• 제목/요약/키워드: Pump Monitoring

검색결과 190건 처리시간 0.022초

인후두역류의 약물치료 (Medical Treatment of Laryngopharyngeal Reflux)

  • 주형로
    • 대한후두음성언어의학회지
    • /
    • 제18권2호
    • /
    • pp.108-112
    • /
    • 2007
  • Otolaryngological manifestations of acid reflux include a wide range of pharyngeal and laryngeal symptoms ; and the constellation of symptoms has been called laryngopharyngeal reflux (LPR). In the absence of definite diagnostic criteria, LPR disease remains a subjective entity. A diagnosis of LPR is usually based on response of symptoms to empirical treatment. Investigative modalities such as pH monitoring and, more recently, impedance studies are generally reserved for treatment failures. LPR usually requires more aggressive and prolonged treatment to achieve regression of both symptoms and laryngeal findings. The suppression of gastric acid and secretion with anti-secretary agents has been the mainstay of medical treatment for patients with acid-related disorders. The suppression of gastric acid secretion achieved with Hz-receptor antagonist $(H_2RA)$ has proved suboptimal for relief of reflux symptoms. The rapid development of tolerance and rebound acid hypersecretion after the with-drawal of $H_2RA$ limit their clinical use. Proton pump inhibitors (PPI) have been proved to be very effective for suppressing intragastric acidity, but the optimal dose and duration is unknown. Current evidence indicates that pharmacologic intervention should include, at a minimum, a 3 month trial of twice daily PPI. Symptoms of LPR improve over 2 months of therapy. The physical findings of LPR resolve more slowly than the symptoms and this continues through out at least 6 months of treatment. For most patients with LPR, twice daily dosing with a PPI is usually recommended for an initial treatment for a period of no less than 6 months treatment, and lifetime treatment may be required.

  • PDF

해저유기퇴적물 수거시스템의 실험 및 수치해석 (Experiments and Numerical Analysis on a System for Collecting Organic Sediment from Seabed)

  • 김도정;박제웅;정우철;김성근
    • 해양환경안전학회지
    • /
    • 제14권1호
    • /
    • pp.15-20
    • /
    • 2008
  • 오염된 퇴적물은 연안의 생태계 파괴에 근본적인 원인이 되고 있음에 따라, 선진 외국에서는 1960년대부터 이러한 문제 해결을 위한 새로울 기술개발을 진행하여 오고 있다. 본 연구에서는 유기퇴적물 수거를 위한 시스템 설계 및 개발에 있어서 오탁확산에 의한 2차 오염을 방지하거나 최소화 할 수 있는 Pilot 규모 형태의 흡입식 펌프 준설 시스템을 설계 제작하였으며, 시스템의 성능시험을 통한 적용 가능성을 제시하였다. 시스템 최적화를 위하여 수치해석기법을 통한 퇴적물 수거 시스템의 형상에 대한 성능평가를 수행하고, 제작 시스템의 성능시험에 있어서는 시스템의 정지 상태와 이동 상태에서의 퇴적물 수거 성능에 대한 실험을 수행하였다. 본 연구를 통하여 해저 유기퇴적물의 상부만을 준설할 수 있는 시스템의 개발 가능성을 확인하였다.

  • PDF

개별 부하 시스템의 에너지 절감을 포함한 선박 전력 에너지 관리 시스템 개발 (Development of Power Energy Management System for Ships including Energy Saving of Separated Load Systems)

  • 강영민;오진석
    • 한국정보통신학회논문지
    • /
    • 제22권1호
    • /
    • pp.131-139
    • /
    • 2018
  • 최근 4차 혁명과 연계하여 많은 선박 분야의 연구들이 수행되고 있으며, 그 중 하나로 에너지 관리시스템 (EMS: Energy Management System)이 관심을 받고 있다. 에너지 관리시스템은 선박의 에너지를 관리하기 위한 시스템을 통칭하며, 다양한 시스템을 포함한다. 본 논문에서는 선박에서의 에너지 절감 분야를 분석하고, 기관실에서 에너지 절감이 가능한 개별 부하 제어 시스템을 포함한 선박 전력 에너지 관리 시스템을 제안한다. 제안하는 EMS는 PCS (Pump Control System), ERFCS (Engine Room Fan Control System), LCS (Load Control System), HVACS (Heating, Ventilation, Air conditioning Control System)의 개별 부하 제어 시스템을 포함한다. 1차적으로, 제안하는 EMS는 기관실의 개별적인 부하 시스템에서 에너지를 절감한다. 2차적으로는 통합 모니터링 및 제어 시스템을 통해 발전 시스템과 전력 부하 시스템을 적절히 제어하여 에너지를 절감한다.

