• 제목/요약/키워드: QA Program

검색결과 56건 처리시간 0.019초

결핵 적정성 평가에 따른 국내 결핵 진료서비스 질 관리 현황 (Change in Quality of Tuberculosis (TB) Care since National Quality Assessment Program of TB Healthcare Service)

  • 장성자;황미진;이충훈;이현주;심태선;김동숙
    • 한국의료질향상학회지
    • /
    • 제27권2호
    • /
    • pp.73-82
    • /
    • 2021
  • Purpose: This study aims to examine the quality of tuberculosis (TB) care after the 1st to 3rd national quality assessment (QA) program for TB healthcare service in Korea was conducted. Methods: We analyzed Health Insurance Review & Assessment Service (HIRA) claims data of new TB patients during the period of January to June from 2018-2020. The new TB patients were defined as TB patients reported to Korea Centers for Disease Control and Prevention Agency (KCDA). The unit of analysis was the patient. Chi-square tests were used to analyze the differences in indicator value according to the types of medical facilities. The QA indicators of TB care were divided into 3 areas consisting of the following 7 quality indicators: 4 indicators of diagnosis test (the rate of acid-fast bacilli smear, the rate of acid-fast bacilli culture, the rate of Mycobacterium tuberculosis-polymerase chain reaction, drug susceptibility test), 1 compliance of treatment guideline, and 2 indicators of care management of TB patients (encounter rate, day of therapy). Results: The QA program for TB care was conducted among 8,246 patients from 534 facilities in 2020. The value of the 7 quality indicators was shown to increase as a result of the QA program. The indicators of the diagnostic test were all higher than 95%, with the exception of the drug susceptibility test which was 84.8%. Both indicators for care management of TB patients were 88.5%. Conclusion: The quality of TB care has been improving with the implementation of the QA program. In order to continue to improve the quality of TB care, it will be necessary to disclose the results of the QA program in medical facilities in the future.

A Case Study of Asphalt Pavement Construction Quality Assurance Using the Quality Related Specification Software

  • Jeong, M. Myung;Jung, Younghan
    • Journal of Construction Engineering and Project Management
    • /
    • 제6권3호
    • /
    • pp.14-21
    • /
    • 2016
  • One of the major issues in the material-based or acceptance quality characteristics asphalt pavement Quality Assurance (QA) is that the method does not have rationality to link between the individual materials and the projected performance of the pavement. A new asphalt mix QA method has been recently developed under a national research project using the probabilistic Performance Related Specification (PRS). This advanced PRS QA methodology integrates the AASHTOWare Pavement ME Design$^{(R)}$ technology with the simple performance test concept that bridges the material characteristics with the pavement performance. This paper presents a case study of asphalt pavement performance using the developed PRS QA computer program, named Quality Related Specification Software (QRSS), with an actual pavement project, to demonstrate the developed PRS procedure and to assess the robustness of QRSS in terms of the rationality of the distress predictions. The results of this limited case study show that the new PRS QA method reasonably predicts the pavement performance, properly applied the probabilistic methods, and produced rational pay adjustment.

의료용 선형가속기의 기계적 점검을 위한 새로운 정도관리 프로토콜의 개발 (Development of New Prototype of Mechanical Quality Assurance for Clinical Linear Accelerator)

  • 윤형근;신교철;김기환;오영기;김진기;정동혁;김정기;조문준;박인규
    • 한국의학물리학회지:의학물리
    • /
    • 제13권3호
    • /
    • pp.109-113
    • /
    • 2002
  • 본 연구에서는 의료용선형가속기의 기기점검을 위한 일목요연하고 장기간의 통계처리가 가능한 새로운 정도관리 양식을 개발하였다. 개발된 양식을 2001년 8월부터 12월까지 국내의 6개의 기관에 적용하여 그 양식의 효율성을 평가하였다. 기존의 점검 양식은 단순히 선형가속기에 숫자로 표시되는 값들(digital data)과 측정장치를 이용하여 관찰된 값들(mechanical data)의 비교에 목적을 두고 있고, 각 항목들이 서술적으로 나열되어 있어 공간적으로 문제점을 파악하기 어렵다. 더욱이 기기의 장기간에 걸친 오차의 변화를 일목요연하게 알 수가 없다. 그러나 새로 개발된 점검 양식을 사용한다면, 디지털 데이터와 기계적 데이터의 비교는 물론 기기의 오차를 공간적으로 파악할 수 있게 될 것이다. 또한 기기의 장기간에 걸친 오차의 범위를 확인하게 되어 기기의 장기적 안정성을 알 수 있게 될 것이다. 뿐만 아니라 현실에 맞는 항목을 선택함으로써 기계적 정도관리(mechanical QA)를 수행하는 시간을 단축함과 동시에, 각 기관이 보유하고 있는 선형가속기의 장기간에 걸친 정도관리를 통해 얻은 데이터를 이용하여 치료장비의 오차에 대한 통계적, 물리적 데이터를 정도관리 직후 분석할 수 있게 되어 방사선 치료에 있어서 매우 중요한 요소인 방사선 치료장비의 기기적 정확성을 높일 수 있게 될 것이다.

