• 제목/요약/키워드: Quality Measurement Method

검색결과 1,468건 처리시간 0.032초

중소제조업체의 측정기 운영에 관한 실증적 연구 (A Study on Management for Measuring Instrument of Small and Medium-sized Enterprises)

  • 유재권;유현종
    • 산업융합연구
    • /
    • 제6권2호
    • /
    • pp.43-56
    • /
    • 2008
  • Measurement is used for evaluation of product or process exactly. If it couldn't measured correctly, Quality-cost must be raised and it would be hard to improve product quality. So, this study suggests improvement guide line for the multilateral problems of measuring instrument operation based on the investigation of 157 small and medium-sized enterprises in February, 2008. To use measuring instrument correctly, man who treat it must be accustomed with the structure, the performance, the method. The instrument is selected properly for the measurement goal. If not, results couldn't be correctly or wasted time, efforts, and costs. When selecting a instrument, the tolerance, the size, the figure, the material, and the efficiency must be considered. If the measuring instruments are controlled efficiently, it could be accomplished that improving product quality and coinciding with the goal of QM.

  • PDF

HSDPA 환경에서의 u-Healthcare 서비스를 위한 무선 데이터 품질 측정 방안 연구 (A Study on Wireless Data Quality Measurement Method for u-Healthcare Service in HSDPA Environment)

  • 윤성열;박석천
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권6호
    • /
    • pp.127-134
    • /
    • 2011
  • 최근 각광받고 있는 무선 데이터 통신 인프라는 유선에서의 한계점을 넘어 빠른 속도로 발전 하고 있다. 특히, 이를 이용한 u-Healthcare 서비스에 대한 이슈가 증가하고 있으며, 원활한 서비스 제공을 위해서는 무선 데이터망의 품질 보장에 대한 연구가 중요하다. 그러나 기존 연구는 유선망에 대한 종단간 품질관리만을 집중 수행하고 있기 때문에 무선망에 대한 품질관리 연구가 미비하다. 본 논문은 이에 대한 연구로 u-Healthcare 서비스를 제공받는 무선 데이터 망 사용자의 품질 보장 및 사용자 요구를 만족시키기 위한 방안인 무선 환경을 고려한 무선서비스 품질측정 기준을 제시하였다. 이를 위해 무선데이터 품질 측정 지표 및 기준을 선정하였고, 품질 측정 평가 방안을 서비스별로 제시하였으며, 각각의 서비스 별로 품질지표를 제시하였다.

네트워크 보안 효율성 제고를 위한 보안 QoS(Quality of Service) 측정방법론 연구 (A Study of Security QoS(Quality of Service) Measurement Methodology for Network Security Efficiency)

  • 노시춘
    • 융합보안논문지
    • /
    • 제11권1호
    • /
    • pp.39-48
    • /
    • 2011
  • QoS(Quality of Service)는 ITU-T Rec. E.800에 의해 서비스를 사용하는 형태, 특성 그리고 요구 수준에 따라 사용자의 요구에 부응하여 제공할 수 있는 네트워크 서비스의 성능지표로 표현된다. 네트워크를 활용하는 정보시스템에서 최종적인 목표는 요구되는 시간내에 목적하는 성능을 확보하는 것이다. 본 연구에서 제안하는 보안 QoS 프레임워크는 측정 메트릭스, 측정스케쥴, 측정도구, 측정의순서, 측정 결과분석에 관련된 사항으로 구성된다. 보안 QoS에서 네트워크보안의 정보보호기능과 시스템기능을 분리하여 관리하지 않고 연계하여 종합 메커니즘으로 구성 및 적용할 경우 종합적인 정보보호 효율은 시너지효과로 나타난다. 본 연구는 정보보호기능과 제반 시스템기능을 연계하여 정보보호기능을 적용했을 경우의 연동메커니즘 구현방법 개발과 그 성과를 측정하기 위한 것이다. 본 연구에서 제안한 네트워크 보안 효율성 제고를 위한 보안 QoS측정방안 연구 방법론을 통해 체계적인 측정환경을 설계할 경우 운용시스템상에서 보안 효율성 측정이 가능함이 입증되었고 측정 메커니즘을 통해서 개선된 네트워킹기능과 정보시스템 기능을 위한 효율성제고 방법론 개발이 가능함을 보여주고 있다.

