• 제목/요약/키워드: Pumping test

검색결과 303건 처리시간 0.021초

직결식 펌프의 수격현상 (Waterhammer for In-line Booster Pump)

  • 김상균;이계복;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제8권6호
    • /
    • pp.7-14
    • /
    • 2005
  • The waterhammer occur when the pumps are started or stopped for the operation or tripped due to the power failure, and the hydraulic transients take place as a result of the sudden change in velocity. Several times, the field tests of the waterhammer were carried out for Pangyo booster pumping station. Pangyo pumping station was installed with the booster pumps of 6 sets and the in-line pumps of 2 sets. The in-line pumps are additionally needed to the surge suppression device so that the pumping station acquire the safety and reliability for the pressure surge.

현장적용 초유동 콘크리트의 펌프압송 전후 단위수량 변화 특성 (Properties of Water Content Variances in Ultra High Flowing Concrete Before and After the Pumping Operation)

  • 김경민;유재강;신홍철;최종원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.401-404
    • /
    • 2006
  • This study is the part of the investigation of the state of the art in ultra high flowing concrete (UHFC), applied in practical field construction, in order to develop the technology for improving workability. This paper includes a brief introduction of water content variance properties in UHFC before and after the pumping operation. Test showed that water content in all parameters decreased after the pumping. This is due to the increase of an absorption ratio of coarse aggregate by the pressure of the pumping operation. thus decreasing the water content. Therefore it should be considered to find out the possibility, which can improve the workability, suffering from over viscosity by the lower water content, in field construction.

  • PDF

여러 가지 양수시험분석방법 적용을 통한 목천지역 암반대수층의 수리지질학적 특성 (Hydrogeologic Property of Bedrock Aquifer of Mockcheon Area Applying Several Pumping Test Analyses)

  • 강래수;함세영;최성자;이병대
    • 지질공학
    • /
    • 제13권1호
    • /
    • pp.67-82
    • /
    • 2003
  • 목천지역의 반경 1km 이내에 위치하는 5개 먹는샘물 제조업체(시원샘물, 대정음료, 자인관광, 청수음료, 한주식품)에서 수행된 양수시험자료를 분석하였다. 양수시험분석을 위해서는 Theis(1935), Papadopulos-Cooper(1967), Hantush(1960, 1962), Hantush-Jacob(1955), Moench(1985), Neuman-Witherspoon(1969), Gringarten-Witherspoon(1969), Gringarten-Ramey(1974) 식을 이용하였다. 양수시험 분석 결과, 쐐기형 피압대수층 모델(Hantush, 1962)과 Case-1 누수피압대수층 모델(Moench, 1985)이 연구지역의 암반대수층에 가장 적합한 것으로 나타났다. 상기 모델은 본 연구지역에 나타나는 두 조의 충상단층(Nl8E주향의 충상단층과 NS 주향의 층상단층)에 규제되어 만들어진 대수층의 형태와 잘 일치한 다.

해안대수층에서 담수-염수 경계면 변화에 따른 최대담수양수량과 염수침투제어에 대한 실험적 연구 (Experimental Study of Freshwater Discharge and Saltwater Intrusion Control in Coastal Aquifer)

  • 서성국;오창무;김원일;호정석
    • 한국방재학회 논문집
    • /
    • 제10권5호
    • /
    • pp.159-168
    • /
    • 2010
  • 해안대수층의 지형특성과 수리특성에 의한 담수-염수 경계면과 최대담수양수량의 변화를 연구하였다. 모래 대수층의 수리전도도와 사면경사, 그리고 염수의 염도조건에 따른 담수-염수 경계면의 기울기 및 염수쐐기의 침투길이를 분석하였으며, 일정한 위치의 양수정에서 최대담수양수량과 염수침투제어를 위한 최적염수양수량을 실내 모래수조 모형을 이용하여 분석하였다. 실험결과, 대수층의 수리전도도가 높을수록, 사면경사가 급할수록 최대담수양수량은 증가되었으며, 이때 염도에 의한 영향은 상대적으로 미미하였다. 또한, 최대담수양수량이 증가함에 따라 염수침투제어를 위한 최적염수양수량이 비례적으로 증가되었으며, 그 양은 최대담수양수량 보다 평균 14% 증가되었다. 양수정의 위치에 따라 최대담수양수량과 최적염수양수량은 변화되었고, 염수위와 담수-염수 경계면에서 가까울수록 양수량은 감소하였다. 이러한 결과는 해안지역에서 지하수 개발량의 최대화를 위한 양수정의 위치 선정시, 대수층의 수리전도도, 사면경사 및 염도가 고려되어야 할 것으로 판단된다.

