• Title/Summary/Keyword: Quality Test

Search Result 11,137, Processing Time 0.043 seconds

Cortical Thickness Estimation Using DIR Imaging with GRAPPA Factor 2 (DIR 영상을 이용한 피질두께 측정: GRAPPA 인자 2를 이용한 비교)

  • Choi, Na-Rae;Nam, Yoon-Ho;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.56-63
    • /
    • 2010
  • Purpose : DIR image is relatively free from susceptibility artifacts therefore, DIR image can make it possible to reliably measure cortical thickness/volume. One drawback of the DIR acquisition is the long scan time to acquire the fully sampled 3D data set. To solve this problem, we applied a parallel imaging method (GRAPPA) and verify the reliability of using the volumetric study. Materials and methods : Six healthy volunteers (3 males and 3 females; age $25.33{\pm}2.25$ years) underwent MRI using the 3D DIR sequence at a 3.0T Siemens Tim Trio MRI scanner. GRAPPA simulation was performed from the fully sampled data set for reduction factor 2. Data reconstruction was performed using MATLAB R2009b. Freesurfer v.4.3.0 was used to evaluate the cortical thickness of the entire brain, and to extract white matter information from the DIR image, Analyze 9.0 was used. The global cortical thickness estimated from the reconstructed image was compared with reference image by using a T-test in SPSS. Results : Although reduced SNR and blurring are observed from the reconstructed image, in terms of segmentation the effect was not so significant. The volumetric result was validated that there were no significant differences in many cortical regions. Conclusion : This study was performed with DIR image for a volumetric MRI study. To solve the long scan time of 3D DIR imaging, we applied GRAPPA algorithm. According to the results, fast imaging can be done with reduction factor 2 with little loss of image quality at 3.0T.

An Example of Test on Differences of Pulse Waveform Characteristics at Cun, Guan and Chi (촌, 관, 척 위치의 맥파 특징 차이 검정에 대한 1례)

  • Lee, Jeon;Lee, Yu-Jung;Jeon, Young-Ju;Lee, Hae-Jung;Ryu, Hyun-Hee;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.2
    • /
    • pp.107-112
    • /
    • 2008
  • Although the pulse diagnosis position, Guan is apart from Cun or Chi by only $10{\sim}20$ mm at most, traditional medical doctors applies different indent pressures and even they states different pulse images are felt at Cun, Guan and Chi, To support their clinical behaviors, in this study, we tested statistically whether there are differences in pulse waveform measured at these three positions with SphygmoCor system used world widely, A 30 years old female subject without any evidence of cardiovascular diseases was involved in this experiment. Radial pulse waves were recorded at three different positions on left lower arm 10 times at three positions-Cun, Guan and Chi. With ANOVA, we tested whether, among three different positions. there are any differences in 12 parameters of radial pulse waveform and in estimated AIx(Augmentation Index) as an arterial stiffness index extracted from radial pulse waveform. As results, differences in optimal indent pressure h0 were observed at different measuring positions(P<0.001) but not significantly different. And pulse pressure his were found to be different(Chi$22.60{\pm}3.06%,\;18.60{\pm}3.37%\;and\;26.4{\pm}5.02%$ respectively. Consequently. AIx at Gwan seems to be lowest and that at Chi seems to be highest. So. we assert the AIx at Chi is likely to be overestimated. In further studies. we want to examine what make differences in these parameters between measuring positions. And it also seems to be worthy to investigate the relationship between the depth of radial artery and AIx. And, ultimately, we need to determine the best measuring process including measuring position, hold-down pressure, signal quality validation and so on. so to achieve the optimal waveform which represents subject's health condition for both western medicine and traditional medicine.

  • PDF

A Study on TDMG Pulse Performance and Structure for Performance Improvement of UWB system (UWB 시스템의 성능개선을 위한 TDMG 펄스 발생기의 성능과 구조에 관한 연구)

  • Ko, Young-Eun;Bang, Sung-Il
    • The KIPS Transactions:PartC
    • /
    • v.11C no.3
    • /
    • pp.395-400
    • /
    • 2004
  • Being aware of growing needs for wireless communication led to the development of UWB systems, this study proposed an impulse for single band UWB systems which does not count a carrier; analyzed the characteristics and the problems of pulses suggested by the existing poise of the Un system; finally, proposed TDMG(Time Delay Multiple Gaussian) pulse that generates signals of UWB without attenuation of pulse width. The hardware structure of the TDMC pulse for the single band UWB system was modelled after describing the pulse in a mathematical method in an attempt to compare with performances of the existing pulses through computer simulation. The outcome of the test unveiled the fact that each center frequency of the TDMG pulse rose approximately 1GHz, and also each l0dB fractional bandwidth of the TDMG pulse was widened over 1GHz. In the case of derivative, center frequencies of the TDMG pulse rose over 1GHz each. As a consequence, the TDMG pulse appeared to have better quality frequency, satisfying the characteristics of spectrum and the band of frequency recommended by the FCC and decreasing interference with other wireless communication systems.

