• 제목/요약/키워드: QA/QC

검색결과 91건 처리시간 0.024초

16종 다용한약재의 산지별 As, Cd, Pb, Co, Cr 농도 및 특성고찰 -한국과 중국산의 평균농도, 최소-최대농도와 법적 허용농도초과비율을 중심으로- (As, Cd, Pb, Co, Cr Concentration and Property Evaluation in Frequently Using 16 Oriental Herbal Medicines -Mainly Average, Lowest, Highest Concentration and Percent Exceeding Value of Legal Allowance in Korean and Chinese Origines-)

  • 김기동;박해모;서용찬;이선동
    • 대한예방한의학회지
    • /
    • 제16권3호
    • /
    • pp.167-183
    • /
    • 2012
  • Objective : Average, lowest, highest concentration and exceeding value of legal allowance of As, Cd, Pb, Co, Cr in frequently using 16 oriental herbal medicines in korea(Astragali Radix, Ginseng, Citri Unshii Pericarpium, Aurantii Fructus Immaturus, Angelicae Gigantis Radix, Cnidii Rhizoma, Paeoniae Radix, Rehmanniae Radix Preparata, Zingiberis Rhizoma Crudus, Zizyphi Fructus, Atractylodis Rhizoma Alba, Hoelen, Dioscoreae Rhizoma, Corni Fructus, Schisandrae Fructus, Lycii Fructus) was evaluated according to their origines (korea, china) and property was also discussed according to the medicinally active part and individuals regardless origines. Method : Korean and Chinese herbal medicines were evenly sampled from corresponding country nationwide. Pre-treatment was executed according to the KFDA(Korea Food and Drug Administration) regulation and analysis was performed according to the Korean Environmental Analysis QA/QC. Result : Not much difference was observed according to their origines. However, lowest, highest and percent exceeding value of legal allowance was showed some consistent differences according to the medicinally active part and individuals. Co and Cr was can not be evaluated since their legal regulation was not established yet. Conclusion : The average concentration of As, Cd, Pb, Co, Cr in frequently using 16 oriental herbal medicines in korea showed no noticeable difference according to their origines. Regardless the origin, some consistent differences were observed according to the individuals and medicinally active parts.

면역크로마토그래피를 이용한 E. coli O157: H7 신속검출 키트의 유효성 평가 (Evaluation of the Efficiency of E. coli O157: H7 Rapid Detection Kit using Immunochromatography)

  • 곽효선;이동하;문희숙;박종석;우건조;김창민
    • 한국식품위생안전성학회지
    • /
    • 제18권3호
    • /
    • pp.118-124
    • /
    • 2003
  • 식품으로부터 다양한 병원 미생물을 신속 검출하기 위하여 다양한 검출 원리를 이요한 키트들이 개발 시판되고 있다. 검사키트는 신속, 정확하고 간단하게 사용할 수 있으므로 검사기관이나 실험실 뿐 아니라 식품회사에서 QC 또는 QA를 수행하기 위하여 사용이 증가되고 있는 추세이다. 이에 본 연구에서는 E. coli 0157:H7의 단클론항체를 이용하여 면역크로마토글래피법에 의해 개발된 E. coli 0157:H7 검출 키트(Donga Co, Korea, D-kit)에 대한 검출감도 및 특이성을 확인하고 식품 시료에 적용 가능성을 평가하였다. 면역크로마토그래피법에 의하여 개발 시판되고 있는 Reveal E. coli 0157:H7 kit (Neogen Co., USA. R-kit)와 VIP EHEC kit(Biocontro Inc., USA. V-kit)를 비교 키트로 사용하였다. E. coli 0157:H7 표준균주를 사용하여 실시한 검출감도 확인시험 결과 R-kit 및 D-kit는 104/m/의 농도에서 양성으로 확인되었고 $10^3$/ml에서도 약한 양성 반응을 보였으나, V-lit는 $10^5$/ml농도로 검출감도가 낮았다. 또한, 배양액을 가열하여 kit에 적용하는 것이 가열하지 않은 경우보다 검출감도를 높일 수 있었다. E. coli 0157:H7 분리 22주, verotoxin 생성 E. coli 7주 E. coli 분리주 40주 중 3주를 제외한 모든 균에서 음성의 결과를 보여 특이성을 확인하였다. 세 키트에 위양성 반응을 보인 것은 E. coli 0157:H19, E. coli 0148:H18 및 Salmonella gallinarium으로 이들 혈청형과 0157:H7 사이에는 유사한 혈청학적 특성이 존재하는 것으로 추정되었다. 이상의 실험결과로 D-kit는 E. coli 0157:H7을 검출하는데 감도 및 특이성 면에서 기존 키트인 R-kit 및 V-kit와 같이 이용한 것으로 확인되었다.

