• 제목/요약/키워드: Pumped volume

검색결과 35건 처리시간 0.024초

양구해안분지에서 기존 농업용수 이용량 산정식에 따른 양수량과 실측 양수량 비교 (A Comparison of Estimated Groundwater Consumption Using Existing Formulae with Actual Pumped Volumes in the Haean Basin, Korea)

  • 유한선;전우현;권기덕;이진용
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권4호
    • /
    • pp.1-8
    • /
    • 2017
  • Efficient groundwater management requires accurate information about the water volume used. The pumped volume of groundwater can be indirectly estimated using empirical formulae based on electric power consumption. The purpose of this study is to test the accuracy of this indirect method. The Haean basin in Gangwon is located in a rural area, where majority of the groundwater extracted is used for irrigation. The pumped volume of groundwater indirectly estimated from electricity usage using these empirical formulae was compared with the actual pumped volume determined by conducting experiments on April 29 and May 19, 2017. The field survey collected data on electricity usage, pumped volume, and groundwater levels. Based on this measured data, correlations were calculated between electricity usage and pumping volume, as well as groundwater level and pumping rate. The results show that electricity usage and pumped volume measured for both wells (YHE1 and YHE2) are highly correlated (r=0.99, p<0.001). However, for YHE1, notably, the correlation between the groundwater level and pumping rate was not significant, and only some correlations were identified for these variables for the YHE2 test well. The average error with respect to the estimation of the actual pumped volume from the existing formula (1) and formulae (2) and (3) are +399% and -88%, respectively. To reduce these errors, these formulae need to consider other factors affecting the pumped volume.

Novel methods of increasing the storage volume at Pumped Storage Power plants

  • Storli, Pal-Tore
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권3호
    • /
    • pp.209-217
    • /
    • 2017
  • The paper presents two novel concepts of increasing the energy storage capacity at pumped storage power plants, both existing and new projects. The concepts utilize compressed air as a working medium to displace water from a volume originally not available for storage. The concepts are likely to give additional storage volume at a low cost, however, much development and many investigations are needed before the concepts can be shown to be technical and economical feasible solutions for energy storage. The concepts are disclosed so that researchers and utilities can start those investigations, hopefully helping the green transition by providing highly valuable energy storage for a future renewable energy having a much higher share of renewable energies than the current systems.

온수 보일러용 열구동 펌프에 관한 연구 (A Study on the Thermal Pump of the Hot Water Boiler)

  • 염한길;김욱중;김창주
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.15-23
    • /
    • 2000
  • In this study, develop the thermal pump using water evaporation and condensation. Vapor from heating room moves up to pumping room and press the water of pumping room. Consequently water is pumped out to water tank. Then hot vapor direct contact with cold water in condensing room after pumping process. At this time, pressure of condensing room is down to-5kPa and suck in water of tank. This pump executes self ping and good durability because of no mechanical moving parts. Thermal pump is pumped cyclic so that, this pump is not used single. Therefore thermal pump of hot water boiler used to multi-stage for stable pumping rate. As the result of performance test, the developed thermal pump proves pumping action of water evaporation/condensation. And total volume flow rate is 500liter during one hour. If three thermal pump is installed parallel, this pump can use to the hot water boiler in the 300,000kcal/h class.

  • PDF

압력 비평형형 유압 베인 펌프의 토출 압력 맥동 특성 연구 (A Study on the Discharge Pressure Ripple Characteristics of the Pressure Unbalanced Vane Pump)

  • 장주섭
    • 한국정밀공학회지
    • /
    • 제26권4호
    • /
    • pp.55-63
    • /
    • 2009
  • This paper reports on the theoretical and experimental study of the pressure ripples in a pressure unbalanced type vane pump which have widespread use in industry. Because they can infinitely vary the volume of the fluid pumped in the system by a control. Pressure ripples occur due to the flow ripples induced by geometry of side plate, leakage flow, reverse flow from the outlet volume produced by pressure difference between pumping chamber and outlet volume when the pumping chamber connected with the outlet volume. In this paper, we measured the pressure variation of a pumping chamber, reaction force on a cam ring, the mathematical model for analyzing the pressure ripples which included vane detachment and fluid inertia effects in notch area has been presented, and was applied to predict the level and the wave form of the pressure ripples according to operating conditions.

Cavitation Characteristics of a Pump-turbine Model by CFD Analysis

  • Singh, Patrick Mark;Chen, Chengcheng;Chen, Zhenmu;Choi, Young-Do
    • 한국유체기계학회 논문집
    • /
    • 제18권4호
    • /
    • pp.49-55
    • /
    • 2015
  • The pumped storage plant operates with quick change of the discharge as well as quick changes between pump mode and turbine mode. This study focuses on the cavitation analysis of a pump-turbine model because in turbo-machinery, cavitation can reduce the performance and shorten service life. The pump-turbine model system consists of 7 blades, 20 stay vanes (including tongue) and 20 guide vanes. This study adopts the Rayleigh-Plesset model as a cavitation model, which illustrates cavitation by using the air volume fraction method. The pump mode and turbine mode at the operating condition of partial loading, normal and excessive loading are analyzed to investigate the cavitation performance of the pump-turbine. It was observed that this pump-turbine design showed very good cavitation characteristics with no cavitation bubbles in all operating conditions. Overall value of air volume fraction of both mode at different operating condition are lower than 1, which confirms low possibility of cavitation occurrence at current situation.

