• 제목/요약/키워드: Pumping phase

검색결과 85건 처리시간 0.028초

3.2-kW 9.7-GHz Polarization-maintaining Narrow-linewidth All-fiber Amplifier

  • Hang Liu;Yujun Feng;Xiaobo Yang;Yao Wang;Hongming Yu;Jue Wang;Wanjing Peng;Yanshan Wang;Yinhong Sun;Yi Ma;Qingsong Gao;Chun Tang
    • Current Optics and Photonics
    • /
    • 제8권1호
    • /
    • pp.65-71
    • /
    • 2024
  • We present a Yb-doped narrow-linewidth polarization-maintaining all-fiber amplifier that achieves a high mode-instability (MI) threshold, high output power, and 9.7-GHz spectral linewidth. Six wavelength-multiplexed laser diodes are used to pump this amplifier. First, we construct a high-power fiber amplifier based on a master oscillator-power amplifier configuration for experiments. Subsequently, we examine the MI threshold by individually pumping the amplifier with wavelengths of 976, 974, 981, 974, and 981 nm respectively. The experimental results demonstrate that the amplifier exhibits a high MI threshold (>3.5 kW) when pumped with a combination of wavelengths at 974 and 981 nm. Afterward, we inject an optimized phase-modulated seed with a nearly flat-top spectrum into this amplifier. Ultimately, laser output of 3.2 kW and 9.7 GHz are obtained.

고온형 고분자전해질형 연료전지에서의 사형 유로와 평행 유로 성능비교에 대한 수치해석적 연구 (Numerical Study on Comparison of Serpentine and Parallel Flow Channel in High-temperature Proton Exchange Membrane Fuel Cells)

  • 안성하;오경민;주현철
    • 한국수소및신에너지학회논문집
    • /
    • 제29권1호
    • /
    • pp.41-55
    • /
    • 2018
  • General polymer electrolyte fuel cell (PEMFC) operates at less than $80^{\circ}C$. Therefore liquid phase water resulting from electrochemical reaction accumulates and floods the cell which in turn increases the mass transfer loss. To prevent the flooding, it is common to employ serpentine flow channel, which can efficiently export liquid phase water to the outlet. The major drawback of utilizing serpentine flow channel is the large pressure drop that happens between the inlet and outlet. On the other hand, in the high temperature polymer electrolyte fuel cell (HT-PEMFC), since the operating temperature is 130 to $180^{\circ}C$, the generated water is in the state of gas, so the flooding phenomenon is not taken into consideration. In HT-PEMFCs parallel flow channel with lower pressure drop between the inlet and outlet is employed therefore, in order to circulate hydrogen and air in the cell less pumping power is required. In this study we analyzed HT-PEMFC's different flow channels by parallel computation using previously developed 3-D isothermal model. All the flow channels had an active area of $25cm^2$. Also, we numerically compared the performance of HT-PEMFC parallel flow channel with different manifold area and Rib interval against the original serpentine flow channel. Results of the analysis are shown in the form of three-dimensional contour polarization curves, flow characteristics in the channel, current density distribution in the Membrane, overpotential distribution in the catalyst layer, and hydrogen and oxygen concentration distribution. As a result, the performance of a real area fuel cell was predicted.

비강내 주기유동장의 실험적 해석에 관한 연구 (The experimental research on periodic airflow in human nasal cavity)

  • 김성균;손영락;신석재
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1687-1692
    • /
    • 2004
  • CT 사진을 이용하여 살아있는 사람의 비강 형상을 얻고 RP 를 이용하여 모형을 만들고 이 모형 으로 정교한 비강 유로 모형을 제작하였고, 호흡을 정확하게 모사하는 펌프를 만들었다. 사람의 호흡 데이터를 이용하여 캠을 제작하고 대형 피스 톤 펌프를 만들어 사람의 호흡을 정확 하게 모사 하였다. 이를 이용하여 생리적 주기를 갖는 비강 내 유동에 대한 결과를 획득하고 기존의 일정유량 하의 실험결과와 비교 분석하였다.

