• 제목/요약/키워드: Quality Control (QC)

검색결과 179건 처리시간 0.03초

Taguchi Method의 On-Line Quality control에 있어서 관리한계 및 검사간격 결정에 대한 연구 (The Determination of Control Limit and Testing Interval in the On-Line Quality Control of Taguchi Method)

  • 김욱일;강창욱
    • 품질경영학회지
    • /
    • 제20권2호
    • /
    • pp.11-20
    • /
    • 1992
  • We discuss the feed back control of the on-line QC in the Taguchi method. Taguchi(1982) used the assumptions that the quality characteristics follow an uniform distribution and the Brownian motion to draw the loss function and proposed ${\Delta}/3$ or ${\Delta}$ for the initial control limit. Adams and Woodall(1989) also proposed a different procedure but using the same loss function. We propose, in this paper the new loss function under the assumption of mainly Brownian motion and compare the results with the results of the above.

  • PDF

해양환경 정도관리제도 운영에 대한 고찰 (The History and Development of the Marine Environment QA/QC (Quality Assurance/Quality Control) Management System)

  • 박미옥;박준건;김성길;김성수
    • 한국해양학회지:바다
    • /
    • 제26권3호
    • /
    • pp.185-200
    • /
    • 2021
  • 해양환경 정도관리제도는 자료의 신뢰성 확보와 측정·분석기관의 분석능력 향상을 위해 2010년부터 본격적으로 시행되었다. 시행부터 2020년까지 측정·분석기관이 정도관리제도에 참여한 누적 건수는 총 266건, 해양수산부에서 인증서를 발급한 건수는 182건, 현재까지 유효한 인증서는 42건이다. 정도관리 숙련도 평가를 위한 표준물질은 3개 분야에서 32항목이 개발되었으며, 해양환경측정망 운영, 해양오염영향조사, 해역이용영향평가, 해양심층수조사 및 어장환경조사 사업 등에서 주로 분석하는 영양염, 화학적산소요구량, 미량금속 등의 항목을 중심으로 개발되었다. 반면, 대부분의 사업에서 분석하는 해수의 수온, 염분 및 해저퇴적물의 PCBs, PAHs 등은 정도관리가 시행되고 있지 않아서 이 항목들에 대한 정도관리 확대가 필요한 시점이다. 현장 평가는 ISO/IEC 17025에 의해 평가 받은 실험실(162건)을 대상으로 품질시스템 평가 및 미흡사항을 분석하였다. 경영 및 기술요건에서는 직원들의 업무분장 미흡이 약 4.2%, 직원 교육 미흡이 약 8.7%로 취약하게 나타났다. 시험분야별로는 표준물질관리 미흡이 약 6.3%, 초자기구 세척 상태 등이 약 5.4%로 지적되었다. 미흡한 부분에 대한 문제점 및 개선점을 파악하여 제도를 지속적으로 보완해 나가야 할 것이다.

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • 통합자연과학논문집
    • /
    • 제8권2호
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.

실리콘 단결정 잉곳 제조용 석영유리 도가니 내 기포 품질평가를 위한 가속시험 (Accelerated testing for evaluating bubble quality within quartz glass crucibles used for manufacturing silicon single crystal ingots)

  • 이규빈;강승민;최재호;변영민;김형준
    • 한국결정성장학회지
    • /
    • 제33권3호
    • /
    • pp.91-96
    • /
    • 2023
  • 석영유리 도가니(QC)의 사용 중 기포 품질을 검증하기 위하여 적절한 가속 시험 방법을 제안하였다. 실제 Czochralski(Cz) 공정에서 얻어진 폐기물 도가니의 기포 상태를 분석하고 QC 시험편을 이용하여 온도, 압력, 시간을 변화시켜 최적의 열처리 조건을 제시하였다. Cz 공정에서 생성되는 유사한 기포 크기와 밀도로 제어하기 위해서는 1450℃, 0.4 Torr 및 40시간의 열처리 조건이 적절하였다. 특히 Cz 공정에서 적용하는 압력인 10~20 Torr보다 상대적으로 낮은 압력인 0.4 Torr를 선택함으로써 기포 형성 가속시험의 시간을 단축시킬 수 있었다. 열처리 온도를 1550℃ 높일 경우, Ostwald ripening 현상으로 인하여 기포가 커지고 밀도가 급격히 낮아지며, 결정화 발생으로 적절한 가속시험 조건은 아닌 것으로 판단하였다.

