• Title/Summary/Keyword: Quality Measurement Method

Search Result 1,468, Processing Time 0.027 seconds

Measurement of Electrical Insulating Oil Oxidation by Evaluating the UV Fluorescence Emission Ratio (자외선 형광 방출비 평가에 의한 전기 절연유의 산화측정)

  • Wicaksono, Britantyo;Kong, Hosung;Han, Hung-Gu
    • Tribology and Lubricants
    • /
    • v.29 no.1
    • /
    • pp.51-55
    • /
    • 2013
  • In this work, a new fluorescence emission measurement technology was introduced and experimentally compared with other measurement methods, such as the titration method and IR spectroscopy, to validate it for the oil oxidation measurement of electrical insulating oil. The oxidation characteristics of insulating oil were found to be fairly represented by the titration method and IR spectroscopy, and the results are comparable to a change in the fluorescence emission ratio that is defined as the shift in fluorescence intensity in the measured wavelength range. The result also shows that by the measurement of fluorescence emission ratio, it is possible to detect the oxidation of oil relatively earlier than by other methods. This study suggests that the developed technology can provide sufficient information for evaluating the insulating oil quality, and that the developed FER sensor can be used as an effective condition monitoring device of electrical insulating oil oxidation.

A Study on the surface and analysis of phase map using optical interferometer (광 간섭계를 이용한 표면 및 위상지도 분석에 관한 연구)

  • Park, June-Do;Shin, Soo-Yong;HwangBo, Seung;Kang, Yong-Chel
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.436-437
    • /
    • 2005
  • 3-dimension object's feature measurement is used several industrial field to produce for examination of demanded high quality products by using optical measurement method. 3-dimension object's feature measurement is separated surface scanning and surface non-scanning. In this research, we illuminated interfero-pattern to object, it was constructed with Michelson interferometer by using laser is one of surface non-scanning method. And we extracted phase-map, it is one of featural measurement analysis of 3-dimensional object by using a phase shifting theory.

  • PDF

Study on the unification between KS I ISO standard and official test method enacted by Korean Ministry of Environment - drinking water and indoor air quality - (환경오염공정시험기준과 KS ISO규격의 일원화에 관한 연구 - 먹는 물 및 실내공기질 -)

  • Lee, Jeong-Il;Lee, Ju-Hee;Lee, Jeong-Hee;Lee, Jun-Hee;Lee, Won-Seok;Kim, Ji-In;Kim, Bo-Kyung;Choi, Sung-Hun
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.102-113
    • /
    • 2012
  • Our study researched on unification of KS I ISO standard harmonized with ISO and Official Test Method enacted by Korean Ministry of Environment-drinking water and indoor air quality. We reviewed KS methods related to drinking water and indoor air quality for about 23,000 KS methods. KS methods related environmental field are classified as KS I, total 635 methods and 583 KS I methods were harmonized with ISO. For Environmental Standard methods for drinking water, 100 methods were reviewed according to 232 KS methods related to ISO/ TC 147 "Water Quality". Environmental Standard methods for indoor air quality were reviewed according to 95 KS standard methods related to ISO/TC 146 "Air Quality". By reviews and comparison tests for unifiable ES for drinking water and indoor air quality with KS methods harmonized with ISO, it was evaluated that for 100 ES methods for drinking water, 23 ES methods were unification complete, 29 ES methods were unification possible, 12 ES methods were unification impossible, no corresponding methods were found in KS I ISO for 36 ES methods and for 17 ES methods for indoor air quality,1 ES methods were unification complete, 3 ES methods were unification possible, 3 ES methods were impossible, no corresponding methods were found in KS I ISO for 10 ES methods.

Power Quality Measurement for LED-based Green Energy Lighting Systems (LED 기반 그린에너지 조명시스템을 위한 전력품질 측정)

  • Yu, Hyung-Mo;Choi, Jin-Won;Choe, Sangho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.174-184
    • /
    • 2013
  • For the successful R&D and deployment of LED-based green energy lighting systems, the real-time power quality measurement of both various non-linear power signals including pulse waveform, spike waveform, etc and the undesired-signals including harmonics, sag, swell, etc is required. In this paper, we propose a low-cost power quality measurement (PQM) method for low- (60Hz-several KHz) to high-frequency (several tens KHz) power signals, which are generated by green-energy lighting systems, and implement a PQM testbed using TI TMS320F28335 MCU. The proposed algorithm is programmed using C in the CCS (Code Composer Studio) 3.3 environment and is verified using test signals generated by an arbitrary signal generator, NF-WF1974. In the implemented testbed, we can measure various non-linear current signals that LED SMPS generates, analyze harmonics by fast Fourier transform, and test sag, swell, and interruption using wavelet transform.

Methodologies to Develop Payment Adjustment Regulations for Quality Control and Assurance of Concrete Pavements (콘크리트 도로 포장의 품질 관리 및 보증을 위한 지불규정 개발 기법)

  • Kim, Seong-Min;Rhee, Suk-Keun;Seo, Bong-Kyo
    • International Journal of Highway Engineering
    • /
    • v.10 no.3
    • /
    • pp.179-188
    • /
    • 2008
  • This study was performed as part of the development of the payment adjustment regulations for ensuring high performance of concrete pavements. The objectives of this study were to develop the reasonable quality measurement approaches for the implementation of the payment adjustment regulations and to propose the methods to determine the quality dependent pay factors. First, by using the statistics the slab thickness measurement data was analyzed and the methods to determine the allowable measurement errors, the proper measurement spacing, and the selection of the measurement location were proposed. In addition, to suggest the reasonable methods to determine the pay factors, by using the data of the slab thickness and concrete flexural strength, the pay factors based on the PWL(Percent Within Limits) method used in the USA were compared with those obtained considering the normal probability distribution and t distribution. Finally, the most appropriate method to determine the pay factors was proposed.