  • PDF

고층 건축공사의 시공성 향상을 위한 설계단계의 시공엔지니어링 업무 도출 - 가설공사를 중심으로 - (Identifying Construction Engineering Tasks at the Design Phase for Enhancing Constructability in High-rise Building Construction - Focused on Temporary Work -)

  • 이진웅;조규만;김태훈
    • 한국건축시공학회지
    • /
    • 제17권5호
    • /
    • pp.453-463
    • /
    • 2017
  • 건물의 고층화와 규모의 증가로 인해 프로젝트 설계단계에서의 시공성을 반영한 엔지니어링 기술의 중요성이 점점 커지고 있다. 특히, 설계단계에서의 가설작업을 위한 설비, 장비 및 공법과 관련된 엔지니어링 기술적용의 노력은 시공성 및 프로젝트 성과 향상에 크게 기여할 수 있다. 이에 본 연구에서는 고층 건축공사의 시공성 향상을 위하여 가설공사를 중심으로 설계단계에 요구되는 시공엔지니어링 업무를 도출하고자 하였다. 우선, 문헌고찰과 전문가 집단면접을 통해 27개의 예비 업무를 도출하였으며, 그 후 설문조사를 통하여 각 업무의 필요성 및 중요도를 분석하였다. 분석 결과, 골조공사 및 양중장비 계획과 관련된 대부분의 업무가 상대적으로 중요한 것으로 분석되었다. 마지막으로 요인분석을 통해 21개의 엔지니어링 업무를 선정하였으며, 이들 업무는 크게 1)골조공사 및 측량/동선계획, 2)양중 및 콘크리트 압송계획, 3)공간구획계획, 4)용수계획, 5)가설건물 및 전력/조명계획의 5개 요인으로 분류되었다. 본 연구의 결과는 설계단계에서 시공엔지니어링 업무를 효과적으로 반영할 수 있는 프로세스 수립을 위한 기초 자료로 활용될 수 있을 것이다.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2006년도 추계학술대회
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

분무열분해법으로 제조된 SrAl2O4:Ho3+ 녹색 형광체의 발광특성 (Luminescence Characterization of SrAl2O4:Ho3+ Green Phosphor Prepared by Spray Pyrolysis)

  • 정경열;김우현
    • Korean Chemical Engineering Research
    • /
    • 제53권5호
    • /
    • pp.620-626
    • /
    • 2015
  • $Ho^{3+}$가 도핑된 $SrAl_2O_4$ 상향전환 형광체 분말을 분무열분해법으로 제조하고 활성제의 농도, 후 열처리 온도 변화에 따른 결정학적 구조와 발광 특성을 조사하였다. 또한 유기 첨가제 사용에 따른 형광체의 결정구조, 표면적 및 휘도 변화를 조사하였다. $SrAl_2O_4:Ho^{3+}$$Ho^{3+}$$^5F_4/^5S_2{\rightarrow}^5I_8$ 전이에 기인한 강한 녹색 발광을 보였다. 가장 높은 발광 강도를 보이는 $Ho^{3+}$ 농도는 0.1%였고, 그 이상의 농도에서는 활성 이온간 쌍극자-쌍극자 상호 작용에 의에 농도소강이 일어나 발광 휘도는 급격히 감소하였다. 여기 광원의 전력 세기에 따른 발광 휘도 변화 관찰로부터 $SrAl_2O_4:Ho^{3+}$의 녹색 발광은 2광자가 관여된 바닥상태흡수-여기상태흡수 과정을 통해 효율적으로 일어남이 확인되었다. 합성된 분말의 주상은 단사정계이고 일부 육방정계 상이 존재하였다. 후 열처리 온도를 $1000^{\circ}C$에서 $1350^{\circ}C$로 증가시킴에 따라 $SrAl_2O_4:Ho^{3+}$는 육방정계 상이 줄어 들면서 단상정계의 결정성이 향상되었다. 그러나 $1350^{\circ}C$에서도 일부 육방정계 상은 존재하였다. 구연산(CA)과 에틸렌 글리콜(EG)을 첨가해준 분무 용액으로부터 제조한 경우, 육방정계 상이 없는 순수한 단사정계 상으로 향상된 결정성을 가지는 $SrAl_2O_4:Ho^{3+}$가 제조되었다. 또한 유기 첨가제와 함께 N,N-Dimethylformamide(DMF)를 분무용액에 넣어 줌으로써 형광체의 표면적을 크게 감소시킬 수 있었다. 그 결과 CA/EG/DMF를 넣고 제조한 $SrAl_2O_4:Ho^{3+}$ 형광체는 유기 첨가물 없이 제조한 형광체에 비해 발광 휘도가 약 168% 향상되었다. 이러한 휘도 증대는 $SrAl_2O_4:Ho^{3+}$ 형광체의 결정상이 순수해졌고, 결정성 증대와 표면 결함을 최소화시킨 결과라고 결론지었다.

