• Title/Summary/Keyword: Quality control materials

Search Result 1,115, Processing Time 0.149 seconds

Quality monitoring of distributed materials from Glycyrrhizae Radix, Atractylodis Rhizoma Alba according to storage period (감초, 백출 유통품의 보관기간별 품질 모니터링)

  • Chun, Jin-Mi;Jang, Seol;Shim, Ji-Hoon;Lee, A-Yeong;Jeon, Won-Kyung;Lee, Hye-Won;Choo, Byung-Kil;Kim, Ho-Kyoung
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.3 s.18
    • /
    • pp.79-90
    • /
    • 2006
  • This study was investigated to determine the quality monitoring of distributed materials from Glycyrrhizae Radix (26 samples), Atractylodis Rhizoma Alba (24 samples) according to storage period after $1{\sim}3$ year. We have estimated by identification, purity, loss on drying, ash, acid insoluble ash, extract content, essential oil content, assay and microbial contamination. As a result, Glycyrrhizae Radix (26 samples) were satisfied with the standard of K.P. (Korean Pharmacopoeia) and WHO's microbial contamination limit standard. In the Atractylodis Rhizoma Alba (24 samples), 2 samples were not satisfied with the standard of K.P.(Korean Pharmacopoeia) and WHO's microbial contamination limit standard. The results make practical application of the basic data for the quality control of herbal medicine in storage.

  • PDF

Survey of Point-of-Care Testing Devices for Pre-hospital EMS Equipment of Glucometer on Local Area (지역 EMS의 현장검사 혈당측정기 사용에 대한 실태조사)

  • Byeong-Hyun, Kim;Dai-Hai, Choi;Gyoung-Yim, Ha
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.4
    • /
    • pp.220-228
    • /
    • 2022
  • Objective: glucometer is one of POCT(point-of-care testing) devices used by EMS. Accurate measurement value is important for patient decision making. Quality control is necessary for this, but most EMS are still using glucometer without quality control it. Therefore, management status and quality control status of glucometers used by 119 paramedics waswere investigated. Methods: 6 and 8 of glucometers and blood glucose test strips were submitted from 4 safety centers in 2010 and 8 safety centers in 2012, respectively. Glucometers submitted by local safety centers were analyzed in 2010 and 2012. The control glucometer, which was well managed at A University Hospital, was assumed to be accurate for at blood glucose measurement. Glucose values of various quality control materials control solutions were measured and analyzed using linear regression and Pearson's correlation test. Error rates were obtained via error tolerance range required by the 2011 ISO(International Organization for Standardization) guideline. For statistics, Excel and MedCalC programs were used. Results: mong 14 safety centers in the region, 4 centers(28.5%) in 2010 and 8 centers(57.1%) in 2012 submitted 6 and 8 glucometers. In the first evaluation in 2010, 2 out of 6(33.3%) glucometers were untestable due to error, and 45 out of 6(66.683.3%) blood glucose test strips' validity were expired. In the second evaluation in 2012, 1 out of 8(13.5%) glucometers were untestable due to lack of battery, and 2 out of 8(25%) blood glucose test strips' validity were expired. All correlation coefficients were above 0.989 in 2010 and above 0.997 in 2012. Error rates were generally high when using expired blood glucose test strips. Conclusion: Among 119 paramedics' guideline, quantity and operation status of POCT devices are well managed, but quality control is not. Therefore, it is necessary to add management status and quality control status of POCT devices to the EMS' field work guideline.

Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT (PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가)

  • Choong-Woon Lee;Yeon-Wook You;Jong-Woon Mun;Yun-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF

Addition of Novel Lactobacillus plantarum KCC-10 and KCC-19 to Improve Fermentation Quality and Characterization of Italian Ryegrass Silage

  • Srigopalram, Srisesharam;Ilavenil, Soundharrajan;Vijayakumar, Mayakrishnan;Park, Hyung Soo;Lee, Kyung Dong;Choi, Ki Choon
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.35 no.3
    • /
    • pp.195-200
    • /
    • 2015
  • An investigation was carried out to evaluate the potential role of Lactobacillus Plantarum KCC-10 and KCC-19 on the quality and fermentation characterization of Italian ryegrass (IRG) silages. The physiochemical properties of IRG silage such as crude protein content, neutral detergent fiber, acid detergent fiber, total digestible nutrient and in vitro dry matter digestibility were not affected by KCC-10 and KCC-19. The pH of IRG silage in KCC-10 and KCC-19 treatments decreased compared to the control (p<0.05), while the lactic acid content in KCC-10 and KCC-19 treatments increased compared to the control (p<0.05). In addition, the number of lactic acid bacteria (LAB) in the KCC-10 treatment increased compared to the control (p<0.05). The number of lactic acid bacteria in KCC-19 increased, but there was no significant difference in all treatments. Therefore, we recommend L. plantarum KCC-10 and KCC-19 as potential additive candidates in IRG silage with lots of advantages.

