• Title/Summary/Keyword: Pump system

Search Result 2,895, Processing Time 0.029 seconds

$^3H$-ouabain Binding in Heart Following Infusion of Ouabain in Rabbit (Ouabain 점적투여후 토끼심장에 있어서 $^3H$-Ouabain 결합에 관한 연구)

  • 김상건;김낙두
    • YAKHAK HOEJI
    • /
    • v.30 no.3
    • /
    • pp.149-156
    • /
    • 1986
  • Many experiments have showed that the sodium and potassium ion transporting system and the Na, $^+K^+$-ATPase activity of membrane fragments are inhibited by digitalis glycosides and that the pump may be associated with the pharmacological receptor for the drugs. The aim of our investigation is to elucidate the ouabain binding sites occupation in heart following infusion of ouabain to intact animals by the $^3H$-ouabain binding assay. Lethal dose and 26 percent of lethal dose of ouabain were infused to intact rabbit through ear vein. Microsomal fraction was fractionated from ouabain treated rabbit heart. $^3H$-ouabain binding to these fraction in vitro was studied by the Schwartz's method. $^3H$-ouabain binding to heart microsomal fraction was also studied following infusion of ginseng ethanol extract and caffeine to rabbits respectively. 1) The infusion of lethal dose ouabain (113$\mu\textrm{g}$/kg) inhibited the specific $^3H$-ouabain binding to rabbit heart microsomal fraction to the level of 60% (p<0.01) of control group and the infusion of 26% of lethal dose of ouabain led to the level of 79% (p<0.01) of the control group. 2) Time course of binding of 0.4$\mu{M}$ $^3H$-ouabain to microsomal fraction from rabbit heart following infusion of lethal and 26% of lethal dose of ouabain showed dose dependence at various incubation time. 3) Compared with control, only slight change of $K_d$ and $B_{max}$ was detected in in vitro $^3H$-ouabain binding after infusion of ginseng ethanol extract (300mg/kg) to rabbit. 4) In caffeine infusion group, $^3H$-ouabain binding yielded nearly the same results as control group.

  • PDF

Air-pressure Control of Diaphragm using Variable Frequency Current Control (가변 주파수 전류 제어에 의한 다이어프램의 압력제어)

  • Lim, Geun-Min;Lee, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.258-265
    • /
    • 2011
  • This paper presents a variable frequency current control scheme for the air-pressure control of diaphragm. Differ from the conventional air-pressure control of diaphragm, the proposed method uses a single-phase inverter to control the phase current and frequency. The phase current is adjusted to keep the reference air-pressure of the diaphragm. And the current frequency is changed to reduce the mechanical vibration. In order to smooth change of the operation with a constant air-pressure, the frequency is changed according to the voltage reference from the current controller. When the phase current is satisfied to the constant air-pressure, the current frequency is increased to reduce the vibration of the diaphragm. When the reference voltage to keep the phase current is over than the set value, the current frequency is decreased to keep the air-pressure. The proposed control scheme is verified by the experimental test of a commercial diaphragm.

Experimental Study on Characteristics of Evaporation Heat Transfer of CO2 in a Smooth Tube (평활관에서 이산화탄소의 증발열전달 특성에 관한 실험연구)

  • Lee, Sang-Jae;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Journal of Energy Engineering
    • /
    • v.16 no.4
    • /
    • pp.181-186
    • /
    • 2007
  • In order to investigate the heat transfer coefficient and pressure drop during evaporation of $CO_2$, basic experiment on the evaporation heat transfer characteristics in a horizontal smooth tube was performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes ($200{\sim}1200\;kg/m^2s$), heat fluxes ($10{\sim}80\;kW/m^2$) and saturation temperatures ($-5{\sim}5^{\circ}C$). With the increase of quality, the evaporation heat transfer coefficient decreased. With the increase of heat flux, the evaporation heat transfer coefficient increased. Significantly change of the heat transfer coefficient was observed at any heat flux and mass flux. With the increase of saturation temperature, the heat transfer coefficient increased. Pressure drop increased with the increase of mass flux and the decrease of saturation temperature.

Three Dimensional Electro-Fluid-Structural Interaction Simulation for Pumping Performance Evaluation of a Valveless Micropump (무밸브 마이크로 펌프의 성능평가를 위한 3차원 전기-유체-구조 상호작용 해석)

  • Pham, My;Phan, Van Phuoc;Han, Cheol-Heui;Goo, Nam-Seo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.8
    • /
    • pp.744-750
    • /
    • 2009
  • In this study, the pumping performance of a piezoelectric valveless micropump is simulated. The micropump, which was developed in the previous work, is composed of a four-layer lightweight piezocomposite actuator, a polydimethylsiloxane (PDMS) pump chamber, and two diffusers. The piezoelectric domain, the fluid domain and the structural domain are coupled in the three-dimensional simulation. We used ANSYS for the piezoelectric and structural domains and ANSYS CFX for the fluid domain. The effects of driven frequency on the flow rate have been investigated by simulating the flow characteristics for 10 Hz and 40 Hz driven frequencies. The flow rates with respect to driven frequencies up to 300 Hz have been calculated.