5-cycle 모드 특성에 따른 온실가스 배출특성 및 배출량 보정식 개발 연구 (A Study on the Developments of Emission Correction Formula and Emission Characteristics of Greenhouse Gas by 5-Cycle Mode)

  • 박진성;임재혁;이민호;김기호
    • 동력기계공학회지
    • /
    • 제21권6호
    • /
    • pp.94-100
    • /
    • 2017
  • Due to the environmental problems caused by the greenhouse effect, regulation of $CO_2$ emissions is getting stronger day by day. In paricular, regulations of automobiles $CO_2$ emissions are being strengthen. However, existing $CO_2$ measurement methods do not reflect the environment and operating conditions on actual roads. Emissions of $CO_2$ can be increased by various conditions such as environmental condition(temperature and humidity) and driver's tendency(aggressive and passive). Therefore it is necessary to reflect the conditions of various actual roads such as 5-cycle test method on behalf of the existing $CO_2$ emission measurement method. The 5-cycle measurement method has five test modes; FTP-75, HWFET, US06, SC03, Cold FTP-75. The method reflects the following three environments and operating conditions as compared to conventional method; Using heater at low temperature, Aggressive driving such as rapid acceleration or deceleration, Using air conditioner at high temperature. Because of these various conditions of each test cycle, the 5-cycle method can reflect actual environments and operating conditions. This paper attempt to analyze $CO_2$ emission characteristics based on the results measured through the 5-cycle mode and develop the correction formula that can derive the results of the 5-cycle test method using existing test methods. As a result, the developed correction formula is expected to reduce $CO_2$ emissions and cut down expense for testing 5-cycle mode.

소프트웨어 오류 데이터를 기반으로 한 소프트웨어 신뢰성 성장 모델 제안 (The Software Reliability Growth Model base on Software Error Data)

  • 정혜정;한군희
    • 한국융합학회논문지
    • /
    • 제10권3호
    • /
    • pp.59-65
    • /
    • 2019
  • 본 연구에서는 기존에 소프트웨어 품질 평가를 위해서 사용되었던 ISO/IEC 9126-2와의 차이점을 비교하기 위해서 소프트웨어 품질 평가를 위해서 새롭게 제시된 ISO/IEC 25023의 소프트웨어 품질 측정 메트릭을 제시하고 제시된 메트릭에 대해서 품질을 측정하는 방안을 제시한다. ISO/IEC 25023에 제시된 8가지 품질 특성 중에서 신뢰성에 대한 품질 측정 방안을 소프트웨어 신뢰성 성장 모델을 기반으로 평가하는 방안을 제시한다. ISO/IEC 25023을 기반으로 소프트웨어 품질을 평가하게 되어지면 신뢰성에 대한 평가에 있어 다소 리스크가 있을 수 있음을 데이터를 기반으로 하여 입증한다.

영상처리를 이용한 향균성 시험방법 신뢰성 개선 (Enhancing Reliability of Antibacterial Test Methods using Image Processing)

