• Title/Summary/Keyword: Pure Tone

Search Result 177, Processing Time 0.027 seconds

Remote Patient Monitoring System for Diagnostic Pure-tone Audiometry (순음 청력검사를 위한 원격진단 모니터링 시스템)

  • Lee, Kang-Ho;Kwon, Yeong-Eun;Kwon, Ohwon
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.289-293
    • /
    • 2019
  • This paper presents a remote patient monitoring system for diagnostic pure-tone audiometry. A pure-tone audiometer was developed for basic hearing screening; its performance was evaluated according to international standards in terms of linearity, accuracy, and total harmonic distortion. Pure-tone audiometry has a maximum hearing level of 104.9 dB HL that is comparable with other commercial products. The audiometer shows satisfactory linearity with a deviation of ${\pm}0.4dB$, an accuracy of ${\pm}0.025%$, and a total harmonic distortion (THD) of 0.21%. The remote patient monitoring systems include remote control devices based on wide area network (WAN) connections and an audiometer connected in series. Through experimentation, we successfully performed real-time diagnostic communication without delay in transferring audiometric data. This system is expected to supply domestic equipment in the audiometric market and to improve the quality of life of patients in non-clinical environments.

A Comparison of Pure-Tone Thresholds to the Pre and Post Fogging after Refractive Correction in Normal Eyes (굴절교정된 정상안에서 운무 전후에 따른 순음청력역치의 비교)

  • Cho, Soo-Jin;Joo, Seok-Hee;Lee, Koon-Ja;Choi, In-Sil;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.89-93
    • /
    • 2009
  • Purpose: To purpose of this study was the pure-tone audimetry changes to compare pre and post fogging after visual correction in normally hearing adults. Methods: The estimated that no ocular and audiolar disesases, we selected (male: 30, female: 20) in corrected visual acuity over the 1.0 eye. Pre and post fogging were measured using the pure-tone audimetry. Results: To compared fre and post fogging, fre fogging was higher than fre fogging. The take value were just about every kind of Hz but 200 Hz, respectively which were statistically significant (p<.05). Low Hz area in 250 and 500 Hz were 6.8${\pm}$8.4dBHL, 4.3${\pm}$6.6dBHL, there is not all the difference between any other area, 2000 Hz in the middle Hz area was 0.8${\pm}$4.5dBHL. Conclusions: The study presents different results of measurements in within normal limits. we thought that pure-tone thresholds to the pre and post fogging after refractive correction in normal adults and would be used basic data.

  • PDF

Development of Automatic Calibration System for PC-Based Pure Tone Audiometer (PC 기반 순음청력검사기를 위한 자동보정시스템 개발)

  • Kim, Jin-Dong;Kang, Deok-Hun;Song, Bok-Deuk;Lee, Il-Woo;Kong, Soo-Keun;Kwon, Soon-Bok;Jeon, Gye-Rok;Shin, Bum-Joo;Wang, Soo-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2586-2594
    • /
    • 2010
  • A pure tone audiometer should be able to produce both pure tone and masking noise with exact sound pressure level and frequency. For such purpose, it is unavoidable to periodically calibrates pure tone audiometer. However, manual acoustic calibration requires not only attention but also long time. It is possible to execute automatically calibration using software if it is PC-based pure tone audiometer. In this paper, we describe auto-calibration software for PC-based pure tone audiometer and dedicated sound level meter which has been implemented upon PC by us. To verify auto-calibration module, we examine whether output of PC-based audiometer calibrated through auto-calibration of this paper satisfies RETSPL of IEC or not.

