• Title/Summary/Keyword: Pump Control Valve

Search Result 196, Processing Time 0.027 seconds

Development of a Rapeseed Reaping Equipment Attachable to a Conventional Combine (I) - Design and Construction of a Prototype - (보통형 콤바인 부착용 유채 예취장치 개발(I) - 시작기 설계 및 제작 -)

  • Lee, Choung-Keun;Choi, Yong;Jun, Hyun-Jong;Lee, Seung-Kyu;Ryu, Chan-Seok;Kim, Dong-Min
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.371-378
    • /
    • 2008
  • Bio-diesel applications seem to be extended due to bio-diesel policies and changes of agricultural environment. This study was conducted to develop a rapeseed reaping equipment attachable to the conventional combine. This paper was intended to report concept design, process and manufacturing of the prototype rapeseed reaping equipment. For concept design, physical properties of "SUNMANG", which is a typical rapeseed as bio-diesel materials, were considered. The designed prototype rapeseed reaping equipment consisted of wide-width plates, finger type knifes, side cutter knifes and drive equipments. The wide-width plate is 2.1 m wide, 0.7 m long, and 0.002 m thick. The finger type cutter knifes have 14.5 fingers, 30 knifes, and the specification was 7.6 cm of pitch, 8.3 cm of length and $21^{\circ}$ of cutting angle. The side cutter knifes consisted of a hydraulic pump, a hydraulic motor, a flow control and a relief valve, a hydraulic hose, a driving equipment and a reciprocating cutter knife. The 18 reciprocating cutter knifes were 137 cm long and knife pitch, knife length and cutting angle were 7.7 cm, 10.5 cm, and $18^{\circ}$. Prototype weight of the rapeseed reaping equipment was heavier by 272 kg when compared with the manual reaping equipments. Load distributions of left and right side showed 50% and 49%, and those of front and rear side showed 64% and 36%. Static turn-over angles in left and right of the prototype were $38.1^{\circ}$ and $38.7^{\circ}$, respectively. The designed prototype rapeseed reaping equipment was properly mounted at the front of a conventional combine.

Mechanism Diagnosis and Avoidance Design on Transient Acoustic Vibration of Reheater Water Supply Piping in Supercritical Boiler (초임계 보일러 재열기 급수 공급배관의 과도 음향진동 진단 및 회피설계)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Kim, Jae-Won;Lee, Doo-Young;Heo, Hae-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.5
    • /
    • pp.385-393
    • /
    • 2013
  • In this paper, the mechanism identification and the avoidance measures on the phenomena of transient acoustic vibration amplified at the water-supply piping system to regulate the steam temperature of the boiler reheater in 500MW class supercritical power plant are presented. The pressure pulsation waves induced by the impeller passing of two feed-water pumps with five blades are coincident with the local acoustic modes of boiler reheater water-supply piping system. There are the phenomena amplified at the peaks of 5X, 10X, 15X and 20X in spectrums of piping vibration, sound pressure, and the feed-water's pressure pulsation waves. The shut-off device is installed in the piping system for the interception of pressure pulsation waves transmitted from two feed-water pumps and the modified design change of the piping layout is applied for the acoustic resonance avoidance. The acoustic natural frequencies are separated from the harmonics of pressure pulsation waves induced by the pump impellers passing through the design change of the span length. The acoustic vibration is gone by resonance avoidance measures. As a result, more than 20 dBA reduction is achieved from 100 dBA to 80 dBA.

Development of a Non-contact Liquid Dispenser for High Contents Screening System (세포 기반 고집적 스크리닝 시스템용 비접촉식 고정밀 마이크로 디스팬서 제작)

  • Cho, Seong J.;Kim, Intae;Lim, Geunbae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.6
    • /
    • pp.581-585
    • /
    • 2016
  • Nowadays medical treatment service increase due to ageing population and improving the quality of life. Accordingly it is predicted that drug discovery market will expansion continuously. Therefore it is necessary that profit creation by drug discovery on the global market is important. HCS(High Contents Screening) has been emerging as a potential method to solve problems of the present drug discovery. This research is about liquid dispenser for HCS. The purpose of this research is to manufacture high performance liquid dispenser for HCS. The dispenser is designed to control 5 liquids separately. The liquid contact parts are designed disposably, biocompatibly and chemically inertly. Air curtain is equipped at the side of tip to dispense very small liquid volume and to prevent hanging drop on tip. Valving is performed by just controlling the pressure of the pressure driven pump without valve.

