• Title/Summary/Keyword: Quality(0) factor

Search Result 2,422, Processing Time 0.044 seconds

Dielectric and Piezoelectric Characteristics of Low Temperature PMN-PZT Ceramics with the amount of PFW substitution (PFW치환에 따른 저온소결 PMN-PZT 세라믹스의 유전 및 압전 특성)

  • Lee, Kab-Soo;Yoo, Kyung-Jin;Lee, Hyun-Seok;Yoo, Ju-Hyun;Paik, Dong-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.181-182
    • /
    • 2005
  • In this study, in order to develop multilayer piezoelectric transformer, PMN-PZT ceramics were fabricated according to PFW substitution using $Li_2CO_3-CaCO_3$ as sintering aids and their dielectric and piezoelectric characteristics were investigated. As increasing the amount of PFW substitution, density was slightly increased due to the increased sinterability. At the 1[mol%] PFW substituted PMN-PZT ceramic sintered at 950[$^{\circ}C$], density, dielectric constant $\varepsilon_r$, electromechanical coupling factor kp, mechanical quality factor Qm and piezoelectric $d_{33}$ constant showed the optimum value of 7.761[$g/cm^3$], 1251, 0.479, 1425 and 282[pC/N], respectively.

  • PDF

Effect of Work Intensity on Fit Factor and Affecive Quality of Dustproof Mask (작업 강도가 방진 마스크의 밀착도와 감성품질에 미치는 영향)

  • Lee, Jinsil;Cho, Sunhee;Yun, Jungmin;Kim, Min-Sun;Park, Jaekyu;Choe, Jaeho
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.2
    • /
    • pp.301-310
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the effect of work intensity on fit factor and affective quality of the dustproof Background: Among the victims who suffer pneumoconiosis due to the inhalation of toxic substances or the lack of oxygen during the work, the proportion of the victims is larger than the other causes. Wearing a respirator may prevent pneumoconiosis, but it can be hazardous to workers because of the leakage through filters, cartridges, exhaust valves, broken parts, and face-to-face contact. Despite leakage through the contact area between the mask and the face has various causes such as the wearer's activity, sweat accumulation, facial shape, etc., There is a lack of relevant research and regulation compared to developed countries that have already institutionalized the law 30 years ago and give the right to sell through a test Method: The work intensity was adjusted by walking or running at 6km/h and 11km/h on the treadmill, and tasks were defined with reference to the test procedure and the exercise sequence applied in the face leakage test of the dustproof mask. And fit factor was measured objectively using 'Respirator Fit Tester 8038' which measures fit factor calculated by dividing the number of dust present outside the mask by inside the mask. In addition, affective quality was classified by the ease of use, ease of breathing, and ease of wearing, and was measured using the 5-point likert scale questionnaire. Results: There was a significant difference in fit factor, ease of breathing, and wearing convenience according to work intensity and no significant difference in ease of use(${\alpha}=0.01$). And when the work intensity was high, fit factor, ease of breathing, and wearing convenience were all lower than when the work intensity was low. Conclusion: In Korea, it is necessary to consider consideration of the work intensity when testing the leakage rate of the face part for safety certification of the respiratory protective equipment, When developing a mask, it should be possible to maintain high adhesion even under intense, active situation and high temperature conditions by selecting materials, improving the wearing style, and expanding the adjustable range.

Quality Characteristics of Cookies Made with Chestnut Inner peel Powder (율피가루 첨가 쿠키의 품질 특성)

