• Title/Summary/Keyword: Quality control materials

Search Result 1,128, Processing Time 0.024 seconds

Long Term Assessment of Quality of Life in Laryngectomee (후두전적출술 후 장기적인 삶의 질에 대한 평가)

  • Kwon Soon-Young;Yoo Hong-Kyun;Jung Kwang-Yoon;Choi Jung-Chul;Han Seung-Hoon;Choi Jong-Ouck
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.2
    • /
    • pp.191-195
    • /
    • 2000
  • Objectives: Despite various attempts to preserve the normal voice in advanced laryngeal cancer, it is inevitable for many advanced laryngeal cancer patients to undergo total laryngectomy and thus making a trade off between quality and quantity of life. Laryngectomees are faced with voice loss, change in physical appearance and health deterioration which hinder their efforts to rehabilitate back into their family and employment leading to poor quality of life. The objectives of this study were to evaluate the quality of life in long term surviving laryngectomees to, define the factors which are most important in determining their present quality of life and to propose a theoretical model for quality of life after laryngectomy in Korea. Materials and Methods: From 1986 to 1995, 120 laryngectomees with no evidence of disease were followed up for at least 3years were evaluated. Each of 15 quality of life domains with a total of ten points were given for a quality of life score. Results: There was no significant difference in the physical-mental adaptation index such as general health and mental health between the laryngectomees and control group(p>0.05). However, social adaptation index such as social activity, occupational status and economic status for laryngectomees were significantly lower with 2.3, 3.5, and 4.4 points compared to control group with 8.5, 7.6, and 7.1 points respectively(p<0.05). Conclusion : Vocational and social rehabilitation should be emphasized with highest priority for improving their economic status and thus improving their quality of life.

  • PDF

Improvement of the Stamping Formability by BHF Control (블랭크 홀딩력 제어에 의한 스탬핑 가공성 향상 기술)

  • 김영석;임성언;손형성;한수식
    • Transactions of Materials Processing
    • /
    • v.8 no.3
    • /
    • pp.269-275
    • /
    • 1999
  • A variable blank holding force method is proposed to improve deep drawing characteristics of sheet materials. In this method, the blank holding force (BHF) is controlled throughout a drawing process so that the punch load does not exceed a critical value, which is slightly less than the conventional process with the conforming process with the variable BHF is more flexible than the conventional process with the constant BHF and it could be used for improving the product's quality and drawability. In this paper we suggest a method controlling the BHF as a function of punch travel during the forming process. The optimization BHF curves are determined theoretically and experimentally. It is concluded that for the case of optimum BHF control methods the drawn cup height and the drawing formability achieved by this method are increased than those for constant BHF method. Also, as comparing the wall thickness distribution of the cup drawn by the constant BHF and the optimum BHF control, the BHF control reduce the wall thickness variation of the drawn cup at the cup wall and make the cup thickness distribution more uniformly than the constant BHF.

  • PDF

Development of Hot Rolling Process Analysis Simulator and Its Application(II) (열간압연 공정 해석용 시뮬레이터의 개발과 응용(II))

  • 이원호;이상룡
    • Transactions of Materials Processing
    • /
    • v.8 no.1
    • /
    • pp.78-91
    • /
    • 1999
  • The endless hot rolling has been focused as an innovative process technology for increasing the productivity drastically and reducing the imperfection of quality in hot rolled steel strip. To realize it in actual mill, a lots of new facilities such as bar coiler, movable LASER welder and high speed strip shear should be equipped. And also it is necessary to develop the control technique for changing the roll gap and rolling speed during rolling, which is named as Flying Gap and Speed Change control technology. To prevent a strip rupture caused by excessive tension, it is very important to minimize fluctuations in strip thickness and intension during FGSC control. In this paper, the mathematical model for FGSC control algorithm was suggested and dynamic simulation is performed to accertain the effect of suggested control method on fluctuations in strip thickness and tension. For endless hot rolling simulation, a lots of FGSC control situations, for instance - strip thickness change from strip to strip - strip width change from strip to strip - carbon content change from strip to strip are considered.