UPnP-based QoSAgent for QoS-guaranteed Streaming Service in Home Networks (서비스 품질이 보장되는 홈 네트워크 스트리밍 전송을 위한 UPnP 기반의 QoSAgent에 대한 연구)

  • Lee Hyun-Ryong;Moon Sung-Tae;Kim Jong-Won;Shin Dong-Yun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.5B
    • /
    • pp.430-441
    • /
    • 2006
  • As the various A/V devices and home networks are delivered to users, home networks are changing to an entertainment network. It is expected that the required network bandwidth and the amount of usage of media content in home entertainment networks will be increased. Although the access networks and home networks becoming a high speed network, there remains the problems for QoS-guaranteed media content transfer in home networks. Also, in the home network, there can be network traffic caused by applications like video conferencing, video telephone, and VoIP(voice over IP) as well as inner network traffic of home network. Since media content transfer requires the real-time delivery, it is very important and basic requirement that is to transfer media content to A/V device user wants while keeping the media quality. Even though there are many middleware protocol for home networking, they provide basic device discovery and control or simple functions for QoS-guaranteed media content transfer that are not enough to provide QoS-guaranteed media transfer service that user wants. Thus, in this paper, we propose the technique based on UPnP(universal plug and play) protocol for QoS-guaranteed media content transfer in the home network. The proposed technique is compatible with UPnP and can be used with UPnP as additional functions. In this paper, we utilize VideoLAN application to verify the proposed technique. We add the additional modules that support the proposed technique's function to VideoLAN and we verify the its functions through various test scenarios.

Properties of Hydration Heat of High-Strength Concrete and Reduction Strategy for Heat Production (고강도 콘크리트의 수화열 특성 및 발열 저감대책에 관한 연구)

  • Jaung, Jae-Dong;Cho, Hyun-Dae;Park, Seung-Wan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.2
    • /
    • pp.203-210
    • /
    • 2012
  • Recently, the interest and demand for large-scale buildings and skyscrapers have been on the rise, and the performance of concrete is an area of high priority. Securing 'mass concrete and high strength concrete' is very important as a key construction technology. For high strength concrete, the high heat of hydration takes place inside the concrete because of the vitality of hydration in cement due to the large amount of powder, and leads to problems such as an increase of thermal stress due to the temperature difference with the outside, which results in cracks and slump loss. For this reason, measures to solve these problems are needed. This study aims to reduce the hydration heat of high strength concrete to control the hydration heat of mass concrete and high strength concrete, by replacing the type of admixture, The purpose of this study is to control the hydration heat of high strength concrete and mass concrete. Our idea for this purpose is to apply not only the types and contents of admixture but also incorporation mixing water to ice-flake. As a result of the test, the use of blast furnace slag and fly ash as admixture, and the use of ice-flake as mixing water can improve the liquidity of concrete and reduce slump loss. Significantly dropping the maximum temperature will contribute greatly to reducing cracks due to hydration heat in mass concrete and high strength concrete, and improve quality.

A Space Skew and Crosstalk Cancellation Scheme Based on Indoor Spacial Information Using Self-Generating Sounds (자체발성음을 이용한 실내공간정보 획득 및 공간뒤틀림/상호간섭 제거기법)

  • Kim, Yeong-Moon;Yoo, Seung-Soo;Lee, Ki-Seung;Kim, Sun-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2C
    • /
    • pp.246-253
    • /
    • 2010
  • In this paper, a method of removing the space skew and cross-talk cancellation is proposed where the self-generated signals from the subject are used to obtain the subject's location. In the proposed method, the good spatial sound image is maintained even when the listener moves from the sweet spot. Two major parts of the proposed method are as follows: listener position tracking using the stimuli from the subject and removal of the space skew and cross-talk signals. Listener position tracking is achieved by estimation of the time difference of arrival (TDoA). The position of the listener is then computed using the Talyer-series estimation method. The head-related transfer functions (HRTF) are used to remove the space skew and cross-talk signals, where the direction of the HRTF is given by the one estimated from the listener position tracking. The performance evaluation is carried out on the signals from the 100 subjects that are composed of the 50 female and 50 male subjects. The positioning accuracy is achieved by 70%~90%, under the condition that the mean squared positioning error is less than $0.07m^2$. The subjective listening test is also conducted where the 27 out of the 30 subjects are participated. According to the results, 70% of the subjects indicates that the overall quality of the reproduced sound from the proposed method are improved, regardless of the subject's position.

