A Study on Safety Distance for Small Scale LNG Storage facility (소규모 LNG 저장시설의 안전거리 기준 연구)

  • Oh, Shin-Kyu;Jo, Young-Do
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.185-191
    • /
    • 2014
  • In this study safety distance was investigated for small-scale LNG storage facilities in order to provide basic data for safety. The results are as follows; (1) For explosion pressure criteria, current criteria are reasonable, but water spray system should be recommended to LNG storage tank to ensure safety. (2) For criteria based on the results of the quantitative risk assessment, criteria applied to people are $5kW/m^2$ for radiation, LFL for dispersion, and 7kPa for explosion pressure. And criteria applied to facility are $37.5kW/m^2$ for radiation and 20 kPa for explosion pressure.

Development of Emergency Response Plan System Using Quantitative Risk Assessment in Chemical Plants (화학공장에서의 정량적 위험성 평가를 이용한 비상 대응 계획 시스템 개발)

  • 임차순;서재민;엄성인;백종배;고재욱
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.69-74
    • /
    • 2001
  • In this study, we analyzed the accident scenarios of chemical plants through the analysis of lots of chemical accidents and using experts knowledge, and looked into the method of prevention and response. Moreover, we developed a systemic and actual Emergency Response Plan Software(ERPS) that could prevent, prepare and respond totally for the chemical industry facilities using the data from the accident effect estimation from the local society and the geographic information of a chemical plant. The ERPS consists of the information for the plant and process, the consequence analysis and the ERPTA(Emergency Response Plan Tree Analysis). In conclusion, the program developed in this study could help effectively all the chemical industry facilities to prevent and respond to possible accidents.

  • PDF

A Study on Facility Criteria of Small Petrol Stations based on Quantitative Risk Assessment (정량적 위험성 평가에 기반한 간이 주유취급소 시설기준에 대한 연구)

  • Park, Wooin;Ku, Jae-Hyun;Song, Yong-Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.44-52
    • /
    • 2014
  • Small petrol stations have great potential for a wide distribution in metropolitan area in which the land value possesses primary installation cost of the facility. The objective of the present study is to propose appropriate facility regulations of small petrol stations in Korea that can be popularly installed in the future in terms of securing safety in addition to serviceability. The hazard analysis and damage prediction from the possible fire and explosion accidents were performed using a software, PHAST v.6.5. As essential components of the facility regulations proposed in this study, the regulations about the refueling lot, maximum capacity of underground tank, location of fixed refueling facilities, height of firewall for small petrol stations were subsequently compared with those for regular-sized petrol stations.

A study on the safety improvement of above ground membrane LNG storage tank (상지상식 멤브레인 액화천연가스 저장탱크의 안전성 향상 방안)

  • Lee, Seung Rim;Kim, Han Sang
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.339-345
    • /
    • 2012
  • RMembrane LNG storage tanks have been recently investigated to replace full-containment LNG storage tanks because of safety and cost aspects. Quantitative Risk Analysis (QRA) and Finite Element Method (FEM) were used to evaluate safety of membrane LNG storage tanks. In this study, structural safety evaluation results via FEM analysis showed that both membrane type and full-containment type cryogenic LNG storage tanks with 140,000 $m^3$ capacity were equivalently safe in terms of strength safety and leakage safety of a storage tank system. Also, Fault Tree Analysis (FTA) was used to improve the safety of membrane LNG storage tanks and membrane LNG tanks were modified by adding three safety equipments: impact absorber structure for the low part of the membrane, the secondary barrier to diminish the thermal stress of the corner part of the outer tank, and a pump catcher in case of falling of a pump. Consequently, the safety of the modified membrane LNG storage tanks were proved to be equivalent to that of full-containment LNG storage tanks.

A Study on Zone-based Risk Analysis System using Real-time Data (실시간 데이터를 이용한 지역기반 위험분석 시스템에 관한 연구)

  • Oh, Jeong Seok;Bang, Hyo Jung
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.83-89
    • /
    • 2013
  • Energy industry facilities can cause fatal damage for internal industry employee as well as external general people because handling various kinds of gas and harmful substance might be spread to large scale severe accident by fire, explosion, and toxic gas leakage. In order to prevent these accidents, quantification by damage effect on structure and human is tried by using quantitative risk assessment, but it is difficult to process instantly exceptional cases and requires knowledge of expert. This paper aims to minimize exceptional cases and knowledge of expert, and present risk with human perceptible. So, we designed and developed zone-base risk analysis system that can compute risk of zone in real time at that point using database and incremental model.

Study on the Establishment of a Safety Allowance Level of Disastrous and Hazardous Facilities in Large Cities (대도시 위해.위험시설에 대한 안전도 수용기준 정립에 관한 연구)

  • 고재선;윤명오
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.84-92
    • /
    • 2001
  • In today's world, rise in the establishment of social infrastructure resulting from population saturation in large cities has led to more extensive and frequent use of chemical materials on facilities. A result, unexpected and serious accidents, hazards, contingencies and disasters are more prevalent than ever. Such phenomenon calls for more devoted and concerted efforts towards finding ways to reduce the safety hazards that are seen to take place more often than before with the increase in the number of facilities that are prone to bring disaster and hazard coupled with the conventional safety problems that continue to exist even today. In developed countries, such challenge is addressed by various appropriate countermeasures drawn up by local professional committees on industrial facilities, whose members conduct offsite and onsite evaluation un the potential industrial disasters and its seriousness and provide their advice thereof. Against this backdrop, this study aims at identifying a comprehensive safety allowance level (safety acceptable level) when imposing limitation on the development of conventional or new facilities, for the fur pose of establishing a safety allowance level of disastrous and dangerous facilities in Korea. This is done by assessing and applying the level of danger each individual is exposed to in a randomly selected region (disastrous and dangerous areas in Seoul) based on probability of quantitative hazards, as well as simulation and calculation methods which include: i) social disaster evaluation method applying Quantified Risk Assessment of Health & Safety Executive of UK and Matrix of Risk of Evaluated Sources of Hazard; ii) Fault Tree or Event Tree Analysis and etc.

  • PDF

A study on the selection of the optimal smoke control mode in train platform through quantitative risk assessment (정량적 위험도 평가를 통한 열차 승강장 화재시 최적 제연모드 선정에 관한 연구)

  • Lee, Bo-Hoon;Hong, Seo-Hee;Baek, Doo-San;Lee, Ho-Hyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.539-552
    • /
    • 2022
  • In the case of train stations, due to the specificity of underground spaces with limited smoke emissions, if appropriate removal equipment is not equipped, the damage caused by fire smoke may increase in the event of a fire. As a result, the need for measures to ensure the safety of evacuation of underground stations has been highlighted, and research for safe evacuation of platform users in case of fire is continuously being conducted at home and abroad. However, although the smoke removal area is currently divided by smoke boundary walls and platform screen doors (PSD) and installed in the train platform, standards for smoke removal methods (air supply or exhaust) for each fire removal area, that is, smoke removal mode, are not presented. In this study, fire analysis and evacuation analysis were performed to estimate the number of deaths and to derive F/N guidance in order to quantitatively evaluate the fire risk according to the fire station fire, and the total risk was the lowest in the case of fire area exhaust and supply to adjacent areas.