• 제목/요약/키워드: Quality Control (QC)

검색결과 178건 처리시간 0.026초

뉴라운드 대비 쌀 생산 기술 전략 (A Strategy on Rice Production of Korea under New round System in WTO)

  • 박광호
    • 현장농수산연구지
    • /
    • 제4권1호
    • /
    • pp.39-44
    • /
    • 2002
  • This paper was studied on a strategy in rice production under New round system of WTO(World Trade Organization) in Korea. Under enactment of New round system in WTO rice will be opened at the world market and thus rice growers will compete with this marketing system. In this regard, rice industry in Korea would be "a theory of rice triangle" such as high quality, low cost, and environmental friendly system. High quality rice would be obtained through a cultivar, cultivation technology, and quality control(QC) to compete against oversea's dealer. Lower cost in rice production should be concentrated into rapid decrease in rural population and into introducing for young generation. Rice cultivation has been played major role in this peninsula in terms of a preservation of water resource, fresh air and prevention of soil erosion.

작업관리기법의 활용실태에 관한 조사연구 (A study on the work study application in industry)

  • 안세희
    • 기술사
    • /
    • 제16권4호
    • /
    • pp.20-31
    • /
    • 1983
  • Study was made for the work study application in industry by sampling one thousand manufacturing companies. Small and medium industries are far behind in systematic application of the work study technique. Large industries are gradually introducing the work study technique systematically in line with the nation-wide quality control movement. Major sessions that the industries feel important in IE curriculum were QC, Work study and Cost accounting followed by the Organization theory, Industrial psychology, and Labor relations. Most of the industries were still less aware of the sophisticated fields such as OR, SE and Simulation. They put more emphasis on QC and TQC and as a result, work study should be closely bounded to TQC in order to systemize the work study application in the future.

  • PDF

대만고속철도 건설사업의 시공자 자체 품질관리시스템 운영에 대한 고찰 (An Investigation on Self Certification System of Contractors in the Taiwan High-Speed Rail Project)

  • 이태식;이동욱;배건;박동찬;김열규;선우강;김영환;김대영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 춘계학술대회 논문집
    • /
    • pp.30-35
    • /
    • 2001
  • THSRC uses the self-certification system for its high-speed rail construction. The self-certification system takes advantages of obtaining good qualify in project and communicating well between contractors and QA/QC organization. But one should understand ISO 9000s and the self-certification system of contractors in advance and contractors try to control Quality of construction spontaneously. Actually, construction progress is slowed down because of increased QA/QC works. For adapting this system in domestic construction, it is need to understand ISO 9000s and the self-certification system.

  • PDF

PM2.5 자동측정장비 비교 및 정도관리 방안 (Comparison of the Real-time Measurements for PM2.5 and Quality Control Method)

  • 박미경;박진수;조미라;이용환;김현재;오준;최진수;안준영;홍유덕
    • 한국대기환경학회지
    • /
    • 제33권6호
    • /
    • pp.616-625
    • /
    • 2017
  • Measurements using five real-time particle samplers were compared to measurements using three NRM (National Reference Method system) filter-based samplers(Gravimetric method) at Incheon, Korea, between May and August, 2014. The purpose of this study was to suggest the quality assurance/quality control (QA/QC) method of each instrument for use in a real-time continuous particle sampler to measure the mass of airborne particles with an aerodynamic diameter less than $2.5{\mu}m$ ($PM_{2.5}$). Five real-time particle samplers of BAM1020, FH62C_14, TEOM, PM-711 and SPM-613 were evaluated by comparing its measured 23 hr average $PM_{2.5}$ concentrations with those measured with NRM filter-based samplers simultaneously. The parameters(e.g. Inlet heating condition, Slope factor, Film response, Intercept, Background, Span value) of the real-time samplers were optimized respectively by conducting test performance evaluation during 7 days in field sampling. For example, inlet heating temperature of TEOM sampler controls $35{\sim}40^{\circ}C$ to minimize the fluctuation of the real-time measurement data and background value of BAM1020 is the key factor affecting the accuracy of $PM_{2.5}$ mass concentration. We classified the $PM_{2.5}$ concentration according to relative humidity (80%) to identify water absorbed in aerosols by measuring the ${\beta}$-ray samplers(BAM1020, FH62C_14) and TEOM. ${\beta}$-ray samplers were not strongly affected by relative humidity that the difference of the average $PM_{2.5}$ concentration was about 5%. On the other hand, The TEOM sampler overestimated $PM_{2.5}$ mass concentration about 15% at low relative humidity (<80%).