  • Shin, Seung Mee;Kim, Eun Gyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.483-492
    • /
    • 2017
  • This study investigated the quality characteristics of cookies made with chestnut inner peel powder and its potential as a food ingredient. Cookies were made with various levels (0, 10, 20, 30, 40%) of chestnut inner peel powder. Dough pieces were baked for 20 minutes at $180^{\circ}C$ in an electrically heated rotary oven for about 10 minutes, and all items were measured after cooling for 24 hours at normal temperature. Quality characteristics were measured by moisture content, leavening rate, loss rate, spread factor, color, texture profile analysis, and sensory evaluations. The moisture content of cookies was significantly affected by increasing chestnut inner peel powder (p<0.001). The spread factor as well as L-value and b-value of cookies significantly decreased with increasing chestnut inner peel powder content (p<0.001). However, hardness and redness (a-value) of cookies significantly increased with increasing chestnut inner peel powder content (p<0.001). The sensory score showed that cookies added with 20% chestnut inner peel powder had higher color, texture, and overall acceptability scores than other samples. As a result, quality of cookies added with 20% chestnut inner peel powder was the most suitable, and we suggest that chestnut inner peel is a good ingredient for increasing the consumer acceptability and functionality of cookies.

Analysis of the factors influencing customer satisfaction of delivery food (배달음식 이용고객의 만족도에 영향을 미치는 요인 분석)

  • Park, Min-Seo;Bae, Hyun-Joo
    • Journal of Nutrition and Health
    • /
    • v.53 no.6
    • /
    • pp.688-701
    • /
    • 2020
  • Purpose: This study was performed to evaluate the importance and satisfaction of the selective attributes of delivery food and to analyze the factors affecting customer satisfaction. Methods: A total of 574 responses were collected from customers who had ordered delivery food for data analysis. Statistical analyses were conducted using the SPSS program (ver. 25.0) for frequency analysis, χ2 tests, t-test, factor analysis, Pearson correlation, multiple regression analysis, and Importance-Performance Analysis (IPA). Results: The importance of delivery food selection attributes was higher in the order of 'hygiene control level (4.72)', 'taste of food (4.64)', and 'delivery accuracy (4.40)'. Satisfaction assessment was higher in the order of 'taste of food (4.32)', 'delivery accuracy (4.26)', and 'convenience of using the delivery app (4.21)'. According to the results of IPA, items that were priorities for improvement were charges for delivery, discount offers, sufficient description of the menu, and rapid handling of customer complaints. On an average, overall customer satisfaction score of delivery food was 4.01 out of 5 points. Additionally, five satisfaction factors were extracted by exploratory factor analysis. According to the results of multiple regression analysis, quality of delivery platform (p < 0.001), quality of delivery service (p < 0.001), convenience and diversity (p < 0.001), quality of delivery food (p < 0.001), and health and safety (p < 0.001) had significant positive effects on overall customer satisfaction. Conclusion: To increase customer satisfaction among delivery food customers, restaurant or delivery platform managers should consistently improve not only the quality of the delivery platform but also the quality of the delivery food and service.

A Low Phase Noise Design of Voltage Controlled Dielectric Resonator Oscillator and Reliability Analysis (전압제어 유전체 공진 발진기의 저위상잡음 설계 및 신뢰도 분석)

  • Ryu Keun-Kwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.2
    • /
    • pp.408-414
    • /
    • 2005
  • The VCDRO(Voltage Controlled Dielectric Resonate. Oscillator) with low phase noise is designed using nonlinear analysis, and its phase noise characteristics are compared with that of Lesson's equation. The microstripline coupled with dielectric resonator is realized as a high impedance inverter to improve the phase noise performance, and the quality factor of resonator circuit can be transferred to active device with the enhanced the loaded quality factor. The worst case and part stress analyses are achieved to obtain the high reliability of VCDRO and the reliability analysis is accomplished to estimate the probability of operation at the end of life. The developed VCDRO has the oscillating tuning factor of 0.56MHZ1V for the control voltage range of 0-l2V. This VCDRO requires the DC power of 136mW. The phase noise characteristics exhibit good performances of -94.18dBc/Hz (a)10KHz and -116.3dBc/Hz (a)100KHz. And, the output power over 7.33dBm is measured.

2.5 GHz ZnO-based FBAR Devices and Their Thermal Improvements

  • Mai, Linh;Pham, Van-Su;Yoon, Gi-Wan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.59-62
    • /
    • 2008
  • In this paper, we study ZnO-based a film bulk acoustic resonator (FBAR) using a multi-layered Bragg reflector. We insert chromium adhesion layers of 0.03 mm-thick to the Bragg reflector and improve the performance using thermal treatments. At operating frequency about 2.5 GHz, excellent resonance characteristics are observed in terms of good return loss and high quality factor.

