A CASE STUDY ON INVESTMENT EVALUATION OF A PRIVATE SECTOR PROJECT WITH GEOTECHNICAL RISKS

  • Yoshiki Onoi;Hiroyasu Ohtsu
    • 국제학술발표논문집
    • /
    • The 1th International Conference on Construction Engineering and Project Management
    • /
    • pp.824-829
    • /
    • 2005
  • This paper focuses on construction cost volatility for the purpose of private sector investment by use of a financial model with key indices of IRR and DSCR (Debt Service Coverage Ratio). A case project, 1,000 MW pumped storage hydropower plant, has shown that its financial impacts by cost volatility of underground works are less measured than interest rates impacts by interest rate of loans. Probabilistic analysis of costs under geotechnical conditions has been made by Indicator Kriging method. And, in the modeling of interest rates, geometric Brownian motion has been applied. Both of these impacts are measured on the same financial model.

  • PDF

고낙차 수력 펌프/터빈 런너에 대한 모우드 실험 (Modal Testing on a High Head Pump/Turbine Runner)

  • 류석주;하현천;김호종
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.278-282
    • /
    • 1997
  • This paper describes results of modal testing for a high head pump-turbine runner of the Muju pumped storage power plant. The head of the pump-turbine is 601 m and the outside diameter of its runner is 4,410 mm. The modal testing was done for two conditions : 1) the runner in air ; 2) the runner in water. For both conditions, obtained are natural frequencies, corresponding mode shapes and damping ratios. From the testing, it is found that the natural frequencies of the pump-turbine runner in water is reduced approximately 40 % due to additional mass effect of the water.

  • PDF

관수온도 상승률 증가에 의한 발전용 보일러의 온간기동시간 단축에 관한 연구 (Warm Start Up Time Reduction Through the Increase of Boiler Water Circulating Pump Inlet Water Temperature Rate of the Thermal Power Plant)

  • 강희성;문승재
    • 플랜트 저널
    • /
    • 제10권1호
    • /
    • pp.47-53
    • /
    • 2014
  • 1887년 경복궁 건천궁에서 최초로 전기점등 행사를 시행한 이후 2012년 11월 기준의 대한민국 발전설비 용량은 81,737 MW, 그리고 2012년도 최대전력 수요는 71,230 MW로 이전기록을 경신한 바 있다. 이렇게 급속하게 증가하는 전력수요를 충족하기 위하여 정부에서는 대용량 유연탄 화력과 원자력발전소를 건설하여 운영 중에 있으나 전력수요는 주중에 집중되고 주말에는 급감하여 주말의 예비률이 40% 이상을 상회하고 있어 양수발전기를 이용하여 주말수요를 창출하는 한편 감소된 주말의 전력수요에 맞추어 서울화력발전소을 포함한 고원가 발전소에 대한 주말정지를 시행하고 있다. 서울화력발전소는 전력수요지의 중심지인 수도 서울에 위치하였음에도 발전원가가 높아 2008년도 이후 매년 30회 이상의 주말정지를 시행함으로 기동정지 과정에서 많은 비용을 지출하고 있어 본 연구에서는 1969년 준공하여 열병합설비로 개조한 서울화력발전소 제5호기를 대상으로 온간기동 과정에서 보일러 강제순환펌프 입구 관수온도 상승률을 증가시켜 온도상승 공정에 소요되는 시간을 약 35% 단축하고 기동시간 종합관리 프로그램을 구성하여 운영함으로써 전체적으로 온간기동 시간을 23% 단축할 수 있음을 확인하였다.

  • PDF

고낙차 수력 펌프/터빈 런너에 대한 진동 모드해석 및 실험 (Modal Analysis and Testing of a High Head Pump/Turbine Runner)

  • 류석주;하현천
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1062-1068
    • /
    • 1998
  • This paper describes the vibration characteristics of a high head pump-turbine runner. with nine blades and an outer diameter of 4.410 mm. of the pumped storage power plant. Mode shapes and natural frequencies were obtained by means of both the finite element analysis and modal testing. both in air and in water. The natural frequencies in air were calculated using the finite element method by ANSYS software. In order to confirm calculation results. the natural frequencies and mode shapes of the runner were measured using a hydraulic exciter both in air and in water. Natural frequencies of the pump-turbine runner were found at 174. 310 Hz in air, and at 107. 184 Hz in water. The first mode shape is flat plate mode with two nodal diameter and the second one is also flat plate mode with three nodal diameter. It can be shown that the natural frequencies of the pump-turbine runner in water is reduced approximately 40 % due to additional mass effect. Natural frequencies in air predicted by ANSYS software are in good agreement with test results.

