• Title/Summary/Keyword: Pulsed-CW

Search Result 47, Processing Time 0.026 seconds

Position Estimation of Underwater Acoustic Source Using Pulsed CW Signal (Pulsed CW 신호를 사용하는 수중 음원의 위치 추정을 위한 시간지연차 추정법)

  • 최영근;손권;도경철;김기만
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.7
    • /
    • pp.514-520
    • /
    • 2004
  • There are many techniques for underwater source localization. These are the methods based on TDOA (Time Difference Of Arrival) estimation. beamforming techniques and high resolution techniques, etc. In this Paper we estimate the underwater source position using MCPSP (Modified Cross Power Spectrum Phase) function that is calculated on frequency domain using sensors of small number. However, the performances of the localizing method based on MCPSP function drops greatly in the case of CW (Continuous Wave) signal . In this Paper we proposed the TDOA estimation method for pulsed CW signal. In the Proposed method we composed of new segment including a edge of ping. This segment was computed by short-time energy detection. With theoretical representation the performances of the proposed method were analyzed under various environment.

Performance Comparison of Radar Signal Active Cancellation Systems According to Pulsed-CW Parameter Estimation Error (Pulsed-CW 신호 파라미터 추정 오차에 따른 레이더 신호 능동 상쇄 성능 비교)

  • Choi, Seung-Kyu;Lee, Chung-Yong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.10
    • /
    • pp.60-66
    • /
    • 2011
  • In this paper, we analyze the effects of estimation error in the active cancellation signal, which is intended to counter the pulsed-CW signal of a hostile radar. We also examine the effects of estimation error in maximum-likelihood estimation (MLE) and quadratic interpolation scheme from a radar signal active cancellation viewpoint. Then, we modify the correlation-based error compensation scheme which mitigates the estimation error of MLE to improve the performance of the active cancellation signal. Finally, we present simulation results to show that the correlation-based scheme has better performance than the other in terms of radar signal active cancellation.

Imaging Technique Based on Continuous Terahertz Waves for Nondestructive Inspection (비파괴검사를 위한 연속형 테라헤르츠 파 기반의 영상화 기술)

  • Oh, Gyung-Hwan;Kim, Hak-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.328-334
    • /
    • 2018
  • The paper reviews an improved continuous-wave (CW) terahertz (THz) imaging system developed for nondestructive inspection, such as CW-THz quasi-time-domain spectroscopy (QTDS) and interferometry. First, a comparison between CW and pulsed THz imaging systems is reported. The CW-THz imaging system is a simple, fast, compact, and relatively low-cost system. However, it only provides intensity data, without depth and frequency- or time-domain information. The pulsed THz imaging system yields a broader range of information, but it is expensive because of the femtosecond laser. Recently, to overcome the drawbacks of CW-THz imaging systems, many studies have been conducted, including a study on the QTDS system. In this system, an optical delay line is added to the optical arm leading to the detector. Another system studied is a CW-THz interferometric imaging system, which combines the CW-THz imaging system and far-infrared interferometer system. These systems commonly obtain depth information despite the CW-THz system. Reportedly, these systems can be successfully applied to fields where pulsed THz is used. Lastly, the applicability of these systems for nondestructive inspection was confirmed.

CW 및 Pulsed 레이져를 이용한 세라믹 절단

  • 방세윤
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.156-160
    • /
    • 1994
  • Use of engineering ceramics has been increasing due to the outstanding physical and chemical properties. Conventional machining processes, however, are not applicable due to their hardness and brittleness. Laser cutting is a promising alternative for these ceramics. In this study, experimental data of CO $_{2}$ laser cutting of $Al_{2}$ $O_{3}$ and Si $_{3}$ N $_{4}$ are obtained to give a guide in the industry. Results of $Al_{2}$ $O_{3}$ cutting showed extreme weakness to thermal crack and it was found that pulsed beam has to be used for thick $Al_{2}$ $O_{3}$ specimen. Si $_{3}$ N $_{4}$ showed good results for both CW and pulsed beams. Using pulsed beam resulted narrower kerf width with increased surface roughness a nd reduced cutting speed. It was also found that a parameter call path energy is useful for representing minimum threshold value for possible cutting range with pulsed beam.

  • PDF

A Study on Ultrasound Pulsed Doppler Systems for Sending the Blood Flow (혈류 진단을 위한 초음파 펄스 도플러 시스템에 관한 연구)

  • Kim, Seong-Ryul;Kim, Jin-Ha;Park, Song-Bae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.5
    • /
    • pp.33-40
    • /
    • 1984
  • In the conventional pulsed doppler system, gated CW is used to excite a ultrasonic transducer so that a group of linear RF amplifiers are required to excite a ultrasonic array transducer in the scanning pulsed doppler system. A pulsed doppler system without linear high voltage RF amplifiers, which excites the transducer impulsively, is studied theoretically and experimentally. In this paper, an experimental 8-channel pulsed doppler system is implemented, which uses quadrature defection to detect the direction of motion and can compensate the attenuation effect. The designed pulsed doppler system shows the possibility of real time multichannel doppler flow meter.