항만·어항개발사업의 해역이용협의서 작성실태 평가 및 개선방안 (Assessment and Improvement of Documentation Status on the Statements for the Sea Area Utilization Consultation according to the Project of Ports and Fishery Harbors)

  • 탁대호;오현택;김귀영;이대인
    • 해양환경안전학회지
    • /
    • 제21권4호
    • /
    • pp.361-371
    • /
    • 2015
  • 본 연구는 최근 3년간의 항만 및 어항개발사업에 따른 해역이용협의서 91건을 분석하여 그 작성실태(평가항목별 조사현황과 영향예측 등)를 파악하고, 문제점을 개선하기 위한 방안을 요약 제시하였다. 9개 평가항목 중에서 해양화학, 해양퇴적물 및 해양생태계 부분에서는 현장조사 비율이 높았으나(70 % 이상), 조사자료를 활용한 영향예측은 미흡하였다. 반면, 해양물리의 경우는 현황조사 비율은 낮았지만(조석 7.7 %, 조류 24.2 %), 영향예측 수행비율은 높아 예측결과를 뒷받침할 만한 근거와 검증 측면에서 문제점이 있었다. 즉, 조사와 예측에 대한 평가가 연관성이 낮아 신뢰성이 떨어지고 있었다. 항만 및 어항개발사업에 있어 영향예측과 밀접하게 관련되어 있는 주요 외력(조석, 조류 및 파랑 등) 및 중점평가사항에 대한 체계적인 진단이 필요하나, 현재는 사업유형을 고려하지 않는 일반적인 평가방법과 자료인용이 이루어지고 있는데, 향후 사업규모와 지역특성 등을 고려한 중점평가항목과 구체적 평가사항(조사시기, 정점선정)을 사전에 스코핑해 줄 수 있는 제도적 장치가 필요할 것이다. 또한, 현장조사자료의 신뢰성 강화를 위해 해양화학 및 해양퇴적물의 분석에 관한 정도관리체계의 적용이 강화되어야 할 것이다.

자외선/가시선 분광법을 이용한 토양 중 6가 크롬 분석방법의 방해요인 분석 및 이온크로마토그래피 적용에 관한 연구 (A Study of Interference Factor of Analysis Method of Hexavalent Chromium in Soil using UV/VIS Spectrometry and Application of Ion Chromatography)

  • 노회정;이명규;이현석;김미라;김동호;김태승
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권6호
    • /
    • pp.33-42
    • /
    • 2012
  • This study was performed to find the problems according to interference factors (organic matter, pH, Cr, Mn, Fe, clay, and etc.) when we analyzed the hexavalent chromium [Cr(VI)] in soils using UV/VIS spectrometer (US EPA 7196A), attempted to evaluate the domestic applicability of analytical method (US EPA 7199) using IC-UV/VIS spectrometer as alternative method. The recovery rate of certified reference materials was 75.0% (US EPA 7196A) and 101.4% (US EPA 7199) by the analytical methods. As the results of performing QA/QC about US EPA 7199, method detection limit (MDL) and limit of quantification (LOQ) were 0.062 mg/kg, 0.196 mg/kg, respectively. The LOQ of US EPA 7199 was lower than that of the current soil official testing method in Korea (0.5 mg/kg). Cr(VI) contents in 23 soil samples were compared by the analytical methods of EPA 7196A and 7199. Cr(VI) was detected in 13 of 23 soil samples by EPA 7196A, while EPA 7199 was not detected in any soil samples. The Cr(VI) content in 23 soil samples by EPA 7196A was not clearly correlated with Cr, Fe, Mn and clay content in the soil samples. However, the contents of Cr(VI) and organic matter of the soil samples had the highest coefficient of determination ($R^2$) of 0.80. In order to evaluate the correlation between the recovery rates of Cr(VI) and organic matter contents in the soil samples, the recovery rates of 5 soil samples added Cr(VI) standard solution were analyzed by the analytical methods. According to the results, the higher the organic matter contents in soil samples, the lower the recovery rates of Cr(VI) by US EPA 7196, while in case of US EPA 7199, the recovery rates were stable regardless of the organic matter contents.

환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구 (A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere)

  • 손은성;서영교;이동현;이민도;한진석;백성옥
    • 한국대기환경학회지
    • /
    • 제25권6호
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.