  • PDF

A Study on the Development of Communication Control System for Pressure Automatic System (사출 자동화 시스템을 위한 통신 제어 시스템 개발에 관한 연구)

  • 김현기;이천희
    • Journal of the Korea Society for Simulation
    • /
    • v.9 no.2
    • /
    • pp.39-49
    • /
    • 2000
  • In this paper, we added that developed communication control system between the PLC of pressure machine and the control computer, and developed a new protocol in order to communicate between the PLC signal of pressure machine and the control computer. This communication control systems play an important role in transforming the PLC vendor self-interface type and between computer and PLC. This system has PLC access function to control computer on the backbone network, and then could be operated by PLC through this system. The benefits we can obtain by developing this communication control systems are as follows; First, we can improve the quality of goods and the management of materials using the communication network and then implement the centralization management. Second, we can decrease manpower for production. Finally, we can maximize the company's profit with the increasing productivity by supervising the equipment wrong workings in the central.

  • PDF

Availability of Statistical Quality Control of Nuclear Medicine Blood Test Using Population Distribution (모집단 분포를 이용한 핵의학 혈액검사의 통계적 품질관리의 유용성)

  • Cheon, Jun Hong;Cho, Eun Bit;Yoo, Seon Hee;Kim, Nyeon Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.37-41
    • /
    • 2016
  • Purpose The importance of quality control by the error to a minimum, which for the purpose of enhancing the reliability of the examination is not be emphasized excess. Currently, most nuclear medicine laboratory are conducting the internal and external quality control, and they are applying the Levey-Jennings or Westgard Multi-Rules by using the commercialized quality control materials. The reliability of the nuclear medicine blood test which affects the diagnosis of patients and the treatment policy is being secured through this quality control activity. Therefore, researchers will evaluate the utility of the statistic quality control using the population distribution of the nuclear medicine blood test conducted targeting the checkup examinees by the additional technique of the reliability improvement. Materials and Methods A statistic analysis was performed about 12 items of the nuclear medicine blood test targeting 41,341 peoples who used the health screening and promotion center in Asan Medical Center from January, 2014 to December, 2014. The results of 12 items of the nuclear medicine blood test was divided into the monthly percentage of three groups: within reference values, over reference, and under reference to analyze the average value of the population distribution, standard deviation, and standard deviation index (SDI). Results The standard deviation of the population distribution mostly showed a result within ${\pm}2SD$ in all groups. However, When the standard deviation of the population distribution represented a result over ${\pm}2SD$, it was confirmed SDI was showing a result of SDI > -2 or SDI > 2. As a result of analyzing the population distribution of 12 items(AFP, CEA, CA19-9, CA125, PSA, TSH, FT4, Anti-Tg-Ab, Anti-TPO-Ab, Calcitonin, 25-OH-VitD3, Insulin) of the nuclear medicine blood part basic test, when SDI of the monthly percentage which deviated from the reference values was over ${\pm}2.0$, CA19-9 September was 2.2, Anti-Tg-Ab may was 2.2, Insulin January was 2.3, Insulin March was 2.4. It was confirmed these cases were attributed to the abnormality of the test reagent (maximum combination rate of isotope reagent declined) and the decline of the test response time. Conclusion The population distribution includes the entire attribute which becomes the study object. It is expected the statistic quality management using the population distribution which was conducted targeting the checkup examinees by dividing into three groups: within reference values, over reference, and under reference by means of this characteristics will be able to play a role of complementing the internal quality control program which is being carried out in the laboratory.

  • PDF

Quality evaluations of bell pepper in cold system combined with TEM (thermoelectric materials) and PCM (phase change material) (PCM을 장착한 열전소자 냉각시스템의 저장 중 피망의 품질 평가)

  • Sung, Jung-Min;Kim, So-Hee;Kim, Byeong-Sam;Kim, Jong-Hoon;Kim, Ji-Young;Kwon, Ki-Hyun
    • Food Science and Preservation
    • /
    • v.23 no.4
    • /
    • pp.471-478
    • /
    • 2016
  • For the distribution of fresh produce, the thermoelectric cooling system combined with thermo electric materials (TEM) and phase change material (PCM) was studied. The PCM used this study was produced by in-situ polymerization technology which referred microencapsulation of hydrocarbon (n-tetradecane and n-hexadecane). In this study, quality characteristics of bell peppers in thermoelectric cooling system combined with TEM and PCM were analyzed and control was placed in an EPS (expanded polystyrene) box. As a result of quality characteristics analysis, weight of bell peppers decreased and moisture content of bell peppers was 90.96~94.43% during storage. Vitamin C content of bell pepper decreased during storage and reduction ratio of control was higher than that of BPT-5 treatment(bell pepper in thermoelectric cooling system with PCM which is kept the temperature at $5^{\circ}C$). The result of color value, on 21 day, ${\Delta}E$ value of BPT-5 treatment was 5.05 while that of control was 41.8. On 21 day, total bacteria count of BPT-5 treated bell pepper shown less than that of control. In conclusion, it suggested that the thermoelectric cooling system combined with PCM improved quality of fresh produce during transportation and storage.

