• Title/Summary/Keyword: Quality Determination

Search Result 1,369, Processing Time 0.034 seconds

Study on Improvement in Reliability of Analysis for VOCs and Aldehydes (대기 중 휘발성유기화합물질 및 알데하이드의 분석 신뢰도 향상에 관한 고찰)

  • Lee M.D.;Lee S.U.;Lim Y.J.;Kim Y.M.;Kim S.Y.;Moon K.J.;Han J.S.;Chung I.R.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.4
    • /
    • pp.468-476
    • /
    • 2006
  • Hazardous air pollutants (HAPs) have high toxicity and bioaccurnulation potentials into human body even inbsmall amount (levels of ng/$m^3$). As the levels of HAPs might be controversial, it has been become essential to establish the analysis method for correct results. In this study, various analysis methods of VOCs and Aldehydes were compared in order to select the proper methods in our condition. Sampling and analysis method of VOCs were followed to EPA TO-14a and TO-17. VOCs were collected in absorption tube and separated by thermal desorption unit then analyzed by GC/MSD. Aldehydes were sampled in DNPH-cartridge and extracted into solution then analyzed by HPLC as the same condition of EPA TO-13a. This study also shows the results of QA/QC system of selected methods. Some experiments could be improving the data assurance blank test, calibration check, repetition precision check, the determination of detection limit and reproducibility of the retention time. Precisions of VOCs and aldehydes were ranged in 2$\sim$9% and 1$\sim$4% RSD, respectively. Recovery rate of VOCs showed variable ranges from 60 to 133.5%. MDL of VOCs and aldehydes were 0.044$\sim$0.284 ppb and 0.14$\sim$1.02 ng, respectively.

Determination of the quality of stripe-marked and cracked eggs during storage

  • Liu, Yu Chi;Chen, Ter Hsin;Wu, Ying Chen;Tan, Fa Jui
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.7
    • /
    • pp.1013-1020
    • /
    • 2017
  • Objective: Stripe marks, which occasionally occur on the shell, do not cause breakage to the shell and shell membranes of eggs. This study investigated the quality of intact eggs (IEs), minor stripe-marked eggs (MEs), severe stripe-marked eggs (SEs), and cracked eggs (CEs) during 3-week storage at $25^{\circ}C$. Methods: Shell eggs were collected the day after being laid and were washed. Among them, eggs without any visual cracks or stripe marks on the shells were evaluated as IEs by the plant employees using candling in a darkened egg storage room; the remaining eggs exhibited some eggshell defects. At day 3, the eggs were further categorized into IEs, MEs, SEs, CEs, and broken eggs (BEs) on the basis of the description given. Except BEs, which were discarded, the remaining eggs were stored at $25^{\circ}C$ (approximate relative humidity 50%) and then analyzed. Results: Stripe marks were observed primarily within the first 3 days after washing. At day 3, CEs had significantly (p<0.05) lower Haugh unit values, but all eggs had grades AA or A, according to the United States Department of Agriculture standard. As storage time increased, differences in egg quality between groups were more obvious. IEs had the highest eggshell breaking strength. During storage, the total plate counts and pathogens, namely Escherichia coli, Campylobacter spp., Staphylococcus aureus, and Salmonella spp., were not detectable in the internal content of IEs and SEs. Conclusion: In conclusion, cracks degraded egg quality severely and minor stripe marks only slightly influenced the egg quality.

