• 제목/요약/키워드: Quality Deviation

검색결과 919건 처리시간 0.03초

Site Quality Evaluation Prototype for Building Deck-plate Construction

  • Shim, Young-Bo;Cho, Dong-Hyun;Koo, Kyo-Jin
    • 한국건축시공학회지
    • /
    • 제13권1호
    • /
    • pp.90-100
    • /
    • 2013
  • Deck-plates are widely used on construction sites, and have the advantage of enabling contractors to achieve a relatively uniform quality. But nevertheless, quality deviation in deck-plate construction can occur as the result of differences in site conditions and the experience of crew workers. In this study, the authors present a site quality evaluation prototype for building deck-plate construction. Through analyses of case studies and interviews with experts, standard quality check sheets and a quality management index were developed by estimating the importance of quality check items based on a Failure Mode and Effects Analysis (FMEA) method. The applicability and effectiveness of the prototype was evaluated through a case study and interviews with case participants. It was found that the prototype promoted an active quality management as a way of continuously improving quality management in deck-plate construction instead of passive quality inspection practice.

마모공정에 대한 정량 보정계획 (A Fixed Amount Compensation Plan for a Tool Wear Process)

  • 최인수;이민구
    • 산업경영시스템학회지
    • /
    • 제19권40호
    • /
    • pp.233-240
    • /
    • 1996
  • A fixed amount compensator is proposed for a process with a linear tool wear function. A Cost model is constructed which involve process adjustment cost and quality loss. Symmetric and asymmetric quadratic functions of the deviation of a quality measurement from the nominal target value are considered as the quality loss functions. Methods of finding optimal values of initial setting and compensation limit are presented and a numerical example is given.

  • PDF

치수인자를 이용한 특수 인쇄 배선기판의 품질향상에 관한 연구 (A Study on the Quality Improvement of Special Printed Wire Board Using Scale Factor)

  • 전영호
    • 품질경영학회지
    • /
    • 제22권4호
    • /
    • pp.152-159
    • /
    • 1994
  • A study of improvement of printing accuracy of special PCB has been carried out by applying the corrected data of laminate dimensional variation to real products. The result of this study improved the accuracy of product by decreasing the deviation between design specifications and end products. This paper will be useful when PCB manufacturers using paper phenol laminates make preparation for customer's needs, more complicated specifications. And so, it will be successful for image renovation of any company by assuring the reliabilities to customers.

  • PDF

박물관 실내공기질 변동에 관한 연구 (Variation of Indoor Air Quality in Museum)

  • 이정주;김신도;부문자
    • 한국환경보건학회지
    • /
    • 제22권4호
    • /
    • pp.43-48
    • /
    • 1996
  • Indoor air quality(IAQ) in museum is very important for protection of cultural properties. In our study, we measured air pollutants($NO_x, NH_3, SO_2, O_3$, CO, $CO_2$, TSP), temperature and humidity to evaluate IAQ of national central museum. Indoor carbon dioxide and TSP concentrations were higher than outdoor concentrations. Temperature, huinidity and TSP had large deviation depending on air conditioning operates or not. Indoor gas phase pollutants except $CO_2$ were lower than outdoor concentrations, but $SO_2$ concentration was high in storage. $CO_2$ and TSP were influenced by the number of spectators.

  • PDF

A Study on the Quality of Photometric Scanning Under Variable Illumination Conditions

  • Jeon, Hyoungjoon;Hafeez, Jahanzeb;Hamacher, Alaric;Lee, Seunghyun;Kwon, Soonchul
    • International journal of advanced smart convergence
    • /
    • 제6권4호
    • /
    • pp.88-95
    • /
    • 2017
  • The conventional scan methods are based on a laser scanner and a depth camera, which requires high cost and complicated post-processing. Whereas in photometric scanning method, the 3D modeling data is acquired through multi-view images. This is advantageous compared to the other methods. The quality of a photometric 3D model depends on the environmental conditions or the object characteristics, but the quality is lower as compared to other methods. Therefore, various methods for improving the quality of photometric scanning are being studied. In this paper, we aim to investigate the effect of illumination conditions on the quality of photometric scanning data. To do this, 'Moai' statue is 3D printed with a size of $600(H){\times}1,000(V){\times}600(D)$. The printed object is photographed under the hard light and soft light environments. We obtained the modeling data by photometric scanning method and compared it with the ground truth of 'Moai'. The 'Point-to-Point' method used to analyseanalyze the modeling data using open source tool 'CloudCompare'. As a result of comparison, it is confirmed that the standard deviation value of the 3D model generated under the soft light is 0.090686 and the standard deviation value of the 3D model generated under the hard light is 0.039954. This proves that the higher quality 3D modeling data can be obtained in a hard light environment. The results of this paper are expected to be applied for the acquisition of high-quality data.

