• 제목/요약/키워드: QA/QC

검색결과 91건 처리시간 0.024초

동물병원의 방사선발생장치 정도관리에 대한 연구 (Quality Control of Diagnostic X-ray Units for Animal Hospital)

  • 김상우;이지훈;박예슬;임재동;성열훈
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 춘계학술대회
    • /
    • pp.231-237
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using quality assurance (QA) and quality control (QC) of diagnostic X-ray units. The surveys for QA/QC, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The QA/QC included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. As a result, 44.44% of reproducibility of dose exposure was proper, 81. 25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test.

  • PDF

울릉도 온실기체 관측자료를 이용한 배경대기 평균농도 산정 (An Estimation of Mean Background Concentrations of Greenhouse Gases Observed on Ulleungdo)

  • 임윤규;문윤섭;김진석;송상근;홍지형
    • 한국지구과학회지
    • /
    • 제33권1호
    • /
    • pp.32-38
    • /
    • 2012
  • 본 연구에서는 울릉도 온실기체 관측장비(CRDS)에서 관측된 $CO_2$$CH_4$ 농도를 정형화된 QA${\cdot}$QC 처리절차를 통해 온실기체 평균 배경대기 농도값으로 활용하기 위한 정확도를 향상시켰다. QA${\cdot}$QC 처리절차는 총 3단계로 구성되었다. 첫 번째는 관측자료의 시간별 평균값을 구하기 위한 물리적 한계검사, 기후범위 검사 및 1시간 측정 자료수가 50% 이하인 자료는 제외시키는 과정으로 이루어져 있다. 두 번째는 일평균자료 산출을 위한 단계검사, 앞뒤로 같은 값일 경우는 제외, 하루 중 관측횟수가 15회 이상 및 일관측 자료의 표준편차가 일표준편차 평균의 3배 이하인 자료만 허용하는 과정이다. 세 번째는 기후적 특성분석 활용을 위한 Curve-fitting methods를 이용한 FFT 적용단계이다. 이상의 QA${\cdot}$QC 절차에 의한 $CO_2$$CH_4$의 월평균농도 값을 안면도 지구대기감시센터 자료와 일본 료리 관측자료와 비교 분석한 결과 $CO_2$에 있어서는 울릉도 관측자료 누락에 의한 영향이 다소 크게 나타나 안면도 관측값이 배경대기 평균농도 값으로 유효하였고, $CH_4$는 안면도 보다 오히려 울릉도 관측값이 한반도 배경대기 평균농도 값으로 더 적절한 것으로 추정되었다.

해양환경공정시험기준 제정/개정(안) 작성과정 소개: 중금속과 유기물질 분석 중심으로 (The Restoration/Revision Processes of the Korean Standard Methods for Marine Environment: Heavy Metals & Organic Compounds)

  • 정용훈;이동기;양재삼
    • 한국해양학회지:바다
    • /
    • 제21권2호
    • /
    • pp.78-90
    • /
    • 2016
  • 본 보고는 2014년 수행된 해양환경공정시험기준의 제정/개정(안)작성의 전체과정에 대한 안내 보고이다. 제정/개정(안) 작성과정은 수요자 설문조사, 인증표준물질(CRM) 분석을 통한 QA/QC 확인절차, 전문가 자문회의 3단계로 수행되었다. 이번 제정/개정(안) 작성과정에서 다섯 가지 주요 개선방안은 다음과 같다. 첫째, 해양환경 특유의 시료채취, 운반, 보관, 및 전처리에 관한 상세한 내용이 추가되었고, 둘째, 유기물질의 항목별 분석방법에서 되도록 동일한 초자기구와 유기용매를 사용할 수 있도록 편의성을 추구하였으며, 셋째, 인증표준물질(CRM) 분석과정을 통하여 QA/QC 검정을 수행함으로써 신뢰성을 확보하였으며, 넷째, 다양하고 새로운 정량기기에 대한 사용방법을 기술함으로써 편의성을 제고하였고, 다섯째, 분석절차를 쉽게 기술함으로써 사용자의 범위를 넓혔다. 이런 노력을 통해 향후 기대효과는 첫째, 철저한 QA/QC 과정을 거침으로써 국제적인 수준의 신뢰성과 동등성을 확보하고, 둘째, 사용자의 폭을 넓힘으로써 국가표준으로서 신뢰성과 대표성을 갖도록 하였다. 이번 제정/개정(안)에 포함하지 못한 몇 가지 내용은 향후 관련기관과 협조를 통해 조속히 해결될 수 있을 것으로 기대한다.

