• Title/Summary/Keyword: Quality Assurance protocol

Search Result 35, Processing Time 0.024 seconds

Quality Assurance of Leaf Speed for Dynamic Multileaf Collimator (MLC) Using Dynalog Files (Dynalog file을 이용한 동적다엽조준기의 Leaf 속도 정도관리 평가)

  • Kim, Joo Seob;Ahn, Woo Sang;Lee, Woo Suk;Park, Sung Ho;Choi, Wonsik;Shin, Seong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.305-312
    • /
    • 2014
  • Purpose : The purpose of this study is to analyze the mechanical and leaf speed accuracy of the dynamic multileaf collimator (DMLC) and determine the appropriate period of quality assurance (QA). Materials and Methods : The quality assurance of the DMLC equipped with Millennium 120 leaves has been performed total 92 times from January 2012 to June 2014. The the accuracy of leaf position and isocenter coincidence for MLC were checked using the graph paper and Gafchromic EBT film, respectively. The stability of leaf speed was verified using a test file requiring the leaves to reach maximum leaf speed during the gantry rotation. At the end of every leaf speed QA, dynamic dynalog files created by MLC controller were analyzed using dynalog file viewer software. This file concludes the information about the planned versus actual position for all leaves and provides error RMS (root-mean square) for individual leaf deviations and error histogram for all leaf deviations. In this study, the data obtained from the leaf speed QA were used to screen the performance degradation of leaf speed and determine the need for motor replacement. Results : The leaf position accuracy and isocenteric coincidence of MLC was observed within a tolerance range recommanded from TG-142 reports. Total number of motor replacement were 56 motors over whole QA period. For all motors replaced from QA, gradually increased patterns of error RMS values were much more than suddenly increased patterns of error RMS values. Average error RMS values of gradually and suddenly increased patterns were 0.298 cm and 0.273 cm, respectively. However, The average error RMS values were within 0.35 cm recommended by the vendor, motors were replaced according to the criteria of no counts with misplacement > 1 cm. On average, motor replacement for gradually increased patterns of error RMS values 22 days. 28 motors were replaced regardless of the leaf speed QA. Conclusion : This study performed the periodic MLC QA for analyzing the mechanical and leaf speed accuracy of the dynamic multileaf collimator (DMLC). The leaf position accuracy and isocenteric coincidence showed whthin of MLC evaluation is observed within the tolerance value recommanded by TG-142 report. Based on the result obtained from leaf speed QA, we have concluded that QA protocol of leaf speed for DMLC was performed at least bimonthly in order to screen the performance of leaf speed. The periodic QA protocol can help to ensure for delivering accurate IMRT treatment to patients maintaining the performance of leaf speed.

GLP-Application to Cell Culture-Based Toxicity Tests

  • Koh, Woo-Suk
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.95-101
    • /
    • 2006
  • Compare to the toxicity tests using experimental animals, the GLP application and compliance in toxicity studies using cell culture systems may be less straightforward elucidated in the two documents published by the OECD Working Croup on GLP 'The Application of the GLP Principles to Short Term Studies (1999)' and 'The Application of the Principles of GLP to in vitro Studies (2004)' The object of this presentation is to show how to interpret the GLP principles and to apply with actual performances in a well known toxicity test using cell culture, chromosome aberration study. The presentation will cover test substance, test system (cell line), study environment management, documentation, quality assurance, and study protocol and report.

  • PDF

Case Study on the Void Characteristics of Concrete Bridge Decks on the Expressway (공용중인 교량 바닥판의 내구성에 공극특성이 미치는 영향)

  • Suh, Jin-Won;Rhee, Ji-Young;Kim, Hong-Sam;Lee, Byeong-Ju;Shin, Do-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.425-428
    • /
    • 2008
  • Concrete bridge decks, as well as asphalt pavement, are directly exposed to traffic loads and environmental conditions like rain water and deiceing chemicals. In this reason, there are often observed the deteriorations of asphalt overlay and of concrete deck under pavement. In this reason, it is important to identify the clear cause of concrete quality from a practical point of view. Therefore, in this paper it was initiated to ultimately suggest a protocol offering guidance as to assurance the quality control of concrete bridge deck on the part of void characteristics of concrete. Examinations such as visual inspection, deteriorated depth, and various void characteristic performed from cored specimens of 19 concrete bridge decks of various local conditions on the expressway. This paper discuss that the bridge deck condition analyses from the testing results were compared to a foreign guide line.