Comparison between Isokinetic Peak Torque and Isotonic 1RM on the Knee Joint

  • Jaehyun Yoo
    • Physical Therapy Rehabilitation Science
    • /
    • 제12권2호
    • /
    • pp.201-205
    • /
    • 2023
  • Objective: Resistance exercise is a necessary element to improve quality of life, and measurement and evaluation of muscle strength provide important information for prescription and management of rehabilitation and exercise programs. This study analyzed the correlation between direct and indirect 1RM for isokinetic maximum torque of the knee joint in order to provide useful information in the field of exercise programs. In addition, the flexion-extension ratio and the difference in left-right deviation were verified. Design: A cross-sectional study Methods: The subjects of this study were 33 healthy adult men and women without medical problems who participated in the health exercise class program at S University in Seoul. The correlation between isokinetic maximum torque and direct and indirect 1RM was analyzed, and a dependent t-test was performed to analyze the flexion-extension ratio and left-right deviation. Results: There was a high correlation between the isokinetic maximum torque and direct and indirect 1RM, and no statistically significant difference was shown between the test methods in the analysis of the flexion-extension ratio and left-right deviation. Conclusions: Isokinetic muscle function measuring equipment is expensive, so it is difficult to use it in local exercise rehabilitation and training sites. Through this study, it was found that direct and indirect 1RM isokinetic maximum torque showed a high correlation, and there was no difference in evaluating muscle function such as flexion-extension ratio and left-right deviation. Therefore, it is considered that the muscle function evaluation using 1RM in general field can be usefully utilized.

평균 샘플 수 최소화를 통한 계량형 반복 샘플링 검사의 설계 (A Variables Repetitive Group Sampling Plan for Minimizing Average Sample Number)

  • 박희곤;문영건;전치혁;;이재욱
    • 대한산업공학회지
    • /
    • 제30권3호
    • /
    • pp.205-212
    • /
    • 2004
  • This paper proposes the variables repetitive group sampling plan where the quality characteristic following normal distribution has upper or lower specification limit. The problem is formulated as a non-linear programming problem where the objective function to minimize is the average sample number and the constraints are related to lot acceptance probabilities at acceptable quality level (AQL) and limiting quality level (LQL) under the operating characteristic curve. Sampling plan tables are constructed for the selection of parameters indexed by AQL and LQL in the cases of known standard deviation and unknown standard deviation. It is shown that the proposed sampling plan significantly reduces the average sample number as compared with the single or the double sampling plan.

규격화된 구내 표준 방사선사진의 계수 공제 방사선학적 평가 (DIGITAL SUBTRACTION RADIOGRAPHIC EVALUATION OF THE STANDARDIZED PERIAPICAL INTRAORAL RADIOGRAPHS)

  • 조봉혜;나경수
    • 치과방사선
    • /
    • 제23권1호
    • /
    • pp.125-136
    • /
    • 1993
  • The geometrically standardized intraoral radiographs using 5 occlusal registration materials were taken serially from immediate, 1 day, 2, 4, 8, 12, and 16 weeks after making the bite blocks. And the resultant images were digitally subtracted using the immediately taken film as reference images. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exal1ex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. the lesser the standard deviation, the better the quality of the subtracted images. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  • PDF

수평 microchannel의 $CO_2$ 비등열전달 (Boiling Heat Transfer Characteristics of $CO_2$ in Horizontal Smooth Microchannel)

  • 최광일;;오종택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.241-246
    • /
    • 2007
  • The present paper dealt with an experimental study of boiling heat transfer characteristics of $CO_2$. Heat transfer coefficients of the refrigerant flow inside horizontal smooth microchannel were obtained with inner tube diameter of 0.3mm and length of 300mm. The direct electric heating method was applied for supplying the heat uniformly to the refrigerant. The experiments were conducted with $CO_2$ purity of 99.99%, at saturation temperature of $10^{\circ}C$, mass flux ranges of $300{\sim}900\;kg/m^2s$, and heat flux ranges of $15{\sim}45\;kW/m^2$. While heat transfer coefficient increased with the increase of heat flux in the low quality region, the heat transfer coefficient decreased with the increase of quality in the high quality region. The heat transfer coefficients were compared with seven existing correlations with the Gungor-Winterton's(1986) correlation gave the best prediction. A new corelation to predict the two-phase flow heat transfer coefficient was developed based on the Chen(1966) correlation. The new correlation predicted the experimental data well with a mean deviation of 9.69% and average deviation of -3.03%.

  • PDF

시장 출하 '거봉' 및 '캠벨얼리' 포도의 등급과 품질 조사 (Comparison of 'Kyoho' and 'Campbell Early' Table Grape Fruit Quality in Wholesale Market)

  • 황용수;임병선;김진국
    • 농업과학연구
    • /
    • 제37권1호
    • /
    • pp.7-12
    • /
    • 2010
  • A significant difference in table grape quality was found between harvest seasons, producers and cultivars. In general, 'Kyoho' grapes showed much greater difference in fruit quality than 'Campbell Early'. The ratio of 'Campbell Early' grapes with poor quality (below quality standard within grades), was higher in fruit harvested early in the season, mainly because of immature fruit harvest. In 'Kyoho', poor quality of fruit seemed to be derived from the deviation of cultural practice between producers. Major factors responsible for poor quality in both cultivars includes harvest of unripe cluster, poor sorting and grading, berry abscission, and poor coloration. It is recommended to introduce a new quality standards considering the market condition in 'Kyoho' or a fresh-cut technology of grape berries for niche market.