• Title/Summary/Keyword: Pure Efficiency Change

Search Result 50, Processing Time 0.035 seconds

The estimation of the productivity in adjacent water fisheries (연근해어업 업종별 생산성 추정에 관한 연구)

  • Park, Cheol-Hyung
    • The Journal of Fisheries Business Administration
    • /
    • v.45 no.1
    • /
    • pp.63-77
    • /
    • 2014
  • This study is to estimate the recent changes in total factor productivity of 15 Korean adjacent water fisheries based on Malmquist productivity indices. The study adopted both input and output oriented productivity measures utilizing a hyperbola distance function. In addition to this point, the study also calculated the 95% confidence interval for the various components of the productivities in order to access the statistical significance of estimates using 2000 times of re-sampling process through the smoothed bootstraping. The results of the study showed us that there was 18% reduction in the overall total factor productivity during the study period from 2007 to 2011, which turned out to be 5% of annual decrease in productivity. The study found that the main reason of this decrease in total productivity is about 22% downward shift of a fisheries production function due to recent conditions of a devastated fishing ground. When we evaluated the statistical significance of changes in technical efficiency combining both pure technical and scale efficiency based on the 95% confidence intervals, we could not find any evidence of changes in those components of total factor productivity. When we accessed the productivity of the each of 15 adjacent water fisheries methods, only the large danish seine fisheries showed us about 7% increase in productivity. Even though the large trawling and the large tow-boat trawling revealed no changes in productivity, all of the other 12 fisheries suffered the decreases in productivities.

Enhancing Breakdown Strength and Energy Storage Efficiency of Glass-Pb(Zr,Ti)O3 Composite Film (유리-PZT 혼합 후막의 절연 파괴 전압 및 에너지 저장 효율 향상)

  • Kim, Samjeong;Lim, Ji-Ho;Jeong, Dae-Yong
    • Korean Journal of Materials Research
    • /
    • v.31 no.10
    • /
    • pp.546-551
    • /
    • 2021
  • To improve ferroelectric properties of PZT, many studies have attempted to fabricate dense PZT films. The AD process has an advantage for forming dense ceramic films at room temperature without any additional heat treatment in low vacuum. Thick films coated by AD have a higher dielectric breakdown strength due to their higher density than those coated using conventional methods. To improve the breakdown strength, glass (SiO2-Al2O3-Y2O3, SAY) is mixed with PZT powder at various volume ratios (PZT-xSAY, x = 0, 5, 10 vol%) and coating films are produced on silicon wafers by AD method. Depending on the ratio of PZT to glass, dielectric breakdown strength and energy storage efficiency characteristics change. Mechanical impact in the AD process makes the SAY glass more viscous and fills the film densely. Compared to pure PZT film, PZT-SAY film shows an 87.5 % increase in breakdown strength and a 35.3 % increase in energy storage efficiency.

A Study on the Modeling of Ship Energy System Using Bond Graph (Bond Graph를 이용한 선박 에너지 시스템 모델링 연구)

  • Sang-Won Moon;Won-Sun Ruy
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.61 no.1
    • /
    • pp.19-28
    • /
    • 2024
  • Environmental regulations are becoming more stringent in response to climate change, especially concerning marine pollution caused by ship emissions. Large ships are adjusting by integrating technologies to reduce pollutant emissions and transitioning to eco-friendly fuels such as low-sulfur oil and LNG. However, small ships face space constraints for installing LNG propulsion systems and the risk of power depletion with pure electric propulsion. Consequently, there's growing interest in researching hybrid propulsion methods that combine electricity and diesel for smaller vessels. Hybrid propulsion systems utilize diverse energy sources, requiring an effective method for evaluating their efficiency. This study proposes employing Bond graph modeling to comprehensively analyze energy dynamics within hybrid propulsion systems, facilitating better understanding and optimization of their efficiency. Modeling of the ship's energy system using Bond graphs will be able to provide a framework for integrating various energy sources and evaluating their effects.