The Advanced Analytical Method Through the Quantitative Comparative Study of Taurine in Feed Using LC-MS/MS

  • Seon, Yeong Jun;Seo, Hyung Ju;Yoon, Jiye;Cho, Hyunjeong;Hong, Sunghie;Lee, Seung Hwa;Na, Tae Woong
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.133-138
    • /
    • 2022
  • Taurine is a type of sulfur-containing amino acid having a sulfate functional group, that is biosynthesized from cysteine. It is mainly distributed in high concentrations in animal tissues and is known to have various effects such as osmotic pressure control, calcium control, anti-inflammatory, antioxidant, and hepatocellular protection. Also, taurine deficiency causes a variety of symptoms, including visual impairment. In particular, in the case of cats, taurine is not biosynthesized and must be supplied through food, so it is classified as an essential amino acid. In this study, an analysis method using mass spectrometry was developed instead of the commonly used derivatization method to quickly, environmentally, and precisely analyze taurine in various animal feeds. The developed analytical method showed good linearity (R2 > 0.99), accuracy (81.97-105.78%), and precision (0.07-12.37%). In addition, the developed method was further verified through quantitative comparison with the derivatization method. This developed method was used in the determination of taurine in 20 animal feed samples obtained from South Korea. The levels of taurine found ranged from 81.53 to 6,743.53 mg/kg. The developed analysis method will be used for the detection and quantification of taurine in domestic feed.

Attitude Determination Technique using Ultrasound and RF Signal (초음파와 RF를 이용한 자세결정)

  • Kim, Seung-Beom;Kang, Dong-Youn;Yun, Hee-Hak;Lee, Geon-Woo;Lee, Sang-Jeong;Park, Chan-Sik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.10
    • /
    • pp.1025-1031
    • /
    • 2007
  • GPS is widely used for positioning applications and attitude of a vehicle can be found also with multiple antennas. However, extremely weak signal level prevents GPS from indoor operation. DR with accelerometers and gyros and landmark based localization method used for indoor applications increase complexity and cost. In this paper, a simple but very efficient ultrasound based attitude determination system which determines both position and attitude in WSN is given. The range between transmitter and receivers are measured using the arrival time difference between ultrasound and RF signal. The 3 dimensional positions can be found using more than 3 range measurements. Furthermore, if more than 2 transmitters are used, the attitude can be determined using the baseline vectors obtained by differencing transmitter and receiver positions. The prototype system is implemented to evaluate the performance of the proposed method. In addition, an error analysis shows the relation between the attitude error and basel me length, quality of measurement and orientation of a vehicle. The static and dynamic experiments performed by micro mobile robot shows accurate position with less than 1.5cm error and attitude with less than 1 degree error can be obtained continuously with 20cm baseline. It is expected that these results can be adapted without modification to indoor applications such as home cleaning robot and autonomous wheelchair maneuvering.

Parametric Analysis of the Solar Radiation Pressure Model for Precision GPS Orbit Determination

  • Bae, Tae-Suk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.1
    • /
    • pp.55-62
    • /
    • 2017
  • The SRP (Solar Radiation Pressure) model has always been an issue in the dynamic GPS (Global Positioning System) orbit determination. The widely used CODE (Center for Orbit Determination in Europe) model and its variants have nine parameters to estimate the solar radiation pressure from the Sun and to absorb the remaining forces. However, these parameters show a very high correlation with each other and, therefore, only several of them are estimated at most of the IGS (International GNSS Service) analysis centers. In this study, we attempted to numerically verify the correlation between the parameters. For this purpose, a bi-directional, multi-step numerical integrator was developed. The correlation between the SRP parameters was analyzed in terms of post-fit residuals of the orbit. The integrated orbit was fitted to the IGS final orbit as external observations. On top of the parametric analysis of the SRP parameters, we also verified the capabilities of orbit prediction at later time epochs. As a secondary criterion for orbit quality, the positional discontinuity of the daily arcs was also analyzed. The resulting post-fit RMSE (Root-Mean-Squared Error) shows a level of 4.8 mm on average and there is no significant difference between block types. Since the once-per-revolution parameters in the Y-axis are highly correlated with those in the B-axis, the periodic terms in the D- and Y-axis are constrained to zero in order to resolve the correlations. The 6-hr predicted orbit based on the previous day yields about 3 cm or less compared to the IGS final orbit for a week, and reaches up to 6 cm for 24 hours (except for one day). The mean positional discontinuity at the boundary of two 1-day arcs is on the level of 1.4 cm for all non-eclipsing satellites. The developed orbit integrator shows a high performance in statistics of RMSE and positional discontinuity, as well as the separations of the dynamic parameters. In further research, additional verification of the reference frame for the estimated orbit using SLR is necessary to confirm the consistency of the orbit frames.