  • PDF

Application of a newly developed software program for image quality assessment in cone-beam computed tomography

  • de Oliveira, Marcus Vinicius Linhares;Santos, Antonio Carvalho;Paulo, Graciano;Campos, Paulo Sergio Flores;Santos, Joana
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.75-86
    • /
    • 2017
  • Purpose: The purpose of this study was to apply a newly developed free software program, at low cost and with minimal time, to evaluate the quality of dental and maxillofacial cone-beam computed tomography (CBCT) images. Materials and Methods: A polymethyl methacrylate (PMMA) phantom, CQP-IFBA, was scanned in 3 CBCT units with 7 protocols. A macro program was developed, using the free software ImageJ, to automatically evaluate the image quality parameters. The image quality evaluation was based on 8 parameters: uniformity, the signal-to-noise ratio (SNR), noise, the contrast-to-noise ratio (CNR), spatial resolution, the artifact index, geometric accuracy, and low-contrast resolution. Results: The image uniformity and noise depended on the protocol that was applied. Regarding the CNR, high-density structures were more sensitive to the effect of scanning parameters. There were no significant differences between SNR and CNR in centered and peripheral objects. The geometric accuracy assessment showed that all the distance measurements were lower than the real values. Low-contrast resolution was influenced by the scanning parameters, and the 1-mm rod present in the phantom was not depicted in any of the 3 CBCT units. Smaller voxel sizes presented higher spatial resolution. There were no significant differences among the protocols regarding artifact presence. Conclusion: This software package provided a fast, low-cost, and feasible method for the evaluation of image quality parameters in CBCT.

Quality assurance for computed-tomography simulator : Report of the AAPM Radiation Therapy Committee Task Group No.66 (Report of the AAPM Radiation Therapy Committee의 Task Group No.66에 의한 전산화 단층촬영 모의치료기의 정도 관리)

  • Lee, Yun-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.41-43
    • /
    • 2005
  • Purpose : Wish to present degree management process that is efficient confirm radiation treatment exclusive use CT simulator's Q.A item that become Q.A and Differentiation of diagnosis area that present Report of the AAPM Task Group No.66 using Q.A tool that produce itself and secure safe and correct CT-simulation process and equip convenience. Method and material : Manufacture CT simulator's Q.A tool on source and confirm virtue between isocenter of wall laser system, patient table, CT scanner's imaging plane that present in Report of the AAPM Task Group No.66 by daily publication unit. Result : Confirmed measured value from Report of the AAPM Task Group No.66 to confirmation of presenting degree management item in wall laser's ${\pm}2mm$, table's ${\pm}2mm$, imaging plane's ${\pm}2mm$ tolerance extent. Conclusion : There is unconfirmed item from CT-simulation process for therapy to CT Q.A protocol of existent diagnosis area, premising suitable degree management of radiation treatment exclusive use CT-simulator equipment confirming presenting Q.A item in Report of the AAPM Task Group No.66 safe and correct CT-simulation process guarantee can

  • PDF

Efficacy of new inspection system of Anticancer Drug Prescription (새로운 항암제 처방 감사 시스템 도입을 통한 의료의 질 향상)

  • Kim, M.S.;Kim, Y.K.;Lee, Y.J.;Choi, Y.J.;Shin, H.Y.;Song, Y.C.
    • Quality Improvement in Health Care
    • /
    • v.14 no.2
    • /
    • pp.125-132
    • /
    • 2008
  • Background : The number of outpatient injected anticancer drug is increasing. and the pathway of prescribing, compounding, and injecting anticancer drug is processed very rapidly in out-patient department. Moreover, Dose of anticancer drug is often changed depending on side effect of patients. So we need more effective inspection of anticancer drug prescriptions. The purpose of this study was to analyze the prescription errors for anticancer drugs in Out-Patient Department and to suggest system to prevent them. Method : The study took place at Asan Medical Center from July to September 2007. The pharmacists performed inspection of anticancer drug prescriptions before compounding and injecting. We used protocol-based anticancer drug order program and Electronic Medical Record (EMR). Result : During the study period, we analyzed 4683 prescriptions for out-patient. And we detected 55 medication errors (1.2%). Most common errors included dosage above or below the correct ones (56.3%), followed by incorrect treatment duration. Because most of dosing errors were in the range of usual dosage, it was hard to detect them. So when inspecting the prescription, we considered the medical records of individual patients. As a result, we could raise the efficiency of intervention. Therefore inspection using EMR could possibly reduce the number of anticancer drug errors. Conclusion : we are preventing the medication errors on stability and dosage above or below the maximum therapeutic dose according to the previous inspection system. However most of dosing errors were in the range of usual dosage according to the result of this study. Because of there was interpatient variability of dosage depending adverse effect. For improvement of quality assurance, we suggest inspection system based on patient's medical history.