Development of wall climbing robot using vacuum adsorption with legged type movement (진공 흡착과 보행형 이동에 의한 벽면이동 로봇의 개발)

  • Park, Soo-Hyun;Seo, Kyeong-Jun;Kim, Sung-Gaun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.344-349
    • /
    • 2017
  • Wall-climbing robots have been developed for various purposes, such as cleaning skyscraper windows, maintaining large structures, and welding vessels. Conventional wall-climbing robots use movement systems based on wheels or legs. However, wheeled robots suffer from slipping effects, while legged systems require many actuators and control systems for the complex linkage structure, which also increases the weight of the robot. To overcome these disadvantages, we propose a new wall-climbing robot that walks based on gorilla locomotion. The proposed robot consists of a DC drive motor, a vacuum pump for adsorption, and a micro controller for controlling the system. The performance of the robot was experimentally verified on vertical and horizontal flat surfaces. The robot could be used for various functions in industrial sites or disaster areas.

Development of a Data Structure for Effective Monitoring of Power Plant Start-up Sequences (화력 발전소의 기동 시퀀스 진행 모니터링을 위한 자료구조 개발)

  • Lee, Seung-Chul;Han, Seung-Woo;Kim, Seung-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.224-232
    • /
    • 2009
  • Power plant start-up is a complicate process involving hundreds of operations that should be performed either automatically or manually. Several major operations should be proceeded in parallel and each major operation is again broken down into detailed operations that must be carried out in a strict sequence. Even though most of the operations are automated, still substantial portions of the operations are carried out manually and the operational status should be monitored by the crew members, which are quite stressful tasks to be performed in real time. In this paper, a data structure called an Event Sequence Monitoring Graph(ESMG) is proposed for monitoring a sequence of events involved in the power plant start-up process. The ESMG is currently being applied to a thermal power plant with a rated output of 500MW. An application example is shown with the boiler feed water pump system start-up process, which exhibits a good potential for future applications.

Human Error Probability Assessment During Maintenance Activities of Marine Systems

  • Islam, Rabiul;Khan, Faisal;Abbassi, Rouzbeh;Garaniya, Vikram
    • Safety and Health at Work
    • /
    • v.9 no.1
    • /
    • pp.42-52
    • /
    • 2018
  • Background: Maintenance operations on-board ships are highly demanding. Maintenance operations are intensive activities requiring high man-machine interactions in challenging and evolving conditions. The evolving conditions are weather conditions, workplace temperature, ship motion, noise and vibration, and workload and stress. For example, extreme weather condition affects seafarers' performance, increasing the chances of error, and, consequently, can cause injuries or fatalities to personnel. An effective human error probability model is required to better manage maintenance on-board ships. The developed model would assist in developing and maintaining effective risk management protocols. Thus, the objective of this study is to develop a human error probability model considering various internal and external factors affecting seafarers' performance. Methods: The human error probability model is developed using probability theory applied to Bayesian network. The model is tested using the data received through the developed questionnaire survey of >200 experienced seafarers with >5 years of experience. The model developed in this study is used to find out the reliability of human performance on particular maintenance activities. Results: The developed methodology is tested on the maintenance of marine engine's cooling water pump for engine department and anchor windlass for deck department. In the considered case studies, human error probabilities are estimated in various scenarios and the results are compared between the scenarios and the different seafarer categories. The results of the case studies for both departments are also compared. Conclusion: The developed model is effective in assessing human error probabilities. These probabilities would get dynamically updated as and when new information is available on changes in either internal (i.e., training, experience, and fatigue) or external (i.e., environmental and operational conditions such as weather conditions, workplace temperature, ship motion, noise and vibration, and workload and stress) factors.

The Effect of Construction Methods on Geothermal Exchange Rates of Cast-in-place Energy Piles (현장타설말뚝형 에너지 파일의 시공형태별 지중 열교환량에 관한 연구)

  • Park, Yong-Boo;Nam, Yu-Jin;Sim, Young-Jong;Sohn, Jeong-Rak
    • Land and Housing Review
    • /
    • v.3 no.2
    • /
    • pp.169-175
    • /
    • 2012
  • In recent, there are many studies associated with energy piles to save initial construction cost for ground source heat pump system. In this study, to evaluate geothermal exchange rates two types (a connection type and a slinky type) of cast-in-place energy piles (PRD, 4.5m in depth, 1,200 mm in diameter) were constructed for the tests and their efficiencies were compared with numerical analysis results. As a result, starting with operation, geothermal exchange rate gradually decreases due to exchange of lower ground temperature. In the case of connection type, temperature difference is $0.37^{\circ}C$ in heating mode and $0.34^{\circ}C$, in cooling mode, respectively. In addition, in case of a connection type, geothermal exchange rate in heating mode is 2,314W/m and in cooling mode, 252.2W/m whose value is 9% higher than in heating mode. In the case of slinky type, the average geothermal exchange rate in heating mode is 168.0W/m, which is about 27% lower than that of connection type.