Development of On-line Sorting System for Detection of Infected Seed Potatoes Using Visible Near-Infrared Transmittance Spectral Technique (가시광 및 근적외선 투과분광법을 이용한 감염 씨감자 온라인 선별시스템 개발)

  • Kim, Dae Yong;Mo, Changyeun;Kang, Jun-Soon;Cho, Byoung-Kwan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.1-11
    • /
    • 2015
  • In this study, an online seed potato sorting system using a visible and near infrared (40 1100 nm) transmittance spectral technique and statistical model was evaluated for the nondestructive determination of infected and sound seed potatoes. Seed potatoes that had been artificially infected with Pectobacterium atrosepticum, which is known to cause a soil borne disease infection, were prepared for the experiments. After acquiring transmittance spectra from sound and infected seed potatoes, a determination algorithm for detecting infected seed potatoes was developed using the partial least square discriminant analysis method. The coefficient of determination($R^2_p$) of the prediction model was 0.943, and the classification accuracy was above 99% (n = 80) for discriminating diseased seed potatoes from sound ones. This online sorting system has good potential for developing a technique to detect agricultural products that are infected and contaminated by pathogens.

Evaluation of Chemical Composition in Reconstituted Tobacco Leaf using Near Infrared Spectroscopy (근적외선 분광분석법을 이용한 판상엽 화학성분 평가)

  • Han, Young-Rim;Han, Jungho;Lee, Ho-Geon;Jeh, Byong-Kwon;Kang, Kwang-Won;Lee, Ki-Yaul;Eo, Seong-Je
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.35 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • Near InfraRed Spectroscopy(NIRS) is a quick and accurate analytical method to measure multiple components in tobacco manufacturing process. This study was carried out to develop calibration equation of near infrared spectroscopy for the prediction of the amount of chemical components and hot water solubles(HWS) of reconstituted tobacco leaf. Calibration samples of reconstituted tobacco leaf were collected from every lot produced during one year. The calibration equation was formulated as modified partial least square regression method (MPLS) by analyzing laboratory actual values and mathematically pre-treated spectra. The accuracy of the acquired equation was confirmed with the standard error of prediction(SEP) of chemical components in reconstituted tobacco leaf samples, indicated as coefficient of determination($R^2$) and prediction error of sample unacquainted, followed by the verification of model equation of laboratory actual values and these predicted results. As a result of monitoring, the standard error of prediction(SEP) were 0.25 % for total sugar, 0.03 % for nicotine, 0.03 % for chlorine, 0.16 % for nitrate, and 0.38 % for hot water solubles. The coefficient of determination($R^2$) were 0.98 for total sugar, 0.97 for nicotine, 0.96 for chlorine, 0.98 for nitrate and 0.92 for hot water solubles. Therefore, the NIRS calibration equation can be applicable and reliable for determination of chemical components of reconstituted tobacco leaf, and NIRS analytical method could be used as a rapid and accurate quality control method.