Self Production of Radioisotope and Radiopharmaceuticals Divider (방사성동위원소 및 방사성의약품 분주장치의 자체제작)

  • Hong, Sung-Tack;Park, Kwang-Seo;Kim, Seok-Ki;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.177-180
    • /
    • 2010
  • Purpose: As PET test came to be covered by the pay system of medical insurance (July 1, 2006) and the needs for it becoming increased for laboratory purpose, it became necessary to purchase expensive medical equipments to solve those problems. However, as most of equipments that are operated by cyclotron are very expensive as to amount from tens of millions up to hundreds of millions of won, it is difficult to purchase those equipments from the point of medical organizations. It may be possible to self manufacture those equipments with least costs if their parts functions that meets the operators demands. The Nuclear Medicine department of National Cancer Center (NCC) is trying to manufacture and use equipments that can be made with least costs, including introducing 2 medical equipments that can improves the operator's works. Materials and Methods: Example 1: Self production of radioisotope($^{18}F$) divider was fabricated. The NCC's Nuclear Medicine department acquired one acrylic panel, seven 3-way valve, tubing etc. that can be found in the market to make the main body of divider in cooperation with biomedical engineering, and placed them inside hot cell, and installed switching box outside of hot cell to make it possible to control them from outside. This main body of divider were placed in radioisotope transfer line that are manufactured in the cyclotron. Example 2: Self production of $^{18}F$-FDG automated divider was fabricated. The NCC's Nuclear Medicine department used cavro pump syringe that consists the main body of divider in cooperation with biomedical engineering, biomedical engineering developed programs that divides a certain amount. $^{18}F$-FDG automated divider is placed inside hot cell, and cable chords were used in the equipment, and then it was connected to PC outside hot cell to make it possible to control the $^{18}F$-FDG automated divider. Results: From the NCC's Nuclear Medicine department tests that were carried out from March, 2007 until now, we found out that radioisotope can be sent to radiopharmaceuticals composite module we want, and from the tests that are carried out at NCC's Nuclear Medicine department using $^{18}F$-FDG automated divider since August, 2009 it was possible to distribute radiopharmaceuticals into vial intended. Conclusion: Through the two examples above, we found out that costs can be reduced by self manufacturing expensive equipments from NCC's cyclotron room with least costs. Also, it decreased radiation exposure dose on workers, and set up problem solving processes in cooperation with lots of parties related.

  • PDF

Control Algorithm Characteristic Study of Cooling System for Automotive Fuel Cell Application. (차량용 연료전지 냉각시스템 제어 알고리즘 특성 연구)

  • Han, Jae Young;Park, Ji Soo;Yu, Sangseok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.1
    • /
    • pp.39-45
    • /
    • 2016
  • Thermal management of a fuel cell is important to satisfy the requirements of durability and efficiency under varying load conditions. In this study, a linear state feedback controller was designed to maintain the temperature within operating conditions. Due to the nonlinearity of automotive fuel cell system, the state feedback controller results in marginal stable under load condition from $0.5A/cm^2$ to $0.7A/cm^2$. A PWM (Pulse Width Modulation) and the modified state feedback controller are applied to control the temperature under the load condition from $0.5A/cm^2$ to $0.7A/cm^2$. The cooling system model is composed of a reservoir, radiator, bypass valve, fan, and a water pump. The performance of the control algorithm was evaluated in terms of the integral time weighted absolute error (ITAE). Additionally, MATLAB/SIMULINK$^{(R)}$ was used for the development of the system models and controllers. The modified state feedback controller was found to be more effective for controlling temperature than other algorithms when tested under low load conditions.

Study on Developing Assessment Guideline for Safety and Performance of Electric Cupping Apparatus (전동식 부항기에 대한 안전성 및 성능평가 가이드라인 개발연구)

  • Yi, Seung-Ho;Kim, Eun-Jung;Shin, Kyung-Hoon;Nam, Dong-Woo;Kang, Jung-Won;Lee, Seung-Deok;Lee, Hye-Jung;Lee, Jae-Dong;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.26 no.6
    • /
    • pp.101-110
    • /
    • 2009
  • Objectives : We developed and proposed a guideline for safety and performance assessment of electric cupping apparatus(Class 2 medical device). Methods : We drafted the guideline for safety and performance assessment of electric cupping apparatus by referring the existing standards and guideline, based on online questionnaire for Korean medical doctors and measurement data from commercially available products. Physical dimension of cups and inner vacuum pressure were acquired for the measurement in order to achieve the purposes. Results : This guideline only can be applied to electric cupping apparatus for enhancing blood circulation by employing negative pressure generated by electricity. Seven items of appearance and label, operation test of pump, variation test of input electricity, vacuum level test, vacuum sustain test, cup-size dependent test, noise level test are suggested for evaluation subjects and methods required for electric cupping devices. Requirements for the design and development of electric cupping devices are suggested: vacuum level indicator, vacuum generation rate, pressure control, valve detachment stability, cup comparability, safety measure, surge protection, user friendliness, instruction for use (IFU). Conclusions : We proposed a guideline for safety and performance assessment of electric cupping apparatus to improve the quality of relating products and aid the commercialization of them, by aiming higher industrial competitiveness of the medical device sectors in Korea. Discussion with related institutes such as industry, academy and government is further required. Public hearings also need to be held prior to the establishment of a final guideline and standard.

  • PDF