• Title/Summary/Keyword: Q angle

Search Result 245, Processing Time 0.024 seconds

Optimal response of conical tool semi angle in ductile metal sheets indentation and its governing mechanics

  • Nazeer, Malik M.;Khan, M. Afzal;Haq, A-Ul
    • Structural Engineering and Mechanics
    • /
    • v.16 no.1
    • /
    • pp.47-62
    • /
    • 2003
  • The nonlinear dependence aspect of various conical tool indentation parameters leading to an optimum tool semi angle value for easiest perforation is plotted and discussed explicitly in this work with the conclusion that tool angle has an optimum response towards most of the indentation parameters. Around this optimum angle, the aluminium sheets showed minimum fracture toughness as well as minimum work input to overcome the offered resistance. At the end, the mechanism leading to this phenomenon is presented with the conclusion that plastic flow dominates as the dimple semi cone angle reaches 35 and both pre and post plastic flow perforations lead the tool semi cone angle value towards this dimple cone semi angle of plastic flow initiation for its optimum performance. It is also concluded that specimen material failure is solely under tensile hoop stress and hence results into radial cracks initiation and propagation.

A NEW MODELLING OF TIMELIKE Q-HELICES

  • Yasin Unluturk ;Cumali Ekici;Dogan Unal
    • Honam Mathematical Journal
    • /
    • v.45 no.2
    • /
    • pp.231-247
    • /
    • 2023
  • In this study, we mean that timelike q-helices are curves whose q-frame fields make a constant angle with a non-zero fixed axis. We present the necessary and sufficient conditions for timelike curves via the q-frame to be q-helices in Lorentz-Minkowski 3-space. Then we find some results of the relations between q-helices and Darboux q-helices. Furthermore, we portray Darboux q-helices as special curves whose Darboux vector makes a constant angle with a non-zero fixed axis by choosing the curve as one of the types of q-helices, and also the general case.

Identification and Functional Analysis of a Major QTL and Related Genes for Tiller Angle in Rice Using QTL Analysis

  • Dan-Dan Zhao;Kyung-Min Kim
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.280-280
    • /
    • 2022
  • Tiller angle, defined as the angle between the main stem and its side tillers, is one of the main target traits selected inbreeding to achieve the ideal plant type and increase rice yield. Therefore, the discovery and identification of tiller angle-related genes can provide architecture and yield. In the present work, using QTL analysis hence a total of 8 quantitative trait loci (QTLs) were detected based on the phenotype data of tiller angle and tiller crown width in two years. Among them, four QTLs (qTA9, qCW9, qTA9-1, qCW9-1) were overlapped at marker interval RM6235-RM24288 on chromosome 9 with a large effect value regarded as stable major QTL. Twenty tiller angle-related genes were selected from the target region and the relative gene expression levels were checked in five compact type lines, five spreading type lines, and their parental lines. Finally, OsSA URq9 which belongs auxin-responsive SMALL AUXIN UP RNA (SAUR) protein family was selected as a target gene. Overall, this work will help broaden our understanding of the genetic control of tiller angle and tiller crown width, and this study provides both a good theoretical basis and a new genetic resource for the breeding of ideal-type rice.

  • PDF

Effect of Mulligan Taping and Flossing Bands on Q-angle and Lower Limb Muscular Activity in Men with Chronic Ankle Instability (멀리건 테이핑과 플로싱 밴드가 만성 발목 불안정성 남성 환자의 Q-각과 하지 근 활성도에 미치는 효과)

  • Jeong, Hyo-chang;Park, Se-jin;Yu, Seung-hun
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.17-24
    • /
    • 2021
  • Background: The study aimed to examine changes in muscle activity by measuring the Q-angle and lower extremity activity when going down the stairs, after the application of either Mulligan taping or flossing bands to patients with chronic ankle instability. Methods: A total of 19 men with chronic ankle instability in their 20s and 30s participated in the study. Participants were randomly divided into two groups: the Mulligan taping group (n = 9) and the flossing band group (n=10). The Mulligan taping group had three sets of Mulligan joint operations repeated 10 times, after which the Mulligan tape was applied. The flossing band group either performed functional activities or exercised for 2 minutes after flossing band application. After the application of either Mulligan taping or flossing bands, changes in the Q-angle and lower limb muscular activity while going down the stairs were measured and compared. Results: In the Mulligan taping group, the Q-angle significantly decreased from 13.63° to 12.7° during the step down. Similarly, the Q-angle of the flossing band group significantly decreased from 15.95° to 15.48° (p<.05). There was no difference in lower limb muscle activity between the two groups when going down the stairs. The muscle activity of the tibialis anterior significantly increased from 34.12% to 40.2%, and the difference between the two groups were statistically significant (p<.05). Conclusions: The study found that the application of Mulligan taping and flossing bands to patients with chronic ankle instability decreased the Q-angle and lower limb muscle activity when going down the stairs.

