• Title/Summary/Keyword: Purification method

Search Result 852, Processing Time 0.026 seconds

A Crystal Type Conversion Study of HNS(Hexanitrostilbene) (HNS(Hexanitrostilbene)의 결정 전환 연구)

  • 강정부;구본탁;이경희;임영권
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.216-224
    • /
    • 2001
  • HNS(hexanitrostilbene), one of the most important heat resistant explosive was recrystallized using organic solvent, nitric acid and dual solvent system of acetonitrile-toluene. The purification, analysis, type conversion method and its physical properties are described.

  • PDF

3 Types of Set Point Controllers for Biological Wastewater Treatment Process

  • Kim, D.;Lee, I.B.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.97.1-97
    • /
    • 2001
  • One of the main problems to constitute control method on biologically oriented wastewater purification processes, e.g. activated sludge process, sequential batch reactor, rotating bio-disk contactor, etc. is that it is hard to control the target component directly. For instance, while biochemical oxygen demand, suspended solids, and chemical oxygen demand are the key components to check the process performance, one may not control them directly since they are the results of microbial activities related to numerous physiochemical factors. Therefore controllers for bioprocess should be designed to make favorable condition for microorganisms´ living, e.g. dissolved oxygen level favorable, mixed liquor suspended solids concentration suitable ...

  • PDF

Quantitative Analysis of Eleutherosides B and E Using HPLC-ESI/MS (HPLC-ESI/MS를 이용한 Eleutheroside B와 E의 정량)

  • Choi, Young-Hae;Kim, Jin-Woong
    • Korean Journal of Pharmacognosy
    • /
    • v.33 no.2 s.129
    • /
    • pp.88-91
    • /
    • 2002
  • Liquid-chromatography coupled with electrospray-ion trap mass spectrometry was applied to the analysis of the eleutherosides B and E in the Eleutherococcus senticosus cortexes. The optimum ESI/MS results were obtained in the positive ion mode using extracted ion chromatogram targeting Na-adduct molecular ion of each compound. This method allowed rapid and simple gradient separation of underivatized eleutherosides B and E without pre-purification steps at very low concentration.

Measurement and Correlation of Hinokitiol Solubility in Supercritical Carbon dioxide (초임계 이산화탄소에서 히노키치올의 용해도 측정과 예측)

  • Shin, Moon-Sam
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.489-492
    • /
    • 2011
  • Supercritical fluid technology has been an alternative for purification and separation of biological compounds in cosmetic, food, and pharmaceutical products. Solubility information of biological compounds in supercritical fluids is essential for choosing a supercritical fluid processes. The equilibrium solubility of hinokitiol was measured in supercritical carbon dioxide with a static method in the pressure range from 8 to 40 MPa and at temperatures equal to 313.2, 323.2 and 333.2 K. The experimental data were correlated well by Peng.Robinson equation of state and quasi-chemical nonrandom lattice fluid model.

  • PDF

Magnetic Force Control Technique for Recycling and Environmental Preservation

  • Nishijima, Shigheiro
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.4
    • /
    • pp.1-4
    • /
    • 2012
  • The applicability of the two types of magnetic separation system, high gradient magnetic separation (HGMS) and Magneto Archimedes method were studied considering the magnetic susceptibility of targeted substances. It was noted that the combination of the two methods can control the almost all the substances, paramagnetic and diamagnetic in addition to ferromagnetic substances. The principle of the methods was given and the conceput of the magnet force control technology is discussed. The practical applications of the technique were introduced together with the new application of HGMS.

Effect on Corrosion Characteristics of SS 400 Steel by Alkali Water pH from Electrolysis of City Water (수돗물의 전기분해에 의해서 생성된 알카리수의 pH가 SS 400강의 부식특성에 미치는 영향)

  • Moon, Kyung-Man;Ryoo, Hae-Jeon;Kim, Yun-Hae;Jeong, Jae-Hyun;Baek, Tae-Sil
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.248-255
    • /
    • 2017
  • Many rivers and seas have been affected by environmental contamination. Therefore, city water supplies often require a high-degree purification treatment to provide safe drinking water. However, in order to achieve a high-degree purification treatment, a large amount of chlorine has to be added to sterilize city drinking water. The added chlorine reacts chemically with water and forms hypochlorous and chlorine ions. The hypochlorous ionizes with hypochlorous ions and hydrogen ions. As a result, the city water contains a large amount of chlorine ion. As such, when city water is used with domestic boilers, many kinds of heat exchangers, and the engines of vehicle and ships, there are often corrosion problems. In this study, alkali water was electrochemically made by electrolysis of city water, and corrosion properties between alkali and city water were investigated with an electrochemical method. Most of the chlorine ions are thought to not be contained in the alkali water because the alkali water is created in the cathodic chamber with an electrolysis process. In other words, the chlorine ion can be mostly removed by its migration from a cathodic chamber to an anodic chamber. Moreover, the alkali water also contains a large amount of hydroxide ion. The alkali water indicated relatively good corrosion resistance compared to the city water and the city water exhibited a local corrosion pattern due to the chlorine ion created by a high-degree purification treatment. In contrast, the alkali water showed a general corrosion pattern. Consequently, alkali water can be used with cooling water to inhibit local corrosion by chlorine ions in domestic boilers, various heat exchangers and the engine of ships and for structural steel in a marine structure.