  • PDF

Microstructure and Piezoelectric Characteristics of PSN-PZT Ceramics as a Function of PNW Substitution (PNW 치환에 따른 PSN-PZT 세라믹스의 미세구조 및 압전특성)

  • 류주현;우원희;오동언;류성림
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.10
    • /
    • pp.892-896
    • /
    • 2003
  • In this study, microstructure and piezoelectric properties of PSN-PZT ceramics modified with BiFeO$_3$ were investigated as a function of PNW substitution. With the increase of PNW substitution, tetragonality, Curie temperature and mechanical quality factor were decreased but grain size and electromechanical coupling factor(kp) was gradually increased. At 4 mol[%] PNW substitution, maximum kp of 0.567 was obtained.

Electrical properties of multilayer piezoelectric actuator with the variations of temperature (적층 압전액츄억이터 소자의 온도해 따른 전기적 특성)

  • Lee, Kab-Soo;Lee, Il-Ha;Yoo, Ju-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.63-64
    • /
    • 2006
  • In this paper, multilayer piezoelectric actuator was fabricated in order to develop ultrasonic linear motor. Multilayer actuator showed a high density of 7.78[$g/cm^3$], a large effective electromechanical coupling factor($K_{eff}$) of 0.259, a high mechanical quality factor( Qm ') of 1301, and high capacitance(c) of 19.32[nF]. Curie temperature was $343[^{\circ}C]$.

  • PDF

Quality Correction for Ir-192 Gamma Rays in Air Kerma Strength Dosimetry Using Cylindrical Ionization Chambers (원통형 전리함을 이용한 Ir-192 선원에 대한 공기커마세기 측정 시 선질보정에 관한 연구)

  • Jeong, Dong-Hyeok;Kim, Jhin-Kee;Kim, Ki-Hwan;Oh, Young-Kee;Kim, Soo-Kon;Lee, Kang-Kyoo;Moon, Sun-Rock
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.30-36
    • /
    • 2009
  • The quality correction in the air kerma dosimetry for Ir-192 using farmer type ionization chambers calibrated by Co-60 quality is required. In this study we determined quality factor ($k_u$) of two ionization chambers of PTW-N30001 and N23333 for Ir-192 source using dosimetric method. The quality factors for energy spectrum of microSelectron were determined as $k_u$=1.016 and 1.017 for PTW-N30001 and N23333 ionization chambers respectively. We applied quality factors in air kerma dosimetry for microSelectron source and compared with reference values. As a results we found that the differences between reference air kerma rate and measured it with and without quality correction were about -0.5% and -2.0% respectively.

  • PDF

Quality Control of Dose Calibrator using 3D Printery (3D 프린터를 이용한 Dose Calibrator의 품질관리)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.307-312
    • /
    • 2021
  • In nuclear medicine, radioactive isotope tracers are administered to the human body to obtain and evaluate disease morphological information and biological function information. Dose calibrator is a device used to measure the radioactivity of a single nuclide in medical institutions. Administration of the correct dose to the human body acts as an important factor in diagnosis and treatment, and measurement through a dose calibrator before administration is the most important factor. Dose calibrator performs daily quality control after installation in each medical institution. Quality control is a means of guaranteeing quality control after installation, and is essential for improving the quality of treatment and promoting patient safety. Therefore, accurate and standardized performance evaluation methods should be established. In this study, 3D printing was used for quantitative evaluation of quality control by increasing the accuracy and standardization of quality control. When the 3D printer was installed and reproducibility was tested, the error range of the expected value and reading value decreased by 0.302% in the F-18 nuclide and 0.09% in the 99mTc-pertechnate nuclide than when the 3D printer was installed. The error rate for other nuclides was also found to have a low error rate for reproducibility tests when 3D printing was installed.