• Title/Summary/Keyword: Pump array

Search Result 35, Processing Time 0.022 seconds

Performance Evaluation of Backwash Hydrodynamic Separator Filter for Treatment of Micro Particles (역세척 Hydrodynamic Separator Filter를 이용한 미세입자 제거 특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.10
    • /
    • pp.694-701
    • /
    • 2012
  • The main purpose of this study is to evaluate of backwash system of hydrodynamic separator filter (HSF) with solar powered submerged pumps. It consists of a photovoltaic solar array, control electronics, battery, and two submersible pump powered by a 12 voltage DC motor. The laboratory scale study on treatable potential of micro particles using backwash HSF that was a combined with perlite filter cartridge and backwash nozzles. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particle sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin partices, silica gel particles, and commercial area manhole sediment particles. HSF was made of acryl resin with 250 mm of diameter filter chamber and overall height of 800 mm. Four case test were performed with different backwashing conditions and determined the SS removal efficiency with various surface loading rates. The operated range of surface loading rate was about 308~$1,250m^3/m^2/day$. It was found that SS removal efficiency of HSF using two submersible pumps improved by about 18% compared with HSF without backwash. Nonpoint control devices with solar water pumping systems would be useful for backwashing the filter in areas with not suppling electricity and reduce filter media exchange cost.

Design of MTP memory IP using vertical PIP capacitor (Vertical PIP 커패시터를 이용한 MTP 메모리 IP 설계)

  • Kim, Young-Hee;Cha, Jae-Han;Jin, Hongzhou;Lee, Do-Gyu;Ha, Pan-Bong;Park, Mu-Hun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.1
    • /
    • pp.48-57
    • /
    • 2020
  • MCU used in applications such as wireless chargers and USB type-C require MTP memory with a small cell size and a small additional process mask. Conventional double poly EEPROM cells are small in size, but additional processing masks of about 3 to 5 sheets are required, and FN tunneling type single poly EEPROM cells have a large cell size. In this paper, a 110nm MTP cell using a vertical PIP capacitor is proposed. The erase operation of the proposed MTP cell uses FN tunneling between FG and EG, and the program operation uses CHEI injection method, which reduces the MTP cell size to 1.09㎛2 by sharing the PW of the MTP cell array. Meanwhile, MTP memory IP required for applications such as USB type-C needs to operate over a wide voltage range of 2.5V to 5.5V. However, the pumping current of the VPP charge pump is the lowest when the VCC voltage is the minimum 2.5V, while the ripple voltage is large when the VCC voltage is 5.5V. Therefore, in this paper, the VPP ripple voltage is reduced to within 0.19V through SPICE simulation because the pumping current is suppressed to 474.6㎂ even when VCC is increased by controlling the number of charge pumps turned on by using the VCC detector circuit.

Mechanical Properties of a High-temperature Superconductor Bearing Rotor in a 10 kWh Class Superconductor Flywheel Energy Storage System (10 kWh급 초전도 베어링 회전자의 기계적 특성 평가)

  • Park, B.J.;Jung, S.Y.;Kim, C.H.;Han, S.C.;Park, B.C.;Han, S.J.;Doo, S.G.;Han, Y.H.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.58-63
    • /
    • 2011
  • Recently, superconductor flywheel energy storage systems (SFESs) have been developed for application to a regenerative power of train, a power quality improvement, the storage of distributed power sources such as solar and wind power, and a load leveling. As the high temperature superconductor (HTS) bearings offer dynamic stability without the use of active control, accurate analysis of the HTS bearing is very important for application to SFESs. Mechanical property of a HTS bearing is the main index for evaluating the capacity of an HTS bearing and is determined by the interaction between the HTS bulks and the permanent magnet (PM) rotor. HTS bearing rotor consists of PM and iron collector and the proper dimension design of them is very important to determine a supporting characteristics. In this study, we have optimized a rotor magnet array, which depends on the limited bulk size and performed various dimension layouts for thickness of the pole pitch and iron collector. HTS bearing rotor was installed into a single axis universal test machine for a stiffness test. A hydraulic pump was used to control the amplitude and frequency of the rotor vibration. As a result, the stiffness result showed a large difference more than 30 % according to the thickness of permanent magnet and iron collector. This is closely related to the bulk stiffness controlled by flux pining area, which is limited by the total bulk dimension. Finally, the optimized HTS bearing rotor was installed into a flywheel system for a dynamic stability test. We discussed the dynamic properties of the superconductor bearing rotor and these results can be used for the optimal design of HTS bearings of the 10kWh SFESs.

