• 제목/요약/키워드: Pumping test

검색결과 302건 처리시간 0.029초

관개용 관정의 가채빙량 추정에 관한 연구 (A Study on the Determination Method of Pumpin Rates in Tube Wells for Irrigation)

  • 구자웅;류한열
    • 한국농공학회지
    • /
    • 제18권4호
    • /
    • pp.4209-4217
    • /
    • 1976
  • The purpose of this thesis is to search for the determination method of pumping rates in the existing tube wells for irrigation. Pumping tests were carried out for the twelve test tube wells which were selected in the provinces of Kyounggi, Kangwon, Chungbuk and Chungnam. The depths, static water levels, pumping levels, drawdowns and yields of tube wells were measured in the pumping tests, and a centrifugal pump with 3 inches diameter, a 5 HP motor and a 90$^{\circ}$ V-notch were used in the pumping tests. The average coefficient of transmissibility calculated by Chow's and Jacob's methods is 0.0336 square meter per second, and the average pumping rate calculated by Thiem's, Smreker's, Brinkhaus' and Theis' formulae, is 919 cubic meter per day, Therefore, the ground water storage in the test areas is comparatively abundant. Correlation between pumping rates and depths of tube wells is not in existence. Also, correlation between pumping rates and the thickness of aquifer is not found in this experiment. This shows that the depths of some tube wells are deep and their thicknesses of aquifer are thick, but their ground water storages are poor, and that the depths of some tube wells are shallow and their thicknesses of aquifer are thin, but their ground water storages are abundant. It seems that the test tube wells are influenced by the peculiar characteristics that the ground water in the test areas is free ground water in alluvium layer closely related with surface water. As drawdown increases, pumping rate decreases, and as the coefficient of transmissibility increases, pumping rate also increases. Namely, there are negative correlation between pumping rate and drawdown, and positive correlation between pumping rate and the coefficient of transmissibility. Judging from the results of the pumping tests in these tests areas, the pumping rate calculated by the formula, {{{{ { Q}_{m } =Q { ( { { S}_{ m} } over { TRIANGLE S } )}^{ { 2} over {3 } } }}}} used traditionally, is likely to be higher than real pumping rates. The formula, {{{{ { Q}_{m } =Q { { H}^{ 2} } over { (2H- TRIANGLE S) TRIANGLE S} }}}} derived from Thiem's theory, is looked upon as the reasonable one to detemine pumping rates in the existing tube wells for irrigation.

  • PDF

A General Solution of Determining Storage Coefficient From Multi-Step Pumping Test Recovery Data

  • Jin-Yong Lee;Kang-Kun Lee
    • 대한지하수환경학회지
    • /
    • 제7권1호
    • /
    • pp.20-23
    • /
    • 2000
  • 양수시험시 획득되는 회복자료만을 이용하여 저유계수를 추정하는 일반해를 제시하였다. Banton and Bangoy(1996)가 제시한 단 단계(single-step) 양수시험에서 얻는 회복자료를 이용한 저유계수 추정해를 일반적인 다단계 (multi-step)시험 회복자료에도 적용 가능하게 확장한 것이다. 본 연구에서 구한 일반 해를 이용하여 저유계수와 투수계수를 구한 결과 다른 방법으로 구한 결과 값과 잘 일치하였다.

  • PDF

펌핑 조건에 따른 콘크리트 작업성 변화 실내 평가 방법 제안 (Suggestion of a Evaluation Method for Variation of Concrete Workability According to Pumping Condition through Lab-Scale Test)

  • 이정수;장경필;권승희
    • 한국건설순환자원학회논문집
    • /
    • 제8권4호
    • /
    • pp.413-420
    • /
    • 2020
  • 이 연구에서는 펌핑 후 콘크리트의 작업성 변화를 실내에서 평가하기 위한 새로운 실험 장비를 개발하였다. 이 장비는 실제 펌핑 중 콘크리트가 받는 압력과 전단을 모사할 수 있도록 설계되었다. 실내 실험 장비를 사용한 펌핑 후 콘크리트 작업성 변화 평가 가능성을 검토하기 위하여 실규모 펌핑 실험과 실내 모사 실험을 동시에 수행하였다. 실규모 펌핑 실험에 사용한 콘크리트의 설계기준압축강도는 24, 35, 60MPa이며, 배관의 길이는 130, 304, 518m이다. 펌핑 실험과 동일한 콘크리트를 사용하여 실제 펌핑 조건(압력, 전단, 펌핑 시간)을 고려한 실내 모사 실험을 수행하였다. 실험 전, 실규모 펌핑 실험 후, 실내 모사 실험 후 콘크리트의 작업성(슬럼프 또는 슬럼프 플로)을 측정하였다. 실규모 펌핑 실험과 실내 실험 모두 콘크리트의 작업성이 감소하였으며, 두 실험의 결과가 매우 유사하게 측정되었다.