Control Parameter를 이용한 GPS 관측데이터의 품질 관리 (GPS Observation Data Quality Control using Control Parameters)

  • 이동하;윤홍식;이영균
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2004년도 추계학술발표회 논문집
    • /
    • pp.87-93
    • /
    • 2004
  • 본 연구에서는 효율적인 GPS 데이터의 품질관리를 위한 GPS_QC 프로그램을 개발하여, GPS 데이터의 Quality 판단할 수 있는 총 8개의 Control 인자(위성의 배치, Multipath 오차량, 전리층 지연량 및 위성신호 강도 등)를 계산 할 수 있었으며, GPS 데이터 품질에 관련된 Control 인자의 결과값 및 허용오차 범위, 실제 관측데이터의 허용오차의 포함여부를 시계열 그래프와 보고서 형태로 제공하여 현장 등에서 간단하고 효율적으로 GPS 데이터의 품질관리를 가능하게 한다. 따라서 기존에 GPS 데이터 해석 후에나 판단이 가능했던 데이터의 품질을 현장이나 실내에서 직접 확인할 수 있게 함으로서 재측과 데이터 처리 시 소요되는 시간과 경비를 절감할 수 있을 것으로 판단된다.

  • PDF

복합 처방 품질 관리를 위한 시스템 차원의 연구 동향 (Trends in System-level Research on Quality Control of Complex Herbal Formulation)

  • 이두석;김영우
    • 동의생리병리학회지
    • /
    • 제30권6호
    • /
    • pp.397-401
    • /
    • 2016
  • The quality control is a fundamental procedure for the standardization of herbal medicine to guarantee the consistency of efficacy and safety. For a long time, the quality analysis of herbal medicine has been largely dependent on the routine sensory evaluation, such as taste, smell, color, and shape. However, with the recent development of analytical instruments, various scientific approaches have been introduced in this field. On the basis of the theory that the biological activities of herbal medicine are mainly contributed by its chemical compositions, several types of chemical markers have been suggested for the quality evaluation. In addition to the analytical methods for the specific marker compound(s), including analytical marker and active marker, recently, chemical fingerprinting, a method comparing the chromatographic pattern of the whole chemical components, has been developed and widely accepted as a reliable approach for the quality control of herbal medicine. Moreover, in order to exactly understand the relationship between complex compounds and their holistic biological activities in herbal medicine, unique strategies, such as "BECCs (bioactive equivalent combinatorial components)" and "PhytomicsQC" have been established. In this article, we give an overview of the several categories of chemical markers and the recent research trends for the quality evaluation of herbal medicine.

융복합 시대의 국가 SW R&D 프로젝트에 대한 품질활동관리 적정성 평가 방안 연구 (A study of appropriateness evaluation method for quality activity management of Software R&D Project)

  • 서영욱;채성욱
    • 디지털융복합연구
    • /
    • 제13권8호
    • /
    • pp.91-99
    • /
    • 2015
  • 최근에 소프트웨어(SW) 융복합 시대를 맞아 SW품질관리의 중요성에 대한 관심이 높아지고 있다. 이에 본 연구에서는 품질관리전담기관의 SW품질활동관리 적정성을 객관적으로 평가 할 수 있는 방안에 대하여 기존의 품질 활동관리 적정성 사례를 기반으로 새로운 적정성 평가 방안을 제안하고자 한다. 이를 위하여 다음과 같이 연구 목적을 세 가지로 설정한다. 첫째, 기존의 국가 SW R&D 프로젝트의 SW품질활동관리 적정성 평가의 문제점을 도출하고 분석한다. 둘째, 기존의 SW품질활동관리 적정성 평가에 대한 문제점을 극복할 수 있는 새로운 적정성 평가 방법을 제안한다. 셋째, 새로운 적정성 평가 방법을 WBS(World Best Software) 프로젝트를 대상으로 적용해서 그 가능성과 효과성에 대하여 살펴본다. 본 연구에서 새롭게 제시한 국가 SW R&D 품질활동관리 적정성 평가 프레임워크를 대형 SW R&D 프로젝트인 WBS 프로젝트의 2개 과제에 실질적으로 적용해봄으로써 새로운 품질활동관리 적정성 평가 프레임워크의 효과성과 실무 적용 가능성을 입증하였다.