  • 엄원용;박재우;김지훈;강진우
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.597-602
    • /
    • 2017
  • 본 논문에서는 군에서 사용하는 텍스타일 재료에 대한 항균성 시험방법의 신뢰성 확보 방안을 제시하고자 하였다. 항균성은 일반적으로 세균의 증식을 억제하고 유해한 균을 제거하는 것을 말하며, 항균성을 측정하는 시험방법은 텍스타일 재료의 특성과 형태에 따라 다양한 방법이 있다. 항균성 시험방법인 KS K 0693 '텍스타일 재료의 향균성 시험방법'에 따르면, 콜로니 수를 측정할 때 시험자가 육안으로 세어 측정한다. 이때 시험자의 숙달수준에 따른 측정오차가 발생할 가능성이 크며 자동화되지 않아 비교적 시간이 오래 걸린다. 이러한 단점을 개선하기 위해 영상처리 기술을 적용하여 향균도를 측정하는 방법을 제안한다. 시험자료는 '방탄헬멧 부유대조립체 완충패드'의 외피소재를 대상으로 하고, 공인시험기관에서 발급된 시험 성적서에 첨부된 배양배지 영상을 사용하였다. 배양배지 영상을 전처리 한 후 분할 및 이진화 처리 후 영상 내 입자의 수를 세어 콜로니수를 확인하는 방법을 제안한다. 제안하는 방법을 적용한 항균도 측정결과와 기존 시험방법의 측정결과를 비교한 결과, 제안하는 방법은 기존의 시험방법을 통한 항균성 측정결과 대비 0.9%p 정도의 차이를 보였다. 제안하는 방법은 측정자의 오차를 제거하여 신뢰성을 확보할 수 있으며 측정 시간이 짧다는 장점이 있다.

Uncertainty Assessment: Relative versus Absolute Point Dose Measurement for Patient Specific Quality Assurance in EBRT

  • Mahmood, Talat;Ibrahim, Mounir;Aqeel, Muhammad
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.111-121
    • /
    • 2017
  • Verification of dose distribution is an essential part of ensuring the treatment planning system's (TPS) calculated dose will achieve the desired outcome in radiation therapy. Each measurement have uncertainty associated with it. It is desirable to reduce the measurement uncertainty. A best approach is to reduce the uncertainty associated with each step of the process to keep the total uncertainty under acceptable limits. Point dose patient specific quality assurance (QA) is recommended by American Association of Medical Physicists (AAPM) and European Society for Radiotherapy and Oncology (ESTRO) for all the complex radiation therapy treatment techniques. Relative and absolute point dose measurement methods are used to verify the TPS computed dose. Relative and absolute point dose measurement techniques have a number of steps to measure the point dose which includes chamber cross calibration, electrometer reading, chamber calibration coefficient, beam quality correction factor, reference conditions, influences quantities, machine stability, nominal calibration factor (for relative method) and absolute dose calibration of machine. Keeping these parameters in mind, the estimated relative percentage uncertainty associated with the absolute point dose measurement is 2.1% (k=1). On the other hand, the relative percentage uncertainty associated with the relative point dose verification method is estimated to 1.0% (k=1). To compare both point dose measurement methods, 13 head and neck (H&N) IMRT patients were selected. A point dose for each patient was measured with both methods. The average percentage difference between TPS computed dose and measured absolute relative point dose was 1.4% and 1% respectively. The results of this comparative study show that while choosing the relative or absolute point dose measurement technique, both techniques can produce similar results for H&N IMRT treatment plans. There is no statistically significant difference between both point dose verification methods based upon the t-test for comparing two means.

NEW ASPECTS OF MEASURING NOISE AND VIBRATION

  • Genuit, K.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.796-801
    • /
    • 1994
  • Measuring noise, sound quality or acoustical comfort presents a difficult task for the acoustic engineer. Sound and noise are ultimately jugded by human beings acting as analysers. Regulations for determining noise levels are based on A-weighted SPL measurement performed with only one microphone. This method of measurement is usually specified when determining whether the ear can be physically damaged. Such a simple measurement procedure is not able to determine annoyance of sound events or sound quality in general. For some years investigations with binaural measurement analysis technique have shown new possibilities for the objective determination of sound quality. By using Artificial Head technology /1/, /2/ in conjunction with psychoacoustic evaluation algorithms - and taking into account binaural signal processing of human hearing, considerable progress regarding the analysis of sounds has been made. Because sound events often arise in a complex way, direct conclusions about components subjectively judged to be annoying with regard to their causes and transmission paths, can be drawn in a limited way only. A new procedure, complementing binaural measurement technology combined with mulit-channel measuements of acceleration sensor signals has been developed. This involves correlating signals influencing sound quality, analyzed by means of human hearing, with signals form different acceleration sensors fixed at different positions of the sound source. Now it is possible to recognize the source and the transmission way of those signals which have an influence on the annoyance of sound.