  • PDF

Design of a Pump-Turbine Based on the 3D Inverse Design Method

  • Chen, Chengcheng;Zhu, Baoshan;Singh, Patrick Mark;Choi, Young-Do
    • 한국유체기계학회 논문집
    • /
    • 제18권1호
    • /
    • pp.20-28
    • /
    • 2015
  • The pump-turbine impeller is the key component of pumped storage power plant. Current design methods of pump-turbine impeller are private and protected from public viewing. Generally, the design proceeds in two steps: the initial hydraulic design and optimization design to achieve a balanced performance between pump mode and turbine mode. In this study, the 3D inverse design method is used for the initial hydraulic impeller design. However, due to the special demand of high performance in both pump and reverse mode, the design method is insufficient. This study is carried out by modifying the geometrical parameters of the blade which have great influence and need special consideration in obtaining the high performance on the both modes, such as blade shape type at low pressure side (inlet of pump mode, outlet of turbine mode) and the blade lean at blade high pressure side (outlet of pump mode, inlet of turbine mode). The influence of the geometrical parameters on the performance characteristic is evaluated by CFD analysis which presents the efficiency and internal flow results. After these investigations of the geometrical parameters, the criteria of designing pump-turbine impeller blade low and high sides shape is achieved.

모래 공급과 인공 홍수가 양양댐 하류하천의 부착조류에 미치는 영향 (Effects of Sand Supply and Artificial Floods on Periphyton in the Downstream of a Dam (Yangyang Dam, Korea))

  • 박미숙;이재용;정성민;박창근;장군;김범철
    • 한국물환경학회지
    • /
    • 제28권3호
    • /
    • pp.418-425
    • /
    • 2012
  • Dam construction in a river can change its hydrological pattern and trap sediments, which results in ecological changes in the downstream. It is a common phenomenon in the downstream of dams to have decreased sediment flow and increased periphyton. Artificial floods and sediment application are suggested as mitigation practices in order to simulate natural process of flood; transporting sediment and sloughing periphyton off. In this study the effects of artificial floods on periphyton were examined by applying sand artificially and discharging water from a dam (Yangyang Dam, Korea). The study area has been suffering from turbidity problems caused by shore erosion of the dam. The accumulation of inorganic sediments and increase of periphyton on the river bottom are the major factors of habitat deterioration in the downstream reaches. Artificial flood and artificial addition of sand was performed in summer and the effects were measured. Piles of applied sands were washed off easily by discharge and it enhanced the periphyton sloughing effect. The removal efficiency of periphyton was 50 ~ 80% within the 2 km reach from the dam. In conclusion artificial floods and sand application can be a good mitigation measure for the habitat rehabilitation after a dam construction in streams.

수위가 변동하는 휠댐의 안정성 해석(I) (Seepage Analysis of Rock -fill Dam Subjected to Water Level Fluctuation)

  • 이대수
    • 한국지반공학회지:지반
    • /
    • 제12권6호
    • /
    • pp.65-78
    • /
    • 1996
  • 한반도 중부지역에 위치한 청평양수발전소의 상부저수지는 준공후 16년이 경과한 사력댐으로 매일 수위 상승 및 저하를 경험하므로써, 제체의 거동이 일반 댐과는 달리 여러 가지 지반공학적 관심을 불러 일으키고 있다. 침투류에 대한 안정성을 판단하기 위하여 종래에는 심벽만을 대상으로 하여 저수지의 수위변동을 고수위 및 저수위의 두 경우로 고정시킨 정상상태의 해석을 주로 사용함에 따라 임의의 시간에서의 전체적인 침투현상 규명이 어려웠으나, 본 연구에서는 수위변동을 경계조건에 반영한 2차원 비정상류 유한요소해석을 댐 전체단면을 대상으로 수행하여 정상상태의 해석과 비교하였으며, 수위 변동에 따라 해당시간에서의 동수 경사, 침투력 벡타, 간극수압 등을 정량적으로 규명하였고, 산정된 침투수량을 계측치와 비필하였다. 그 결과 본 댐은 파이핑, 내부 침식 또는 제체 내부로의 투수 등에 대하여 안전하다고 판단된다.

