• Title/Summary/Keyword: Pumping test

Search Result 303, Processing Time 0.027 seconds

Visualizing test on the pass-through and collision characteristics of coarse particles in a double blade pump

  • Tan, Minggao;Lian, Yichao;Liu, Houlin;Wu, Xianfang;Ding, Rong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • As the key equipment in deep ocean mining, the slurry pump suffers from wear and blocking problems. In this paper, high-speed photography technique is applied to track the movement rule of single particle of the coarse particle solid-liquid two-phase flow in a double blade slurry pump. The influences of particle diameter and particle density on the pass-through and collision characteristics of particles are analyzed as well. The results show that the average of the passing pump time first decreases and then increases when the particle diameter increases. The average of the passing pump time decreases by 22.7%, when the particle density increases from $1.09g/cm^3$ to $1.75g/cm^3$. Besides, the particle density has great influence on the location where the particle hits the tongue. Most particles of $1.09g/cm^3$ hit the tongue on the left side, while collision location of particles of $1.75g/cm^3$ is mainly on the top and at the right side of the tongue. The research can provide a basis for the optimization design of slurry pump in deep ocean mining system.

The Measurement of Vacuum Pressure for the Rotors of Disk-type Molecular drag Pumps (원판형 분자 드래그펌프 회전자에 대한 압력 측정)

  • Kwon, Myoung-Keun;Kim, Do-Haeng;Hwang, Young-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2725-2730
    • /
    • 2007
  • Turbo-type molecular drag pumps ( MDPs ) are used in the liquid crystal display ( LCD ), semiconductor and other thin film industries. Siegbahn ( disk-type ) molecular drag pumps are used as high-pressure stages in the hybrid-type turbomolecular pumps, where they can operate in the viscous, the transition and the free molecular flow regime. In this study is performed to investigate the pumping characteristics of three-stage disk-type molecular drag pump ( DTDP ) in the molecular transition flow region. The experiments are measured using five vacuum pressure gauges in the positions for rotors of DTDP. The test is performed with nitrogen gas ( $N_2$ ).

  • PDF

Fabrication and Vacuum Performance Test of the NEG Pump for $10^{-9}$ Pa Chamber ($10^{-9}$ Pa대 용기를 위한 NEG 펌프 제작 및 진공성능 조사)

  • 박미영;인상렬
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.312-320
    • /
    • 2001
  • A Non-Evaporable Getter(NEG) pump was fabricated using Zr-V-Fe alloy modules to obtain $10^{-9}$ Pa range pressures. Pumping performances and activation characteristics were investigated and the pumping speeds for hydrogen, deuterium and carbon monoxide gases of the NEG pump were measured. And hydrogen desorption characteristics were examined during activation at $450^{\circ}C$. Futhermore the vacuum performance was compared with those of other high vacuum pumps as turbo-molecular pump, sputter-ion pump, and cryo pump by analyzing the residual gases of the system.

  • PDF

A Study on Speed Control of Hydrostatic Transmission Using High Speed Solenoid Valve (고속전자밸브를 이용한 유압전동장치의 속도 제어에 관한 연구)

  • Park, S.H.;Lee, J.K.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.7
    • /
    • pp.148-157
    • /
    • 1995
  • This study deals with controlling the speed of Hydrostatic Transmission (HST) system throuth the control of pumping stroke of positive displacement pump using high-speed solenoid valve controlled by digital closed loop PWM method. The method which was done in this study is as follows: First, we modified original positive displacement pump and designed pumping stroke control system of HST by using the high-speed solenoid valve. Second, after experimenting static and dynamic characteristics on each signal flow, we identified system parameter of approximated model. Finally, to control the speed of HST, we controlled the angle of the swash plate of positive displacement pump by controlling the pressure in the control cylinder chamber. Test which was carried out in the laboratory shows that transient and steady state response could be improved by PID controller.

  • PDF

Mock-up Tests of Concrete Filled Steel Tubular Columns (콘크리트 충전 강관 기둥의 시공에 관한 연구)

  • Lee, Deok-Chan;Choi, Jin-Man;Lee, Do-Heon;Kim, Hoon;Kim, Jin-Cheol;Park, Yon-Dong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.382-387
    • /
    • 1996
  • Three concrete filled steel tubular columns with six inner diaphrams are constructed and tested under field conditions. The size and shape of three columns are exactly same. The cross section is $40\times40cm$, and the height is 9m. Each column is constructed with normal concrete, CFST concrete, and high flowing concrete, respectively. Concrete is pumped into bottom parts of steel tubular columns from a concrete pump on the ground. Test data indicate that the slump flow of the concrete place in the top of the column is lower than that of the concrete before pumping by about 10~20cm. Slump flow loss of high flowing concrete caused by pumping is high compared to the other concretes. Concrete pump pressure of high flowing concrete is somewhat higher than that of CFST concrete.

