• Title/Summary/Keyword: Quality Measurement Method

Search Result 1,468, Processing Time 0.03 seconds

Development of Rail Profile Measurement System using High Speed Laser Image Processing (고속영상처리에 의한 레일형상측정시스템 개발)

  • Moon, Chul-Yi;Kim, Man-Chul
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1320-1325
    • /
    • 2006
  • Railway track supports and guides train and it directly affects ride quality and safety. To maintain track quality, regular maintenance activity is essential but it degrades track usage since maintenance activity occupies the track during the work. To achieve maximum track efficiency, track inspection should be performed at commercial running speed. In this paper, we designed and developed high speed rail profile measurement system using laser light sectioning method with line laser generator, digital camera and DSP based image processing system. The measurement system can supports rail profile measurement at the speed of 300 Km/h that can be applied to KTX.

  • PDF

A Study on the Performance of Quality Small-Group Activity (품질소집단 활동의 성과에 관한 연구)

  • Chung, Young-Bae;Kim, Yon-Soo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.34 no.4
    • /
    • pp.42-48
    • /
    • 2011
  • This paper proposes performance measurement method of quality small-group activity in business. This paper collects and analyzes quality circle activities data respect to tangible and intangible effect in national quality circles competitions festival. This paper proposes QPI (quality-circle performance index) based on Balanced Scorecard for quality small-group activity in quality improvement area. QPI is to measure the performance of quality improvement activities in the business firms. QPI is able to use widely in industries to provide a performance measure of quality small-group activity. In this paper, we propose the application method of QPl.

User Experience Measurement for Senior Friendly Product

  • Jung, Kwang Tae;Chun, Keyoung Jin;Won, Byeong Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.557-563
    • /
    • 2013
  • Objective: This study introduces user experience measurement and its application for senior friendly products. Background: Measuring user experience for senior friendly product is very important for its design, but the measurement is not easy. Method: This study was focused on case studies for user experience measurement and its application for senior friendly product. Mobile patient lift and four wheeled walker that assist the old's mobility were studied. User experience was measured through interview and observation method. Result: From measuring the user experience, some usability issues were identified for the products. A method to apply QFD(quality function deployment) in design process was proposed. A design prototype was also developed considering user experience. Conclusion: User experience measurement for senior friendly products is key process for user centered design. Application: The method and result of this study can be applied to user experience measurement and design of senior friendly product.

A Case Study on the Analysis of Soft Ground Consolidation by the Measurement of Surface Settlement Plate (지표침하판계측을 통한 연약지반 침하분석 사례연구)

  • Kim, Joon-Seok
    • Journal of Urban Science
    • /
    • v.9 no.2
    • /
    • pp.51-56
    • /
    • 2020
  • The installation of soft ground instruments and the performance of measurement and management of the measurement shall be carried out in order to ensure the safety of the construction work and to improve the quality of the construction work. The purpose of the pressure density deposition calculation is to determine the stability of the foundation ground and the formulation by measuring and calculating the density conditions generated on the soil through the period of neglect after completion of the soil at each stage. In practice, it is judged that the analysis by the hyperbolic method can be applied to the safety side.

A New Method for the Determination of Carrier Lifetime in Silicon Wafers from Conductivity Modulation Measurements

  • Elani, Ussama A.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.4
    • /
    • pp.311-317
    • /
    • 2008
  • The measurement of dark ${\sigma}_D$, gamma-induced ${\sigma}_{\gamma}$ conductivities and the expected conductivity modulation ${\Delta}_{\sigma}$ in silicon wafers/samples is studied for developing a new technique for carrier lifetime evaluation. In this paper a simple method is introduced to find the carrier lifetime variations with the measured conductivity and conductivity modulation under dark and gamma irradiation conditions. It will be concluded that this simple method enables us to give an improved wafer evaluation, processing and quality control in the field of photovoltaic materials and other electronic devices.

Bandwidth Expansion Method Using Spline Codebook Based Spectral Folding (Spline 코드북 기반의 spectral folding을 이용한 대역폭 확장 방법)

  • Park, Ji-Hoon;Han, Seung-Ho;Yang, Hee-Sik;Jeong, Sang-Bae;Hahn, Min-Soo
    • Proceedings of the KSPS conference
    • /
    • 2006.11a
    • /
    • pp.131-134
    • /
    • 2006
  • Quality of narrowband speech $(0{\sim}4kHz)$ can be enhanced by the bandwidth expansion technique, by which the high- band components are estimated. This paper proposes the bandwidth expansion method using the spline codebook based spectral folding. For the performance evaluation, the PESQ(Perceptual Evaluation of Speech Quality) scores are measured as the objective measurement In addition, the MOS (Mean Opinion Score) and the preference tests are performed as the subjective measurement. The results show our proposed method outperforms the existing spline based one.

