• 제목/요약/키워드: Pump intake

검색결과 86건 처리시간 0.03초

PIV에 의한 흡입수조내 흡입관 주위의 유동특성에 관한 연구 (Study on Flow Characteristics around Intakes within a Sump by PIV)

  • 최종웅;김정환;남청도;김유택;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.563-569
    • /
    • 2001
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and no stray currents, Hence, flow into the pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. But various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall and back-wall due to different clearances from back-wall to vertical in take pipe. Moreover, the locations and vorticities of the various types of vortices that were found in the examinations are discussed.

  • PDF

흡수정의 유동해석 (Flow analysis of the Sump Pump)

  • 정한별;노승희
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.673-680
    • /
    • 2017
  • 흡수정은 댐이나 저수지에 저장된 물을 흡입하여 사용하는 설비이다. 흡입한 다량의 물은 화력 및 원자력 등의 대형 발전소의 냉각시스템에 사용된다. 특징으로 흡입 유량과 흡수정의 비가 작으면 흡입구 주변에서 유속이 증가한다. 이로 인해 와류나 선회류의 불균형 유동이 발생된다. 불균형 유동은 흡수정의 성능을 저하나 고장의 원인이 된다. 해결하기 위한 다양한 방법이 고안되고 있으나 최저수위 일 경우 정확한 해결 방법을 찾지 못하고 있다. 가장 효율적인 해결방법으로는 AVD를 설치하거나 관로를 길게하는 방법이 있다. 이렇게 설치된 구조물이 유동의 흐름을 균일하게 만들어 주기 때문이다. 본 논문에서는 관로의 길이와 AVD의 형태 변화에 따른 흡수정 내의 유동특성을 수치해석으로 분석한다. 수치해석을 위하여 수정의 흡입부, 섬프, 펌프의 3단계로 분리하여 모델링하였다. 격자는 해석의 정확도를 위해 흡입부는 비조밀, 흡수정과 AVD는 조밀하게 하였다. ANSYS ICEM-CFD 14.5를 이용하여 120~150만개의 격자를 생성하였고 Tetra grid와 Prism grid를 혼용하였다. 해석을 위해 상용 CFD 프로그램인 ANSYS CFX14.5의 SST 난류모델을 선정하였다. 조건으로 H.W.L 6.0m, L.W.L 3.5, Qmax 4.000 kg/s, Qavg 3.500 kg/s Qmin 2.500 kg/s로 설정하였다. 보텍스 각도와 속도분포로 해석한 결과는 다음과 같다. Ext E-type의 AVD를 설치한 흡수정이 최고수위 일때 합격하였다. 추후, Ext E-type을 기본으로 하여 최저수위일 때 만족하는 연구가 필요하다.

취수 펌프용 고압전동기(6.6 kV, 3,800 kW)의 소손원인 분석 (Damage Analysis of High Voltage Motor for Intake Pump)

  • 오민환;이은춘;홍성택;이상군
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1324-1326
    • /
    • 1999
  • This paper demonstrates the insulation-destruction of high-voltage-motors for intake pump. To analyze the causes of damage in motors, electrical, mechanical and environmental fiery-development were investigated. The insulation-destruction of high-voltage-motors are generally due to the fiery-stress by void where composite materials such as mica/epoxy are used. But this paper shows that electrical and mechanical stresses can be the main reason of the damage, too.

  • PDF

소독능을 고려한 송수펌프 최적운영기법 개발 (Development of the method for optimal water supply pump operation considering disinfection performance)

  • 형진석;김기범;서지원;김태현;구자용
    • 상하수도학회지
    • /
    • 제32권5호
    • /
    • pp.421-434
    • /
    • 2018
  • Water supply/intake pumps operation use 70~80% of power costs in water treatment plants. In the water treatment plant, seasonal and hourly differential electricity rates are applied, so proper pump scheduling can yield power cost savings. Accordingly, the purpose of this study was to develop an optimal water supply pump scheduling scheme. An optimal operation method of water supply pumps by using genetic algorithm was developed. Also, a method to minimize power cost for water supply pump operation based on pump performance derived from the thermodynamic pump efficiency measurement method was proposed. Water level constraints to provide sufficient disinfection performance in a clearwell and reservoirs were calibrated. In addition, continuous operation time constraints were calibrated to prevent frequent pump switching. As a result of optimization, savings ratios during 7 days in winter and summer were 4.5% and 5.1%, respectively. In this study, the method for optimal water pump operation was developed to secure disinfection performance in the clearwell and to save power cost. It is expected that it will be used as a more advanced optimal water pump operation method through further studies such as water demand forecasting and efficiency according to pump combination.