IoT based Pure Tone Audiometer with Software Platform Compatibility (IoT 기반의 소프트웨어 플랫폼 호환성을 갖는 순음청력 검사기)

  • Kang, Sung Ho;Lee, Jyung Hyun;Kim, Myoung Nam;Seong, Ki Woong;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.2
    • /
    • pp.261-270
    • /
    • 2018
  • Hearing-impaired people are increasing rapidly due to the global aging trend. Early detection of hearing loss requires an easy-to-use audiometry device for the public. Existing audiometry systems were developed as PC-based, PDA-based, or smartphone apps. These devices were often dependent on specific software platforms and hardware platforms. In this paper, we tried to improve software platform compatibility by using cross platform, and tried to implement IoT-based pure tone audiometry device which does not require sound pressure level correction due to hardware differences. Pure tone audiometry is available in a variety of ways depending on the type of hearing loss and age. Using the IoT-based audiometry device implemented in this paper, it will be possible for an app developer who lacks hardware knowledge to easily develop an app with various scenarios for hearing screening. The results of this study will contribute to overcoming the software and hardware dependency in the development of IoT-based healthcare device.

Effectiveness of Computer-Animated Pure Tone Audiometry for Screening (애니메이션을 이용한 순음청력선별검사 도구의 효용성에 대한 연구)

  • Kim, Young-Min;Lee, Moo-Kyung
    • Phonetics and Speech Sciences
    • /
    • v.2 no.3
    • /
    • pp.151-156
    • /
    • 2010
  • The purpose of this study was to develop a computer-animated pure tone audiometry for screening (CAPTAS) for toddler and to determine its validity and reliability. The CAPTAS utilizes an animated cartoon story producing visual and auditory stimuli. The intensities were 40 dB, 60 dB, 80 dB. The frequencies were 500 Hz, 1000 Hz, 2000 Hz, and 4000 Hz. The subjects were 20 (9 males and 11 females) severely hearing impaired children. As a result, The correlation coefficient between mean hearing threshold of children who were able to perform PTA and average hearing threshold of CAPTAS was performed and it revealed CAPTAS's high validity. And to verify the reliability of the re-test, all children had the CAPTAS and repeated it periodically. The result confirmed the reliability.

  • PDF

A Study on the Comparison between Domestic and Foreign Evaluation Method of Aircraft noise (국내 항공기소음 평가방법과 외국 평가방법의 비교연구)

  • Kim, Bong-Suk;Kim, Deuk-Sung;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.229-229
    • /
    • 2006
  • WECPNL(Weighted Equivalent Continuous Perceived Noise Level) which designated currently in Domestic 'The Stanrd Method of Measuring Noise and Vibration' is composed of different factor with WECPNL that published in ICAO. Domestic WECPNL is concerned in application of $L_{MAX}$ measurement. On the other hand, ICAO's WECPNL is based on EPNL that includes factors of the pure tone correction and the duration time. NNI and NEF also are each based on PNL and EPNL. Because a military aircraft noise, especially, has the pure tone of high frequency and the irregular duration, it seems to be undesirable to estimate aircraft noise for using Domestic WECPNL. Therefore, this study was performed to detect a flaw of Korean WECPNL, through comparison of the trend of each other aircraft noise index by using equivalent rawdata.

  • PDF

A Relationship of Tone, Consonant, and Speech Perception in Audiological Diagnosis

  • Han, Woo-Jae;Allen, Jont B.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.5
    • /
    • pp.298-308
    • /
    • 2012
  • This study was designed to examine the phoneme recognition errors of hearing-impaired (HI) listeners on a consonant-by-consonant basis, to show (1) how each HI ear perceives individual consonants differently and (2) how standard clinical measurements (i.e., using a tone and word) fail to predict these differences. Sixteen English consonant-vowel (CV) syllables of six signal-to-noise ratios in speech-weighted noise were presented at the most comfortable level for ears with mild-to-moderate sensorineural hearing loss. The findings were as follows: (1) individual HI listeners with a symmetrical pure-tone threshold showed different consonant-loss profiles (CLPs) (i.e., over a set of the 16 English consonants, the likelihood of misperceiving each consonant) in right and left ears. (2) A similar result was found across subjects. Paired ears of different HI individuals with identical pure-tone threshold presented different CLPs in one ear to the other. (3) Paired HI ears having the same averaged consonant score demonstrated completely different CLPs. We conclude that the standard clinical measurements are limited in their ability to predict the extent to which speech perception is degraded in HI ears, and thus they are a necessary, but not a sufficient measurement for HI speech perception. This suggests that the CV measurement would be a useful clinical tool.