교면포장의 수분손상 저감을 위한 체류수 배수공법 개발 (Development of a Drainage System to Mitigate Moisture Damage for Bridge Deck Pavements)

  • 이현종;김형배;서재운
    • 한국도로학회논문집
    • /
    • 제9권2호
    • /
    • pp.129-140
    • /
    • 2007
  • 본 연구의 주목적은 최근 국내 아스팔트 교면포장의 가장 빈번한 파손의 하나인 포트홀의 발생을 저감하기 위해 포장체내에 체류된 수분을 신속히 배수할 수 있는 배수시스템을 개발하는 것이다. 이러한 배수시스템은 방수층과 포장층 사이에 $2{\sim}3cm$의 두께로 박층의 배수층을 구성하는 것으로서 방수층의 내구성 확보와 골재 최대입경 10mm이하의 배수성 혼합물을 박층으로 시공하는 기술이 가장 중요한 사항이다. 이를 위해 본 연구에서는 먼저 NCAT 배합설계법을 바탕으로 10mm 이하 배수성 혼합물을 개발하였고, 다양한 실내시험을 통하여 배수성 혼합물이 모든 품질기준을 만족함을 확인하였다. 방수층의 경우 MMA(Methyl Methacrylate)계 방수제의 적용성을 평가하기 위하여 저온 휨 시험, 접착인장강도 시험 등의 시험을 실시하였고 모든 물성이 기준을 만족하였다. 본 연구에서 개발된 배수시스템의 현장시공성 및 공용성을 평가하기 위하여 고속도로의 1개소 교량에 시험시공을 실시하였다. 시공후 각 포장층 재료에 대한 품질확인 시험결과 모두 기준을 만족하였고 체류수가 원활히 배수되는 것을 확인할 수 있었다.

  • PDF

MODIS 지표 분광반사도 자료를 이용한 고품질 NDVI 시계열 자료 생성의 기법 비교 연구 (A comparative study for reconstructing a high-quality NDVI time series data derived from MODIS surface reflectance)

  • 이지혜;강신규;장근창;홍석영
    • 대한원격탐사학회지
    • /
    • 제31권2호
    • /
    • pp.149-160
    • /
    • 2015
  • 원격탐사 자료 기반의 식생지수 시계열 자료를 이용함에 있어서 가장 중요한 것은 구름이나 에어로졸에 의한 자료의 품질저하 문제이다. 이 연구에서는 MODIS09 지표 분광반사도 자료를 이용하여 구름영향에 의한 저품질 자료를 제거한 뒤 결손자료를 내삽, 평활하여 연속적인 Normalized Difference Vegetation Index (NDVI) 시계열 자료를 생산하였다. 구름에 의한 영향을 제거하기 위한 방법으로 MODIS 분광반사도 자료를 이용한 5가지의 구름탐지기법을 선정하여 비교, 평가하였다. 위성자료에서 제공하는 품질관리정보 (Quality Assessment, QA)에서 구름이라고 판단한 경우, MODIS09 Band 3 반사도가 10% 이상인 경우와 20% 이상인 경우, Cloud Detection Index (CDI)가 임계값 이상인 경우, 센서 천정각이 $32.25^{\circ}$ 이상인 경우를 각각 구름으로 판단하였다. 구름탐지로 인해 발생한 자료의 결손은 선형적 내삽 기법을 이용하여 보정한 뒤 Savitzky-Golay (S-G) 필터와 웨이브렛 변환을 각각 적용하여 평활하였다. 구름 탐지 기법은 10% 이상 Band 3 반사도 제거 기법(85%), Quality Control (QC) (82%), 20% 이상 Band 3 반사도 제거 기법(81%)의 순으로 높은 구름탐지율을 보였다. 웨이브렛 변환은 선형의 시계열 패턴을 얻을 수 있지만 원 자료의 최대값을 반영하지 못하는 반면 S-G 필터는 구름에 의한 신뢰도 낮은 값은 제거하면서도 NDVI 원 자료의 최대값을 유지하여 시계열 자료의 계절적 특성을 잘 보여주는 것을 확인하였다. 이 연구에서는 구름의 탐지, 결손 내삽, 평활 기법의 순차적인 자료처리기법을 적용하여 구름 영향을 제거한 고품질의 시계열 자료의 생산이 가능함을 확인하였다.

토모테라피 Hi-Art System의 영상유도 정확성 평가와 환자 피폭에 관한 연구 (Accuracy and radiation exposure from image-guidance in Tomotherapy Hi-Art System)

  • 장재욱;임현수;한만석;김용균;전민철
    • 디지털융복합연구
    • /
    • 제11권10호
    • /
    • pp.577-584
    • /
    • 2013
  • 토모테라피의 영상유도방사선치료는 환자의 자세재현성을 증가시켜 방사선치료의 정확성을 향상 시킬 수 있으나 그 정확성이 검증되어야 하며, MVCT 촬영에 의한 환자피폭이 발생할 수 있다. 본 연구에서 토모테라피의 영상유도 정확성은 1.0mm 이내로 매우 양호하게 측정되었으며, 선량은 각각 Fine(2mm) 3cGy, Normal(4mm) 1.5cGy, Corse(6mm) 1cGy로, 해상력은 Normal에서 비교적 양호하게 나타났다. 따라서 환자 피폭을 줄이기 위해서 Fine 보다 Normal을 선택하고 MVCT 촬영범위를 최소화하여 실시하는 것이 바람직하다.