아톨바스타틴과 니페디핀의 약물동태학적 상호작용 (Pharmacokinetic Interaction Between Atorvastatin and Nifedipine)

  • 문홍섭;최준식
    • 한국임상약학회지
    • /
    • 제20권1호
    • /
    • pp.25-29
    • /
    • 2010
  • The purpose of this study was to investigate the effect of atorvastatin on the pharmacokinetics of nifedipine (6 mg/kg) after oral administration of nifedipine with or without atorvastatin (0.5 and 2.0 mg/kg) in rats, and also was to evaluate to the effect of atorvastatin on the CYP3A4 activity. The 50% inhibiting concentration ($IC_{50}$) values of atorvastatin on CYP3A4 activity is 46.1 ${\mu}M$. Atorvastatin inhibited CYP3A4 enzyme activity in a concentration-dependent manner. Coadministration of atorvastatin increased significantly (p<0.05, 2.0 mg/kg) the plasma concentration-time curve (AUC) and the peak concentration ($C_{max}$) of nifedipine compared to the control group. The relative bioavailability (RB%) of nifedipine was increased from 1.15- to 1.37-fold. Coadministration of atorvastatin did not significantly change the terminal half-life ($T_{1/2}$) and the time to reach the peak concentration ($T_{max}$) of nifedipine. Based on these results, we can make a conclusion that the significant changes of these pharmacokinetic parameters might be due to atorvastatin, which possesses the potency to inhibit the metabolizing enzyme (CYP3A4) in the liver and intestinal mucosa, and also inhibit the P-glycoprotein (P-gp) efflux pump in the intestinal mucosa. It might be suggested that atorvastatin altered disposition of nifedipine by inhibition of both the first-pass metabolism and P-glycoprotein efflux pump in the small intestine of rats. In conclusion, the presence of atorvastatin significantly enhanced the oral bioavailability of nifedipine, suggesting that concurrent use of atorvastatin with nifedipine should require close monitoring for potential drug interation.

운전기록 모니터링에 의한 발전보일러용 고압 급수가열기 내부 튜브의 파손예측 (Prediction of Internal Tube Bundle Failure in High Pressure Feedwater Heater for a Power Generation Boiler by the Operating Record Monitoring)

  • 김경섭;유호선
    • 플랜트 저널
    • /
    • 제15권2호
    • /
    • pp.56-61
    • /
    • 2019
  • 본 연구에서는 500 MW급 초임계압 석탄 화력발전소의 발전보일러용 고압 급수가열기에서 발생한 내부 튜브의 파손 사례 분석을 통해 운전 기록 모니터링에 의한 발전보일러용 고압 급수가열기 내부 튜브의 파손 예측 방안을 모색하고자 하였다. 이 연구를 통해 고압 급수가열기 내부 튜브 파손 시 쉘 측 수위 조절 밸브 개도와 보일러 급수펌프 흡입 유량의 변화로 내부 튜브 파손을 진단할 수 있는 예측 모형을 제안하였고, 제안된 예측 모형은 급수 계통의 불균형이 일어난 추가 사례를 통해 실증하였다. 이에 따라 본 연구와 유사한 특성의 발전보일러용 고압 급수가열기의 경우에도 쉘 측 수위 조절 밸브 개도와 보일러 급수펌프의 흡입 유량의 정상 운전 상태 값 대비 현재 운전 값 비교는 고압 급수가열기 내부 튜브의 파손에 대한 유력한 예측 진단 방안이 될 수 있다고 판단된다.

공공하수처리시설에서 에너지 사용현황 및 절감방안 연구 (A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant)

  • 김종락;이가희;유광태;김동윤;이호식
    • 한국물환경학회지
    • /
    • 제36권6호
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.

