• Title/Summary/Keyword: Purification plant

Search Result 487, Processing Time 0.031 seconds

A Study on the Application of AI-Based Composite Sensor in WTP (수도사업장에서의 AI 기반 복합센서 적용 방안 연구)

  • Hong, Sung-taek;An, Sang-byung;Kim, Kuk-il;Cho, Hyun-sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.41-42
    • /
    • 2021
  • The Green New Deal policy was established to innovate the government's energy consumption structure, establish a third basic energy plan to strengthen the global competitiveness of the energy industry, and realize a carbon neutral society due to the increased need for transition to a low-carbon economy. Waterworks such as drinking water, water purification plant, and pressurization plant analyze control factors and energy consumption status by process to improve energy management efficiency and reduce energy usage through the 4th industrial revolution. Ultimately, we want to realize net-zero water purification plant.

  • PDF

Anaerobic Digester Gas Purification for the Fuel Gas of the Fuel Cell (연료전지 연료가스인 하수처리장 소화가스정제)

  • Lee, Jong-Gyu;Jun, Jae-Ho;Park, Kyu-Ho;Choi, Doo-Sung;Park, Jae-Young
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.2
    • /
    • pp.164-170
    • /
    • 2007
  • The Tancheon wastewater treatment plant(WWTP) in Seoul using anaerobic digestion to reduce the outlet sludge produces anaerobic digester gas which contains 65% $CH_4$ and 35% $CO_2$. The gas purification equipment was installed and operated to use Anaerobic Digester Gas(ADG) as a fuel for molten carbonate fuel cell(MCFC). The processes consist of the desulfurizer and the adsorption tower to remove $H_2S$ and siloxane in the gas. The gas purification equipment removed virtually over 95% of $H_2S$ and over 99% of siloxane. Results has demonstrated that the fuel cell can produce electrical output and hot water with negligible air emissions of CO, NOx and $SO_2$. The site provides the first opportunity in Korea for demonstrating Molten carbonate fuel cell(MCFC) which the digester gas was applied to the fuel gas.

The control system of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank (오수/합병정화조의 배출물 제어시스템 연구)

  • 박주식;김건호;오지영;임총규;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2001.11a
    • /
    • pp.193-202
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which ate the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxygen demanding amount has to control. Each mom must be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

Process Technologies of Reforming, Upgrading and Purification of Anaerobic Digestion Gas for Fuel Cells (연료전지에의 적용을 위한 혐기성 소화가스의 정제, 고질화 및 메탄개질 기술)

  • BAE, MINSOO;LEE, JONGYEON;LEE, JONGGYU
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.2
    • /
    • pp.135-143
    • /
    • 2016
  • Biogas is a renewable fuel from anaerobic digestion of organic matters such as sewage sludge, manure and food waste. Raw biogas consists mainly of methane, carbon dioxide, hydrogen sulfide, and water. Biogas may also contain other impurities such as siloxanes, halogenated hydrocarbons, aromatic hydrocarbons. Efficient power technologies such as fuel cell demand ultra-low concentration of containments in the biogas feed, imposing stringent requirements on fuel purification technology. Biogas is upgraded from pressure swing adsorption after biogas purification process which consists of water, $H_2S$ and siloxane removal. A polymer electrolyte membrane fuel cell power plant is designed to operate on reformate produced from upgraded biogas by steam reformer.

The Development using Fuzzy Control of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank (퍼지제어를 통한 오수-합병정화조의 오니 측정 및 제어시스템에 관한 연구)

  • 박주식;박윤규;강경식
    • Journal of the Korea Safety Management & Science
    • /
    • v.3 no.4
    • /
    • pp.53-63
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which are the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxyzen demanding amount has to control. Each room mus be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

Assessment of the Applicability of Convergence Technology for Reducing and Blocking Pollution Loads to Rivers through the Utilization of Waterfront Spaces (수변공간을 활용한 오염부하 저감 및 차단 융복합 기술의 하천 적용성 평가)

  • Kim, Bong Kyun;Seo, Dae Seuk;Oh, Jong Min;Park, Jae-Ro
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.238-246
    • /
    • 2016
  • Water purification facilities utilizing three technologies - a detention pond, an artificial wetland and an ecological revetment - were installed in waterfront spaces, including river embankments and watersides that have so far been left neglected, and then their water purification levels were analyzed in this study. The water purification facilities were found to show average removal efficiencies of 48.6% in suspended solid (SS), 30.5% in biochemical oxygen demand (BOD), 18.4% in total nitrogen (T-N) and 27.3% in total phosphorus (T-P) during rainfall. The removal efficiencies during non-rainfall were 33.2% in SS, 28.6% in BOD, 13.7% in T-N and 17.3% in T-P. These results showed that the water purification facilities using a detention pond, an artificial wetland and an ecological revetment can be used as a useful natural water purification technology in in waterfront spaces.

Determination of coagulant input rate in water purification plant using K-means algorithm and GBR algorithm (K-means 알고리즘과 GBR 알고리즘을 이용한 정수장 응집제 투입률 결정 기법)

  • Kim, Jinyoung;Kang, Bokseon;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.6
    • /
    • pp.792-798
    • /
    • 2021
  • In this paper, an algorithm for determining the coagulant input rate in the drug-injection tank during the process of the water purification plant was derived through big data analysis and prediction based on artificial intelligence. In addition, analysis of big data technology and AI algorithm application methods and existing academic and technical data were reviewed to analyze and review application cases in similar fields. Through this, the goal was to develop an algorithm for determining the coagulant input rate and to present the optimal input rate through autonomous driving simulator and pilot operation of the coagulant input process. Through this study, the coagulant injection rate, which is an output variable, is determined based on various input variables, and it is developed to simulate the relationship pattern between the input variable and the output variable and apply the learned pattern to the decision-making pattern of water plant operating workers.

Purification and Characterization of ATPase and Phosphatase of Light Membrane Vesicles Isolated from Cucurbita pepo (Cucurbita pepo에서 분리한 Light Membrane Vesicle의 ATPase와 Phosphatase의 정제 및 특성)

  • 오승은
    • Journal of Plant Biology
    • /
    • v.33 no.4
    • /
    • pp.325-332
    • /
    • 1990
  • Light membrane vesicles were isolated from the zucchini hypocotyl by floatation on ficoll density gradients and the proteins were solubilized with Triton X100. Three ATP-hydrolyzing enzymes were partially purified by ion-exchange and gel filtration chromatography and isoelectric focusing. There are plasma membrane-type ATPase whose activity was inhibited by vanadate but not by nitrate, tonoplast-type ATPase which was sensitive to nitrate but insensitive to vanadate and one having a phosphatase activity with a pI value different from that of an acid phosphatase. A fraction was obtained after DEAE-ion-exchange chromatography crossreacting with polyclonal antibodies against Ca2+ -ATPase from human erythrocytes.

  • PDF