Characteristic Analysis of Single Phase Line-start Permanent Magnet Synchronous Motor Considering Circuit Parameters (단상 직립 기동형 영구자석 동기기의 회로정수에 따른 특성 해석)

  • 강규홍;홍정표
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.6
    • /
    • pp.262-270
    • /
    • 2003
  • In this paper, the characteristics of single-phase line-start permanent magnet synchronous motor driven by constant voltage are analyzed on d-q axis vector diagram and compared with that of current controlled motor. The coupled method of symmetrical coordinates and d-q axis voltage equation are applied to the analysis method like the analysis of single-phase induction motor. From the result of the analysis, it is seen that motors driven by constant voltage source have effects on not only the amplitude of current and torque but also current and current phase angle, so overall characteristics such as power factor and load angle are affected by circuit parameters. For precise analysis and design of single-phase line-start synchronous motor, its characteristics should be analyzed on d-q axis vector plan in consideration of the variation of circuit parameters.

The Change of Gait as Q-angle in Chronic Knee Osteoarthritis Disease (만성 무릎 퇴행성관절염 환자의 Q각 변화에 따른 보행의 변화)

  • Chae, Jung-Byung;Cho, Hyun-Rae;Hwa, Nam-Jin;Kim, Yong-Hun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.1
    • /
    • pp.71-79
    • /
    • 2010
  • Purpose : To investigate of gait change as Q-angle in chronic knee osteoarthritis patients. Methods : Participated osteoarthritis disease patients(n=16) and normal adults(n=16). gait measure was used by GaitRite and Q-angle measure was used by tape measur

The Relationship Between the Range of Hip Rotation and the Quadriceps Angle in Subjects With and Without Flat Foot

  • Lee, Keun-hyo;Chon, Seung-chul
    • Physical Therapy Korea
    • /
    • v.25 no.4
    • /
    • pp.19-26
    • /
    • 2018
  • Background: Alignment of the lower limb is an important factor, influencing balance and gait in kinematics and kinetics, in patients with and without a flat arched foot. Flat arched foot are associated with the range of motion (ROM) of the hip and alignments of the knee joints, is strongly influenced. Objects: The purpose of this research was to investigate the relationship between hip joint ROM and quadriceps angle (Q-angle), by dividing them into two groups according to the presence or absence of flat feet, using a navicular drop test (NDT) and resting calcaneal stance position (RCSP). Methods: Forty elderly patients were allocated to the experimental group (flat foot group, n1=20) or the control group (non-flat group, n2=20). Universal and digital goniometer, tractograph and tape measure were used to determine the related changes in the hip ROM, Q-angle, NDT and RCSP. Results: Data were analyzed using the Pearson correlation coefficients. Active internal ROM of the hip joint (right, r=.803, p<.001), (left, r=.951, p<.001) were highly correlated with NDT, and also, was moderately correlated with Q-angle (right, r=.562, p=.019), (left, r=.757, p<.001). Passive internal ROM of the hip joint (right, r=.742, p=.001), (left, r=.922, p<.001) were highly correlated with NDT, and also, was moderately correlated with RCSP (right, r=-.530, p=.029) and with Q-angle (right, r=.710, p=.001), (left, r=.698, p=.002) in the flat foot group. However, no strong correlation among the hip ROM, NDT, RCSP and Q-angle were found in the non-flat foot group. Conclusion: This research may provide evidence of the correlations between hip internal ROM and flat foot.