컴팩션 그라우팅 공법의 품질관리 시스템 개발 및 신뢰성 검증 (Development and Reliability Verification of Quality Control System for Compaction Grouting Method)

  • 서석현;이정상;정의엽;박상영;이효범
    • 한국지반신소재학회논문집
    • /
    • 제19권4호
    • /
    • pp.11-20
    • /
    • 2020
  • 본 연구에서는 연약지반의 개량 및 부등침하가 일어난 건물의 복원 등에 사용할 수 있는 컴팩션 그라우팅 공법을 소개하였다. 기존 컴팩션 그라우팅 공법에서 사용되는 펌프는 1공씩 주입하는 시스템으로 시공 효율성이 저하되고,아날로그 주입방식으로 현장 작업자가 수동으로 시공을 관리하여 일관된 품질관리가 어려웠다. 기존 시공에서의 문제점을 해결하기 위하여 펌프와 품질관리 시스템을 개발하였다. 품질관리 시스템은 주입재료의 자동 배합 시스템, 다중 동시 주입 펌프, 주입관리 모니터링 시스템으로 구성하였다. 현장 시험을 통해 품질관리 시스템의 성능을 검증하였고 컴팩션 그라우팅 공법의 시험시공 후 품질 시험을 통하여 지반개량 성능을 확인하였다. 따라서 개발된 통합 품질관리 시스템을 활용한다면 시공 및 품질 확인이 어려운 현장에서 일관된 품질의 보장과 시공의 효율성 및 안정성을 향상시킬 수 있을 것으로 기대된다.

도시지역의 침수저감을 위한 내외수 연계 운영 기법 개발: 목감천 유역을 중심으로 (Combined Inland-River Operation Technique for Reducing Inundation in Urban Area: The Case of Mokgam Drainage Watershed)

  • 권순호;정현우;황윤권;이의훈;김중훈
    • 한국산학기술학회논문지
    • /
    • 제22권1호
    • /
    • pp.257-266
    • /
    • 2021
  • 최근 전 세계적으로 기후변화로 인해 설계빈도를 초과하는 강우가 발생함에 따라 도시 지역의 침수피해가 종종 발생한다. 도시 침수방어 대책으로는 구조적 대책과 비구조적 대책이 있다. 본 연구에서는 비구조적 대책 중에서 내배수 시스템의 운영에 초점을 두었다. 제안 방법인 내외수 연계 운영 방법은 상류 지점에 모니터링 지점을 선정하여 빗물펌프장에 유입되는 유입량을 예측하고, 이를 바탕으로 펌프를 운영하는 방법이다. 본 연구에서는 내외수 연계 운영 기술을 목감천 유역에 적용하였으며, 서울특별시에 큰 침수피해가 발생했던 기왕 강우인 2010년, 2011년 사상을 바탕으로 내외수 연계 운영 방법을 검증하였다. 2010년, 2011년 강우 사상을 적용 결과, 기존 운영 방법대비 침수 저감 효과는 각각 34.9 %, 54.4 % 만큼 감소한 것으로 확인되었다. 즉, 본 연구에서 제안한 내외수 연계 운영 방법은 유수지의 추가 저류공간을 확보함으로써 도시 유역 내에서 침수피해를 최소화했음을 확인하였다. 또한, 집중호우가 많이 발생하는 도시지역에서 침수를 예방하고, 시민의 생명과 재산을 지킬 수 있을 것으로 기대한다.

Is the Diagnostic Trial with Proton Pump Inhibitors Reasonable for School Age Children with Gastroesophageal Reflux Symptoms?

  • Yang, Jaeeun;Lee, Jieon;Lee, Hyunju;Lee, Juyeon;Youn, Young Mee;Choi, Jae Hong;Kim, Yoon-Joo;Kang, Hyun Sik;Han, Kyoung Hee;Kim, Seung Hyo;Kang, Ki-Soo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제22권6호
    • /
    • pp.511-517
    • /
    • 2019
  • Purpose: On the basis of evidence, we aimed to reevaluate the necessity of the empirical proton pump inhibitor (PPI) trial for children with suspected gastroesophageal reflux disease (GERD). Methods: We analyzed the frequency of GERD in 85 school-age children with gastroesophageal reflux (GER) symptoms, who received 24-hour esophageal pH monitoring and/or upper endoscopy. According to the reflux index (RI), the children were classified into normal (RI <5%), intermediate (5%${\leq}$ RI <10%), or abnormal (RI ${\geq}$10%) groups. Results: Fifty six were female and 29 were male. Their mean age was $12.6{\pm}0.5$ (${\pm}$standard deviation) years (range: 6.8-18.6). The RI analysis showed that the normal group included 76 patients (89.4%), the intermediate group included 6 patients (7.1%), and the abnormal group included 3 patients (3.5%). The DeMeester score was $5.93{\pm}4.65$, $14.68{\pm}7.86$ and $40.37{\pm}12.96$ for the normal, intermediate and abnormal group, respectively (p=0.001). The longest reflux time was $5.56{\pm}6.00$ minutes, $9.53{\pm}7.84$ minutes, and $19.46{\pm}8.35$ minutes in the normal, intermediate, and abnormal group, respectively (p=0.031). Endoscopic findings showed reflux esophagitis in 7 patients. On the basis of the Los Angeles Classification of Esophagitis, 5 of these patients were included in group A, 1 patient, in group B and 1 patient, in group C. Conclusion: The incidence of GERD was very low in school-age children with GER symptoms. Therefore, injudicious diagnostic PPI trials would be postponed until the actual prevalence of GERD is verified in future prospective studies.