8YSZ 기판에 증착한 $\textrm{WO}_3$ 박막의 DC 전압에 따른 $\textrm{NO}_X$ 감지특성 (Electrical Property Changes of $\textrm{NO}_X$ Sensitive $\textrm{WO}_3$ Thin Films as Applied DC Voltages on 8YSZ Substrate)

  • 전춘배;박기철
    • 전자공학회논문지T
    • /
    • 제36T권1호
    • /
    • pp.8-12
    • /
    • 1999
  • 산소이온 펌핑효과를 나타내는 8% 이트리아가 함유된 ZrO\sub 2\ 이온 전도체를 기판으로 하여 그 위에 NO\sub x\가스에 대해 감지효과를 갖고 있는 것으로 알려져 있는 WO\sub 3\산화물 반도체를 사용하여 박막시편을 제작하였다. 각 소자의 NO\sub x\ 가스에 대한 전기적 특성과 열처리 온도에 따른 미세구조의 변화를 조사하였고, 특히 8YSZ 기판에 가해준 전압에 의한 NO\sub x\ 가스 감지의 증대효과를 조사하였다. 열처리 온도에 따른 WO\sub 3\ 박막표면의 SEM사진의 분석에서 열처리하지 않은 WO\sub 3\ 박막은 비결정질 상태이지만 600℃이상의 열처리 온도에서 결정화가 이루어졌고 사방경계상의 WO\sub 3\ 피크가 나타났으며 온도가 증가함에 따라 (111)면과 (001)면이 특히 많이 성장하였다. 측정온도 400℃에서 8YSZ 기판에 전압을 가하지 않았을 때보다 전압을 가하였을 경우가 더 안정되고 더 큰 응답을 보였으며, 특히 2V 일 때가 가장 높은 감도를 나타내었다. 그리고 NO\sub 2\ 가스보다 NO 가스에 대한 회복특성이 훨씬 우수했다.

  • PDF

H 연구지역의 수리지질-수리분산특성과 지하수 오염가능성 평가연구 (A Study on Hydrogeologic, Hydrodispersive Characterization and Groundwater Contamination Assessment of an H-site)

  • 한정상
    • 자원환경지질
    • /
    • 제27권3호
    • /
    • pp.295-311
    • /
    • 1994
  • A comprehensive in-situ tests are performed to define the hydrogeologic and hydrodispersive characteristics such as hydraulic conductivities, longitudinal dispersivity, and average linear velocities as well as conducting flow-net analysis at the study area. The results show that the study area is very heterogeneous so that hydraulic conductivities range from $6.45{\times}10^{-7}$ to $1.15{\times}10^{-5}m/s$ with average linear velocities of 0.34~0.62m/day. Whole groundwater in upper-most aquifer is discharging into the sea with specific discharge rate of $7.2{\times}10^{-3}$ to $1.3{\times}10^{-2}m/day$. The longitudinal dispersivity of the aquifer is estimated about 4.8m through In-situ injection phase test. The area is highly vulnerable to potential contaminant sources due to it's high value of DRASTIC index ranging from 139 to 155 and also under water table condition with very shallow groundwater level. To delineate contaminant plumes of toxic NaOH and carcinogenic benzene when these substances are assumed to be leaked through existing TSDF at the study area by unexpected accidents or spill, Aquifer Simulation Model (ASM) including Flow and Transport Model is used. Te simulated results reveal that the size of NaOH plume after 5 years continuous leak is about $250{\times}100m$ and benzene after 10 years, $490{\times}100m$. When the groundwater is abstracted about 50 days, which is maximum continuously sustained no-precipitation period during 30 years, with pumping rate of $100m^3/day$, THWELL program shows that the groundwater is adversly affected by sea water intrusion.