  • PDF

A study on the nondestructive measurement of meat quality using visible light (가시광을 이용한 육질의 비파괴적 측정에 관한 연구)

  • Maeng, Gab-joo;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.248-250
    • /
    • 2009
  • In order to know the characteristics of meat quality, we performed experiment using optical method. The characteristics of meat quality was measured by using spectrum analysis and we can obtain the meat quality by experiment value of distribution of meat and fat.

  • PDF

Kyphotic Angle Measurement Accuracy for Vertebral Osteoporotic Compression Fracture; Reliable Method for Kyphotic Angle Measurement

  • Hong, Jae-Taek;Lee, Sang-Won;Son, Byung-Chul;Sung, Jae-Hoon;Park, Choon-Keun;Kim, Moon-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.256-259
    • /
    • 2006
  • Objective : Having a reliable and reproducible measurement technique to measure the sagittal contour in vertebral fractures is paramount to clinical decision making. This study is designed to determine the most reliable measurement technique in osteoporotic vertebral compression fracture. Methods : Fifteen lateral radiographs of thoracic and lumbar fractures were selected and measured on two separate occasions by three spine surgeons using six different measurement techniques [Centroid, Harrison Posterior Tangent Methods and 4 different types of modified Cobb method]. The radiograph quality was assessed and the center beam location was determined. Statistical analysis including ANOVA for repeated measures was carried out using the SAS software [v 8.0]. Results : The inter and intraobserver variance of the Cobb method 4 and Harrison posterior tangent method were significantly lower than the other four methods. The intraobserver correlation coefficients were the most consistent using the Cobb method 4 [0.982]. which was followed by the Harrison posterior tangent [0.953] and Cobb methods 1 [0.874]. The intraobserver agreement [% of repeated measures within 5 degrees of the original measurement] ranged from 42% to 98% for each technique for all three observers, with the Cobb method 4 showing the best agreement [97.8%] followed by the Harrison posterior tangent method [937%]. Conclusion : The Cobb method-4 and Harrison posterior tangent methods, when applied to measuring the kyphosis, are reliable and have a similar small error range. The Cobb method 4 shows the best overall reliability. However, the centroid method and Cobb method using a fractured endplate do not produce an accurate result due to inter and intraobserver differences in determining the baseline.

Application of Laser Slit Beam to Characterize Yarn Irregularity

  • You Huh;Kim, Jong S.;Do W. Kwack;M.W. Suh
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10a
    • /
    • pp.77-78
    • /
    • 2003
  • The surface evenness and texture of textile products are closely related with the irregularity of yarn thickness which has an important role to influence the quality and the process efficiency. For measuring yam thickness the capacitive method is known to dominate the market, delivering results that are in a close relation with the mechanical properties of yarn, while the optical method offers information that seems related rather with the apparent quality of yarn. If a thin light beam is applied for the optoelectrical measurement, it is very possible that this method can provide us with important information which is not obtainable from the capacitive type measurement. This paper reports the results of a study about the yarn thickness and its variation on the basis of a new measurement system using a laser slit beam. Analysis of the new system confirms that we can extract new information on the yarn irregularity ranging into much short wavelengths. Even the visual shade created by the yam doubling and twisting can be measured and represented well. Depending on the yam types, the thickness measurements show their own characteristics.

  • PDF

A Method of Stereoscopic 3D Image Quality Assessment (스테레오스코픽 3D영상 화질 평가 방법)

  • Park, Young-Soo;Hur, Nam-Ho;Pyo, Kyung-Soo;Song, Chung-Kun
    • Journal of Broadcast Engineering
    • /
    • v.16 no.2
    • /
    • pp.319-330
    • /
    • 2011
  • For objective assessment of stereoscopic 3D image quality, we measure quality of left and right image with 2D image quality measurement method. However, this method is inconvenient because that we have to measure quality of left and right image individually. Therefore we propose a method of stereoscopic 3D image quality assessment using one overlaid image with left and right image. Using this method, One can measure quality of stereoscopic 3D image more easily and quickly.

An Experimental Study on the Application of Measuring Method of Water Content for Quality Control of Concrete (콘크리트 품질관리를 위한 단위수량 측정 기법의 적용성에 관한 실험적 연구)

  • Kim, Yong-Ro;Choi, Il-Ho;Jung, Yang-Hee;Lee, Do-Bum
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.179-188
    • /
    • 2007
  • Recently, the concern on the receipt of poor ready-mixed concrete in the construction field and the durability of concrete has been increased. Based on the such background, a large number of measuring methods of water content for fresh concrete have been developed and enforced in a developed country. In this study, to investigate practicality for quality control of ready-mixed concrete among various water content measurement techniques, microwave range method, air meter method and capacitance measurement method as measuring methods of water content were selected. Then, it was evaluated estimating performance of water content according to the change of binder types, fine aggregate types, absorption ratio, water content and water-binder ratio in series I and II. Also, it was examined influence on error occurrence of water content according to change of properties of used materials in series III. Finally, based on this study, it was proposed fundamental data to utilize measurement technique of water content to quality control of ready-mixed concrete in construction field.