Design of closed-loop nitrogen Joule-Thomson refrigeration cycle for 67 K with sub-atmospheric device

  • Lee, C.;Lee, J.;Jeong, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.1
    • /
    • pp.45-50
    • /
    • 2013
  • Closed-loop J-T (Joule-Thomson) refrigeration cycle is advantageous compared to common open loop $N_2$ decompression system in terms of nitrogen consumption. In this study, two closed-loop pure $N_2$ J-T refrigeration systems with sub-atmospheric device for cooling High Temperature Superconductor (HTS) power cable are investigated. J-T cooling systems include 2-stage compressor, 2-stage precooling cycle, J-T valve and a cold compressor or an auxiliary vacuum pump at the room temperature. The cold compressor and the vacuum pump are installed after the J-T valve to create sub-atmospheric condition. The temperature of 67 K is possible by lowering the pressure up to 24 kPa at the cold part. The optimized hydrocarbon mixed refrigerant (MR) J-T system is applied for precooling stage. The cold head of precooling MR J-T have the temperature from 120 K to 150 K. The various characteristics of cold compressor are invstigated and applied to design parameter of the cold compressor. The Carnot efficiency of cold compressor system is calculated as 16.7% and that of vacuum pump system as 16.4%. The efficiency difference between the cold compressor system and the vacuum pump system is due to difference of enthalpy change at cryogenic temperature, enthalpy change at room temperature and different work load at the pre-cooling cycle. The efficiency of neon-nitrogen MR J-T system is also presented for comparison with the sub-atmospheric devices. These systems have several pros and cons in comparison to typical MR J-T systems such as vacuum line maintainability, system's COP and etc. In this paper, the detailed design of the subcooled $N_2$ J-T systems are examined and some practical issues of the sub-atmospheric devices are discussed.

Application of Change Vector Analysis for Monitoring Geomorphological Change Using Remote Sensing Data (원격탐사 자료를 이용한 지형변화 관측을 위한 변화벡터법 적용연구)

  • Won, Joong-Sun;Yoo, Hong-Rhyong
    • Economic and Environmental Geology
    • /
    • v.28 no.4
    • /
    • pp.405-414
    • /
    • 1995
  • An algorithm for monitoring geomorphological change using remote sensing data is investigated and tested using two LANDSAT TM data sets acquired over the Kyunggi Bay on April 15 1986 and September 22 1992, respectively. The algorithm exploits change vector analysis and tasseled cap transform. Although change vector analysis is effective for change detection, efficiency is decreased as the number of variables are increased. In this algorithm, we overcome the problem by utilizing the tasseled cap transform which can reduce six bands of LANDSAT TM data into only two components called Brightness and Greenness. The test results demonstrate that the algorithm is very effective in monitoring small-scaled changes over coastal area as well as significant changes in geomorphology. The resulting change vector image, however, is more sensitive to the changes occurred by human activities than by pure geological processes mainly because of relatively short time interval between two LANDSAT TM data sets.

  • PDF

Predictive Instantaneous Control of inverter for UPS (UPS용 예측 순시제어형 인버터)

  • Kim, B.J.;Kim, J.H.;Cho, J.H.;Kim, J.S.;Lee, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.237-239
    • /
    • 1995
  • The inverter for UPS system is required to satisfy pure sinusoidal output voltage with very low THD(Total Harmonic distortion). This paper proposes a TMS320c31 digital signal processor based predictive instantaneous control scheme of inverter. The proposed scheme is able to satisfy the conditions; high capability, high efficiency, low audible noise and robustness of inverter. The transient state characteristics of proposed inverter has been improved. in case of power failure or recovery, nonlinear load, sudden load change or parameters variations. Finally, the performance of the proposed inverter is shown and discussed by simulation and experiment.