  • PDF

공기부양 펌프의 관직경과 잠수비 변화에 따른 기포 형상과 성능에 관한 실험적 연구 (Experimental Study of Performance and Bubble Pattern of Air-Lift Pumps with Various Tube Diameters and Submergence Ratios)

  • 김승환;손채훈;황준영
    • 대한기계학회논문집B
    • /
    • 제37권9호
    • /
    • pp.837-845
    • /
    • 2013
  • 공기부양 펌프는 액체 내 공기부양 효과에 의해 양수 조작이 어려운 액체 및 액체 내의 침전물을 손상 없이 토출할 수 있는 장점을 가지고 있다. 이러한 장점을 이용하여 DCFC(Direct Carbon Fuel Cell)에서 고온의 용융된 연료를 혼합 및 순환시키기 위해 공기부양 펌프를 적용할 수 있다. 이를 위한 연구의 일환으로 공기부양 특성을 파악하기 위한 기초 실험을 수행하였다. 본 실험에서는 공기부양 펌프 시스템을 구축하여 저수통 내에 모사 액체로 물을 채우고 관(tube)을 삽입한 후, 관 하단부에 가스유량을 공급하여 상단부의 토출유량을 측정하였다. 설계 인자로서 관직경과 잠수비를 변경하면서 이에 맞는 공기유량을 공급하였고, 정해진 각 조건에서 생성된 관 내부의 기포(bubble) 형상을 디지털 카메라로 촬영, 그 형상을 네 단계로 구분하였다. 펌프의 성능을 이론식을 모델링하여 실험 데이터와 비교하였고, 토출 유량을 측정하여 물이 토출되는 시작점인 가스유량과 전체 유량비와의 상관관계를 분석하였다.

태양열 물펌프의 실험적 성능분석 (Experimental Analysis on the Performance of a Solar Powered Water Pump)

  • 김영복;손재길;이승규;김성태;나우정;이양근
    • Journal of Biosystems Engineering
    • /
    • 제29권6호
    • /
    • pp.521-530
    • /
    • 2004
  • The solar powered water pump is very ideal equipment because solar power is more intensive when the water is more needed in summer and it is very helpful in the rural area, in which electrical power is not available. The average solar radiation power is $3.488\;kWh/(m^2{\cdot}day)$ in Korea. In this study, the experimental system of the water pump driven by the radiation energy were designed, assembled, tested and analyzed fur realizing the solar powered water pump. Energy conversion ken radiation energy to mechanical energy by using n-pentane as operating material was done and the water pumping cycles were able to be continued. The quantity of the water pumped per cycle ranged from 2 L to 10 L depending on the level of the valve open area far the vapour supply. The average quantity was about 4,366 cc. The thermal efficiency was about $0.018\%$. The pressure level of the n-pentane vapour in flash tank was about $110\~150\;kPa$ and that in the water tank was $93\~130\;kPa$. The pressure in the condenser during cycles was maintained as about 70 kPa. The condensation of the n-pentane vapour in the water tank was increased with the cycles even though the internal and external insulation were done. Air tank performance was better with increasing of the water piston displacement and the water could be pumped with the water piston displacement becoming higher than 6,500 cc.