장기 및 단계 양수시험 시 강변여과 지하수의 수질변화 특성 (Geochemical Characteristics of Groundwater during the Constant and Step-drawdown Pumping Tests at the River Bank Filtration Site)

  • 김규범;신선호;김병우;박준형
    • 한국지반환경공학회 논문집
    • /
    • 제14권8호
    • /
    • pp.11-21
    • /
    • 2013
  • 창녕군 낙동강변의 강변여과 예정 지점에서 양수시험 동안에 발생하는 지하수 내 철과 망간을 포함한 다양한 수질항목 변화를 파악하기 위한 실험을 수행하였다. 5단계의 단계양수시험($500m^3/day{\sim}900m^3/day$) 및 26시간의 장기 양수시험($800m^3/day$) 동안에 양수정과 10개의 관측정에서 지하수 시료를 채취하였다. 장기 양수시험보다는 단계양수시험 기간 동안에 이온 농도의 변화가 뚜렷하였다. 특히, 단계양수시험 동안의 철과 망간 농도의 감소는 양수지점과 대수층의 연결성이 좋아 영향반경이 작은 방향을 따라 뚜렷하게 나타났다. 양수량의 급변에 따라 지하수 흐름에 교란이 발생하고 공기 접촉 등을 통하여 용존 철과 망간의 침전 산화가 촉진되는 것으로 평가되었다. 향후 지하수 내 철과 망간 저감을 위한 효율적인 지중처리 기술 개발을 위해서는 양수정의 운영 방법, 대수층의 공간적 분포 등이 중요한 요인으로 고려되어야 한다.

비증발형 게터소자 배기특성 평가시험 (Pumping Performance Test of the NEG Elements)

  • 인상렬;박미영;정기석
    • 한국진공학회지
    • /
    • 제13권2호
    • /
    • pp.47-53
    • /
    • 2004
  • 국내 진공기술 기반을 구축하는 국가사업의 일환으로 게터펌프 성능평가장치를 개발하고 있다. 본격적으로 장치를 구성하기 전에 평가절차의 개발, 장치 설계요건 및 사양을 확정하기 위해 예비실험장치를 만들었다. 이 장치를 이용하여 밀봉형 기기에 들어가는 비교적 활성화 온도가 낮은 게터 소자들의 특성평가 절차를 만들고 이를 적용하여 수소, 일산화탄소, 질소 등에 대해 배기속도와 배기용량을 측정해 보았다. 주로 고순도 기체 공급장치용으로 국내에서 개발된 게터 소자와 램프용으로 널리 쓰이는 외국제품의 배기성능을 비교해 보았다.

Evaluation of Pumping Characteristics of High Strength Concrete using Continuous Pumping System

  • Kwon, Dae-Hun;Lee, Han-Seung;Jeon, Jun-Young;Jeong, Woong-Taek;Jo, Ho-Kyoo;Kim, Hyung-Rae
    • 한국건축시공학회지
    • /
    • 제11권4호
    • /
    • pp.387-395
    • /
    • 2011
  • In the construction of tall-building, concrete pumping influences the success of the project. In order to establish pumping technology for high speed construction of tall building, study for quantitative evaluation of flow characteristics and pumpability should be conducted. So in this study, the characteristics including the inner pipe pressure, rheological properties of concrete and mortar through the continuous pumping test were evaluated. Then we analyzed the relations between rheological properties and pumpability. In the result of test, there are high correlations between the rheological characteristics which represented by yield stress and plastic viscosity and pressure loss with pipe length. Also, we estimated pressure loss according to conditions of concrete mix and pumping through the evaluation of inner pipe friction.