건식 진공펌프의 상태진단을 위한 PMS 프로그램 개발

  • Jeong, Wan-Seop;Im, Jong-Yeon;Nam, Seung-Hwan;Kim, Hak-Seung;No, Myeong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.106.2-106.2
    • /
    • 2013
  • 본 논문은 반도체 및 평판 디스플레이 생산공정에서 가동되고 있는 건식 진공펌프들의 정밀 상태진단 및 예지 보수를 위한 pump monitoring system (PMS)의 제품화에 필요한 프로그램의 개발 내용을 소개한다. 본 연구에서 소개하는 건식 진공펌프들의 정밀 상태진단 및 예지보수기법은 PCT 특허 2 건으로 이미 등록된 내용이며, 본 논문은 이들 기법의 실제 구현에서 직면하는 기술적 문제점과 극복 방안을 제시한다. 본 논문에서는 현재 반도체 공정에 사용되고 있는 건식 진공펌프들로부터 측정하는 다중 상태변수들의 조사 결과를 소개한다. 이들 상태변수 측정치들이 갖는 개략적 특성을 통계적 분포함수로 분석한 결과를 우선 보인다. 특히 펌프 구동모터들의 소비 전류신호는 두 평균값에 대한 분포 즉 두 종의 분포함수를, 그리고 온도, purge gas 유량, 배기구 압력 등은 정상적 평균값에 대한 한나의 분포를 보였다. 따라서 구동모터들의 소비전류의 분포 즉 두 상하 수준('low and high' current level)에 따라 batch data를 구분하는 방법의 개발이 필요하였다. 본 연구에서는 step 함수형 eigenvector를 적용하여 소비전류 신호의 상하수준 천이 영역과 방향을 동시에 인식할 수 있는 기법을 개발 적용하였으며, 3300회의 배출가스 부하에 변화에 대한 천이 영역과 방향을 인식에 하나의 실패도 보이지 않음을 확인하였다. 기존의 측정 상태변수에는 회전기계류의 정밀 상태진단 및 예지보수에 핵심적인 기계진동 측정용 진동센서를 포함하고 있지 않은 기술적 문제점이 발견되었다. 기존 진동센서들의 높은 가격 뿐 아니라 진동센서의 출력신호를 저/중/고역 주파수 대역의 실효치로 환산하는 기술적 한계 때문에 진공펌프 상태진단에 아직 사용하고 있지 않고 있다. 본 연구에서는 진동선서 비용의 저감화 방안뿐 아니라 로터 회전 대역(250Hz 이하 저주파 영역), 베어링 진동 대역(250 Hz~2.5 kHz의 중간 주파수 영역), 그리고 기어 진동 대역(2.5 kHz~10 kHz 주파수 영역)별 실효치를 실 시간 측정할 수 있는 진동측정 모듈의 제품화 모델을 개발하였다. 개발 제품의 성능 뿐 아니라 현장 시험결과를 소개한다. 마지막으로 본 연구팀이 개발한 PCT 특허 2 건에 포함된 건식 진공펌프들의 정밀 상태진단 및 예지보수기법에 대한 현장 시험결과를 간략히 소개한다.

  • PDF

A Study on the Fire Safety Measure of Pumped Storage Power Plant (양수발전소의 화재안전 대책에 관한 연구)

  • Kim, Yoo-Shik
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.125-130
    • /
    • 2006
  • Pumped storage power plant is a system of generating electricity with hydroelectric power, in which at times of low electrical demand such as during nights, excess generation capacity of many power plants is used to pump water into the higher reservoir, and when there is higher demand, water is released back into the lower reservoir through a turbine, generating electricity. As pumped storage power plants across the nation are not on building registry under "the Article 6 of the Special Act by the Development of Power Resources", they are classified as a structure, not as a building. As a result, permit of fire protection facility is unnecessary, and fire protection administration is excluded from approval to completion of construction. Therefore, this study is to improve problems in accordance with the application of "he Article 6 of the Special Act by the Development of Power Resources", repair of facilities and problems with safety control to effectively prevent similar damages from repeatedly happening to pumped storage power plants in operation or under construction nationwide during a fire.