  • PDF

Segmental Analysis Trial of Volumetric Modulated Arc Therapy for Quality Assurance of Linear Accelerator

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Huh, Hyun Do;Kim, Seonghoon
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.128-138
    • /
    • 2019
  • Purpose: Segmental analysis of volumetric modulated arc therapy (VMAT) is not clinically used for compositional error source evaluation. Instead, dose verification is routinely used for plan-specific quality assurance (QA). While this approach identifies the resultant error, it does not specify which machine parameter was responsible for the error. In this research study, we adopted an approach for the segmental analysis of VMAT as a part of machine QA of linear accelerator (LINAC). Methods: Two portal dose QA plans were generated for VMAT QA: a) for full arc and b) for the arc, which was segmented in 12 subsegments. We investigated the multileaf collimator (MLC) position and dosimetric accuracy in the full and segmented arc delivery schemes. A MATLAB program was used to calculate the MLC position error from the data in the dynalog file. The Gamma passing rate (GPR) and the measured to planned dose difference (DD) in each pixel of the electronic portal imaging device was the measurement for dosimetric accuracy. The eclipse treatment planning system and a MATLAB program were used to calculate the dosimetric accuracy. Results: The maximum root-mean-square error of the MLC positions were <1 mm. The GPR was within the range of 98%-99.7% and was similar in both types of VMAT delivery. In general, the DD was <5 calibration units in both full arcs. A similar DD distribution was found for continuous arc and segmented arcs sums. Exceedingly high DD were not observed in any of the arc segment delivery schemes. The LINAC performance was acceptable regarding the execution of the VMAT QA plan. Conclusions: The segmental analysis proposed in this study is expected to be useful for the prediction of the delivery of the VMAT in relation to the gantry angle. We thus recommend the use of segmental analysis of VMAT as part of the regular QA.

Quality Driven Approach for Product Line Architecture Customization in Patient Navigation Program Software Product Line

  • Ashari, Afifah M.;Abd Halim, Shahliza;Jawawi, Dayang N.A.;Suvelayutnan, Ushananthiny;Isa, Mohd Adham
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권7호
    • /
    • pp.2455-2475
    • /
    • 2021
  • Patient Navigation Program (PNP) is considered as an important implementation of health care systems that can assist in patient's treatment. Due to the feasibility of PNP implementation, a systematic reuse is needed for a wide adoption of PNP computerized system. SPL is one of the promising systematic reuse approaches for creating a reusable architecture to enabled reuse in several similar applications of PNP systems which has its own variations with other applications. However, stakeholder decision making which result from the imprecise, uncertain, and subjective nature of architecture selection based on quality attributes (QA) further hinders the development of the product line architecture. Therefore, this study aims to propose a quality-driven approach using Multi-Criteria Decision Analysis (MCDA) techniques for Software Product Line Architecture (SPLA) to have an objective selection based on the QA of stakeholders in the domain of PNP. There are two steps proposed to this approach. First, a clear representation of quality is proposed by extending feature model (FM) with QA feature to determine the QA in the early phase of architecture selection. Second, MCDA techniques were applied for architecture selection based on objective preference for certain QA in the domain of PNP. The result of the proposed approach is the implementation of the PNP system with SPLA that had been selected using MCDA techniques. Evaluation for the approach is done by checking the approach's applicability in a case study and stakeholder validation. Evaluation on ease of use and usefulness of the approach with selected stakeholders have shown positive responses. The evaluation results proved that the proposed approach assisted in the implementation of PNP systems.

