• 제목/요약/키워드: Puncture resistance

검색결과 17건 처리시간 0.024초

Early Detection of Infiltration Induced in the Veins of Pig's Ear and Human's Forearm By Using Bioimpedance: Pilot Study

  • Kim, Jaehyung;Hwang, Youngjun;Kim, Gunho;Jeong, Ihn Sook;Jeon, Gyerok
    • 한국멀티미디어학회논문지
    • /
    • 제21권1호
    • /
    • pp.34-44
    • /
    • 2018
  • An early detection of intravenous (IV) infiltration is essential to minimize the injuries during infusion therapy, which is one of the most important tasks for nurses in nursing settings. We report that bioelectrical impedance analysis is useful in the early detection of infiltration at puncture sites. When infiltration was intentionally induced in the vein of a pig's posterior ear, impedance parameters (R, $X_C$, $C_m$) showed significant differences before and after infiltration. In particular, the relative resistance ($R/R_{BI}$) decreased significantly at infiltration and then slowly decreased. This indicates that the vein in pig's ear is thin and the amount of surrounding subcutaneous tissue, and hence the infiltrated solution accumulates slowly after infiltration. However, when infiltration was induced in the vein of human's forearm, the relative resistance at 20 kHz decreased gradually over time. In the $R-X_C$ graph, the positions in the case of infiltration induced in the pig' ear shifted rapidly before and after infiltration, whereas the positions in the case of infiltration induced in the human's forearm moved gradually during infiltration. Our findings suggest that the impedance parameters (R, $R/R_{BI}$, $X_C$, R vs. $X_C$, and $C_m$) are effective indicators to detect the infiltration early in a non-invasive and quantitative manners.

Comparison of Infiltration Induced in Veins of Rabbit's Ear and Human's Forearm by Using Bioelectrical Impedance: Pilot Study

  • Kim, Jae-Hyung;Hwang, Young-Jun;Kim, Gun-Ho;Shin, Beum-Joo;Kim, Yong-Jin;Lee, Eun-Joo;Jeon, Gye-Rok
    • 센서학회지
    • /
    • 제26권5호
    • /
    • pp.306-313
    • /
    • 2017
  • An early detection of infiltration in veins is essential to minimize the injuries caused during infusion therapy, which is one of the most important tasks for nurses in clinical settings. We report that bioelectrical impedance analysis is useful in the early detection of infiltration at puncture sites. When infiltration was intentionally induced in the vein of a rabbit's ear, impedance parameters showed significant difference before and after infiltration. In particular, the relative resistance at 20 kHz in the vein of rabbit's ear reduced largely at infiltration, decreased slowly, and then stayed at a constant value. This indicates that the vein in the ear of the rabbit is small, and hence the infiltrated intravenous (IV) solution no longer accumulates after 3 minutes of infiltration. However, when infiltration was induced in the vein of a human's forearm, the relative resistance at 20 kHz decreased gradually over time. In the $R-X_c$ graph, the positions in infiltration induced in the rabbit's ear rapidly shifted before and after infiltration whereas the positions in infiltration induced in the human's forearm changed gradually during infiltration. Our findings suggest that bioelectrical impedance analysis is an effective method to detect the infiltration early in a noninvasive and quantitative manners.

경막외강 카테터 삽입 시 삽입 길이와 감각이상의 빈도 (Incidence of Paresthesia Related to the Insertion Length of Catheter during the Epidural Catheterization)

  • 임준구;김영재;조재흥;이상은;김영환;임세훈;이정한;이근무;정순호;최영균;신치만
    • The Korean Journal of Pain
    • /
    • 제20권1호
    • /
    • pp.50-53
    • /
    • 2007
  • Background: Continuous epidural catheterization is a popular and effective procedure for postoperative analgesia. However, continuous epidural catheterization has associated complications such as venous puncture, dural puncture, subarachnoid cannulation, suboptimal catheter placement, and paresthesia because the tip of the epidural catheter touches thenerves of the dura in the epidural space. In this study, we compared the incidence of paresthesia in two different lengths of epidural catheter insertion. Methods: One hundred women undergoing gynecologic or orthopedic surgery were enrolled in this prospective, double-blinded, randomized study. All patients were randomly divided into two groups based on the insertion length of the epidural catheter 2 cm (group A) or 4 cm (group B). A Tuohy needle was inserted in the lumbarspinal region with a bevel directed cephalad by use of the median approach, and then the epidural space was confirmed by the loss of resistance technique with air. While the practitioner inserted an epidural catheter into the epidural space, a blind observer checked for paresthesia or withdrawal movement. Results: In 97 included patients, 30.6% of the patients in group A (n = 49) had paresthesia, versus 31.3% in group B (n = 48). Withdrawal movements were represented in 2% and 6% of the patients in group A and group B, respectively. There was no difference in the incidence of paresthesia and withdrawal movement between the two groups. Conclusions: There is no clear relationship for the incidence of catheter-related paresthesia according to the catheter length inserted into the epidural space for epidural analgesia.

