Reliability estimation about quality assurance method of radiotherapy planning (방사선치료계획 정도관리 방법에 따른 신뢰도 평가)

  • Kim, Jeong-Ho;Kim, Gha-Jung;Yoo, Se-Jong;Kim, Ki-Jin
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.119-124
    • /
    • 2015
  • According as radiation therapy technique develops, standardization of radiation therapy has been complicated by the plan QA(Quality Assurance). However, plan QA tools are two type, OADT (opposite accumulation dose tool) and 3DADT (3 dimensional accumulation dose tool). OADT is not applied to evaluation of beam path. Therefore tolerance error of beam path will establish measurement value at OADT. Plan is six beam path, five irradiation field at each beam path. And beam path error is 0 degree, 0.2 degree, 0.4 degree, 0.6 degree, 0.6 degree, 0.8 degree. Plan QA accomplishes at OADT, 3DADT. The more path error increases, the more plan QA error increases. Tolerance error of OADT path is 0.357 using tolerance error of conventional plan QA. Henceforth plan QA using OADT will include beam path error. In addition, It will increase reliability through precise and various plan technique.

Image Quality Management Using ALVIM Phantom (ALVIM Phantom을 이용한 화질관리)

  • Im, Deuk-Chun;Dong, Kyung-Rae;Park, Yong-Soon;Kim, Chang-Bok;Ryu, Young-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.63-68
    • /
    • 2009
  • Among various physical or subjective assessments of the quality of X-ray images, physical assessments can be quantitative but they are eventually judged by the view of observers thus subjective assessments including the aspect of observers are required. The changes in the ability to detect lesions caused by changes in the thickness of acrylic plates were tested with the ROC interpretation method that has taken into consideration, all the features of physical assessments as well as observers' ability to observe and mental stages and even surrounding environments using an Alvim phantom and the result indicated that as the thickness of acrylic plates increased, the amount of noises occurred increased compared to signals and thus the ability to detect signals as well as the sensitivity that is an ability to signals accurately and the ability to distinguish noises from signals thus it is considered that more efforts of radiologic technologists will be required to detect small lesions of fat patients with diagnostic X-ray generating apparatus.

  • PDF

A Comparative Study of Image Quality and Radiation Dose according to Variable Added Filter and Radiation Exposure in Diagnostic X-Ray Radiography (진단용 X-선 촬영시 부가 필터 및 노출의 변화에 따른 피폭선량 및 영상 화질 비교 연구)

  • Choi, Nam-Gil;Seong, Ho-Jin;Jeon, Joo-Seop;Kim, Youn-Hyun;Seong, Dong-Ook
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.25-34
    • /
    • 2012
  • To know which parameters were acceptable for achieving lowest radiation exposure to the patients and highest image quality at the diagnostic X-ray radiography, we measured the patient radiation dose and image quality in transmitted PACS (Picture Archiving and Communication System) at variable combinations of the added filters. As a result, the Dose Area Product (DAP: $mGy{\cdot}cm^2$) and Entrance Surface Doses (ESDs: $mGy$) was lowest at 1 mmAl + 0.2 mmCu and highest at 0 mmAl. The histogram of the image quality by transmitted PACS was not significantly different at variable combinations of exposure parameters on the MATLAB. In conclusion, this study can be helpful for expecting radiation dose-exposure and control exposure parameters for the diagnostic X-ray radiography.

Technical Advances, Image Quality and Quality Control Regulations in Mammography

  • Ng, Kwan-Hoong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.38-41
    • /
    • 2002
  • Mammography is considered the single most important diagnostic tool in the early detection of breast cancer. Today's dedicated mammographic equipment, specially designed x-ray screen/film combinations, coupled with controlled film processing, produces excellent image quality and can detect very low contrast small lesions. In mammography, it is most important to produce consistent high-contrast, high-resolution images at the lowest radiation dose consistent with high image quality. Some of the major technical development milestones that have let to today's high quality in mammographic imaging are reviewed. Both the American College of Radiology Mammography Accreditation Program and the Mammography Quality Standards Act have significant impact on the improvement of the technical quality of mammographic images in the United States and worldwide. A most recent development in digital mammography has opened up avenues for improving diagnosis.

  • PDF

A Study on Enforcement Effects of Radiation Safety Control Regulations for Diagnostic X-ray Equipments (진단용 방사선안전관리 현황에 관한 연구)

  • Sung, Mo-Il;Park, Myeong-Hwan;Kwon, Duk-Moon;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.73-78
    • /
    • 1999
  • The purposes of this study are to analyze the realities after enforcements of safety control regulations for diagnostic X-ray equipments and to suggest means for an improvement of low radiation safety control. A questionnaire survey for medical radiologic technologists was carried out to determine enforcement effects of the safety control regulations. The results of analysis from the survey are as follows. That is, most of the respondents realized the importance of the radiation safety control system, but about a half of them revealed that the regulations were not well observed in accordance with their purposes. Only 43.9% of the respondents took an active part in quality control and safety control of radiation. And respondents responsibility, sex, age, and knowledge for safety control were important indicators for observations of the regulations. Trainings for the safety control regulations are needed to ensure safety control and proper usage of diagnostic X-ray equipments. And management of organizations using diagnostic X-ray equipments have to understand and stress the importance of radiation safety control system.