부산시 동래 온천지역의 양수량, 온천수위, 강수량의 관련성 연구

  • 차용훈;함세영;정재열;장성;손건태
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.455-458
    • /
    • 2004
  • This study uses time series analyses to evaluate fluctuation of water levels in a geothermal water well due to pumping, in relation to rainfall at Dongrae hot-spring site on the southeastern coast of tile Korean peninsula. The volume of water pumped from the public study wells ranges from 542 to 993 m$^3$/month, and the minimum water level ranged from 35 to 144.7 m during the measured period. Autocorrelation analysis was conducted for the withdrawal rate at the public wells, water levels and rainfall. The autocorrelation of the withdrawal rate shows distinct periodicity with 3 months of lag time, the autocorrelation of rainfall shows weak linearity and short memory with 1 months of lag time, and the autocorrelation of water levels shows weak linearity and short memory with 2 months of lag time. The cross-correlation between the pumping volume and the minimum water level shows a maximum value 1 at a delayed time of 34 months. The cross-correlation between rainfall and the minimum water level shows a maximum value of 0.39 at a delayed time of 32 months.

  • PDF

Laser Microfabrication for Silicon Restrictor

  • Kim, Kwang-Ryul;Jeong, Young-Keun
    • 한국분말재료학회지
    • /
    • 제15권1호
    • /
    • pp.46-52
    • /
    • 2008
  • The restrictor, which is a fluid channel from a reservoir to a chamber inside a thermal micro actuator, has been fabricated using ArF and KrF excimer lasers, Diode-Pumped Solid State Lasers (DPSSL) and femtosecond lasers for a feasibility study. A numerical model of fluid dynamics for the actuator chamber and restrictor is presented. The model includes bubble formation and growth, droplet ejection through nozzle, and dynamics of fluid refill through the restrictor from a reservoir. Since an optimized and well-fabricated restrictor is important for a high frequency actuator, some special beam delivery setups and post processing techniques have been researched and developed. The effects of variations of the restrictor length, diameter, and tapered shapes are simulated and the results are analyzed to determine the optimal design. The numerical results of droplet velocity and volume are compared with the experimental results of a cylindrical-shaped actuator. It is found that the micro actuators having tapered restrictors show better high frequency characteristics than those having a cylindrical shape without any notable decrease of droplet volume. The laser-fabricated restrictors demonstrate initial feasibility for the laser direct ablation technique although more development is required.

Fluid Flow Characteristics in the Aquaculture Tank for a Breeding Fish

  • Jeong, Hyo-Min;Chung, Han-Shik;Kim, Se-Hyun;Choi, Seuk-Cheun;Bae, Kang-Youl
    • Journal of Mechanical Science and Technology
    • /
    • 제18권12호
    • /
    • pp.2265-2272
    • /
    • 2004
  • The aquaculture tank is used for breeding fish in sea water which was pumped up to land. The flow characteristics in the aquaculture were investigated with varying the tank geometry and flow rate. The numerical analysis has been employed for calculating the velocity and temperature distributions in a water tank of rectangular type. The finite volume method and SIMPLE algorithm with 3-dimensional standard $\kappa$-$\varepsilon$ turbulence model were used for the numerical analysis. For comparison with experimental results, the PIV system was applied to visualize the flow patterns quantitatively. The numerical results showed good agreements with the experimental results. The mean velocity and temperature versus aquarium depth were represented for various circulating flow rates. Especially, the aquaculture environment is recommended that the aquarium depth has to be d=0.5 m, and this case is the condition of higher velocity and temperature in winter season.

Experimental studies on stabilization techniques for ground over abandoned subsurface excavations

  • Pal Samir K.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.142-149
    • /
    • 2003
  • Blind hydraulic backfilling is a commonly used technique for subsidence control of the strata over unapproachable waterlogged underground excavations. In this investigation model studies on all the three variants of this technique, namely, hydro-pneumatic or air-assisted gravity backfilling, pumped-slurry backfilling and simple gravity backfilling, have been carried out in fully transparent models of the underground excavations. On examination of the filling process, it was revealed that in all the three cases, the basic process of filling occurs by sand transport along one or more meandering channels. The relative influence of sand, water and air flow rates on the area of filling from a single inlet point and the hydraulic pressure loss per unit length were studied in details. In hydro-pneumatic backfilling process, the air bubbles while moving upward through the meandering channels provide an additional buoyant force over and above the available hydraulic head. In this way the area of filling from a single borehole may be quite large even at small flow rates of water. During actual field implementation the injected air, if not released completely from the rise side holes, may cause troubles by way of creating potholes on the surface. The pumped-slurry technique has shown its capability of filling a relatively larger area at faster rate, especially when high-volume, low-pressure method was selected. But simple gravity filling was also found to be equally effective method as slurry pumping, especially when flow rates were high. In the second and third method discussed above, examination of variations of injection pressure was also done and its relation with physical phenomenon was also attempted. Some empirical relationships were also developed using multivariate regression with a view to help the practicing engineers.

  • PDF

물 자원 생산을 위한 Coal Seam Gas Water Management Study의 평가 및 분석 -1. 용수 생산 (Assessment and Analysis of Coal Seam Gas Water Management Study for Water Resource Production -1. Water Production)

  • 신춘환
    • 한국환경과학회지
    • /
    • 제23권8호
    • /
    • pp.1395-1407
    • /
    • 2014
  • Coal seam gas (CSG) production involves extracting methane from coal seams with ground water which is so called a primary by-product of this process, and is often rich in salts and other constituents. The predicted large volume and variable quality of this water make water management a topic associated with CSG production. In the past, the amount of this water used to be pumped into the vacant aquifer, or into the river during the life of individual production wells. Australian government make a strategies for management and beneficial use of the water. From this point of view, a detailed assessment has not been undertaken, it is necessary for water resource production to analysis the "Coal Seam Gas Water (CSG Water) Management Policy Study" published in Queensland, Australia.