  • PDF

양수발전댐의 홍수기 운영 기법 (PDH Matrix) 개발 (Development of flood operation technique (PDH Matrix) of pumped storage power plant dam)

  • 정창삼;김시영;이승오;이동엽
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.120-120
    • /
    • 2022
  • 우리나라 친환경 에너지 생산의 주요 축을 담당하고 있는 양수발전댐의 홍수 시 정교한 수계운영을 위한 방안으로 강우-유량-댐 수위 매트릭스(이하, PDH Matrix)를 개발하고 양수발전소상-하부댐 연계 운영에 따른 홍수 영향을 분석하였다. 연구 대상지역은 강원도 양양군 서면에 위치하고 있는 국내 최대 양수발전소인 양양양수 발전소로 총 저수용량 92만 m3의 콘크리트 중력식댐으로 유역면적은 약 125 km2이다. 양양양수 발전댐의 수계운영을 위한 PDH Matrix는 지속기간별 강수량 규모에 따른 홍수량 및 댐 최고수위 추정치를 판단할 수 있는 조견표로 강우규모 30 - 360 mm (30분 간격, 12개 강우규모) 및 지속기간 1-24시간 (1시간 간격, 24개 지속기간)인 총 288개의 강우조건별 홍수수문곡선을 개발하였다. 개발된 홍수수문곡선을 입력자료로 기존 댐 운영 방식인 AutoROM을 적용하여 저수지 홍수추적을 HEC-ResSim 모형으로 수행하고 최종적으로 개별 강우사상에 대한 강수량-유량-댐 수위 테이블을 작성하였다. 홍수기 댐 운영에 따른 최고수위는 초기 댐 수위조건에 따라 변동되므로 초기 댐 수위 조건(EL. 115 - 117 m, 1 m 간격)별 PDH Matrix를 각 각 개발하였다. 또한, 양수발전소의 특성상 상부댐으로 양수 또는 발전 방류에 따라 홍수 시 댐의 치수안전성에 미치는 영향이 크므로 상, 하부댐 운영에 따른 홍수영향 분석을 수행하였다. 구체적으로 하부댐에서 상부댐으로 양수 시 시간에 따른 하부댐 저수지의 수위변화 양상을 추정하였으며 극한적 홍수상황을 고려하기 위하여 상부 저수지가 만수인 상황에서 불가피하게 하부댐으로 방류가 필요한 상황에 대비한 홍수기 운영방안을 제안하였다. 본 연구는 하부댐-상부댐을 연계하여 운영하는 양수발전댐의 홍수기 수계 운영 방안을 수립한 첫 연구로 향후 연구에서 개발한 강우-유량-댐 수위 매트릭스(PDH Matrix) 작성 기법을 타 양수발전소 수계 운영 시 활용할 수 있을 것으로 기대된다.

  • PDF

지상레이저스캐너를 이용한 댐의 변위관측 (Deformation Measurements of Dam using Terrestrial Laser Scanner)

  • 박세훈;최득화;한동엽
    • 한국측량학회지
    • /
    • 제27권1호
    • /
    • pp.645-655
    • /
    • 2009
  • 삼랑진 양수발전소 상 하부댐 시설물에 매설되어 있는 기준점을 이용하여 댐의 변위에 대한 모니터링이 이루어지고 있다. 1997년, 2002년, 2007년에 이루어진 수직 및 수평 변위 관측방법은 기준점에 대한 비교분석을 통해 댐의 거동을 파악하였다. 전통적 측량방법으로는 댐체의 전체적인 거동을 세밀하게 분석하기 어려운 문제가 있으므로 본 연구에서는 지상레이저스캐너를 이용하여 댐체 표면을 관측하여, 스캔성과와 설계단면과의 비교분석을 통해 준공이후 현재까지의 댐체 변형을 추정하였다. 상부댐의 설계대비 수직변위량은 댐마루의 중간부분인 최대단면부에서 최대 1.5 m가 발생하였고, 하류사면에서는 중앙과중하위 부분인 SP4-2 부근에서 0.75 m, SP4-4 부근에서 0.5 m가 발생하였다. 하부댐의 설계대비 수직변위량의 최대 침하는 댐마루와 상류사면 상단부에서 발생하였고 침하량은 $-0.4\;m{\sim}-1.0\;m$ 범위로 분석되었다. 본 연구의 성과는 향후 댐체의 전체적인 거동을 분석하기 위한 초기치 설정 관측으로 이용될 수 있다.