• Title/Summary/Keyword: Putty

Search Result 65, Processing Time 0.025 seconds

Thickness Measurement of Adhesive Layer of Multilayer Using Power Cepstrum Technique (전력 켑스트럼 기법을 이용한 다층구조물 접착면의 두께측정)

  • Shin, Jin-Seob;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.26-30
    • /
    • 1997
  • In this paper, the thickness measurement method of adhesive layers of multilayers using power cepstrum signal processing technique has been proposed. The peak values for reflected signal from each layer have been separated by power cepstrum technique. Therefore, thickness of adhesive layers have been measured by the intervals of peak signal. In the experiment, the adhesive layers of 0.5mm-0.75mm thickness using epoxy(2-Ton and Plastic Steel Putty(A)) between the aluminum and the brass were formed. The adhesive layer thickness which is calculated with data of reflected signal by ultrasonic pulse-echo method was within error 1.34% of the measured values.

  • PDF

Effects of calcium silicate cements on neuronal conductivity

  • Derya Deniz-Sungur;Mehmet Ali Onur;Esin Akbay;Gamze Tan;Fugen Dagli-Comert;Taner Cem Sayin
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.2
    • /
    • pp.18.1-18.9
    • /
    • 2022
  • Objectives: This study evaluated alterations in neuronal conductivity related to calcium silicate cements (CSCs) by investigating compound action potentials (cAPs) in rat sciatic nerves. Materials and Methods: Sciatic nerves were placed in a Tyrode bath and cAPs were recorded before, during, and after the application of test materials for 60-minute control, application, and recovery measurements, respectively. Freshly prepared ProRoot MTA, MTA Angelus, Biodentine, Endosequence RRM-Putty, BioAggregate, and RetroMTA were directly applied onto the nerves. Biopac LabPro version 3.7 was used to record and analyze cAPs. The data were statistically analyzed. Results: None of the CSCs totally blocked cAPs. RetroMTA, Biodentine, and MTA Angelus caused no significant alteration in cAPs (p > 0.05). Significantly lower cAPs were observed in recovery measurements for BioAggregate than in the control condition (p < 0.05). ProRoot MTA significantly but transiently reduced cAPs in the application period compared to the control period (p < 0.05). Endosequence RRM-Putty significantly reduced cAPs. Conclusions: Various CSCs may alter cAPs to some extent, but none of the CSCs irreversibly blocked them. The usage of fast-setting CSCs during apexification or regeneration of immature teeth seems safer than slow-setting CSCs due to their more favorable neuronal effects.

Implementation of Man-made Tongue Immobilization Devices in Treating Head and Neck Cancer Patients (두 경부 암 환자의 방사선치료 시 자체 제작한 고정 기구 유용성의 고찰)

  • Baek, Jong-Geal;Kim, Joo-Ho;Lee, Sang-Kyu;Lee, Won-Joo;Yoon, Jong-Won;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Purpose: For head and neck cancer patients treated with radiation therapy, proper immobilization of intra-oral structures is crucial in reproducing treatment positions and optimizing dose distribution. We produced a man-made tongue immobilization device for each patient subjected to this study. Reproducibility of treatment positions and dose distributions at air-and-tissue interface were compared using man-made tongue immobilization devices and conventional tongue-bites. Materials and Methods: Dental alginate and putty were used in producing man-made tongue immobilization devices. In order to evaluate reproducibility of treatment positions, all patients were CT-simulated, and linac-gram was repeated 5 times with each patient in the treatment position. An acrylic phantom was devised in order to evaluate safety of man-made tongue immobilization devices. Air, water, alginate and putty were placed in the phantom and dose distributions at air-and-tissue interface were calculated using Pinnacle (version 7.6c, Phillips, USA) and measured with EBT film. Two different field sizes (3$\times$3 cm and 5$\times$5 cm) were used for comparison. Results: Evaluation of linac grams showed reproducibility of a treatment position was 4 times more accurate with man-made tongue immobilization devices compared with conventional tongue bites. Patients felt more comfortable using customized tongue immobilization devices during radiation treatment. Air-and-tissue interface dose distributions calculated using Pinnacle were 7.78% and 0.56% for 3$\times$3 cm field and 5$\times$5 cm field respectively. Dose distributions measured with EBT (international specialty products, USA) film were 36.5% and 11.8% for 3$\times$3 cm field and 5$\times$5 cm field respectively. Values from EBT film were higher. Conclusion: Using man-made tongue immobilization devices made of dental alginate and putty in treatment of head and neck cancer patients showed higher reproducibility of treatment position compared with using conventional mouth pieces. Man-made immobilization devices can help optimizing air-and-tissue interface dose distributions and compensating limited accuracy of radiotherapy planning systems in calculating air-tissue interface dose distributions.