Acoustic Masking Effect That Can Be Occurred by Speech Contrast Enhancement in Hearing Aids (보청기에서 음성 대비 강조에 의해 발생할 수 있는 마스킹 현상)

  • Jeon, Y.Y.;Yang, D.G.;Bang, D.H.;Kil, S.K.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.1 no.1
    • /
    • pp.21-28
    • /
    • 2007
  • In most of hearing aids, amplification algorithms are used to compensate hearing loss, noise and feedback reduction algorithms are used and to increase the perception of speeches contrast enhancement algorithms are used. However, acoustic masking effect is occurred between formants if contrast is enhanced excessively. To confirm the masking effect in speeches, the experiment are composed of 6 tests; test pure tone test, speech reception test, word recognition test, pure tone masking test, formant pure tone masking test and speech masking test, and for objective evaluation, LLR is introduced. As a result of normal hearing subjects and hearing impaired subjects, more making is occurred in hearing impaired subjects than normal hearing subjects when using pure tone, and in the speech masking test, speech reception is also lower in hearing impaired subjects than in normal hearing subjects. This means that acoustic masking effect rather than distortion influences speech perception. So it is required to check the characteristics of masking effect before wearing a hearing aid and to apply this characteristics to fitting curve.

  • PDF

The Effect of Workplace Noise on the Hearing Threshold of Dental Technicians

  • Lee, Ju Hee;Lee, Hye Ran;Lee, Og Kyoung
    • Biomedical Science Letters
    • /
    • v.20 no.4
    • /
    • pp.201-208
    • /
    • 2014
  • This study was conducted to investigate hypoacusis due to workplace noise among dental technicians. Pure tone audiometry, impedance audiometry and heart rate variability were measured for 60 dental technicians and office workers in D city from July to November 2013, and a survey on the effects of noise was conducted. SPSS 19.0 was used for statistical analysis. In the result for threshold of pure tone audiometry, the average hearing threshold of left ears in the air conduction (AC) test showed a statistically significant decrease (P=0.019) among dental technicians, who are frequently exposed to workplace noise. The hearing threshold in the AC test for each frequency was significantly different between the two groups at 125 Hz (P=0.012) in right ears and at 1 kHz (P=0.022), 2 kHz (P=0.040), and 8 kHz (P=0.018) in left ears. Dental technicians who had worked for 16 years or longer had a significantly higher incidence of hypoacusis in the right ear (P=0.030) and in the left ear (P=0.010). In impedance audiometry showed a tympanometry result of type A in both the dental technician group and the office worker group.

The Clinical Study of Three Patients Hospitalized Due To Sudden Sensorineural Hearing Loss (돌발성 난청 환자 3례에 대한 임상적 고찰)

  • Kwon, Kang;Choi, Kwan-Ho;Park, Jae-Young;Owi, Jong-Sung;Park, Hee-Soo;Park, Young-Hwan
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.15 no.2
    • /
    • pp.156-168
    • /
    • 2002
  • Backgrounds : sudden sensorineural hearing loss is defined as a disease that has abrupt onset of sensorineural hearing loss without definite cause. In some cases, this disease cause tinnitus, vertigo, headache addition to hearing loss. In traditional oriental medicine, sudden sensorineural hearing loss is could be diagnosed as deficiency of Yang-Gi(陽氣). Objects & Methods : This study is clinical observation about three sudden sensorineural hearing loss cases. For diagnosing in these cases, pure tone audiometry was used. For treatment, acupuncture, herbal-medicine and moxibustion therapy were used. Results & Conclusions : as follows. 1. Generally, in this disease, the shorter the whole period from the time that occurs to the time that starts to treat is, the more the results are better. The research shows that short-term case is more efficient than the other long-term two cases in the aspects of symptoms and pure tone audiometry . 2. In making a diagnosis of sudden sensorineural hearing loss and measuring the effect, subjective symptoms generally correspond to the improvement of pure tone audiometry, but not completely. Therefore, in treating patients, the doctor must consider these both aspects and keep the balance.

  • PDF