침대 광고에 표현된 품질관리 요소에 대한 연구 (A Study on Quality Control which is Expressed in Advertisement of Residential Beds)

  • 임광순;김종국;최준오
    • 한국가구학회지
    • /
    • 제25권3호
    • /
    • pp.213-224
    • /
    • 2014
  • Advertising provides consumers with information about products, purchasing effect and criteria. Advertising of the domestic bed companies started in the 1990's and each company focused on publicizing its brand. As the times change, however, they begin to express the quality-property which consumers demanded in the advertising. This research examined the advertising trends in the domestic and foreign bed companies. Also, it presents how the quality control (QC) is reflected on the advertising of the domestic and foreign bed companies. As a result of the analysis on bed-advertising of them, the things mostly represented as a determinant of product quality are performance, shape/quality, recognition and reliability. On the side of consumers, however, service, durability and stability are mirrored in the advertising and help choose the products as the determinants.

  • PDF

사이버나이프의 품질관리 절차서 개발 (The Development of Quality Assurance Program for CyberKnife)

  • 장지선;강영남;신동오;김문찬;윤세철;최일봉;김미숙;조철구;류성렬;권수일;이동한
    • Radiation Oncology Journal
    • /
    • 제24권3호
    • /
    • pp.185-191
    • /
    • 2006
  • 목 적: 국내 실정에 적합한 사이버나이프의 표준화된 품질관리 절차서가 없어 이를 개발하고 유용성을 평가하고자 한다. 대상 및 방법: 사이버나이프의 구조적 특성과 치료 방법 등을 고려하여 품질관리 검사항목을 설정한 후, 적합한 시행 시기에 맞추어 주기적 분류를 하였다. 그리고 설정된 항목들은 각각의 품질관리 목적에 따라 일반적인 품질관리(basic QC), 치료정확도 품질관리(delivery specific QC), 환자 맞춤형 품질관리(patient specific QC) 등 3개의 분야로 구분하였다. 국내의 두 개 기관을 대상으로 개발된 품질관리 절차서의 각 항목을 비교하여 허용오차를 분석하였다. 설정된 항목에 대한 허용 오차는 제작사에서 제공된 품질관리 자료와 현재 국내에 설치되어 있는 두 개 기관의 최근 3년간의 품질관리 수행 데이터 등을 근거하였으며, 각 항목에 대한 측정 결과를 토대로 품질관리 실태를 분석하고 개발된 품질관리 절차서의 타당성을 검증하였다. 결 과: 개발된 사이버나이프 품질관리 절차서의 항목에 대하여 두 개 기관을 대상으로 정확성을 상호 비교 분석하였다. 모든 측정 결과는 사이버나이프의 품질관리 절차서에서 제시한 허용오차 범위 내에서 일치하고 있음을 확인하였다. 결 론: 본 연구에서 개발된 품질관리 절차서를 통해 사이버나이프에 대한 성능평가 기준을 확립할 수 있으며, 영상유도 정위방사선치료에 대한 정확성 및 안전성을 확보할 수 있을 것으로 생각된다.

