    • /
    • 2022
  • The purpose of this study is to propose an assessment method to analyze clay collectively referred to as fine particles of clay components contained in fine aggregates, and to propose quality standards for clay use through correlation with the performance of concrete to verify the properties of clay measured according to the method. As a result, it is analyzed that it will be suitably utilized as a method to assess the fine particles of the clay component of fine aggregates through the component analysis of XRF. Regarding the related quality standards, considering the error rate of about 10% of KCS 14 20 10, the related quality standards were analyzed to be safe when Al2O3+Fe2O3+MgO is 23.5% or less and SiO2+K2OSiO2+K22O is 66.5% or more. To build on this study, it is expected that a comprehensive review will be conducted through additional follow-up studies such as on clay of coarse aggregates and durability analysis to establish a system for quality control of the soil fraction of aggregates.

Status and future perspective for soil contamination of arable land in China

  • Lee, Kyo Suk;Lee, Dong-Sung;Hong, Beong-Deuk;Seo, Il-Hwan;Lim, Chul-Soon;Jung, Hyun-Kyu;Chung, Doug Young
    • Korean Journal of Agricultural Science
    • /
    • v.46 no.4
    • /
    • pp.869-883
    • /
    • 2019
  • China is currently facing great challenges in protecting its arable soil from contamination by heavy metals, especially Cd in paddy soil. China enacted the first soil environmental quality standards (SEQS) for ten pollutants in 1995, and the Ministry of Ecology and Environment released the results of the first nationwide soil survey in 2014. The soil survey showed that as much as 16% of China's soil and 19% of the agricultural soils were contaminated mainly with heavy metals and metalloids beyond the environmental quality limits. The exceeded rate of the contaminant limits in food crops was widespread in China, and the most severe regions were East and Southwest China. Heavy metals and metalloids accounted for 82.4% of the contaminants in soils while organic pollutants accounted for 17% of the contaminants in the soil. Among the heavy metals and metalloids exceeding the Ministry of Environmental Protection (MEP) limit, cadmium (Cd) was highest at 7.0%, followed by nickel (4.8%), arsenic (2.7%), cobalt (2.1%), mercury (1.6%) and lead (1.5%). However, all the average concentrations of the pollutants were lower than the recommended values for the contaminants except for Cd for three levels of pH (< 6.5, 6.5 - 7.5, and > 7.5). According to the Action Plan on Prevention and Control of Soil Pollution released by the State Council in 2016, 90% of contaminated farmland will be made safe by 2020 with an increase to 95% by 2030. Therefore, it is necessary to improve the soil quality to meet the environmental quality standard for soils and heavy metal standards for food safety.

Randomized Controlled Clinical Trials in the Journal of Korean Society of Chuna Manual Medicine for Spine and Nerves: A Quantitative and Qualitative Analysis (척추신경추나의학회지에 수록된 무작위대조임상 연구의 양적, 질적 분석)

  • Cho, Hyun-Woo;Lee, Hyeon-Yeop;Heo, Kwang-Ho;Hwang, Eui-Hyoung;Shin, Mi-Suk;Shin, Byung-Cheul
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.7 no.2
    • /
    • pp.15-23
    • /
    • 2012
  • Objectives: The aim of this study is to assess the quantity and quality of randomized controlled clinical trials (RCTs) published in the journal of Korean Society of Chuna Manual Medicine for Spine and Nerves (KSCMSN). Methods: All relevant RCTs were selected and extracted. Data extract of RCTs from all the articles published in the jounal of KSCMSN up to now, quantity assessment was made on the study design, sample size, intervention, control group and medical condition. of the consolidated standards of reporting trials (CONSORT) check list. Assessment was performed by 2 independent reviewers and disagreement was discussed based on concensus. Results: Among the 276 articles, 10 RCTs were published. 1st articles were published in 2003 and half of RCTs were published in 2011. All RCTs were parallel 2-arm designed. Average sample size was 29.2 per study and 14.6 per arm. Main intervention was consisted as acupuncture 40%, pharmacopuncture 30% and Chuna 30%. Average of adequacy of CONSORT check list was 10.3% and overall reports were insufficient. Conclusions: Though RCTs published in jounal of KSCMSN were increasing, the quality remains low. KSCMSN should make a effort to follow the CONSORT statement and improve the quantity and quality of studies.