상주시 임곡리 굴착공의 적정양수량 결정 (Optimal Pumping Rate of a Water Well at Imgokri, Sangju City)

  • 조병욱;윤욱;문상호;이병대;조수영;김용철;황세호;신제현;하규철
    • 지질공학
    • /
    • 제27권3호
    • /
    • pp.255-265
    • /
    • 2017
  • 상주시 임곡리에 굴착된 심도 100 m 지하수공(PW-2)의 적정양수량을 산정하였다. 시추코아와, 물리검층 자료에 의하면 지하수 산출 심도는 26.1~26.5, 28.0~30.0, 33, 58, 71 m로 해석된다. 단계양수시험에 의하면 40, 55, 70, 90, $132m^3/d$의 양수량으로 70일간 양수시 수위강하량은 각각 6.48, 11.56, 18.07, 28.99, 60.26 m로 예상되었다. $117m^3/d$으로 250분간 실시한 일정량양수시험에서는 양수 경과시간 120~150분에 영향추가 불투수층 경계조건에 도달하여 급격한 수위강하가 일어나 PW-2의 한계채수량은 $90m^3/d$로 산정하였으며 이때의 수위강하량은 28.82~31.27 m이다. 적정양수량은 한계채수량의 범위내의 정류상태여야 하기 때문에 PW-2의 적정양수량은 $70{\sim}90m^3/d$로 제시하였다. 불투수층 경계조건에서 직선의 기울기가 급해지며 지하수의 DO와 ORP가 증가하는 것으로 보아 PW-2를 중심으로 한 기반암지하수의 발달은 제한적인 것으로 추정된다.

터보형 원판형 드래그펌프의 배기특성에 관한 실험적 연구 (An Experimental Study on the Pumping Performance of the Turbo-Type Disk-Type Drag Pump)

  • 황영규;허중식;권명근;이승재
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.577-580
    • /
    • 2002
  • In this paper, the pumping performance of the disk-type drag pump which works in the outlet pressure range from 4 to 0.001 Torr is studied experimentally. The pumping characteristics of various drag pumps are performed. The inlet pressures are measured for various outlet pressures of the test pump. The flow-meter method is adopted to calculate the pumping speed. Compression ratios and pumping speeds for the nitrogen gas are measured. The present experimental data show the leak-limited value of the compression ratio in the molecular transition region. The rotational speed of the pump is 24,000rpm. The inlet pressures are measured for various outlet pressures of the test pump. The ultimate Pressures for zero throughput are measured for three-stage, two-stage and single-stage disk-type, respectively.

  • PDF

Transition Analysis of Friction Factor According to Pumping Pressure in Pumping Test Using High Strength Concrete for High-rise Buildings

  • Kwon, Hae-Won;Kim, Young-Su
    • 한국건축시공학회지
    • /
    • 제13권4호
    • /
    • pp.400-406
    • /
    • 2013
  • In high-rise buildings, high-strength concrete is widely used to reduce the section of structure members under axial load. Also, the price increase of materials is very important item in the high-rise buildings. Especially, concrete used high-pressure pump due to consecutive structural assembly. Unlike slump type of ordinary concrete, high strength concrete has different properties of concrete pumping due to viscosity. However, there have been no Korean studies on the pumping properties of high strength concrete. Therefore, this paper measures the friction factor of high strength concrete with changes in the pressure of concrete pumping. We analyzed the trends of the friction factor based on changes in the pressure of concrete pumping, and then calculated the quantity of concrete deposited for each specified concrete strength and location of placement. After comparing these results with the quantity of concrete deposited measured in field, we evaluated the pumping properties of high strength concrete. Through the tests and the review, we attempt to suggest some basic information for the In-Situ application of high strength concrete.

친수지역 강변여과수 열원을 활용한 냉난방시스템 개발 (Development of Water-Source Heat Pump System Using Riverbank Filtration Water on the Waterfront)

  • 조용;김대근;문종필
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.201.2-201.2
    • /
    • 2011
  • A water-source heat pump system has been developed for cooling and heating of a green house on the waterfront in Jinju. In order to supply a heat source/sink of water in alluvium aquifer to the heat pump system, the riverbank filtration facility (two pumping wells and one recharge well) for water intake and injection has been constructed. To pump and recharge water sufficiently, the geometric design such as depth and diameter for the wells have been completed, and details of the well such as slot size and length of the screen and filter pack size have been designed based on the practical and theoretical design method including D30 technique. For the investigation of the hydrogeological characteristics, step-drawdown test, long-term pumping test, and recovery test have been carried out for two developed pumping wells. Step-drawdown test has been performed on 4 step flowrates of 150, 300, 450, $600m^3$/day for 1 hour, and long-term pumping test on flowrate of $500m^3$/day for 24 hours, and recovery test for 6 hours. Since the underground water filtrated by riverbank is flowing smoothly into the well, the water level goes down slightly for the long-term test. Consequently, the stable pumping flowrate for two pumping well has been predicted at least over $1,647m^3$/day which is larger than the flowrate of $1,000m^3$/day for a 60 RT heat pump system.

  • PDF