  • PDF

Game-Theoretic Optimization of Common Control Channel Establishment for Spectrum Efficiency in Cognitive Small Cell Network

  • Jiao Yan
    • International journal of advanced smart convergence
    • /
    • v.13 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Cognitive small cell networks, consisting of macro-cells and small cells, are foreseen as a promising candidate solution to address 5G spectrum scarcity. Recently, many technological issues (such as spectrum sensing, spectrum sharing) related to cognitive small cell networks have been studied, but the common control channel (CCC) establishment problem has been ignored. CCC is an indispensable medium for control message exchange that could have a huge significant on transmitter-receiver handshake, channel access negotiation, topology change, and routing information updates, etc. Therefore, establishing CCC in cognitive small cell networks is a challenging problem. In this paper, we propose a potential game theory-based approach for CCC establishment in cognitive radio networks. We design a utility function and demonstrate that it is an exact potential game with a pure Nash equilibrium. To maintain the common control channel list (CCL), we develop a CCC update algorithm. The simulation results demonstrate that the proposed approach has good convergence. On the other hand, it exhibits good delay and overhead of all networks.

The Comparison of Productivity Change Gap of Public Hospitals and Private Hospitals in Korea (공공병원과 민간병원의 생산성 격차 비교)

  • Yang, Dong-Hyun
    • Journal of Digital Convergence
    • /
    • v.11 no.10
    • /
    • pp.203-215
    • /
    • 2013
  • This study calculated meta Malmquist indices and their bootstraped estimates and then decomposed them into technical efficiency change(TEC), technology change(TC), pure technology catch up(PTCU), frontoer catch up(FCU), using annual data set of general hospitals from year 2007 to 2011 collected by Korean Hospital Association and then analyzed productivity change and technology gap of Korean general hospitals. The results and implications were as follows below. First, public general hospitals showed higher meta technical efficiencies than private general hospitals while exhibited lower technology gap ratio which meant a few large private general hospitals led the whole general hospitals. Second, group productivity of private general hospitals increased larger than public general hospitals due to the differences of PTCU rather than FCU. But, there was no statistically significant differences for technical efficiency, productivity change, technology gap. Thus, public general hospitals played the same role as the private general hospitals in terms of the number of patients treated. But, considering financial hardships of public general hospitals, public hospitals needed to share and learn medical and managerial skills of the best practice of private general hospitals.

Performance Analysis of a Steam Injected Gas Turbine Combined Heat and Power System Considering Turbine Blade Temperature Change (터빈 블레이드 온도 변화를 고려한 증기분사 가스터빈 열병합발전 시스템의 성능해석)

  • Kang, Soo Young;Kim, Jeong Ho;Kim, Tong Seop
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.6
    • /
    • pp.18-24
    • /
    • 2012
  • This study simulated the operation of a steam injected gas turbine combined heat and power (CHP) system. A full off-design analysis was carried out to examine the change in the turbine blade temperature caused by steam injection. The prediction of turbine blade temperature was performed for the operating modes suggested in the previous study where the limitation of compressor surge margin reduction was analyzed in the steam injected gas turbine. It was found that both the fully injected and partially injected operations suggested in the previous study would cause the blade temperature to exceed that of the pure CHP operation and the under-firing operation would provide too low blade temperature. An optimal operation was proposed where both the turbine inlet temperature and the injection amount were modulated to keep both the reference turbine blade temperature and the minimum compressor surge margin. The modulation was intended to maintain a stable compressor operation and turbine life. It was shown that the optimal operation would provide a larger power output than the under-firing operation and a higher efficiency than the original partially injected operation.

Efficiency and Productivity of Seven Large-sized Shipbuilding Firms in Korea (국내 대형조선업계의 효율성 및 생산성 분석)

  • Park, Seok-Ho
    • Journal of Korea Port Economic Association
    • /
    • v.26 no.4
    • /
    • pp.188-206
    • /
    • 2010
  • Data Envelopment Analysis(DEA) is an operations research-based method for measuring the performance efficiency of decision units that are characterized by multiple inputs and outputs. DEA has been applied successfully as a performance evaluation tool in many fields. However, it has not been extensively applied in the shipbuilding industry. This paper applied the input-oriented DEA model, and Malmquist indices to the 7 shipbuilding firms to measure the efficiency and productivity changes during the period of 2004 to 2009. The Malmquist indices will be decomposed into three components such as pure efficiency change, scale efficiency change, and technical change. The empirical results show the following findings. First, the DEA findings indicate that main source of inefficiency is scale rather than pure technical. Second, the Malmquist indices show that an overall decrease in productivity.