  • PDF

The Study on the Integrated Monitoring of Water Quantity and Quality Data (수량 및 수질관측 통합연계 운영 연구)

  • Yi, Jae-Eung;Kim, Mun-Mo;Park, Sung-Je
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.115-123
    • /
    • 2009
  • Integrated information to water quantity and quality is essential for planning water resources management as well as operating water-related infrastructures. Because data collection process including monitoring and maintenance is separated in different governmental agencies in Korea, integrating quantity and quality may provide effective and better management implementation. In this study, a number of suggestions regarding integration of water monitoring were concluded in terms of technological, legal and institutional implications. First, it is necessary to discuss national water monitoring plan, national water information management plan, agreement of standard terms of monitoring between ministries, and to revise the law(river law and water quality management law). Present stations for water monitoring should be used for both of quantity and quality monitoring. If station is newly installed or relocated, it is better that one single agency maintain monitoring frequency and data management as well. In addition, a monitoring protocol need to be agreed by each of parties. In order to develop integrated monitoring system, quality assurance of the collected data should be properly maintained. Since many purposes haven been concerned using of data analysis and assessment so far, it may not be easy to integrate water quantity and quality monitoring in a short period. However, the alternatives including enhancing institutional regulations and programs, advanced technology may promote an efficient integrated water monitoring.

Survey of Current Status of Quality Control of Gamma Cameras in Republic of Korea (감마카메라 정도관리 실태 조사)

  • Choe, Jae-Gol;Joh, Cheol-Woo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.314-322
    • /
    • 2008
  • Purpose: It is widely recognized that good quality control (QC) program is essential for adequate imaging diagnosis using gamma camera. The purpose of this study is to survey the current status of QC of gamma cameras in Republic of Korea for implementing appropriate nationwide quality control guidelines and programs. Methods: A collection of data is done for personnel, equipment and appropriateness of each nuclear medicine imaging laboratory's quality control practice. This survey is done by collection of formatted questionnaire by mails, emails or interviews. We also reviewed the current recommendations concerning quality assurance by international societies. Results: This survey revealed that practice of quality control is irregular and not satisfactory. The irregularity of the QC practice seems due partly to the lack of trained personnel, equipment, budget, time and hand-on guidelines. Conclusion: The implementation of QC program may cause additional burden to the hospitals, patients and nuclear medicine laboratories. However, the benefit of a good QC program is obvious that the hospitals can provide good quality nuclear medicine imaging studies to the patients. It is important to use least cumbersome QC protocol, to educate the nuclear medicine and hospital administrative personnel concerning QC, and to establish national QC guidelines to help each individual nuclear medicine laboratory.

CSMA/CA based Transmission Scheme for QoS Assurance and Energy Efficiency of WPAN Systems (CSMA/CA 경쟁방식 기반의 WPAN 시스템을 위한 QoS 보장 및 에너지 효율적 전송방식)

  • Joo, Yang-Ick;Lee, Yeon-Woo;Jung, Min-A;Jang, Bong-Seog;Lee, Seong-Ro
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.3B
    • /
    • pp.135-143
    • /
    • 2008
  • In this paper, we propose a QoS guaranteed and energy-efficient transmission scheme for Wireless Personal Area Networks (WPANs), which operate in conjunction with contention-based access protocols such as CSMA/CA. Energy consumption is one of the most important issues in WPAN systems, because WPAN devices are often required to operate under limited battery capacity. Furthermore, if the WPAN adopts a contention-based medium access protocol, the energy consumption problem becomes even more critical due to the collisions caused by independent channel access trials. Therefore, in this paper, we propose an algorithm that selects the optimum fragment size, modulation level, and transmission power, in order to minimize the energy consumption and guaranteethe QoS (Quality of Service) requirements, simultaneously. Our simulation results show that the proposed algorithm has better performance than the previous ones.

TOSS: Telecom Operations Support Systems for Broadband Services

  • Chen, Yuan-Kai;Hsu, Chang-Ping;Hu, Chung-Hua;Lin, Rong-Syh;Lin, Yi-Bing;Lyu, Jian-Zhi;Wu, Wudy;Young, Hey-Chyi
    • Journal of Information Processing Systems
    • /
    • v.6 no.1
    • /
    • pp.1-20
    • /
    • 2010
  • Due to the convergence of voice, data, and video, today's telecom operators are facing the complexity of service and network management to offer differentiated value-added services that meet customer expectations. Without the operations support of well-developed Business Support System/Operations Support System (BSS/OSS), it is difficult to timely and effectively provide competitive services upon customer request. In this paper, a suite of NGOSS-based Telecom OSS (TOSS) is developed for the support of fulfillment and assurance operations of telecom services and IT services. Four OSS groups, TOSS-P (intelligent service provisioning), TOSS-N (integrated large-scale network management), TOSS-T (trouble handling and resolution), and TOSS-Q (end-to-end service quality management), are organized and integrated following the standard telecom operation processes (i.e., eTOM). We use IPTV and IP-VPN operation scenarios to show how these OSS groups co-work to support daily business operations with the benefits of cost reduction and revenue acceleration.