미캐니컬 씰의 안전운용 감시를 위한 최적 계측인자 (Optimum Monitoring Parameters for the Safety of Mechanical Seals)

  • Soon-Jae Lim;Man-Yong Choi
    • 한국안전학회지
    • /
    • 제12권4호
    • /
    • pp.214-219
    • /
    • 1997
  • 미캐니컬 씰은 회전축에 장착되는 밀봉장치의 하나로써 많은 산업 현장에서 사용되고 있다. 산업발전과 더불어 미캐니컬 씰의 고장 즉, 밀봉장치에서의 누설, 크랙, 파손, 과대마멸 등과 같은 이상 상태는 대규모 공장의 생산라인을 정지시키거나 심각한 환경오염을 유발시키는 등 경제, 사회적 문제를 야기시키고 있다. 미캐니컬 씰 밀봉면의 미끄럼 운동상태를 인지하고, 미캐니컬 씰의 고장에 대한 감시인자를 도출하기 위하여 미끄럼 마멸실험을 수행하였다. 미캐니컬 씰의 회전속도를 1750 rpm 으로 하여, 매 10 분 마다 미캐니컬 씰 밀봉면의 마멸상태를 광학현미경으로 관찰하였고, 실험동안에 미캐니컬 씰의 미끄럼 운동면에서의 음향방출(AE : Acoustic Emission), 토크, 온도, 등을 측정하였으며, 실시간으로 토크 신호의 주파수 분석을 실시하였다. 각 실험의 초기를 제외하고는 전 구간에서 음향방출 신호의 크기와 토크 값의 변화 경향이 대체로 유사한 경향을 보였다. 정상상태에서는 음향방출, 토크 및 온도가 안정된 상태를 유지하였으나, 이상상태에서는 음향방출의 크기와 토크값이 안정된 상태를 유지하지 못하였으며, 온도는 이상상태 때 급상승하는 경향을 보였다. 토크 값과 온도의 변화가 미캐니컬 씰의 고장에 대한 장기적 감시인자로 적절하다고 생각되며, 미캐니컬 씰의 순간적인 이상상태를 확인하거나 미캐니컬 씰의 운동상태를 인지하는 데는 실효치 전압 상태의 음향방출 신호가 적당하다고 생각된다. 온도는 이상상태 감시 시스템에서 시스템의 신뢰도를 증진시키는 병렬요소로써 활용될 수 있을 것이다.장 큰 결합활성도(binding activity)를 나타내며, 또한 Hyphantria cunea와 같은 나비목의 다른 종의 lipophorin도 인식하는 것으로 나타났다. 따라서 리포포린에 결합하는 수용체의 구조적 또는 기능적 요소는 같은 목내의 종간에 보존되는 것으로 생각된다.과 성충의 생존율은 온도에 따른 계통간 차이는 없었다. 내적자연증가율( $r_{m}$ )은 S계통이 $R_{L}$, $R_{F}$계통보다 $25^{\circ}C$에서는 낮았지만 2$0^{\circ}C$와 3$0^{\circ}C$에서는 높았다. 특히 3$0^{\circ}C$에서는 S계통이 현저히 높았다. 결론적으로 dicofol 저항성계통( $R_{L}$, $R_{F}$)은 저온(2$0^{\circ}C$)과 고온(3$0^{\circ}C$)에서 감수성계통에 비해 생물학적 적응력이 떨어질 것으로 생각된다.력이 떨어질 것으로 생각된다.력이 떨어질 것으로 생각된다.해도 될 것이다. 쐐기 투과율을 정하는 위치가 d$_{max}$ 나 공기중이라면 민조사변에 대한 출력계수를 적용할 수 있지만 다른 깊이에서는 쐐기필터 각각에 대한 출력계수를 또는 조사면크기에 따른 쐐기투과율을 적용해야 할 것이다. 39.2%가 이유 설명 후 사주지 않는 것으로 나타났으며 23.2%가 다음으로 미룬다, 무조건

  • PDF