김해 딴섬의 고투수성 충적층에서 수렴흐름 추적자시험에 의한 규모종속 수리분산 연구 (The Scale-Dependent Dispersion Through Convergent Flow Tracer Tests in Alluvial Aquifer with High Permeability at the Ttaan isle, Gimhae City)

  • 강동환;심병완;권병혁;김일규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제12권6호
    • /
    • pp.17-25
    • /
    • 2007
  • 투수성이 높고 대수층의 저유량이 풍부한 강변여과수 개발 예정지역의 충적층에서 시험규모가 2m (IW-1공와 5m (IW-2공)인 경우의 수렴흐름 추적자시험이 수행되었다. 수렴흐름 추적자시험의 양수율은 $2,500m^3/day$ 이었으며, 주입정 (IW-1 및 IW-2공)에 염소이온 5kg을 순간 주입하였다. 염소이온의 농도이력곡선을 작성하여 초기도달시간과 최고농도의 차이를 분석하였으며, 누적질량회수곡선을 통해 양수 후 경과시간에 따른 염소이온의 질량회수율을 분석하였다. 그리고, 염소이온농도 대 누적질량회수율의 이력그래프를 작성하여 누적질량회수율에 따른 염소이온농도의 증가와 감소 변화를 분석하였다. 또한, 염소이온농도의 증가/감소 구간에 대한 선형회귀분석을 수행하여 농도증가율과 감소율의 변화를 파악하였다. 양수정에서 관측된 경과시간별 염소이온농도 자료를 CATTl 코드의 quot;Converging Radial Flow With Instantaneous Injectionquot; 해석법에 적용하여 종분산지수를 추정하였다. 추정된 종분산지수는 양수정과 IW-1공 사이의 충적층에서는 0.4152 m, 양수정과 IW-2공 사이의 충적층에서는 3.2665 m이었다. 양수정에서 이격거리가 멀수록 종분산지수는 증가하였으며, 이격거리에 대한 종분산지수의 비는 각각 0.21과 0.65 정도이었다.

The characteristics of subgrade mud pumping under various water level conditions

  • Ding, Yu;Jia, Yu;Wang, Xuan;Zhang, Jiasheng;Luo, Hao;Zhang, Yu;Chen, Xiaobin
    • Geomechanics and Engineering
    • /
    • 제30권2호
    • /
    • pp.201-210
    • /
    • 2022
  • This paper presents a study regarding the influence of various water levels on the characteristics of subgrade mud pumping through a self-developed test instrument. The characteristics of mud pumping are primarily reflected by axial strain, excess pore water pressure, and fine particle migration. The results show that the axial strain increases nonlinearly with an increase in cycles number; however, the increasing rate gradually decreases, thus, an empirical model for calculating the axial strain of the samples is presented. The excess pore water pressure increases rapidly first and then decreases slowly with an increase in cycles number. Furthermore, the dynamic stress within the soil first rapidly decreases and then eventually slows. The results indicate that the axial strain, excess pore water pressure, and the height and weight of the migrated fine particles decrease significantly with a low water level. In this study, when the water level is 50 mm lower than the subgrade soil surface, the issue of subgrade mud pumping no longer exist.