Influence of green-house type and covering materials on growth and cut flower quality of Antirrhinum majus and Mathiola incana (금어초와 스토크의 생장과 품질에 미치는 하우스의 형태 및 피복재료의 영향)

  • 정순경;김원희;박중춘
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1993.05a
    • /
    • pp.9-10
    • /
    • 1993
  • 최근 농가에서 시설되는 하우스의 형태와 피복재료가 다양해지고 있으나 작물재배를 통한 검사는 미진한 실정이다. 본 연구는 91년도에 채소와 화훼 공동으로 농가보급형 하우스 모델을 설계하고 시설된 하우스에서 PET와 EVA간의 차이와 하우스형태간의 차가 절화로 이용되는 금어초와 스토크의 생육과 품질에 미치는 영향을 구명할 목적으로 수행하였다. (중략)

  • PDF

Intelligent Resistance Spot Welding System and its Automotive Body Application (지능형 저항 점 용접 시스템의 자동차 차체 적용)

  • Jo, Yong-Jun;Yu, Seong-Pil;Jang, In-Seong;Lee, Hui-Beom
    • Proceedings of the KWS Conference
    • /
    • 2006.10a
    • /
    • pp.77-79
    • /
    • 2006
  • While RSW(Resistance Spot Welding) have been the most successful sheet metal joining process in automotive industry, there are certain qualify issues due to the control system and its application process. Recent materials and coatings make the process more complicated resulting in new challenges for quality welds. In this research, an intelligent RSW system with adaptive control algorithm is introduced to overcome typical RSW issues and its applications to automotive body assembly are presented.

  • PDF

Development of an Intelligent Operation Support System (지능적 조업 지원 시스템의 개발)

  • 이영학;이동희;한종훈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.391-391
    • /
    • 2000
  • Manufacturing process generally exhibits major or minor variations due to deviation of raw materials, equipment degradation, controller malfunction, and so on. Extensive research based on multivariate statistical process control has been done to monitor the unstable states and indicate a corrective action. A prototype of intelligent operation support system ("ISYS-MSPC") has been developed as a tool that supports the enhanced operation to guarantee the high productivity and a uniform high quality product. This system has been applied to the industrial batch and continuous processes and its performance has been validated .

  • PDF

Effect of Black Charcoal and Activated Carbon for Reduction of Radon Radioactivity that Emitted from Building Materials (건축재료로부터 방출되는 라돈방사능 감소를 위한 흑탄과 활성탄 효과)

  • Cho, Yun-Min;Lee, Hwa-Hyung
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.1
    • /
    • pp.13-17
    • /
    • 2011
  • Recently, interest in indoor air quality is increasing. Especially, radon radioactivity among the indoor air is a well-known risk factor for lung cancer because of ionizing radiation in the form of ${\alpha}$-particles. This study was carried out to investigate effect of black charcoal and activated carbon for reduction of radon radiation that emitted from building materials. Black charcoal and activated carbon were used as a barrier which was against the infiltration of radon. The source of radon was gypsum board. Two types of charcoal barrier were powder- and board-type with 5 mm, 10 mm thickness respectively. The method for this determination is evaluated radon concentration in chamber. The measurements were performed with radon detector, SARAD3120. Results of this study are as following: Black charcoal and activated carbon confirmed the highly efficient barrier. Radon concentration was reduced from 72% to 85% as compared the control chamber. Radon reduction capability, however, was no difference as barrier's types. Results obtained in ventilation condition, radon concentration shows 5.93 pCi/L on average in the closed condition and shows 2.69 pCi/L in the opened condition.

  • PDF

한약재 품질관리의 개선방향

  • Park, Jin-Han
    • 대한한약학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.129-144
    • /
    • 2007
  • In order for stable demand-supply and regularity of distribution, "The regulations for management of demand-supply and distribution of medicinal herbs" were established on 1995. Therefore, the medicinal herbs of good quality have been controled to be distributed in the market. However, to be wide of the purpose, the standardized sound distribution system was caused due to the governmental control on demand-supply to protect domestic farmers who produce the material for medicinal herbs, which results in the over distribution of non-standardized or illegally imported medicinal herbs. In addition, because of the distribution of faulty or poor medicinal herbs, there are chances of affecting bad effects on public health. The standardized medicinal herbs cover 514 different kinds in total, of which 69 products are specified to be standardized in the oriental medicine product companies. Also, in order to protect farmers who produce the materials for medicinal herbs, the amount of imported materials are regulated in normal times. The 14 different materials for medicinal herbs, which are allowed to be imported to a certain amount only when the shortage of goods or sudden rise of prices is to happen, are frequently introduced into domestic market as food not as medical usage, and the origin of those illegally changes to home cropped one for the distribution in the market. In addition, the system of distribution are to be disordered and the condition for the distribution of medicinal herbs of good quality can not be made since they illegally changes the usage of the materials for medicinal herbs from their original one and can not be regulated by the domestic laws.

  • PDF

A Study on Trend of Tensile Properties with Ratio of Water Mixture under Low and High Temperature Environment in Hydroponic Polyurethane Waterproofing Materials (수경화성 폴리우레탄 도막재의 물 혼합비에 따른 저온 및 고온 환경에서의 인장성능 변화 추이 연구)

  • Kim, Dong-Bum;An, Hyun-Ho;Kim, Sun-Do;Park, Wan-Goo;Park, Jin Sang;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.211-212
    • /
    • 2016
  • Due to a lack of objective and adequate study on the physical effects on hydroponic polyurethane waterproofing material water mixture ratio, construction site workers are having to rely on their hands-on experience to determine a mixture ratio, resulting in difficulty of maintaining quality management. Particularly in cases of rooftop exposed type hydroponic polyurethane materials, the varying temperature conditions make it further difficult for quality management control. in this regard, this study conducts tensile strength testing and compares the tensility change rates hydroponic polyurethane waterproofing materials with various water mixture ratios ranging from 0%~50% and exposed to alternating temperature change between -20℃ to 60℃ in the span of 1 hour after curing for 14 days.

  • PDF