대기 중 휘발성유기오염물질의 환경, 개인 및 인체 노출의 상관성 연구 (A Correlation Study between the Environmental, Personal Exposures and Biomarkers for Volatile Organic Compounds)

  • 조성준;신동천;정용
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권3호
    • /
    • pp.197-205
    • /
    • 2002
  • Volatile organic compounds (VOCs) are an important public health problem throughout the world. Many important questions remain to be addressed in assessing exposure to these compounds. Because they are ubiquitous and highly volatile, special techniques must be applied in the analytical determination of VOCs. Personal exposure measurements are needed to evaluate the relationship between microenvironmental concentrations and actual exposures. It is also important to investigate exposure frequency, duration, and intensity, as well as personal exposure characteristics. In addition to air monitoring, biological monitoring may contribute significantly to risk assessment by allowing estimation of absorbed doses, rather than just the external exposure concentrations, which are evaluated by environmental and personal monitoring. This study was conducted to establish the analytic procedure of VOCs in air, blood, urine and exhaled breath and to evaluate the relationships among these environmental media. The subjects of this study were selected because they are occupationally exposed to high levels of VOCs. Environmental, personal, blood, urine and exhalation samples were collected. Purge & trap, thermal desorber, gas chromatography and mass selective detector were used to analyze the collected samples. Analytical procedures were validated with the“break through test”, 'quot;recovery test for storage and transportation”,“method detection limit test”and“inter-laboratory QA/QC study”. Assessment of halogenated compounds indicted that they were significantly correlated to each other (p value < 0.01). In a similar manner, aromatic compounds were also correlated, except in urine sample. Linear regression was used to evaluate the relationships between personal exposures and environmental concentrations. These relationships for aromatic and halogenated are as follows: Halogen $s_{personal}$ = 3.875+0.068Halogen $s_{environmet}$, ($R^2$= .930) Aromatic $s_{personal}$ = 34217.757-31.266Aromatic $s_{environmet}$, ($R^2$= .821) Multiple regression was used to evaluate the relationship between exposures and various exposure deter-minants including, gender, duration of employment, and smoking history. The results of the regression model-ins for halogens in blood and aromatics in urine are as follows: Halogen $s_{blood}$ = 8.181+0.246Halogen $s_{personal}$+3.975Gender ($R^2$= .925), Aromatic $s_{urine}$ = 249.565+0.135Aromatic $s_{personal}$ -5.651 D.S ($R^2$ = .735), In conclusion, we have established analytic procedures for VOC measurement in biological and environmental samples and have presented data demonstrating relationships between VOCs levels in biological media and environmental samples. Abbreviation GC/MS, Gas Chromatography/Mass Spectrometer; VOCs, Volatile Organic Compounds; OVM, Organic Vapor Monitor; TO, Toxic Organicsapor Monitor; TO, Toxic Organics.

EPR/알라닌 선량계를 이용한 치료용 선형가속기 정도관리 활용 연구 (Research on the use of Therapeutic Linear accelerator Quality Control using EPR/alanine Dosimeter)

  • 김윤하;김효진;강영록;이동연
    • 한국방사선학회논문지
    • /
    • 제18권3호
    • /
    • pp.239-248
    • /
    • 2024
  • 방사선치료는 고에너지를 사용함으로 인체에 부작용이 발생할 수 있다. 이에 따라 적정 선량의 설정과 발생장치에서 만들어진 방사선에 대한 신뢰도를 확보하는 것이 중요하다. EPR/알라닌 선량평가는 물 동등성, 선량 응답 선형성과 낮은 페이딩 등의 장점이 있으므로 방사선치료 장비의 품질관리에서 유용하게 사용될 것으로 생각한다. 따라서 본 연구에서는 선형가속기 6 MV 에너지를 활용하여 알라닌의 질량에 따른 EPR/알라닌 선량평가의 신호와 선량반응곡선을 비교하였다. 조사된 알라닌 선량계의 EPR 신호를 통해 선량반응곡선과 1차 회귀방정식을 제작하였다. 이를 통해 질량에 따른 신호 크기와 선량반응곡선을 비교하고 선량반응곡선 측정 불확도를 통해 신뢰도를 확인하였다. 그 결과, 질량이 커짐에 따른 EPR 신호의 크기는 64.5 mg 기준으로 약 1.3배 증가하며, 선량반응곡선의 민감도도 커지는 것을 알 수 있었다. 측정 불확도는 5.84 ~ 8.93 % (신뢰구간 약 95 %, k=2)로 평가되었다. 본 연구를 통해 선형가속기의 품질보증과 품질관리에 EPR/알라닌 선량평가 시스템이 적용 가능할 것으로 생각된다.