  • PDF

가상현실 사격훈련을 위한 탄종별 K2 소화기의 주퇴산출 및 분석 연구 (A Study on K2 Rifle Recoil Measurement and Analysis for Virtual Reality Marksmanship)

  • 김종환;진영호;곽윤기
    • 품질경영학회지
    • /
    • 제48권1호
    • /
    • pp.13-27
    • /
    • 2020
  • Purpose: The purpose of this study is to present a recoil measurement and analysis of K2 rifle for the development of a virtual reality marksmanship training in the Republic of Korea Army. Methods: For the recoil measurement, a test-bed is built by a barrel that has exact dimensions of K2 rifle and three piezoelectric pressure sensors mounted on the barrel. Data of over 200 rounds of 5.56mm M193 and K100 bullets are collected and analyzed from live fire experiments. For the recoil analysis, both the free recoil method and the gas exhaust aftereffect method are used to calculate a recoil velocity, momentum and kinetic energy of K2 rifle by applying the law of conservation of momentum. In addition, a new method is proposed that uses the third law of motion and the chamber pressure model for the recoil measurement Results: The results show how different between the previous and proposed methods with respect to M193 and K100 bullets of K2 rifle. In M193, the free recoil method demonstrates 1.113, 4.197, and 2.335, the gas exhaust aftereffect method computes 1.698, 6.407, and 5.441, and the proposed method calculates 0.990, 3.734, and 1.848 in recoil velocity, momentum and kinetic energy, respectively. In K100, the free recoil method demonstrates 1.190, 4.487, and 2.669, the gas exhaust aftereffect method computes 1.776, 6.699, and 5.949, and the proposed method calculates 1.060, 3.998, and 2.119 in recoil velocity, momentum and kinetic energy, respectively. Conclusion: This study implements live fire experiments to provide recoil velocity, momentum, and kinetic energy of K2 rifle using both M193 and K100 bullets. For the development of the army virtual reality marksmanship, the results in this paper would be useful to design and produce a gun and/or a rifle of virtual reality.

몬테카를로 방법과 ISO-GUM 방법의 불확도 평가 결과 비교 (Comparison of ISO-GUM and Monte Carlo Method for Evaluation of Measurement Uncertainty)

  • 하영철;허재영;이승준;이강진
    • 대한기계학회논문집B
    • /
    • 제38권7호
    • /
    • pp.647-656
    • /
    • 2014
  • 본 연구에서는 ISO GUM(불확도 표현 지침서)의 불확도 평가 방법을 보완하기 위해, 몬테카를로 방법(Monte Carlo Method, MCM)을 적용한 불확도 해석 프로그램을 개발하고, MCM과 GUM의 평가 결과를 비교하였다. 그 결과 다음과 같은 결과를 도출하였다. 첫째, 측정량의 확률 분포가 정규 분포가 아닌 때에도 MCM 방법은 정확한 포함 구간을 제공한다. 둘째, 정규 분포가 아닌 다른 분포들 몇몇 개가 합성되는 경우 그 확률 분포가 정규로 보이더라도 실제로는 정규가 아닌 경우가 있으며, 이의 판단은 합성 분산의 확률 분포로 할 수 있다. 셋째, 자유도가 낮은 A형 불확도가 불확도 평가에 포함된 경우 GUM은 포함 구간을 저평가하는 것을 알 수 있었고, 이러한 저평가 문제는 A형 표준 불확도에 t-분포의 표준 편차를 곱해주면 사라지는 것을 알 수 있었다. 이 경우 합성 분산의 유효 자유도는 확장 불확도 계산에 불필요하고, 신뢰의 수준 95 %의 포함 인자는 1.96이 적정한 것을 알 수 있었다.