  • PDF

A Case Report of Contact Dermatitis treated by Mahwang-tang based on Shanghanlun Provisions (『상한론(傷寒論)』 변병진단체계(辨病診斷體系)에 근거하여 마황탕(麻黃湯) 투여 후 호전된 접촉성피부염 1례)

  • Yun, Hyo-Joong;Ha, Hyun-yee;Rho, Yeong-Beom
    • 대한상한금궤의학회지
    • /
    • v.8 no.1
    • /
    • pp.53-65
    • /
    • 2016
  • Objective : The purpose of this paper is to report the improved contact dermatitis(CD) treated with the herbal medication based on Shanghanlun disease pattern identification diagnostic system. The level V steroid ointments were no use to the patient 3weeks before the treatment. Methods : In this case, the patient was diagnosed according to 'Disease Pattern Identification Diagnostic System based on Shanghanlun Provisions' and took Mahwang-tang for 36days since the final diagnosis was Taeyang-byung, number 46 provision. The photographs of patient's hands were taken to observe the process of the skin status and the discomfort from CD was measured with DLQI(Dermatologic Life Quality Index) and NRS(Numeric Rating Scale). Results : The DLQI score changed from 24 to 7 and NRS of itching changed form 8 to under 4. Conclusions : This case report shows that the herbal medication through the diagnostic system could be a remedy on CD, dealing with the skin status with no use of the level V steroid ointments. It is needed proving an alternative possibility of Korean Medicine, on other skin diseases, with later studies since there are many reports on the side-effects after some long-term steroid treatments.

Development of Farm Management Diagnostic Checklist Reflecting Crop Characteristics (작물 특성을 반영한 농가경영진단표 개발)

  • Choi, Don-Woo;Lim, Cheong-Ryong
    • Journal of Korean Society of Rural Planning
    • /
    • v.23 no.2
    • /
    • pp.1-7
    • /
    • 2017
  • The purpose of this study is to develop a farm management diagnostic checklist form, which can be applied to any crops. First, upper indexes and subordinate indexes were identified through survey with expert, and weighted values for each subordinate index were calculated through AHP analysis. Second, as a reuslt of Analytic Hierarchy Process (AHP) analysis, marketing management (0.276) was found to be the most important index of all upper indexes. In the case of subordinate indexes, reflecting management evaluation (0.252) of management consciousness, quality enhancement efforts (0.332) of production management, locating new sales outlets (0.323) of marketing management, agriculture accounting (0.300) of finance management, and adjusting shipping dates (0.274) of risk management were found to be the highest. Third, the interval division using weight of farm receiving prices was higher discrimination in comparison to equal interval division of weighted values for each index. The newly developed farm management diagnostic checklist can be applied to any crops, as it utilizes indexes such as management consciousness, production management, marketing management, financial management, risk management, etc. based on professional opinions. In addition, it allows an objective evaluation of farm management situations by utilizing the weighted value of farm receiving prices.

A Study on Development of Diagnostic Index for Measure of Rural Villages Landscapes Level (농촌마을단위 경관진단지표 개발에 관한 연구)

  • Song, Hee-Jung;Kim, Dae-Sik
    • Journal of Korean Society of Rural Planning
    • /
    • v.19 no.3
    • /
    • pp.107-116
    • /
    • 2013
  • In this study, it provides the diagnostic index for the rural landscape formation. For the development of diagnostic index, this study first analyzed documents and papers on the landscape formation. Landscape types are also classified by their function and then landscape index was developed by AHP method. Classification system was categorized as three steps: 2 items for 1st step, 10 items for 2nd step, and 20 items(criteria) for 3rd step. In the survey of weighting values with AHP method, the analysis result for the first step showed that rural village landscape is more important than landscape around the village by approximately 20%. In the second step, residence is rated as the most important, followed by village tree planting, and then farmland around the rural villages, greenery, and water environment. In the third step, the feng shui is rated as the most important, followed by tree planting, village forest, culture, and history. While vehicle maintenance, village alleys and pedestrian facilities are rated lower. In index of the around the village, weighting value for index of the farm land and skyline has the highest value. While species richness, water quality and water resources were rated relatively low. In the future, the rural landscapes diagnosis index will be applied to measure the level of the rural villages landscapes and it is expected to propose political support for the landscapes formation.

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

Assessment of Insulation Deterioration in Stator Windings of High Voltage Motor (고압전동기 고정자 권선의 절연열화 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.5
    • /
    • pp.711-716
    • /
    • 2012
  • To assess the insulation deterioration of stator windings, diagnostic and AC breakdown tests were performed on the eleven high voltage (HV) motors rated at 6kV. After completing the diagnostic tests, the AC overvoltage test was performed by gradually increasing the voltage applied to the stator windings until electrical insulation failure occurred, to obtain the breakdown voltage. Stator winding of motors 1, 3, and 8 failed at above rated voltage at 14 kV, 13.8kV, and 16.4kV, respectively. The breakdown voltage of three motors was higher than expected for good quality windings in 6kV motors. Based on deterioration evaluation criteria, the stator winding insulation of eleven HV motors are confirmed to be in good condition. The turning point of the current, $P_{i2}$, in the AC current vs. voltage characteristics occurred between 5kV and 6kV, and the breakdown voltage was low between 13.8kV and 16.4kV. There was a strong correlation between the breakdown voltage and various electrical characteristics in diagnostic tests including Pi2.