취수장용 펌프 및 배관 진동 분석 사례 (The Analysis of Vibration with Pump and Pipe for Intake Station)

  • 최병근;최창림;김효중;구동식;정한얼
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.200-204
    • /
    • 2005
  • A few intake stations have vibration problems caused by pumps, motors and pipes. The vibration transffered from pumps, motors and pipes excites buiding severely. Therefore, the crack is generated on building wall and people who work at intake station are damaged. In this paper, the vibration and noise have been measured and analyzed for pumps, motors, pipes and building at intake station. Also, the cause of vibration and noise is identified. Finally, the reference of vibration and noise is established using results of measurement.

  • PDF

자당 및 탄산음료 섭취 후 생성되는 구강 내 치아우식 유발성 유기산의 농도 차이 (The concentration differences of dental caries induced organic acids which are produced after intake of sucrose and carbonated drinks)

  • 박정은;장종화
    • 한국치위생학회지
    • /
    • 제17권3호
    • /
    • pp.381-394
    • /
    • 2017
  • Objectives: This study aims to evaluate carbonated drinks induced dental caries with qualitative analysis and to compare with oral organic acids including lactate, acetate, propionate, formate, butyrate, pyruvate and valerate which cause caries when taking either 10% sucrose drinks or carbonated drinks. Methods: Saliva was collected from six study subjects before and after (start, 5, 10, 30 minutes) taking water intake upon (A) 10% sucrose intake, (B) 10% sucrose intake, and (C) carbonated drink intake, then they were centrifuged at 1,200 rpm followed by removing bacteria and enzymes with syringe filtering, performing a qualitative analysis with HPLC conductivity detection (GP50 gradient pump, ED 50 detector) after saliva pre-treatment under isocratic 100 mM NaOH mobile phase. Results: Higher risk of dental caries was evaluated in order of C>B>A, with the results of total oral organic acids' concentration, lactates of organic acids and organic acids produced after 5 minutes from the 3 types of drinks intake. Conclusions: Carbonated beverages were estimated to develop higher dental caries induction than beverages containing 10% sucrose because of the high organic acid concentration in the mouth after its intake.

자동차용 LPG 연료펌프의 윤활성 개선에 관한 연구 (A Study on the Improvement of Lubrication Characteristics for Fuel Pump in LPG Engine)

  • 김창업;최교남;강건용;박철웅
    • 한국분무공학회지
    • /
    • 제16권1호
    • /
    • pp.1-6
    • /
    • 2011
  • In recent years, the need for more fuel-efficient and lower-emission vehicles has driven the technical development of alternative fuels such as LPG (Liquefied Petroleum Gas) which is able to meet the limits of better emission levels without many modifications to current engine design. LPG has a high vapor pressure and lower viscosity and surface tension than diesel and gasoline fuels. These different fuel characteristics make it difficult to directly apply the conventional gasoline or diesel fuel pump. Self acting lubricated groove design or coating can be used in high-speed and high precision spindle system like a roller-vane type fuel pump, because of its advantages such as low frictional loss, low heat generation, averaging effect leading better running accuracy and simplicity in manufacturing. Those design method can also affect the atomization of fuel from the injector and the formation of fuel film on the intake manifold. In this study, experiments are carried out to get performance characteristics of initial and steady state operation, The characteristics of vane type fuel pump were investigated to access the applicability on LPLi engine.

AN INVESTIGATION OF SURFACE VORTICES BEHAVIOR IN PUMP SUMP

  • Kang, Won-Tae;Shin, Byeong-Rog
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.592-595
    • /
    • 2011
  • A numerical investigation on a suction vortices, free vortices and subsurface vortices behavior in the model sump system with multi-intakes is performed A test model sump and piping system were designed based on Froude similitude for the prototype of the recommended structure layout by HI-9.B Standard for Pump Intake Design of the Hydraulic Institute. A numerical analysis of three dimensional multiphase flows through the model sump is performed by using the finite volume method of the CFX code with multi-block structured grid systems. A ${\kappa}-{\omega]$ ShearStressTransportturbulencemodelandthe Rayleigh-Plesset cavitation model are used for solving turbulence cavitating flow. From the numerical analysis, several types of vortices are reproduced and their formation, growing shedding and detailed vortex structures are investigated. To reduce abnormal vortices, an anti-vortex device is considered and its effect is investigated and discussed.

  • PDF