의료분야 진단용방사선발생장치의 품질관리 (Quality Control of Diagnostic X-ray Equipment in Medical Field)

  • 조평곤
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.159-164
    • /
    • 2021
  • 진단용방사선발생장치를 이용한 검사는 영상의학과에서 인체 내 정보를 파악하기 위한 가장 유용한 진단장비 중 하나로 신뢰도가 매우 높다. 이와 같은 이유로, 최근에는 영상의학과 영역의 진단 검사 장비를 이용한 검사 건수가 매년 증가하고 있다. 또한, 검사 건수 증가는 장치의 빠른 노화를 불러일으키고 이로 인해 장치에 대한 정도관리(quality control, QC)의 중요성이 대두된다. 특히, 진단용방사선발생장치를 이용한 검사에서 정도관리란 검사시작부터 검사가 끝날 때 까지 발생할 수 있는 모든 문제점을 사전에 알아내고 대처하여 신뢰가 확보된 영상을 획득하여 제공하는 과정에 있는 일련의 모든 활동을 의미한다. 이에 본 연구에서는 진단용방사선발생장치를 이용한 검사에서 정도관리에 대해보고 한다.

울릉도 온실기체 관측자료를 이용한 배경대기 평균농도 산정 (An Estimation of Mean Background Concentrations of Greenhouse Gases Observed on Ulleungdo)

  • 임윤규;문윤섭;김진석;송상근;홍지형
    • 한국지구과학회지
    • /
    • 제33권1호
    • /
    • pp.32-38
    • /
    • 2012
  • 본 연구에서는 울릉도 온실기체 관측장비(CRDS)에서 관측된 $CO_2$$CH_4$ 농도를 정형화된 QA${\cdot}$QC 처리절차를 통해 온실기체 평균 배경대기 농도값으로 활용하기 위한 정확도를 향상시켰다. QA${\cdot}$QC 처리절차는 총 3단계로 구성되었다. 첫 번째는 관측자료의 시간별 평균값을 구하기 위한 물리적 한계검사, 기후범위 검사 및 1시간 측정 자료수가 50% 이하인 자료는 제외시키는 과정으로 이루어져 있다. 두 번째는 일평균자료 산출을 위한 단계검사, 앞뒤로 같은 값일 경우는 제외, 하루 중 관측횟수가 15회 이상 및 일관측 자료의 표준편차가 일표준편차 평균의 3배 이하인 자료만 허용하는 과정이다. 세 번째는 기후적 특성분석 활용을 위한 Curve-fitting methods를 이용한 FFT 적용단계이다. 이상의 QA${\cdot}$QC 절차에 의한 $CO_2$$CH_4$의 월평균농도 값을 안면도 지구대기감시센터 자료와 일본 료리 관측자료와 비교 분석한 결과 $CO_2$에 있어서는 울릉도 관측자료 누락에 의한 영향이 다소 크게 나타나 안면도 관측값이 배경대기 평균농도 값으로 유효하였고, $CH_4$는 안면도 보다 오히려 울릉도 관측값이 한반도 배경대기 평균농도 값으로 더 적절한 것으로 추정되었다.

CPT를 이용한 준설매립지반의 개량효과 평가에 관한 연구 (A Study on the Ground Improvement Effective Evaluation of Reclaimed Land Using Cone Penetration Test)

  • 김종국;채영수;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.910-921
    • /
    • 2004
  • In this study, the pilot tests on the reclaimed land were performed in order to find the suitable construction method with dynamic compaction Type I, Type II at different dynamic energy and hydraulic hammer compaction. The estimation of the compaction through the various pilot tests was performed by the CPT-qc, SPT-N and field density tests. As the result of the pilot tests, it shows that the dynamic compaction method is better than the hydraulic hammer compaction method in the effect of the ground improvement, especially dynamic compaction Type I is much superior to others. When it comes to method for measuring the intensity of the ground, the value of the cone penetration test-resistance(qc) is much suitable for the ground. Besides, the standards for the compaction control, which showed that over 10Mpa at 0 through 5meters in the upper layer and 7Mpa at 5 through 8meters in the lower layer in the CPT-qc, could be found without discrimination of the upper road and lower road on the reclaimed land. And it also found that the intensity of the reclaimed land gets back to the original status in about 10 through 15 days.