  • PDF

Study of frequency chirping of pulse amplified laser beam by using heterodyne method (헤테로다인 방법을 이용한 펄스 증폭된 레이저빔의 주파수 Chirping연구)

  • 김진태
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.1
    • /
    • pp.70-72
    • /
    • 2002
  • Amplified pulsed laser beam with narrow linewidth was generated from CW laser beam with narrow linewidth by using frequency doubled Nd:YAG laser beam and Bethune cell. The degree of the frequency chirping of the amplified pulse laser was measured by using the heterodyne method and obtained by calculating instantaneous phase change from heterodyne beating signals. The frequency chirping of amplified pulsed laser beam from CW laser beam with sub-MHz linewidth by 10 ns pulse was 80 MHz so that pulsed laser beam with very narrow linewidth was obtained.

Quantitative Evaluation on Laser Performance for Endovenous Photocoagulation (레이저를 이용한 하지정맥류 치료의 정량화 연구)

  • Ahn, Minwoo;Nguyen, Van Phuc;Oh, Junghwan;Kang, Hyun Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.3
    • /
    • pp.62-67
    • /
    • 2014
  • The purpose of the study was to identify the effect of laser parameters on photocoagulation to maximize safety and efficacy during varicose vein treatment. CW and pulsed modes at 1470 nm were initially compared as a function of power on bovine liver tissue. In the pulsed mode, various parameters including repetition rate, duty cycle, and irradiation time were compared to evaluate tissue response during thermal treatment. The results demonstrated that CW and pulsed modes yielded almost similar coagulation development possibly due to shorter irradiation time of 5 sec. Regardless of laser mode, both repetition rate and duty cycle presented constant coagulation rate whereas longer irradiation time facilitated coagulation process.

Single Longitudinal Mode Operation of a Pulsed Dye Laser Injection-seeded with a CW Ring Dye Laser (인젝션 록킹 방법에 의한 펄스 색소레이저의 단일 종모우드 발진)

  • 김재완;공홍진;한재원;박승남
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.84-89
    • /
    • 1994
  • A tunable pulsed dye laser was operated in a single longitudinal mode by injection locking with a cw ring dye laser. A doubled Nd:YAG laser was used as the pumping source. Phase sensitive detection technique was applied to maintain the required match between the master laser frequency and the slave resonator cavity length. The fluctuation of the center frequency of the pulsed laser was < 10 MHz, and the pulse duration (FWHM) was 6 ns. The linewidth measured by scanning confocal interferometer was 130 MHz. When pumped by 50 mJ of the doubled Nd:YAG laser, the output energy of the pulsed dye laser was 2 mJ and the peak power was 330 kW. 30 kW.

  • PDF

$CO_2$ Laser Absorption Measurement of $CH_3CH_2Br$ using Photoacoustic Method

  • Jang Soo Shin;Kyung Hoon Jung;Cheol Jung Kim
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.5
    • /
    • pp.553-556
    • /
    • 1992
  • The ${CO}_2$ laser absorption measurement of ${CH}_3{CH}_2Br$ utilizing photoacoustic (PA) technique was performed using a cw and a pulsed ${CO}_2$ lasers. The absorption profile in the ${CO}_2$ laser wavelength region (9-10 ${\mu}$m) and the macroscopic small signal absorption cross section at 10P(20) (10.59 ${\mu}$m, 944 $cm^{-1}$) laser line were measured using a cw ${CO}_2$ laser. The laser fluence dependence on infrared multiphoton absorption (IRMPA) was also studied with a pulsed TEA ${CO}_2$ laser at 10P(20) laser line. In view of monotonic increase of PA signal with the rise of laser fluence, it was suggested that the anharmonicity in pumped vibration mode did not restrict ir multiphoton absorption in ${CH}_3{CH}_2Br$ system as found in large molecular system.

Quenching rate controlled Laser Annealing (QLA) for poly-Si TFT fabrication

  • Han, Gyoo-W.;Alexander, Voronov;Ryu, S.G.;Kim, H.S.;Roh, C.L.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.897-897
    • /
    • 2005
  • We report QLA (Quenching-rate controlled Laser Annealing) system as new concept using pulsed DPSSL and CW lasers. This process can control temperature quenching-rate of poly-Si crystallization by additional CW laser and fabricate high quality poly-Si with faster scanning speed than conventional processes. In this paper, QLA system, the experimental results and theoretical discussion will be introduced.

  • PDF