  • PDF

An Expreimental Study on the Pumping Performance of Various Turbo-Type Drag Pumps (터보형 드래그펌프의 배기특성에 관한 실험적 연구)

  • Hwang, Y.K.;Heo, J.S.;Choi, W.J.;Kwon, M.K.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.555-560
    • /
    • 2000
  • An experimental study on pumping characteristics of various turbo-type drag pumps is purformed. The inlet pressures are measured for various outlet pressures of the test pump. The maximum compression ratios for nitrogen are 100,000(Disk-type drag pump+ turbo molecular pump), 10000(Helical-type drag pump+turbo molecular pump), 850 (Helical-type drag pump), 100(disk-type drag pump).

  • PDF

Fuel Consuming Reduction by Power Steering System Optimization (동력 조향계 최적화에 의한 연비 개선)

  • Jo, Sok-Hyun;Nam, Kyung-Woo;Kwon, O-Sung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.3
    • /
    • pp.119-124
    • /
    • 2006
  • This paper deals with energy-saving effort in the hydraulic power steering system. Commonly, the hydraulic power steering systems are used for passenger cars and the reduction of pumping loss under non-steering condition is important to improve fuel economy. Experiments and simulations are performed simultaneously to examine the main factors to reduce the pumping loss-pressure loss and flow rate of the power steering systems. Fuel economy effect of the optimal design of power steering system is verified by vehicle test - more than 1% fuel consuming reduction is attained.

Evaluation criteria for filling performance of high-flowing concrete using steel-concrete panel

  • Dong Kyu Lee;Jae Seon Kim;Myoung Sung Choi
    • Advances in concrete construction
    • /
    • v.16 no.5
    • /
    • pp.231-241
    • /
    • 2023
  • The purpose of this study was to evaluate the practical application of high-flowing concrete for a steel-concrete panel (SCP) module for a liquefied natural gas (LNG) storage tank. We evaluated the physical properties and filling performance of the developed concrete for the SCP module. First, slump tests were performed to evaluate the performance of the proposed standards for the filling tests. All the concrete mixes showed satisfactory performance. Based on the results of the previous study, the reliability of the required time measured using the T500 test and the rheometer results measured before and after pumping was 0.94, indicating that segregation and blocking should not occur. L-box and U-box tests were conducted before and after pumping. All the recommended standards showed satisfactory performance. The SCP structural module for LNG storage tanks was fabricated to a full scale to evaluate its practical application at the final site. Satisfactory filling performance was confirmed for all the specimens.

Behavior of Geotextile Tube by Numerical Analysis (수치해석기법을 이용한 지오텍스타일 튜브의 거동분석)

  • 신은철;오영인;조인휘
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.385-392
    • /
    • 2003
  • Traditional forms of river and coastal structures have become very expensive to build and maintain, because of the shortage of natural rock. Geotextile tubes hydraulically or mechanically filled with dredged materials have been applied in hydraulic and coastal engineering in recent years(shore protection structure, detached breakwater, groins and jetty). Recently, new preliminary design criteria supported by model and prototype tests, and some stability analysis calculations have been studied. In this study, the numerical analysis was performed to investigate the behavior of geotextile tube with various properties of geotextile and hydraulic pumping conditions. Numerical analysis was executed to compare with the results from the large-scale field model tests, and also compared the results of 2-D plane strain analysis and 3-D FEM analysis. A geotextile tube was modeled using the commercial finite element analysis program ABAQUS and the one-quarter of tube was modeled. Behavior of geotextile tube during the hydraulic pumping procedure was analyzed by comparing the large-scale field model test and numerical analysis. The shape variation and maximum tube height between the numerical analysis results and large-scale filed test results are turned out to be a good agreement.

  • PDF

Temperature and Compositional Characteristics of the Hot Spring Water in Korea (우리나라 온천의 온도 및 성분 특징)

  • Lee, Cholwoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.121.1-121.1
    • /
    • 2010
  • We analyzed the temperature and chemical composition of 376 hot springs in Korea. It took about three days for the temperature to stabilize after the pumping test. After the stabilization, in-situ and laboratory analyses of the hot spring water were carried out. The average temperature and TDS were $29.95^{\circ}C$ and 2,071mg/L, respectively. The temperature ranging $25-30^{\circ}C$ were recorded from 70% of hot springs, and $30-35^{\circ}C$ of 15.4%. The maximum temperature was about $78^{\circ}C$. The value of TDS in 79% of the wells was below 1,000 mg/L. 5.5% of the wells, mostly developed near seashore, shows higher values than 10,000mg/L of TDS suggesting the influence of seawater. The hot spring water shows 8.49 of pH representing a weak alkali. For the mineral compositions dissolved in the hot spring in Korea, Na (431 mg/L) and Ca (188 mg/L) are the major cations, and Cl (840 mg/L) and $SO_4$ (213 mg/L) are the major anions.

  • PDF