• Title/Summary/Keyword: Quality Control (QC)

Search Result 176, Processing Time 0.027 seconds

Development and Validation of Crocidolite Quality Control Samples for Proficiency Analytical Testing (청석면 분석 정도관리용 표준시료 개발 및 평가)

  • Lee, Ji-Hyun;Kim, Eun-Young;Noh, Su-Jin;Park, Yong-Jin;Jeong, Jee-Yeon
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.1
    • /
    • pp.57-63
    • /
    • 2011
  • Crocidolite quality control (QC) sampling created by the wet generation method has been validated by validation tests such as the accuracy, precision, and storage tests. For this study we designed and developed a manufacturing apparatus and standard operating procedure for making these QC samples. The most important step in the procedure of making QC samples was the stage eliminating static electricity in asbestos fibers. This static electricity hampers the fibers clog functioning. In accuracy and precision tests by phase contrast microscopy analysis, the difference between the reference values and the studied values was at maximum 17.8%. This satisfies the AIHA proficiency analytical test criteria for asbestos. We could confirm the nearly even distribution of crocidolite fibers on the membrane filter. Also, there was no loss of fibers in the storage test after the one month.

Survey of Current Status of Quality Control of Gamma Cameras in Republic of Korea (감마카메라 정도관리 실태 조사)

  • Choe, Jae-Gol;Joh, Cheol-Woo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.314-322
    • /
    • 2008
  • Purpose: It is widely recognized that good quality control (QC) program is essential for adequate imaging diagnosis using gamma camera. The purpose of this study is to survey the current status of QC of gamma cameras in Republic of Korea for implementing appropriate nationwide quality control guidelines and programs. Methods: A collection of data is done for personnel, equipment and appropriateness of each nuclear medicine imaging laboratory's quality control practice. This survey is done by collection of formatted questionnaire by mails, emails or interviews. We also reviewed the current recommendations concerning quality assurance by international societies. Results: This survey revealed that practice of quality control is irregular and not satisfactory. The irregularity of the QC practice seems due partly to the lack of trained personnel, equipment, budget, time and hand-on guidelines. Conclusion: The implementation of QC program may cause additional burden to the hospitals, patients and nuclear medicine laboratories. However, the benefit of a good QC program is obvious that the hospitals can provide good quality nuclear medicine imaging studies to the patients. It is important to use least cumbersome QC protocol, to educate the nuclear medicine and hospital administrative personnel concerning QC, and to establish national QC guidelines to help each individual nuclear medicine laboratory.

Evaluation of quality control, DIACON (DIACON 정도관리물질의 평가)

  • Kim, Byung Chan;Jung, Chang Gi;Kim, Sang Su;Park, Hae Mi;Kim, Ji Sun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.44-50
    • /
    • 2015
  • Purpose Quality control used in laboratory help to sustain precision and accuracy consistently to ensure the Diagnostic and treatment for medical employee. To perform an evaluation in statistical manner, it is recommended to use different quality control material than calibrator from manufacturer, quality control material must include analyzed concentration perimeter, must use more than two different concentration materials and recommended to use materials to indicate the concentration in clinical use. However, currently used quality control material has limit of evaluation due to unconsidered concentration or improperly used to get clinical importance data. Therefore, we compared the value of quality control, DIACON Hormone Level 1, 2, 3 (Scantibodies, USA) and DIACON Tumor Level 1, 2, 3 which applied to clinical concentration range. Materials and Methods DIACON Hormone Level 1, 2, 3 (Scantibodies, USA) and DIACON Tumor Level 1, 2, 3 (Scantibodies, USA) that used materials and methods test to compare the result from five RIA testing institution and one institution that used Elecsys (ROCHE) and Architect (ABOTT) for each level. The reagent RIA kit that used in this experiment is followed by Table 2 and 3. Test has performed by instruction itself and follow by instruction. Results Among DIACON hormone result of twenty four items, level 1 have three items, level 2 have four items and level 3 have five items were out of manufacturer set up range based on the average value. Among DIACON tumor result of thirteen items, level 1 have three items, level 2 have four items and level 3 have five items were out of manufacturer set up range. Other result were inside of manufacturer range. Conclusion For quality control material, it is widely available in market, but it is limited for normal range which is only concerned in improper clinical value and difficult to evaluate important concentration area in terms of clinical analyze. In this experiment, we evaluate Hormone twenty three items and Tumor thirteen items with DIACON Hormone and Tumor (Scantibodies, USA) to resolve this limit and we could observe that it ca be substituted and used.

  • PDF

Use of Statistical Process Control for Quality Assurance in Radiation Therapy (방사선치료에서의 품질보증을 위한 통계적공정관리의 활용)

  • Cheong, Kwang-Ho
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.59-71
    • /
    • 2015
  • The goal of quality assurance (QA) is to minimize systematic errors in order to maintain the quality of a certain process. Statistical process control (SPC) has been utilized for QA in radiation therapy field since 2005 and is changing QA paradigm. Its purpose is to maintain a process within the given control limits while monitoring of error trends such as variation or dispersion. SPC can be applied to all QA aspects of radiotherapy; however, a medical physicist should have enough knowledge about the application of SPC to QC/QA procedures. In this paper, the author introduce a concept of SPC and review some previously reported studies those used SPC for QA in radiation therapy.

Relative performance of group CUSUM charts

  • Choi, Sungwoon;Lee, Sanghoon
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.11-14
    • /
    • 1996
  • Performance of the group cumulative sum(CUSUM) control scheme using multiple univariate CUSUM charts is more sensitive to the change of quality control(QC) characteristics than the control chart scheme based on the Hotelling statistics. We examine three group charts for multivariate normal data sets simulated with various correlation structures and shift directions in the mean vector. These group schemes apply the orginal measurement vectors, the scaled residual vectors from the regression of each variable on all others and the principal component vectors respectively to calculating the CUSUM statistics. They are also compared to the multivariate QC charts based on the Hotelling statistic by estimating average run lengths, coefficients of variation of run length and ranks in signaling order. On the basis of simulation results, we suggest a control chart scheme appropriate for specific quality control environment.