해양환경 정도관리제도 운영에 대한 고찰 (The History and Development of the Marine Environment QA/QC (Quality Assurance/Quality Control) Management System)

  • 박미옥;박준건;김성길;김성수
    • 한국해양학회지:바다
    • /
    • 제26권3호
    • /
    • pp.185-200
    • /
    • 2021
  • 해양환경 정도관리제도는 자료의 신뢰성 확보와 측정·분석기관의 분석능력 향상을 위해 2010년부터 본격적으로 시행되었다. 시행부터 2020년까지 측정·분석기관이 정도관리제도에 참여한 누적 건수는 총 266건, 해양수산부에서 인증서를 발급한 건수는 182건, 현재까지 유효한 인증서는 42건이다. 정도관리 숙련도 평가를 위한 표준물질은 3개 분야에서 32항목이 개발되었으며, 해양환경측정망 운영, 해양오염영향조사, 해역이용영향평가, 해양심층수조사 및 어장환경조사 사업 등에서 주로 분석하는 영양염, 화학적산소요구량, 미량금속 등의 항목을 중심으로 개발되었다. 반면, 대부분의 사업에서 분석하는 해수의 수온, 염분 및 해저퇴적물의 PCBs, PAHs 등은 정도관리가 시행되고 있지 않아서 이 항목들에 대한 정도관리 확대가 필요한 시점이다. 현장 평가는 ISO/IEC 17025에 의해 평가 받은 실험실(162건)을 대상으로 품질시스템 평가 및 미흡사항을 분석하였다. 경영 및 기술요건에서는 직원들의 업무분장 미흡이 약 4.2%, 직원 교육 미흡이 약 8.7%로 취약하게 나타났다. 시험분야별로는 표준물질관리 미흡이 약 6.3%, 초자기구 세척 상태 등이 약 5.4%로 지적되었다. 미흡한 부분에 대한 문제점 및 개선점을 파악하여 제도를 지속적으로 보완해 나가야 할 것이다.

방사선치료에서의 품질보증을 위한 통계적공정관리의 활용 (Use of Statistical Process Control for Quality Assurance in Radiation Therapy)

  • 정광호
    • 한국의학물리학회지:의학물리
    • /
    • 제26권2호
    • /
    • pp.59-71
    • /
    • 2015
  • 품질보증의 목적은 공정의 품질을 유지하기 위하여 계통적인 오류를 최소화하는 것이다. 통계적공정관리는 2005년 이후 방사선치료분야에서도 이용되기 시작하였으며 품질보증의 패러다임을 바꾸어가고 있다. 통계적공정관리의 목적은 공정의 안정성을 관리한계 내에서 유지하며 변동의 양상도 감시하기 위한 것이다. 통계적공정관리는 방사선치료 품질보증 전 분야에 적용 가능하지만, 이를 제대로 활용하기 위해서는 통계적공정관리에 대한 지식이 필요하다. 본 논문에서는 통계적공정관리의 개념을 설명하고 방사선치료분야에서 이를 활용한 연구들을 소개하였다.