Cooling characteristics of the multichip module using paraffin slurry (파라핀 슬러리를 사용한 다칩모듈의 냉각특성)

  • Jo, Geum-Nam;Choe, Min-Gu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.6
    • /
    • pp.888-898
    • /
    • 1998
  • The present study investigated the effects of the experimental parameters on the cooling characteristics of the multichip module cooled by the indirect liquid cooling method using water and paraffin slurry. The experimental parameters are mass fraction of 2.5 ~ 7.5% for paraffin slurry, heat flux of 10 ~ 40 W/cm$^{2}$ for the simulated VLSI chips and Reynolds numbers of 5,300 ~ 15,900. The apparatus consisted of test section, paraffin slurry maker, pump, constant temperature baths, flowmeter, etc. The test section made of in-line, four-row array of 12 heat sources for simulating 4 * 3 multichip module which was flush mounted on the top wall of a horizontal rectangular channel with the aspect ratio of 0.2. The inlet temperature was 20 deg. C for all experiments. The size of paraffin slurry was constant as 10 ~ 40 .mu.m befor and after the experiment. The chip surface temperatures for paraffin slurry with the mass fraction of 7.5% showed lower by 16 deg. C than those for water when the heat flux is 40 W/cm$^{2}$. The local heat transfer coefficients for the paraffin slurry with the mass fraction of 7.5% were larger by 17 ~ 25% than those for water at the first and the fourth row. The local heat transfer coefficients reached to a row-number-independent, thermally fully developed value approximately after the third row. The local Nusselt numbers at the fourth row for paraffin slurry with the mass fraction of 7.5% were larger by 23 ~ 29% than those for water.

Effect of FSH Pretreatment on Follicle Development and Oocyte Recovery by Ultrasound-guided Aspiration in Holstein Heifers (젖소의 초음파 유도 채란율에 대한 FSH 전처리 효과의 비교)

  • Park, Chung-Saeng;Jo, Seong-Geun;Lee, Jeong-Gyu;Gang, Tae-Yeong;Park, Seong-Jae;Gong, Il-Geun;Choe, Min-Cheol
    • Korean Journal of Animal Reproduction
    • /
    • v.21 no.2
    • /
    • pp.147-156
    • /
    • 1997
  • Ultrasound-guided follicular aspiration was performed in Holstein heifers once weekly with or without pretreatment of single or multiple decreasing doses using a total of 400 mg FSH. Oocytes were aspirated with a 6.5 MHz convex-array ultrasound trasducer designed for intravaginal use. All the visible follicles larger than 4 mm in diameter were punctured with a 17 gauge, 55 cm needle at each aspiration session and the follicular fluids containing oocytes were obtained by vacuum suction. The results obtained were as follows: As a preliminary experiment, the recovery rates of folicular oocytes by ultrasound-guided aspiration from the isolated ovaries of Korean native cows were compared between suction methods using manual syringe or vacuum pump. The recovery rate of oocytes using vacuum pump (80.7%) was significantly (P<0.05) higher than that using manual syringe (47.1%). The follicles were counted by their size in diameter with ultrasound image, and recovery rates and grades of follicular oocytes collected by ultrasound-guided aspiration were investigated in Holstein heifers pretreated with or without FSH. A group of heifiers were injected with multiple decreasing doses (twice a day for 3 days) of a total of 400 mg FSH. The other 2 groups were injected with a single dose of 400 mg FSH mixed with 25% PVP. Ultrasound observation of follicle population and/or ultrasound-guided transvaginal oocyte aspiration were performed 12 hrs following the last FSH injection in the multiple dose group, and 48 or 60 hrs after FSH injection in the single dose groups. Most of the visible follicles had small size of less than 3 mm in diameter in unstimulated heifers (71.0%), but medium size in all the heifers treated with FSH. (70.5 to 92.8%). The number of OPU follicles per session (4.6$\pm$1.9) were much less, compared to the vilsible follicle counts (9.7$\pm$2.2), in the nustimulated heifers due to the small dominant follicles. Among 4 goups of heifers the most visible as well as OPU follicles were observed in the heifers at 60 hrs following treatment of a single dose of 400 mg FSH (21.2$\pm$2.3 and 21.0$\pm$2.0), and the differences in both the follicle counts between the groups was found significant (P<0.05) The rates of oocyte recovery from the follicles by ultrasound-guilded aspiration were varied 46.3 to 75.0% in the heifers unstimulated and treated with a single dose of 400 mg FSH, but the group difference was not significant. The number of recovered oocytes per session a, pp.ared to be highest at aspiration at 60 hrs following single FSH (10.6$\pm$2.2) than at aspiration at 48 hrs after single FSH (7.8$\pm$2.7) or in the unstimulated heifers (3.4$\pm$3.0). The proportion of grade I and II oocytes to all oocytes collected was varied 31.8 to 64.0% between the groups. However, there was found no significant difference in both the number of oocytes recovered per session and the percentage and the percentage of grade I and II oocytes. From the above results it was concluded that the more oocytes of superior quality might be recovered economically by ultrasound-guided aspiration at 60 hrs following the pretreatment of a single dose of 400 mg FSH and by suction using a vacuum pump system of about negative pressure of 75 to 85 mmHg.

  • PDF