  • PDF

Air Quality Improvement Scenario for China during the 13th Five-Year Plan Period

  • Tang, Qian;Lei, Yu;Chen, Xiaojun;Xue, Wenbo
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.33-36
    • /
    • 2017
  • China is suffering from severe air pollution especially fine $PM_{2.5}$ pollution. In 2015, the annual average $PM_{2.5}$ concentration of the 338 municipal cities was $50{\mu}g/m^3$, 78% cities at or above the prefectural level failed to comply with the $PM_{2.5}$ concentration standards. The $13^{th}$ Five-Year Plan for National Economic and Social Development set the goal that the annual average concentration of $PM_{2.5}$ in the municipal cities which failed to attain the ambient air quality standards shall be decreased by 18% by 2020 (CCCPC, 2016). In this study, an air pollution control scenario during the $13^{th}$ Five-Year Plan period was proposed and the $SO_2$, $NO_x$ and PM emission reductions in response to different measures in 31 provincial-level regions mainland China by 2020 were estimated. The air quality in the target year (2020) was simulated using the WRF-CMAQ model. The results showed that by 2020, the emissions of $SO_2$, $NO_x$ and primary PM in mainland China will be reduced by 4.19 million tons, 3.94 million tons and 4.41 million tons, a drop of 23%, 21% and 25% respectively compared with that in 2015, and the annual average concentration of $PM_{2.5}$ will decrease by 19%. Coal-fired power plant contributes the most pollutant emission reduction.

A Basic Study on the Development of the Single-Phase Unified Poorer Quality Conditioner (단상용 통합형 전력품질 개선장치의 개발에 관한 기초연구)

  • 노대석;이현옥;오성철;최재석;차준민;김재언
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.2
    • /
    • pp.90-98
    • /
    • 2003
  • Recently, the increasing application of electronic equipments and information devices has heightened the interest in power qualify. The term power quality is applied to a wide range of electromagnetic phenomena on the power system and is also concentrated by all areas such as utilities, their customers and suppliers of load equipments. In engineering terms, power Qualify is expressed by voltage qualify because the power supply system can only control the quality of the voltage. Therefore, the standards in power quality area are devoted to keep the supply voltage within allowable limits. This paper deals with single-phase unified power quality conditioner (UPQC), which ai s at the integration of series-active and shunt-active filter. The series filter il used to compensate for the voltage distortions and the shunt filter is used to provide reactive power and counteract the harmonic current injected by the load. Also, the voltage of the DC link capacitor is controlled to a desired value by the shunt active filter. The validity of the proposed UPQC is demonstrated using both the MATLAB/SIMULINK simulation and the experimental device with DSP (TMS320C32).

Establishment of Quality Control System for Angiographic Unit (IVR장치의 성능 평가 기준 개발)

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.236-244
    • /
    • 2011
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure. The need for the quality control program of the angiographic units has also increased, because of concerns about the increased patient dose and the importance of image quality of angiographic units for the successful procedures. The purpose of this study was to propose an optimal guideline for the quality control program of the angiographic units. We reviewed domestic and international standards about medical imaging system and we evaluated the quality of 61 angiographic units in Korea with the use of NEMA 21 phantom. According to the results of our study, we propose a guideline for the quality control program of the angiographic units. Quality control program includes tube voltage test, tube current test, HVL test, image-field geometry test, spatial resolution test, low-contrast iodine detectability test, wire resolution test, phantom entrance dose test. Proposed reference levels are as follows: PAE < $\pm$ 10% in tube voltage test, PAE < $\pm$ 15% in tube current test, minimum 2.3 mmAl at 80 kVp in HVL test, minimum 'acceptable' level at image-field geometry test, 0.8 lp/mm for detector size of 34-40cm, 1.0 lp/mm for detector size of 28-33cm, 1.2 lp/mm for detector size of 22-27cm in spatial resolution test, minimum 200mg/cc in low contrast iodine detectability test, phantom entrance dose should be under 10R/min, 0.012 inch wire should be seen at static wire resolution test, and 0.022 inch wire should be seen at moving wire resolution test.