교량 점검신뢰도 분석법 개발과 향상방안 (Development of Bridge Inspection Reliability and Improvement Strategy)

  • 정유석;김우석;이일근;이재하
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권5호
    • /
    • pp.50-57
    • /
    • 2016
  • 교량의 안전은 점검에 의해 보장된다. 그리고 교량의 유지관리는 점검결과를 토대로 시작된다. 따라서 점검결과는 '교량의 안전'과 '효율적인 유지관리'를 위한 가장 중요한 정보이다. 따라서 본 논문에서는 교량의 점검신뢰도를 평가하고 이를 제고 할 수 있는 방안을 제시하고자 한다. 이를 위해 본 논문에서는 교량의 점검신뢰도를 평가 할 수 있는 세 가지 점검신뢰도를 제시하였다: 명목점검신뢰도, 실질점검신뢰도, DS명목점검신뢰도. 교량의 점검신뢰도 분석 방법은 정밀안전진단결과를 참값으로 간주하고 당해년도 정밀(정기)점검과 차년도 정밀안전 진단결과를 비교하였다. 인적오류를 고려한 DS명목신뢰도를 기준으로 현재 고속도로교량의 점검신뢰도 85%로 양호한 편으로 평가 된다. 이는 현재 고속도로 교량의 평균공용연수가 13년으로 대부분의 교량이 'A'와 'B'등급에 집중적으로 분포되어 상태변화가 크지 않기 때문인 것으로 판단된다. 점검신뢰도를 제고하기 위해서는 점검자의 역량을 강화하고 전문점검인력 육성이 필요하며 점검결과에 대해 QC(Quality Control, 품질관리)를 실시하여 점검결과의 신뢰도 향상이 필요하다.

감도분석에 의한 제조공정연구 (A Study on the manufacturing process using the sensitivity analysis of stochastic network)

  • 박기주
    • 산업경영시스템학회지
    • /
    • 제24권63호
    • /
    • pp.65-77
    • /
    • 2001
  • A more technical perspective is needed in estimating the effect of the Manufacturing Process for improving the Productivity, there are many statistical evaluation methods, convenience sampling, frequencies, histogram, QC seven tools, control chart etc. It is more important for the companies to use six sigma to reduce defective and improve the process control than the technical definition as a disciplined quantitative approach for improvement of process control and a new way of quality innovation. Process network analysis is a technique which has the potentiality for a wide use to improve the manufacturing process which other techniques can't be used to analyze effectively. It has some problems to analyze the process with feedback loops. The branch probabilities during quality inspections depend upon the number of times the product has been rejected. This paper presents how to improve the manufacturing process by statistical process control using branch probabilities, Moment Generating Function(MGF) and Sensitivity Equation.

  • PDF

GC/MS를 이용한 모발 중 메스암페타민 및 암페타민 분석의 측정불확도 평가 (Uncertainty Evaluation of the Analysis of Methamphetamine and Amphetamine in Human Hair by GC/MS)

  • 김진영;김종상;김민경;이재일;서용준;인문교
    • 약학회지
    • /
    • 제51권3호
    • /
    • pp.206-213
    • /
    • 2007
  • Recently estimating the uncertainty of an analytical result has become an essential part of quantitative analysis. This study describes the uncertainty of the measurement for the determination of methamphetamine and its major metabolite amphetamine in human hair, The method consists of washing, drying, weighing, incubation and extraction with methanolic HCI solution, clean-up, trifluoroacetyl derivatization, and qualification/quantification of residues by gas chromatography/mass spectrometry (GC/MS). Traceability of measurement was established through traceable standards and calibrated volumetric equipment and measuring instruments. Measurement uncertainty associated with each analyte in real samples was estimated using quality control (QC) data. The main source of combined standard uncertainty comprised two components, which are uncertainties associated with calibration linearity and variations in QC, while those associated with preparation of analytical standards and sample weighing were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method ranged for individual analytes from 4.99 to5.03%.