The Effects of Hip Angle on Muscle Activity of Quadriceps during Q-Setting Exercise (고관절 각도에 따른 대퇴사두근의 Q-setting 운동 시 근활성도에 미치는 영향)

  • Lee, Geoncheol;Kim, Jongsu;Kim, Sunghun;Kim, Myungkeun;Kim, Jiwon;Chu, Seolhui;Kim, Bora
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.1
    • /
    • pp.15-21
    • /
    • 2014
  • Purpose : The aim of this study was to find out differences between muscle activity of quadriceps according to hip angle. Method : 40 healthy adults produced maximum isometric muscle contraction of quadriceps femoris and each part of the quadriceps femoris were measured with a surface EMG in hip joint angle of $90^{\circ}$, $135^{\circ}$, $180^{\circ}$. Result : There was no significant difference between muscle activity of vastus medialis and lateralis according to hip angle. But there was significant difference in muscle activity of rectus femoris and the muscle activity was maximum at 135 degrees of hip angle. Conclusion : In conclusion, maximum muscle activation of rectus femoris is affected by hip angle, and the findings from this study may be helpful for physical therapists in selecting hip position when instructing patients to do Q-setting exercise. So, we suggest that patients perform Q-setting exercise at 135 degrees of hip angle for the best result.

Correlation Analysis of Body Parameters between Chuna Posture Analysis System and X-ray (추나체형진단기와 단순 방사선 검사로 측정된 신체 지표들간의 상관 분석)

  • Kim, Chang-Gon;Lee, Jin-Hyun;Min, Seon-Jeong;Kim, Byung-Sook;Song, Yung-Sun;Lee, Su-Kyung;Ko, Youn-Suk;Lee, Jung-Han
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.24 no.4
    • /
    • pp.177-185
    • /
    • 2014
  • Objectives This study analyzed the correlation between body parameters measured using X-ray and Chuna posture analysis system to determine their clinical value in diagnosing and evaluating skeletomuscular diseases. Methods X-ray and Chuna posture analysis system were performed for 105 patients to measure physical characteristics such as Interacromial angle, Pelvic obliquity angle, Structural leg length discrepancy (SLLD), Midpatella-midtalus angle (MMA) and Q-angle, Anterior head translation (AHT), Anterior superior iliac spine to posterior superior iliac spine angle (ASIS-PSIS angle), Interscapular angle, Scoliotic angle and Cobb's angle. Statistical analysis using statistical analysis techniques and Pearson correlation coefficients was performed to assess the body parameters obtained by X-ray and Chuna posture analysis system. Results Significant correlations were observed between the values for Interacromial angle, Pelvic obliquity angle, SLLD, MMA and Q-angle, AHT, ASIS-PSIS angle, Interscapular angle, Scoliotic angle and Cobb's angle obtained by X-ray and Chuna posture analysis system. Significant correlations were also observed between right MMA and left Q-angle as well as between left MMA and right Q-angle. Conclusions Chuna posture analysis system can be used instead of X-ray measure body parameters and perform posture analysis in clinical practice. This study's findings are expected to serve as a basis for further research on the clinical application of Chuna posture analysis system.

Effects of Squat Exercise Using Balls on the Gap Interval between Knees, Q-angle, Muscle Activity in Women with Genu-Varum (안굽이무릎을 가진 여성에게 볼을 이용한 스쿼트 운동이 무릎사이 간격과 Q각, 근 활성도에 미치는 효과)

  • Lee, Keoncheol;Han, Jiwon;Bae, Wonsik
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.2
    • /
    • pp.97-107
    • /
    • 2020
  • Purpose : The purpose of this study is to investigate the effect of squat exercise using a ball on the gap between knees and Q angle of a subject with a genu-varum, and to prove the effect, to provide a clinical basis for developing into a knee correction exercise program. Methods : As a result of posture measurement through GPS, 26 female with genu-varum with a knee length of 5 cm or more were studied. The group was randomly assigned to 13 squat exercise group using ball (experimental group) and 13 general squat exercise groups (control group). The experimental group placed the ball between both knees in a position where the distance between both feet was slightly wider than the shoulder width on a flat support surface, and fixed the ball, and then squat with the start signal. The control group squats without a ball. Each group performed three sets of exercise three times a week for six weeks. Before their exercise, after three and six weeks, EMG, GPS, digital goniometer measurement, the vastus medialis (VM), the vastus lateralis (VL), and the Q-angle were measured in the squat exercise posture. EMG was measured in squat exercise posture. Results : The distance between the knees was reduced. EMG is activated in group A, the group B experimental results showed the high activity of the VL. Q-angle had increased. But the experimental group increased more than the control group. Conclusion : We have confirmed through our experiments that the distance interval between the knees during squat exercises using a ball can be reduced. Furthermore, it would also be helpful to ensure the treatment of genu-varum.