THE EFFECTS OF SEALING ON THE PLASMA-SPRAYED OXIDE-BASED COATINGS

  • Kim, Hyung-Jun;Sidoine Odoul;Kweon, Young-Gak
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.53-58
    • /
    • 2002
  • Electrical insulation and mechanical properties of the plasma sprayed oxide ceramic coatings were studied before and after the sealing treatment of the ceramic coatings. Plasma sprayed A1$_2$O$_3$-TiO$_2$ coating as the reference coating was sealed using three commercial sealants based on polymer. Penetration depth of the sealants to the ceramic coating was evaluated directly from the optical microscope using a fluorescent dye. It is estimated that the penetration depth of the sealants to the ceramic coating is from 0.2 to 0.5 mm depending on the sealants used. The preliminary test results with a DC puncture tester imply that the dielectric breakdown voltage mechanism of plasma sprayed ceramic coatings has been determined to be a corona mechanism. Dielectric breakdown voltage of the as-sprayed and as-ground samples have shown a linear trend with regard to the thickness showing an average dielectric strength of 20 kV/mm for the thickness scale studied. It is also shown that grinding the coating before sealing and adding fluorescent dye do not agent the penetration depth of sealants. All of the microhardness, two-body abrasive wear resistance, bond strength, and surface roughness of the ceramic coating after the sealing treatment are improved. The extent of improvement is different from the sealants used. However, three-point bending stress of the ceramic coating after the sealing treatment is decreased. This is attributed to the reduced micro-crack toughening effect since the cracks propagate easily through the lamellar of the coating without crack deflection and/or branching after the sealing treatment.

  • PDF

The impact fracture behaviors of CFRP/EVA composites by drop-weight impact test

  • Go, Sun-Ho;Kim, Hong-Gun;Shin, Hee-Jae;Lee, Min-Sang;Yoon, Hyun-Gyung;Kwac, Lee-Ku
    • Carbon letters
    • /
    • 제21권
    • /
    • pp.23-32
    • /
    • 2017
  • A drop weight impact test was conducted in this study to analyze the mechanical and thermal properties caused by the changes in the ratio of carbon fiber reinforced plastic (CFRP) to ethylene vinyl acetate (EVA) laminations. The ratios of CFRP to EVA were changed from 10:0 (pure CFRP) to 9:1, 8:2, 6:4, and 5:5 by manufacturing five different types of samples, and at the same time, the mechanical/thermal properties were analyzed with thermo-graphic images. As the ratio of the CFRP lamination was increased, in which the energy absorbance is dispersed by the fibers, it was more likely for the brittle failure mode to occur. In the cases of Type 3 through Type 5, in which the role of the EVA sheet is more prominent because it absorbs the impact energy rather than dispersing it, a clear form of puncture failure mode was observed. Based on the above results, it was found that all the observation values decreased as the EVA lamination increased compared with the CFRP lamination. The EVA lamination was thus found to have a very important role in reducing the impact. However, the strain and temperature were inversely propositional.

LPS로 급성 염증을 유발한 동물에 대한 용담초 추출물의 면역조절 효과 (Immune regulation effects of Gentianae Radix extract in LPS-induced acute inflammatory mice)

  • 이효정;승윤철;이명선
    • 대한본초학회지
    • /
    • 제33권2호
    • /
    • pp.79-84
    • /
    • 2018
  • Objective : The immune enhance is the main focus of current society that to increase resistance to invasion by pathogenic species of bacteria in body, stimulate the immune system and possibly protect against cancer or inflammatory disease. The present study aimed to evaluate the effect of Gentianae Radix extract on immune regulation in a LPS-induced mice model of acute inflammation. Methods : Gentianae Radix extract was administered orally at doses of 200 mg/kg/day or 400 mg/kg/day for 2 weeks before a intraperitoneally injection of LPS (1 mg/kg of 0.9% saline). After LPS-intraperitoneal injection 3 hours, blood was collected by cardiac puncture under ether anaesthesia from all animals, for the immune regulate efficacy verification based on blood or serum biomarkers (i.e., immune cells, cytokine, $PGE_2$, ROS, and $LTB_4$) analysis. Results : Compared to the control mice, the Gentianae Radix extract treatments significantly increased the count of immune cells (i.e., wite blood cell, neutrophils, and monocyte), and significantly reduced the lymphocyte. In addition, the Gentianae Radix extract treatments significantly decreased the pro-inflammatory cytokine (i.e., $IL-1{\beta}$, IL-6, and $TNF-{\alpha}$), and significantly increased IL-10 of anti-inflammatory cytokine. Furthermore, the Gentianae Radix extracts treatments significantly increased the levels of $PGE_2$ and significantly decreased the levels of ROS, and $LTB_4$. Conclusions : The results indicate that Gentianae Radix extract alleviated acute inflammatory reaction though regulation of immune meditor. Thus, Gentianae Radix extract may raw material of development a health food and medicine option for the immune enhance.

Subcutaneous Emphysema and Inflammation of the Neck after Tracheal Puncture by an Intubating Stylet

  • Jung, Gul;Byun, Woo-Mok;Lim, Hyung-Jun;Kim, Jong-Gyun;Kwak, Dong-Min;Lee, Deok-Hee;Kim, Sae-Yeon;Song, Sun-Ok;Seo, Il-Sook;Jee, Dae-Lim;Kim, Heung-Dae;Park, Dae-Pal
    • Journal of Yeungnam Medical Science
    • /
    • 제24권2호
    • /
    • pp.344-350
    • /
    • 2007
  • 한 41세 남자 환자가 충수돌기염 절제술을 받기 위하여 전신마취를 받았다. 삽관을 위해 후두경으로 보자, 난해한 기도삽관이 예상되어 유도자를 사용하였다. 기도삽관 중 돌출된 유도자가 기도를 손상시켰으며, 이에 의해 목에서부터 상부종격동까지의 피하기종과 목의 염증성 종창이 생겼다. 환자는 호흡곤란과 관련된 증상을 보이지 않아 호흡기의 손상을 의심하기 어려웠고, 주 증상이었던 염증성 종창에 초점을 두게 되어 진단에 차질을 빚었으나, 환자는 대증치료로 회복하였다. 유도자를 사용하여 기관내 삽관을 하는 경우 유도자의 위치를 재점검하여 유도자에 의한 기도 손상을 유발하지 않도록 유념해야 할 것이다.

  • PDF