Elekta Synergy 선형가속기를 이용한 입체적세기조절회전방사선치료(VMAT) 정도관리 (Quality Assurance of Volumetric Modulated Arc Therapy for Elekta Synergy)

  • 심수정;심장보;이상훈;민철기;조광환;신동오;최진호;박성일;조삼주
    • 한국의학물리학회지:의학물리
    • /
    • 제23권1호
    • /
    • pp.33-41
    • /
    • 2012
  • 최근 환자맞춤형방사선치료를 위해 임상에서 활용하고 있는 입체적세기조절회전방사선치료의 정도관리를 수행하고자 기존의 세기조절방사선치료에서 수행하는 정도관리 프로그램을 본 원의 실정에 맞게 치료계획단계 정도관리(Treatment planning QA), 치료전 전달단계 정도관리(Pretreatment delivery QA), 치료단계 정도관리(Treatment QA)인 세 가지 단계로 나누어 설정하였다. 각 정도관리 단계에서는 정도관리 프로그램에 따라 점검할 항목과 측정하여 평가할 항목을 설정하여 문서화를 위해 서식화 하였다. 본 원에서는 서식화한 정도관리 프로그램에 따라 실제 치료환자에 적용하였으며 본원의 치료전 전달 정도관리의 임상 허용기준을 위해 국소적 신뢰수준(confidence limit, CL)을 평가하였다. 그 결과 고선량 영역 점선량 측정, 저선량영역 점선량 측정의 CL는 모두 기존의 IMRT 수준과 유사한 결과를 얻었으며 이를 토대로 본원의 임상허용 기준은 고선량영역은 3%, 저선량 영역은 5%로 설정하였다. 입체적세기조절회전방사선치료의 특성상 Intensity map 평가는 360도 전 방향에서 Intensity map을 측정할 수 있는 ArcCheck 기기를 사용 하여 감마 지표(Gamma Index) 평가를 하였으며 그 결과는 IMRT의 개별적 intensity map 평가와 유사한 결과를 얻었으며 본원의 CL은 93%로 설정하였다. 등선량분포 평가는 2D detector array인 Mapcheck을 사용하였으며 95% 이상의 일치도를 보여 본원의 CL은 95%로 설정하였다. 방사선치료 정도관리에서 임의의 불확도와 계통 오차를 줄이려면 실제 환자 적용에 앞서 다 기관이 참여하는 팬톰을 이용한 국소적 CL 평가를 권장하고 있다. 국내 여건상 다 기관이 참여하는 연구가 여의치 않다면 본 연구와 같이 개별 기관에서 자체적으로 허용검사가 끝난 후에 실제 임상에서는 환자 치료 부위별로 세분화 하여 국소적 CL을 평가하는 방법이 유용할 것으로 사료된다.

국내 1차 수혈 적정성 평가 시행에 따른 수혈서비스 질관리 현황 (Assessing the Quality for Blood Transfusion Service since the 1st National Quality Assessment Program in South Korea)

  • 권진아;조은정;정아현;김동숙
    • 한국의료질향상학회지
    • /
    • 제28권2호
    • /
    • pp.30-38
    • /
    • 2022
  • Purpose: The Health Insurance Review and Assessment Service (HIRA) in South Korea initiated a quality assessment (QA) program for blood transfusion healthcare services in 2020 to ensure patient safety and appropriate blood use. This study examines the quality of blood transfusion services since the first national QA program for blood transfusion services in Korea. Methods: We analyzed HIRA claims and QA investigation data based on inpatient medical records from all tertiary, general, and primary hospitals between October 2020 and March 2021. The target population was patients aged 18 years and older who received either total knee arthroplasty or red blood cell transfusion. The QA indicators for transfusion healthcare service consisted of four quality indicators and four monitoring indicators. Results: We analyzed the results of QA indicators for transfusion service from the medical records of 189,668 patients from 1,171hospitals and expressed indicators as proportions. The average results for evaluation indicators were as follows: transfusion checklist presence, 64.8%; irregular antibody tests, 61.8%; transfusions in which the hemoglobin levels before transfusion met the transfusion guidelines for patients undergoing total knee arthroplasty, 20.6%, and transfusions in patients undergoing total knee arthroplasty, 59.3%. The average results for monitoring indicators were as follows: transfusion management implementation in medical institutions, 56.9%; preoperative anemia management in anemia patients undergoing total knee arthroplasty, 43.9%; one-unit transfusions, 82.5%; and the transfusion index. Conclusion: The quality of blood transfusion healthcare varied and the assessment revealed that there is scope for improvement. Hospitals require more effective blood transfusion management and this can be facilitated by providing feedback on the QA results about blood transfusion healthcare services to medical institutions, and by disclosing the results to the public.