대기환경측정과 정도관리 (I)-원리와 방법론 (Air Quality Measurements and QC/QA (I) -Principles and Methodology)

  • 백성옥;김기현;허귀석
    • 한국대기환경학회지
    • /
    • 제20권2호
    • /
    • pp.237-249
    • /
    • 2004
  • With the increasing concern over the air quality degradation, there are growing demands to accurately and precisely measure air quality. In this article, the general principles and approaches were described to help aid proper evaluation of air quality. In order to introduce the basic approaches for conducting field/laboratory experiments and for interpreting experimental data sets, we explained all the common methodologies involved and provided some insights into the desirable protocols for air quality measurements.

PM10 채취와 PM10 조성물질의 실험실간 동시측정 비교 연구 (Interlaboratory Comparison for the Sampling and Chemical Species Measurement of PM10)

  • 서영화;이병규;정용삼;정영주;문종화;이길용;심상권;홍완;최한우;김기현
    • 한국대기환경학회지
    • /
    • 제15권4호
    • /
    • pp.485-493
    • /
    • 1999
  • This paper presents the results of the first interlaboratory comparison of ambient particles measurement conducted by 5 laboratories under the framework of Korean Society for Atmospheric Environment(KOSAE) on the May of 1998 in Seoul. Collection of particles less than 10$mu extrm{m}$(PM10) was carried out by two different types of PM10 sampler, and their concentration reported by three laboratories ranged from 36.2~56.05$\mu\textrm{g}$/㎥. Analyses of chemical composition of particles collected by each lab were performed by the destructive and nondestructive instrumental methods. Statistical analysis of the measurement results could not be carried out because a comprehensive QA/QC had not been applied before experiment. The importance of QA/QC as well as the performance of QA/QC for the measurement of PM10 was discussed in detail.

  • PDF

QA/QC Techniques for the Automated Hydrocarbon Monitoring Natwork in the UK

  • Rod Robinson;Tony andrews;David Butterfield;Paul Quincey
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제17권E1호
    • /
    • pp.25-33
    • /
    • 2001
  • This paper presents an overview of the UK Hydrocarbon Monitoring Network and summarises some of the lessons learnt from running and automated VOC monitoring network in th UK. The paper will describe the operation of the network and the Quality Control and Quality Assurance (QA/QC) procedures used to ensure that the data qality objectives are met. The provision of accurate measurements of ambient air pollutant concentrations is a valuable and high-profile service of Governments, assisting policy decisions and allowing members of the public to be well-informed. The need for such measurements has been increased in the UK by the National Air Quality Strategy and European Air Quality Directives, with the National Networks playing a central role in delivering the information. The Hydrocarbon Network provides measurements directly in support of monitoring requirements for benzene and 1,3-butadiene, and of 23 other hydrocarbon species important for their role in ozone and secondary particulate formation.

대기오염측정에 대한 정도관리의 필요성 - 1998년도 한국대기환경학회 측정분석분과회의 실험실간 비교분석사업 시행과 전개방향 (The Need for QA/QC in the Measurements of Airborne Pollutants - Conduction of and Directions towards an Interlaboratory Comparison Test in 1998 by the Measurement and Analysis Division of KOSAE)

  • 김기현;이강웅;김조천;서영화;이종해;허귀석
    • 한국대기환경학회지
    • /
    • 제15권1호
    • /
    • pp.63-69
    • /
    • 1999
  • To offer a general guideline for the quantitative analysis of airborne pollutants, we designed and conducted a comprehensive QA/QC test using two different strategic approaches, namely (1) field-based comparative measurement and (2) laboratory-based comparative analysis. The former task was performed to make meaningful comparison of combined errors occurring from both sampling and analytical techniques in the measurements of such components as: (1) criteria pollutants, (2) volatile organic compounds (VOCs), and (3) particulate matters with the associated metals and ions. The latter task was also conducted to compare various types of bias arising mainly from the laboratory analytical procedures of (1) gaseous standards of VOCs and (2) of aqueous standards of metals and ions. The concentration data derived from each of these two different types of major tasks were evaluated per chemical species categorized as above. While the very details of these studies are to be reported on an individual basis according to the above classification of the project, this paper is presented to provide an overview of the whole project - its aim and direction.

  • PDF