  • PDF

Effect of Temporary Anterior Positioning Splint Using Putty Impression Material on Acute Closed Lock (급성 과두 걸림의 치료에서 퍼티 고무 인상재로 제작한 임시 전방위치장치의 적용)

  • Song, Ji-Hee;Kim, Ji-Hyun;Kwon, Jeong-Seung;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.4
    • /
    • pp.221-225
    • /
    • 2012
  • Disc dislocation without reduction, as known as closed lock, is a clinical condition in which the disc is dislocated from the condyle and does not return to normal position during condylar movement When the condition of disc dislocation without reduction is acute, the initial therapy should include an attempt to reduce or recapture the disc by manual manipulation. When patients report a history of being locked for 1 week or less, manual manipulation is usually successful. In patients with a longer history, success rate tends to decrease rapidly. If the disc has been successfully recaptured, placing an anterior positioning appliance is recommended to prevent clenching on the posterior teeth, which would likely redislocated the disc. But it is hard to make an appliance immediately in the clinic because it takes too much time. And making an appliance using self-curing acrylic resin is not very popular because of its discomfort by odor and working time. Also, if the patient has resin allergy or is under orthodontic treatment, or if it is impossible to control behavior of the patient, it has been restricted to make an appliance immediately. Therefore, to supplement this disadvantages, we tried to confirm about successful short term use of temporary anterior positioning splint made by using putty impression material after manual manipulation in this study.

An Analysis of the Characteristics of Paint for Preservation of Painted Works Exhibited in the Outdoor Sculpture Parks: Focusing on the Works Installed in Sculpture Parks in Jeollabuk-do Area (야외 조각 공원 전시 페인팅 작품의 보존을 위한 도료 특성 분석: 전북 지역 조각 공원 설치 작품 중심으로)

  • Oh, Seung-Jun;Wi, Koang-Chul
    • Journal of Conservation Science
    • /
    • v.36 no.5
    • /
    • pp.383-392
    • /
    • 2020
  • This study aimed to examine the characteristics of paint used for modern art works by conducting sectional observations, inorganic component analysis, and infrared spectroscopic analysis on the painted layers of 3 painted sculpture works exhibited in the Yongdam Dam Environmental Sculpture Park and Naejangsan Sculpture Park in the Jeollabuk-do area. The observations indicate that the cross section is composed of various layers of 2-3 folds, the thickness of the layers was uneven at approximately 23-150 ㎛, and putty was used for plate treatment prior to painting. Inorganic component analysis results show that putty containing calcium carbonate, iron oxide, diatomite, and titanium dioxide was used for the putty layer. It is also assumed that paint mixed with green (Cr2O3), blue(sodaliteblue), red(chromered), andwhite(TiO2) colors were used for the painted layers. As a result of infrared spectroscopic analysis to confirm the types of paint, it is estimated that the paint was mixed with polyester resin and an extender.

A comparision of TISSH and PuTTY (TTSSH와 PuTTY의 비교 분석)

  • 강민정;강민수;박연식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.418-422
    • /
    • 2002
  • As Unix based server including Linux are increased steadily, MS group users who want to connect these servers are increased. There were lots of connection using telnet for a while, but there are increased connection using "TTSSH or PUTTY" which get used free since "secure shell"(SSH) appeared recently. This paper compare TTSSH & PuTTY′s characters and using method, and propose remote-access tool which improve TTSSH.

  • PDF

A Study on Oxygen Consumption during Occupational Activities Performance of Adult Hemiplegia (성인 편마비 환자의 작업수행 중 산소소모량에 대한 연구)

  • Oh, Kyung-Ah;Yoon, Seoung-Ic;Min, Kyung-Ok;Kim, Yoon-Shin;Oh, Duck-Won;Chon, Seung-Chul
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.1
    • /
    • pp.21-28
    • /
    • 2008
  • The purposes of this study are to quantify energy expenditure by measuring oxygen consumption while performing occupational therapy activities most commonly used for adult hemiplegia patients, to recommend a optimal dosage of exercise by comparing energy expenditure according to the recovery stage, and to suggest a precaution in the treatment of patients with cardiac disorders. According to Brunnstrom recovery stages in hand function, subjects were allocated to group I(3rd and 4th Brunnstrom recovery stages) and group II(5th and 6th Brunnstrom recovery stages). Outcome measures included oxygen consumption, energy expenditure rate, and heart rate during each activity and in recovery period after the activity. Occupational activities including sanding activity, putty activity, and skateboard activity were carried out for all patients. In sanding and putty activities, there were significant differences of oxygen consumption and energy expenditure during the activity between groupⅠandⅡ(p<0.05), but there were not significant differences of oxygen consumption, energy expenditure and heart rate in the recovery period(p>0.05). In skateboard activity, there were no significant differences in oxygen consumption, energy expenditure and heart rates between the two groups during the activity and in the recovery period(p>0.05). The findings indicates that cardiovascular demands for basic activities usually peformed for a treatment may be depended on the physical recovery of patients with hemiplegia. Therefore, therapeutic activities for patients should be selected with the great care.