The Effect of Participation Motivation and Satisfaction on the Participation Persistence among Adult Learners at College Continuing Cducation Center (전문대학 평생교육 학습자의 평생교육프로그램 참여 동기와 만족도가 참여 지속의도에 미치는 효과)

  • Yoo, Mi-soo;Kwak, Keun-Hey;Park, Sun-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.414-422
    • /
    • 2017
  • This study was conducted to analyze the effects of motivation and satisfaction with continuing education on the intention to participate in college continuing education programs among adult learners. and participation of continuing education to improve the quality of Continuing education programs operated by College and to develop diverse educational programs that reflect the needs of adult learners and increase their participation rate. This study analyzed data collected from 412 adult males and females taking courses at the Lifelong Education Center in four professional universities in Gyeonggi-do from May 1 to June 20, 2017. Data analysis was performed using SPSS Version 21.0 program, and general characteristics of the subjects were used. Descriptive statistics, t-tests and ANOVA were used to identify differences in participants' motivation, satisfaction with education, and intention to participate. Participants' motivation, satisfaction with education, and intention to participate were analyzed by Pearson's correlation. Participants were analyzed by stepwise multiple regression analysis. There was a significant positive correlation between motivation for participation in college continuing education programs, intention to participate in education programs, and intention to participate. The factors influencing participants' motivation for participation were participation motivation and education satisfaction 41.2%.The results of this study suggest that it is necessary to develop and operate a program considering the factors that can improve motivation for participation and educational satisfaction to increase learner motivation.

The Studies on the Removal of Harmful Microorganisms in Water by Using Antimicrobial Copper (친환경 항균성 구리의 수질 내 생물학적 오염원 제거 가능성 연구)

  • Ji, Keunho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.384-390
    • /
    • 2018
  • Air and soil are being contaminated by the environmental pollution as a result of climate change and urbanization, resulting in water pollution reaching serious levels. In this studies, we investigated the use of antimicrobial copper for the removal of biological pollutants from water system. Specifically, we tested its effects against E. coli, B. subtilis, S. aureus, K. pneumoniae and P. aeruginosa. Made a sphere shape having a diameter of 2cm using a strip-shaped copper wire of 0.5g, 1g and 2g. And then, to confirm the antimicrobial activities, each copper ball was equipped in the broth which inoculated each pathogens. The results showed that bacterial growth of the five test bacteria was inhibited by more than 99% after reaction with a 0.5 g copper ball for at least 20 minutes. Based on the these results, if perform the further experiment such cytotoxicity, it is expected that will be enough to be used as a filter for water quality purification. The developed technique is expected to be widely applied in various industries.

The Use of Styrofoam Box for Chikso (Korean Brindled Cattle) Semen Cryopreservation with Liquid Nitrogen (칡소 동결 정액 생산을 위한 스티로폼상자와 액체질소 이용 방법)

  • Kim, Sung Woo;Ko, Yeoung-Gyu;Lee, Jae-Yeong;Kim, Chan-Lan;Hwang, In-Sul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.490-496
    • /
    • 2020
  • A styrofoam box is used as a simple and easy freezing method to preserve animal semen as a livestock genetic source. This study optimized the methods of freezing chikso brindled cattle semen. To test the freezing box, the motility of spermatozoa was compared between two box sizes (length×width×heigh) with the dimensions of 23.5×30.5×22.5 cm and 25.5×46.5×26.5 cm. The motility of thawed sperm from brindled Korean bulls was used to confirm the efficiency of the freezing boxes. The box having a larger inner space with larger horizontal and height measurements supported better motility after thawing (60.4±5.3% vs 67.2±3.1%) with 10 min of exposure time in liquid nitrogen vapor. The optimized freezing space is estimated to be an essential element for successful freezing results and the larger box could be used for production of more than 60 frozen semen straws. These properties are also helpful to optimize the cryopreservation techniques that would control the quality and quantity of semen straws according to different animal species.

EVALUATION OF MICROLEAKAGE WITH RETROGRADE FILLING MATERIALS IN BLOOD CONTAMINATION USING FLUID TRANSPORT MODEL (Fluid transport model을 이용한 치근단 역충전 재료의 혈액오염시 미세누출평가)

  • Ahn, Hyo-Soon;Jang, In-Ho;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Leakage studies have been performed frequently, since a fluid-tight seal provided by various dental fill-ing materials has been considered clinically important. The leakage of the various root-end filling materials has been widely investigated mostly dye penetration method. These dye studies cannot offer any information about the quality of the seal of a test material over a long period of time The purpose of this study was to evaluate the microleakage of root end cavities in blood contamination filed amalgam, intermediate restorative material(IRM), light cured glass ionomer cement(GI) and mineral trioxide aggregate(MTA) by means of a modified fluid transport model. Fifty standard human root sections, each 5mm high and with a central pulp lumen of 3mm in diameter, were and filled with our commonly used or potential root end fill ing materials after they were contaminated with blood. At 24h. 72h, 1, 2, 4, 8, and 12 weeks after filling, leakage along these filling materials was determined under a low pressure of 10KPa(0.1atm) using a fluid transport model. The results were as follows : 1 MTA group showed a tendency of decreasing percent of gross leakage (20m1/day) in process of time, whereas the other materials showed a tendency of increasing in the process time. 2. At the all time interval, GI group leaked significantly less than amalgam group and IRM group (p<0.05). 3. At the 4 weeks, the percentage of gross leakage in MTA group decreased to 0% thereafter, the low per-centage of gross leakage was maintained in MTA group until the end of the experiment, whereas the percentage in IRM group increased to 100% 4. At the 12 weeks, percentage of gross leakage was significantly low in MTA group(0%), comparison with GI group(40%), amalgam group(90%) and IRM group(100%), but there was no significant difference between latter two materials.