Development of an exclusive column method for 82Sr/82Rb generator using a 100 MeV proton linear accelerator of KOMAC

  • Kye-Ryung Kim;Yeong Su Ha;Sang-Pil Yoon;Yeon-ji Lee;Yong-Sub Cho;Hyeongi Kim;Sang-Jin Han;Jung Young Kim;Kyo Chul Lee;Jin Su Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.7 no.2
    • /
    • pp.119-125
    • /
    • 2021
  • 82Sr for 82Rb generator was produced through the irradiation of the proton beam on the nat.RbCI target at the target irradiation facility installed at the end of the Rl-dedicated beamline of the 100 MeV proton linear accelerator of KOMAC (Korea Multi-purpose Accelerator Complex). The average current of the proton beam was 1.2 µA for irradiation time of 150 min. For the separation and purification of the 82Sr from nat.RbCI irradiated, Chelex-100 resin was used. The activities of 82Sr in the irradiated nat.RbCI target solution and after purification were 45.29 µCi and 43.4 µCi, respectively. The separation and purification yield was 95.8%. As an adsorbent to be filled in the generator for 82Sr adsorption hydrous tin oxide was selected. The adsorption yield of 82Sr into the generator adsorbent was > 99 %, and the total amount of 82Sr adsorbed to the generator was 21.6 µCi as of the day of the 82Rb elution experiment. When the elution amount was 22 mL, the maximum82Rb elution yield was 93.3%, and the elution yield increased as the flow rate increased. After the eluted 82Rb was filled in the correction phantom of the small PET for animals, a PET image was taken. The image scan time was set to 5 min, and the phantom PET image was successfully obtained. As results of impurity analysis on eluted 82Rb using ICP-MS, nat.Rb stable isotopes that compete in vivo of 82Rb were identified as undetected levels and were determined to be No-Carrier-Added (NCA).

Impurity analysis and acid leaching purification of silica minerals (실리카광물의 산침출 정제와 불순물 분석법 연구)

  • Lee, Kil Yong;Yoon, Yoon Yeol;Cho, Soo Young;Chae, Young-Bae
    • Analytical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.516-523
    • /
    • 2007
  • Purification of silica mineral has been investigated by acid leaching of pulverized silica. A series of studies has been carried out on the effect of leaching silica powder as a function of the leaching time at the constant temperature of $80^{\circ}C$ in oxalic acid, aqua regia, and two mixed acids of HF/HCl, $HF/HNO_3$. The impurities of silica and leachantes were measured by neutron activation analysis (NAA), inductively coupled plasma atomic emission spectrometry (ICP-AES), atomic absorption spectrometry, x-ray fluorescence (XRF) method and wet analysis (WA). Certain metals, such as sodium, calcium, iron, aluminium and titanium, have been found in concentrations of hundreds or even thousands of mg/kg. Comparison of purification processes of silica and analytical methods of impurities in the silica was conducted in this study.

Methods for the Extraction of DNA from Water Samples for Polymerase Chain Reaction

  • Jung, Jae-Sung;Lee, Young-Jong
    • Journal of Microbiology
    • /
    • v.35 no.4
    • /
    • pp.354-359
    • /
    • 1997
  • Methods for the extraction of DNA from water sample were approximated. Four different procedures of DNA extraction were carried out with pellets obtained from centrifugation of 4 liter water samples. The recovery efficiency and purity of DNA extracted by each method from different sources were compared. DNA yield varied with extraction methods, Method I, which involves enzymatic and freeze-thaw lysis steps and phenol and phenol-chloroform purification of extracted nucleic acid, showed a significantly higher yield and purity than the other methods. The use of glass beads in the DNA extraction methods improved the purity of DNA suitable for PCR. Bovine serum albumin in the PCR reaction mixture was useful in reducing inhibitory effects of contaminants. The efficiency of an extraction method was determined by the detection of the aer of Aeromonas hydrophila with PCR. The lower limit of detection of A. hydrophila from seeded tap water was 2 CFU/ml in PCR when method I was used for DNA preparation.

  • PDF