대학병원 질 향상 관련 위원회 소속 의사들의 의료 질 관리 활동에 대한 인식 및 태도 (Attitudes toward Quality Improvement Activities of QA Committee Member Physicians in Korean University Hospitals)

  • 이상일
    • 한국의료질향상학회지
    • /
    • 제5권1호
    • /
    • pp.76-91
    • /
    • 1998
  • Background : The purpose of this study was to understand general attitudes of physicians toward hospital quality improvement activities who have been members of QA committee in 32 Korean university hospitals. Methods : A postal survey about opinions of hospital quality improvement activities and desirable policy directions was sent to 328 QA committee member physicians. The questionnaires were composed of 48 items. In total 152 physicians responded to this survey(response rate: 49.3%). This study was carried out from January to February 1996. Results : Most physicians(97.5%) recognized the necessity of hospital QA activities. The most dominant supporting reason for quality activities was to improve clinical outcome. Two thirds of physicians regarded their own hospital activities for quality improvement as inactive. They considered that the obstacles were too little concern(33.6%), unclear objectives(28.9%), lack of human resources(14.3%), and insufficient education and training for quality improvement(10.1%). The most favoring policy among respondents was to give health care providers economic incentives. Provision of education and training for implementing quality improvement was the next to it. Physicians revealed their preferences for professional society, government, health insurance societies, consumer groups, hospital labor unions, and mass media in sequence as sponsoring agencies for hospital accreditation program. Conclusion : These study suggested that the concrete means for motivating physicians and promoting constructive partnership among related parties should be developed in order to activate current hospital quality activities in Korea.

  • PDF

방사선치료계획 시스템의 정도관리 절차서 개발 및 유용성 평가 (Development and Evaluation of Quality Assurance Worksheet for the Radiation Treatment Planning System)

  • 조광환;최진호;신동오;권수일;최두호;김용호;이상훈
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.186-191
    • /
    • 2004
  • 방사선 치료에서 각 방사선치료 관련 장비의 주기적인 정도관리는 매우 중요하나, 방사선 발생장치에 비하여 방사선치료계획시스템(RTPS)에 대한 정도관리는 아직 미흡한 상태이다. 따라서 본 연구에서는 방사선치료계획시스템의 정도 관리를 위해서 주기적인 정도관리 항목을 제시하고, 수행함으로써 국내에서 사용하고 있는 치료계획시스템들의 성능을 비교, 평가해보고자 한다. 정도관리 항목은 입ㆍ출력 장치와 같은 비 선량학적 측면과 선량계산 결과에 관련된 선량학적 측면으로 크게 분류하였고, 수행 시간, 에러 발생률, 중요도에 따라서 주간, 월간, 연간, 비정기적으로 분류하였다. 불균질 상태를 모사한 물 등가 고체팬톰을 컴퓨터단층 촬영하여 영상을 얻었으며, RTPS에 입력하여 정도관리를 수행하였다. 입출력 장치는 장비의 오작동 여부를 점검하고 입출력 후 실제 영상과의 크기 차이를 비교하였고, 선량계산 항목은 정방형 조사면, 부정형 조사면, 쐐기 조사면, 불균질 물질 보정, 사방향 조사 등에 대해 수행하였다. 에너지는 6 MV, 10 MV를 이용하여 이온검출기를 통해 기준점에서의 실제 측정값을 얻었고, 계산된 값과 실제 측정한 값을 비교하여 RTPS의 정확도를 평가하였다. 기하학적 정확도와 선량의 정확도를 평가한 결과 선진 각국 및 각 학회에서 권고하고 있는 허용 범위 내에서 대부분 일치하였다. 따라서 방사선치료의 성적을 향상시키기 위해서 주기적인 정도관리가 요구되며, 본 연구결과를 토대로 RTPS의 정확성을 평가하기 위하여 국내 실정에 적합한 주기적인 정도관리 프로그램을 제시할 수 있을 것으로 생각된다.

  • PDF