FAST QUANTITATIVE AND QUALITATIVE ANALYSIS OF PHARMACEUTICAL TABLETS BY NIR

  • Nielsen, Line-Lundsberg;Charlotte Kornbo;Mette Bruhn
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3111-3111
    • /
    • 2001
  • The implementation of NIR and chemometrics in the Pharmaceutical industries is still in strong progress, both regarding qualitative and quantitative applications and beneficial results are seen. Looking at the development so far, NIR will change the pharmaceutical industry even more in the future. This presentation will address the experiences and progress achieved regarding the application and implementation of quantitative methods for determination of content uniformity and assay of tablets with less than 10% w/w of active, using Near Infrared transmittance spectroscopy in combination with PLS. Also qualitative methods for identification of the same tablets by Near Infrared reflectance spectroscopy will be discussed. Four commercial tablet strengths are formulated and produced from two different compositions by direct compression. Three different strengths are dose proportional, i.e. fixed concentration by varying in size. The aim was to replace the conventional primary methods for analysing content uniformity, assay and identification by NIR. Studies were performed on comparing transmittance versus reflectance spectroscopy for both applications on the dose proportional tablets. The model for determination of content uniformity and assay was developed to cover both coated and uncoated tablets, whereas the qualitative model was developed to identify coated tablets only. The impact of the tablet formulation, tablet size and coating, resulted in individual models far each composition The best calibration was achieved using diffuse reflectance for the identification purposes and diffuse transmittance for the quantitative determination of the active content within the tablets. As NIR in combination with other techniques opens up the possibility of total quality management within the production, the transfer of the above-mentioned models from a laboratory based approach to an at-line approach at H.Lundbeck will be addressed too.

  • PDF

Simultaneous Determination of Seven Compounds by HPLC-PDA and Cytotoxicity of Samchulkunbi-tang (삼출건비탕의 HPLC-PDA 동시 분석법 설정 및 세포독성)

  • Seo, Chang-Seob;Lee, Mee-Young;Kim, Jung-Hoon;Lee, Jin-Ah;Shin, Hyeun-Kyoo
    • The Korea Journal of Herbology
    • /
    • v.25 no.3
    • /
    • pp.65-71
    • /
    • 2010
  • Objectives:To develop and validate HPLC-PDA methods for simultaneous determination of seven constituents in Samchulkunbi-tang (SKT). Additionally, we investigated the cytotoxicity against BEAS-2B cell line and splenocytes of SKT. Methods:Reverse-phase chromatography using a Gemini $C_{18}$ column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 230, 254 and 280 nm, were used for quantification of the three marker components of SKT. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. The cytotoxicity of SKT were measured by the CCK-8 assay method. Results:Calibration curves were acquired with $r^2$>0.9999, and the relative standard deviation (RSD) values (%) for intra- and inter-day precision were less than 6.0%. The recovery rate of each compound was in the range of 86.89-109.78%, with an RSD less than 4.0%. The contents of seven compounds in SKT were 1.39-6.84 mg/g. SKT had no cytotoxicity effect at 50-200 ${\mu}g$/mL concentrations. Conclusions:The established method will be helpful to improve quality control and in vitro efficacy study of SKT.

Simultaneous Determination of 11 Marker Compounds in Gumiganghwal-tang by HPLC-DAD and LC-MS

  • Weon, Jin Bae;Jung, Youn Sik;Ryu, Gahee;Yang, Woo Seung;Ma, Choong Je
    • Natural Product Sciences
    • /
    • v.22 no.4
    • /
    • pp.238-245
    • /
    • 2016
  • Gumiganghwal-tang has been used for the treatment of common cold for a long-time. We developed an accurate and sensitive high performance liquid chromatography-diode array detection (HPLC-DAD) and electrospray ionization mass spectrometry method for the simultaneous determination of ferulic acid, baicalin, bergapten, methyl eugenol, glycyrrhizin, oxypeucedanin, wogonin, nodakenin, atractylenolide III, imperatorin, and atractylenolide I in Gumiganghwal-tang samples. The analytes were separated on a Shiseido C18 column ($5{\mu}m$, $4.6mm\;I.D.{\times}250mm$) with gradient elution with acetonitrile and 0.1% trifluoroacetic acid. Eleven compounds were quantitatively determined by HPLC-DAD and identified by LC-MS data. We also validated this method. The calibration curves of all the compounds showed good linear regression. The limits of detection and the limits of quantification ranged from 0.04 to 0.63 and from 0.12 to $1.92{\mu}g/mL$, respectively. The relative standard deviation values of intra- and inter-days of this method represented less than 2.9%. The recoveries were found to be in the range of 90.06 - 107.66%. The developed method has been successfully applied to the analysis of Gumiganghwaltang samples. The established HPLC method could be used to quality control of Gumiganghwal-tang.