Development of Spray Coating Methods for Large Area Sol-Gel ZnO/Ag Nanowire Composite Transparent Conducting Substrates (대면적 졸-겔 산화아연/은 나노선 복합 투명 전도 기판 제조를 위한 스프레이 코팅법 개발)

  • Cho, Wonki;Baik, Seung Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.1
    • /
    • pp.55-60
    • /
    • 2018
  • Transparent conductive thin films (TCFs) are essential materials for solar cells, organic light-emitting diodes, and display panels. Indium tin oxide (ITO) is one of the most widely used commercial materials to create TCFs'; however, new materials that can possibly replace ITO at a lower cost and/or those possessing mechanical flexibility are urgently needed. Silver nanowire (AgNW) is one of those promising materials, as it is less expensive and possesses superior mechanical flexibility as compared to ITO. We used AgNW and sol-gel ZnO to fabricate composite thin films by spray coating. We propose two spray-coating methods: the 'metal-organic chemical vapor deposition (MOCVD)/AgNW' method and the Mixture method. These two methods are expected to be commercialized for high-quality and low-cost products, respectively.

REAL-TIME CORROSION CONTROL SYSTEM FOR CATHODIC PROTECTION OF BURIED PIPES FOR NUCLEAR POWER PLANT

  • Kim, Ki Tae;Kim, Hae Woong;Kim, Young Sik;Chang, Hyun Young;Lim, Bu Taek;Park, Heung Bae
    • Corrosion Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.12-18
    • /
    • 2015
  • Since the operation period of nuclear power plants has increased, the degradation of buried pipes gradually increases and recently it seems to be one of the emerging issues. Maintenance on buried pipes needs high quality of management system because outer surface of buried pipe contacts the various soils but inner surface reacts with various electrolytes of fluid. In the USA, USNRC and EPRI have tried to manage the degradation of buried pipes. However, there is little knowledge about the inspection procedure, test and manage program in the domestic nuclear power plants. This paper focuses on the development and build-up of real-time monitoring and control system of buried pipes. Pipes to be tested are tape-coated carbon steel pipe for primary component cooling water system, asphalt-coated cast iron pipe for fire protection system, and pre-stressed concrete cylinder pipe for sea water cooling system. A control system for cathodic protection was installed on each test pipe which has been monitored and controlled. For the calculation of protection range and optimization, computer simulation was performed using COMSOL Multiphysics (Altsoft co.).

Fabrication of Microlens Array by UV-molding (UV 성형을 통한 마이크로 렌즈 어레이의 제작)

  • 김석민;임지석;강신일;전병희
    • Transactions of Materials Processing
    • /
    • v.13 no.3
    • /
    • pp.236-241
    • /
    • 2004
  • UV-molded microlens arrays with high replication quality were fabricated using a parametric design method. It is important to maximize the replication quality, because one can obtain the replicated micro-optical components with desired properties by accurate control of the shape. In the present study, nickel mold inserts for microlens arrays with lenses having diameters between $3\mu\textrm{m}$ and $230\mu\textrm{m}$ were fabricated by electroforming process. An UV-molding system was designed and constructed, a simple technique to avoid micro-air bubbles was first suggested, and the effects of the compression pressure and UV-curing dose on the replication quality of UV-molded microlens arrays with a diameter of $14\mu\textrm{m}$ were examined experimentally. Finally, geometrical and optical properties of the replicated microlens arrays were measured and analyzed.

A Study on Optimization of Friction Welding of Automobile Component Materials(SM40C) and Its Real Time Quality Evaluation by AE (자동차 부품용 강재(SM40C)의 마찰용접 최적화와 AE에 의한 실시간 품질평가에 관한 연구)

  • Oh, Sae-Kyoo;Park, Jong-Bae;Kong, You-Sik
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.1 s.31
    • /
    • pp.88-93
    • /
    • 1999
  • This paper presents the experimental examinations and statistical quantitative analysis of the correlation between the cumulative counts of acoustic emission(AE) during plastic deformation periods of the welding and the tensile strength and other properties of the bar-to-bar welded joints of O.D. 16mm shaft(SM40C) as well as the various welding variables. And this is a new approach which attempts finally to develop real-time quality monitoring system for friction welding. The results lead to a practical possibility of real-time quality control more than 100% joint efficiency showing good weld with no micro structural defects.

  • PDF