  • PDF

A Study on the Automatic Measurement of Solid Content in Recycled Water in Ready Mixed Concrete Plant (레디믹스트 콘크리트 플랜트의 회수수 농도 측정 자동화에 관한 연구)

  • Choi, Young-Cheol;Moon, Gyu-Don;Cho, Bong-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.123-131
    • /
    • 2014
  • Whole amount of waste water, approximately 921.6 liter, for cleaning a ready mixed concrete truck should be used to produce concrete as a mixing water or cleaning water. Recycling water for concrete mixing contains solids, which cause decrease in slump, air and compressive strengths, so it may influence on poor concrete quality. Therefore, it has been maintained to use recycling water with less than 3 percent of solids. Since no evaluation system has been constructed to directly reflect on variability of recycling water from ready mixed concrete plants, it is necessary to develop "Automatic recycling solid measuring system" for quality controls in real time. In this research, sensors measuring waste water concentration in ultrasonic and inductance methods were developed, and automatic system using the sensors were established. The accuracy of measurement sensors developed for recycling water based on various conditions of concentration was proved, and application limits were evaluated. Also, concentration of recycling water using sensors developed from ready mixed concrete plant was measured, and curing method verified the accuracy of the sensors. Moreover, measurement sensors for recycling water in various locations were installed to evaluate the effects on measuring method and spots. The automatic measuring system for recycling water concentration, which is developed in the research, will contribute to improve concrete quality safety through reliable solids maintenance.

Uncertainty Evaluation of the Analysis of Methamphetamine and Amphetamine in Human Hair by GC/MS (GC/MS를 이용한 모발 중 메스암페타민 및 암페타민 분석의 측정불확도 평가)

  • Kim, Jin-Young;Kim, Jong-Sang;Kim, Min-Kyoung;Lee, Jae-Il;Suh, Yong-Jun;In, Moon-kyo
    • YAKHAK HOEJI
    • /
    • v.51 no.3
    • /
    • pp.206-213
    • /
    • 2007
  • Recently estimating the uncertainty of an analytical result has become an essential part of quantitative analysis. This study describes the uncertainty of the measurement for the determination of methamphetamine and its major metabolite amphetamine in human hair, The method consists of washing, drying, weighing, incubation and extraction with methanolic HCI solution, clean-up, trifluoroacetyl derivatization, and qualification/quantification of residues by gas chromatography/mass spectrometry (GC/MS). Traceability of measurement was established through traceable standards and calibrated volumetric equipment and measuring instruments. Measurement uncertainty associated with each analyte in real samples was estimated using quality control (QC) data. The main source of combined standard uncertainty comprised two components, which are uncertainties associated with calibration linearity and variations in QC, while those associated with preparation of analytical standards and sample weighing were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method ranged for individual analytes from 4.99 to5.03%.

ECG Measurement Method during Sleep with Array of Capacitive Electrodes Attached to Bed (침대에 부착된 용량성 전극 배열을 이용한 수면 중의 심전도 측정)

  • Lim, Y.G.;Kim, K.K.;Park, K.S.;Jeong, D.U.
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.521-524
    • /
    • 2005
  • In order to measure ECG in daily life, a new ECG measurement method on bed was developed. The provided method does not require any direct conductive contact between the instrument and bare skin, so that it does not cause the uncomfortable feel of touch and the possible skin trouble which are typical shortcomings of the conventional conductive contact ECG measurement. The provided method utilized an array of high-input-impedance active electrodes fixed on the mattress and an indirect-skin-contact ground made of a large conductive textile sheet and laid on lower area of the mattress. A thin cotton bedcover covered the mattress, the electrodes, and the conductive textile and subjects lay on the mattress over the bedcover. ECG was obtained successfully. However its signal quality is lower and the motion artifact is larger than direct-contact measurement. Careful measurement setup was needed to reduce the motion artifact originated from variation in static electricity. From the ECG obtained by the provided method, R-peak could be discriminated easily and the information about the position and the posture of the subject could be obtained.

  • PDF

The Effect of the DIC Speckle Patterns for a Microcrack Measurement (미소균열 측정에 대한 DIC 스펙클 형상의 영향)

  • Lee, Jun Hyuk;Kwon, Oh Heon
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.4
    • /
    • pp.15-21
    • /
    • 2019
  • In order to secure the safety of various machinery, it is very important to develop a technique for accurately and quickly measuring the cracks generated in the mechanical equipment and evaluating the mechanical characteristics. The evaluation of the mechanical properties is accompanied by an appropriate strain measurement according to the material and crack occurrence of the target structure. Especially, when micro cracks are generated, the evaluation method is very important. Digital image correlation is an optical full field displacement measuring method which is using currently with speckles in the interested area. However the evaluation method and conditions of image distributions have to be considered carefully to measure the crack occurrence because the images of the speckle patterns affect the quality of displacement results. In this study, the speckle pattern density is characterized to improve the accuracy of the measurement method. And also the micro crack initiation is detected by the measured displacement in the adopted speckle pattern distribution. It is shown that the proposed method is useful to determine the density pattern distribution for the accurate measurement and crack detection.