  • PDF

RELATIVE PERFORMANCE COMPARISON OF GROUP CUSUM CHARTS

  • Choi, Sung-Woon;Lee, Sang-Hoon
    • Management Science and Financial Engineering
    • /
    • v.5 no.1
    • /
    • pp.51-71
    • /
    • 1999
  • Performance of the group cumulative sum (CUSUM) control scheme using multiple univariate CUSUM charts is more sensitive to the change of quality control (QC) characteristics than the control chart schemes based on the Hotelling statistic We vexamine three group charts for multivariate normal data sets simulated with various correlation structures and shift directions in the mean vector. These group schemes apply the original measurement vectors, the scaled residual vectors from the re-gression of each variable on all others and the principal component vectors respectively to calculat-ing the CUSUM statistics. They are also compared to the multivariate QC charts based on the Ho-telling statistic by estimating average run lengths, coefficients of variation of run length and ranks in signaling order. On the basis of simulation results, we suggest a control chart scheme appropriate for specific quality control environment.

  • PDF

A Study on QA/QC Method for GHG Inventory in the Railroad Construction Sector (철도건설현장의 온실가스 인벤토리 QA/QC 방안 연구)

  • Lee, Jae-Young;Jung, Woo-Sung;Kim, Yong-Ki;Hwang, In-Hawn
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.511-514
    • /
    • 2011
  • The impact of greenhouse gas (GHG) emissions is the global issue over the world. Korean government has presented various policies to induce GHG reduction for the industries with high energy consumption such as power generation and chemistry. Construction sector has produced a large amount of GHG emissions resulted in the energy consumption of heavy equipments and the use of materials. This study aims to suggest the QA (Quality Assurance) and QC (Quality Control) method to identify and quantify the GHG emissions released from heavy equipments in the railroad construction sector. Generally, the accuracy and reliability of GHG inventory is dependent on the data collection. Therefore, it is necessary to mange the detailed statements for the fuel consumption of heavy equipments and the quantity of work in the field. Also, the breakdown of GHG emission sources should be recorded from the design step of railroad infrastructures. Based on these data, the GHG reduction technologies and polices can be applied in railroad construction sector.

  • PDF

A Study on Quality Improvement of Medical Equipments (의료기기 QI 활동 개선방안에 대한 연구)

  • Kang, Hun-Hee;Juh, Ra-Hyeong;Kim, Jong-Soon;Kim, Seo-Hwak;Huh, Soo-Jin
    • Quality Improvement in Health Care
    • /
    • v.5 no.2
    • /
    • pp.190-201
    • /
    • 1998
  • Background : Medical equipments take a very important role in diagnosis and treatment of disease in modern medicine and effective maintenance of the equipments is a necessary to provide a good health care to the public. After developing a new QC program for effective maintenance of medical equipments and practicing it for a year, we report the results of the new program. Methods : The maintenance data of 9 equipments in 8 categories including a CT Scanner were analyzed with regard to the parts responsible for most frequent failure and cause of the failure. After learning the most frequent failure part and cause of the failure, we developed a new QC program that emphasizes preventive maintenance of the most frequent failure part. We compared the number of failure per year and active rate of each equipment before and after the adoption of the new QC program. Results : The average number of failure per year per equipment was 20.7 before and it decreased by 43% to 11.9 after adoption of the new QC program. The average active rate of the equipments was 92.6% before and it increased by 3.2% to 95.8% after adoption of the new program. Conclusions : The practice of the new QC program appears very useful as it decreased the failure rate and increased the active rate of the equipments.

  • PDF

QA/QC Techniques for the Automated Hydrocarbon Monitoring Natwork in the UK

  • Rod Robinson;Tony andrews;David Butterfield;Paul Quincey
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E1
    • /
    • pp.25-33
    • /
    • 2001
  • This paper presents an overview of the UK Hydrocarbon Monitoring Network and summarises some of the lessons learnt from running and automated VOC monitoring network in th UK. The paper will describe the operation of the network and the Quality Control and Quality Assurance (QA/QC) procedures used to ensure that the data qality objectives are met. The provision of accurate measurements of ambient air pollutant concentrations is a valuable and high-profile service of Governments, assisting policy decisions and allowing members of the public to be well-informed. The need for such measurements has been increased in the UK by the National Air Quality Strategy and European Air Quality Directives, with the National Networks playing a central role in delivering the information. The Hydrocarbon Network provides measurements directly in support of monitoring requirements for benzene and 1,3-butadiene, and of 23 other hydrocarbon species important for their role in ozone and secondary particulate formation.

TQC 추진(推進)의 문제점(問題点)과 그 개선(改善) 방향(方向)

  • Kim, Jae-Yong
    • Journal of Korean Society for Quality Management
    • /
    • v.8 no.1
    • /
    • pp.25-31
    • /
    • 1980
  • This paper describes the role of TQC and its present issues as a management tool, especially in regard of Korean firm's environment. The author, participating in TQC activity for himself, stresses that the introduction and driving programs of TQC activity must include such plans as policy control, reorganization, training, standardization, quality assurance, QC circle activity, office management and auditing. The keypoints and problems in performing these plans are reviewed. And as the future hopeful direction of TQC activity, he remarks that a true recognition of quality control as a management tool in "total" concept and the adoption of industry - wide quality control policy.

  • PDF