  • PDF

WETTABILITY OF POLYVINYLSILOXANE IMPRESSION MATERIALS AND IMPROVED STONE MATERIALS (부가중합 실리콘 인상재 및 모형재의 젖음성에 관한 비교 연구)

  • Cho, Lee-Ra;Chung, Kyung-Ho;Kim, Kyoung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.191-199
    • /
    • 2000
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined the impression quality in clinical condition and the wettability of impression and die material. Four commercially available addition silicone impression material (Express, Examix, Contrast, Perfect) and three die materials (Die-Keen, Vel-Mix, Fuji-Rock) were studied. A total of 50 putty/wash and heavy body/wash impressions of wet intact permanent molar teeth were examined for definition of the gingival sulcus reproduction and then classified in quality ranking. The percentage of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned epoxy resin casts from the impressions and clinically measured sulcus depths, The same impression materials were used to produce 3 groups of die stone casts form void entrapment die had been exposed to milk. Voids in the impression body and stone casts ere counted under a stereoscopic microscope. From the experiment, the following results were obtained : 1. Sulcus reproduction ability of additional silicone impression material were diminished in order of Express, Examix, Perfect, Contrast. The significant difference was found between Perfect and other material. Heavy body/wash combination was superior In putty/wash method n Perfect impression material. 2. In direct observation, Contrast showed least void in impression body but correlations ere not found between sulcus reproduction and void production. 3. In void entrapment laboratory test, wettability were diminished in order of Examix, Contrast, Express, Perfect. Clinical impression recording seems not to correlate with laboratory test. 4. The wettability of die material to impression material was not different in Express, Examix, Contrast. But, in Perfect, Die-Keen had superior wettability to others.

  • PDF

A STUDY ON THE ACCURACY OF SEVERAL DENTAL ELASTOMERIC IMPRESSION MATERIALS (수종의 치과용 탄성인재의 정확도에 관한 연구)

  • Choi, Myoung-Soo;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.850-868
    • /
    • 1996
  • The accuracy and dimensional stability of impression materials are one of the most important factors for successful prosthodontic treatment. The purpose of this study was to evaluate the accuracy of several dental elastomeric impression materials used widely and clinically : Impregum-$F^{(R)},\;Permlastic^{(R)},\;Silascon^{(R)},\;Perfect^{(R)},\;Xantopren^{(R)}$. There have been many studies to evaluate the accuracy of impression materials. But it has not been decided yet, which method was most suitable for the evaluation of the accuracy. In this study, two resin teeth, #15 & 25, were prepared with rounded shoulder margin and 90 degree cavosurface angle. For the polysulfide rubber and polyether, the custom tray was made at least 24 hours prior to impression taking. For the silicone rubber materials, putty/wash impression technique was applied in taking impressions. Marginal openings of the castings on the master dies and prepared resin teeth were measured under stereomicroscope. The results were statistically analyzed and compared between tested impression materials. The results were as follows ; 1. In the overall accuracy of impression materials, polyether was the most accurate one, followed by polysulfide, additional silicone and condensation silicone. 2. On the first model pouring, condensation silicone had the largest discrepancies and there was significant difference compared to the other impression materials. 3. Polysulfide had the least discrepancies in the first model pouring, but showed larger discrepancies in the immediate second pouring than the first pouring. 4. On the immediate second pouring, the discrepancy of polyether was shown to be the smallest, while the largest one was additional silicone. 5. Polyether and polysulfide rubber using custom impression trays showed superior accuracy to silicone rubber, putty/wash impression technique.

  • PDF

Evaluation of Flexural strength and surface porosity of three indirect composite resins (3종의 간접수복용 복합레진의 굴곡강도 비교 및 표면관찰)

  • Kim, Jun-Tae;Park, Jin-Young;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.9-16
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate flexural strength, composite surface and fractured surface of three different indirect composite resins. Methods: Fifteen bar-shaped specimens ($25mm{\times}2mm{\times}2mm$) were fabricated for each FL group (Flow type and Light curing) and PLP group (Putty type and Light, Pressure curing) and PL group (Putty type and Light curing) according to manufacturer's instructions and ISO 10477. Fabricated specimens were stored in the distilled water for 24 hours at the temperature of $37^{\circ}C$. Three-point bending strength test was performed to measure flexural strength using universal testing machine at a crosshead speed of 1mm/min (ISO 10477). Surface and fractured surface of specimens were observed by digital microscope. Results were analyzed with Kruskal-wallis tests (${\alpha}=0.05$). Results: Mean (SD) of three different indirect composite resins were 83.38 (6.67) MPa for FL group, 139.90(16.53) MPa for PLP group and 171.72(16.74) MPa for PL group. Flexural strength were statistically significant (p<0.05). Differences were not observed at fractured surface among three groups. However, many pores over $100{\mu}m$ were observed at PL group in observing surface of specimen. Conclusion: Flexural strength of composite resins was affected by second polymerization method and content of inorganic filler.