TFT -LCD 구동 IC용 커패시터 내장형 DC-DC 변환기 설계 (A DC-DC Converter Design with Internal Capacitor for TFT-LCD Driver IC)

  • 임규호;강형근;이재형;손기성;조기석;백승면;성관영;이용진;박무훈;하판봉;김영희
    • 한국정보통신학회논문지
    • /
    • 제10권7호
    • /
    • pp.1266-1274
    • /
    • 2006
  • 본 논문에서는 TFT-LCD 구동 IC 모듈의 소형화측면에서 유리한 DC-DC 변환기 회로인 펌핑 커패시터 내장형 비중첩 부스트-클락 전하펌프 (Non-overlap Boosted-Clock Charge Pump: NBCCP) 회로가 제안되었다 .2VDC 전압으로 스윙하는 비중첩 부스트-클럭의 사용으로 기존의 펌핑 커패시터 내장형 크로스-커플드 전하펌프에 비해 펌핑 단의 수를 반으로 줄일 수 있었고, 전하 펌핑 노드의 펌핑된 전하가 입력 단으로 역류되는 현상을 방지하였다 . 그 결과 제안된 펌핑 커패시터 내장형 비중첩 부스트-클럭 전하펌프 회로는 기존의 펌핑 커패시터 내장형 크로스-커플드 전하펌프에 비해 펌핑 전류가 증가하였고, 레이아웃 면적은 감소되었다. 제안된 TFT-LCD 구동 IC용 DC-DC 변환기 회로를 $0.18{\mu}m$ Triple-Well CMOS 공정을 사용하여 설계하고, 테스트 칩을 제작 중에 있다.

양수시험시 방사상흐름을 보이는 균열암반 대수층에서의 우물손실 (Well Loss in Fractured Rock Formation with Radial Flow during Pumping Test)

  • 이철우;이대하;정지곤;김구영;김용제
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제7권4호
    • /
    • pp.17-23
    • /
    • 2002
  • 균열암반내에 시추된 7개의 양수정에서 양수시험을 실시하였다, 여기에서 각 양수율에 따른 수위강하값을 구하였으며, 비평형상태하에서의 단계양수시험은 Cooper-Jacob의 방법에 의해 양수시간을 보정하였다 양수정에서의 대수층 손실상수, 우물손실상수 및 우물손실지수(n)의 산출은 최소제곱법(method of the least square)을 이용한 회귀분석 방법을 이용하였으며, n값의 범위는 1.65∼6.48로 산출되었다. 균열암반내에 시추된 양수정의 우물손실은 케이싱이나, 시추시 발생되는 공벽의 공극감소 등의 영향보다는 방사상흐름에 따른 양수정부근에서의 난류에 의한 영향이 대부분일 것으로 해석된다. 또한 이 난류는 레이놀즈의 수(Reynolds number)에 좌우되는데, 여기에서 암반대수층내의 균열 특성이 유체의 속도를 지배하므로 정확한 n값의 산출은 암반대수층을 이해하는데 중요한 인자가 될 것이다.

에어챔버가 설치된 인라인 취수펌프장에서 수격현상 (Waterhammer for the In-Line Intake Pumping Station with Air Chamber)

  • 김경엽;안철홍;김범준
    • 한국유체기계학회 논문집
    • /
    • 제15권6호
    • /
    • pp.70-76
    • /
    • 2012
  • Recently, because people are taking a great interest in the water supply system and the related facilities are getting larger, the surge suppression is very important problem. The waterhammer occurs when the pumps are started or stoped for operation or tripped due to the power failure. As the waterhammer problems as a result of the pump power failure were very serious, these situations were carefully investigated. Accordingly, we carried out both numerical simulations and field tests to confirm the safety of Juam intake pumping station in which had the in-line pumps. In this paper, it was reviewed that the water supply system has the reliability on the pressure surge, in case the air chambers were installed at both the inlet and the oulet of the in-line pumping station. From the numerical simulations, we found that negative pressure occurred at the inlet disappeared and high pressure occurred at the outlet reduced due to the air chambers. And these results of numerical simulations verified by the field tests. The field tests carried out in case of normal start, normal stop, one and two of pumps emergency stop. By results of simulations and field tests, we are sure that Juam intake pumping station in which have the air chambers is safe for the waterhammer. In addition, we suggested the operation methods of facilities for safe maintenance of the pumping station.