• Title/Summary/Keyword: Pulsed power

Search Result 588, Processing Time 0.031 seconds

The design of adaptive Controller for the Voltage Bus Conditioner for the improvement of the Power Quality in the DC Power Distribution System (DC 배전시스템의 품질향상을 위한 VBC 적응제어)

  • Woo, Hyun-Min;Lee, Byung-Hun;Chang, Han-Sol;La, Jae-Du;Kim, Young-Seok
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2348-2356
    • /
    • 2011
  • In recent years, many researches for DC power distributed system (PDS) are being preformed and the importance of the DC PDS is more and more emphasized. Furthermore, in the railway system, the DC PDS is used in subway station lighting, facilities, etc. In the DC PDS, DC bus voltage instability may be occurred by the operation of multiple parallel loads such as pulsed power load, motor drive system, and constant power loads. Thus, good quality and high reliability for electric power are required and voltage bus conditioner (VBC) may be used the DC PDS. The VBC is a DC/DC converter for mitigation of the bus transients. In this paper, adaptive controller is designed. The simulation results by PSIM are presented for validating the proposed control algorithm.

  • PDF

Control of 3 - Phase 4 - Wire Isolated Grids

  • Buttner Jurgen;Ellinger Thomas;Muller Andre;Petzoldt Jurgen
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.816-821
    • /
    • 2001
  • The generation of isolated grids by pulsed converters with characteristics close to the mains of the utility companies is a pretentious task. For generation of three-phase four-wire isolated grids are presented possible topologies and the demands on the system control are processed. For control of all conceivable load and error conditions, an extensive control technology is necessary. This must permit unsymmetrical operating conditions for an unlimited period but recognize errors simultaneously and therefore an overloading the consumer and the power semiconductors reliable may prevent. Measurement results on an experimental plant show the problems to be solved.

  • PDF

Study on the High and High Voltage 35 kW, 50 kV Inverter Power Supply (대출력 고전압 35 kW, 50 kV 인버터 전원장치 개발에 관한 연구)

  • Son, Yoon-Gyu;Jang, Sung-Duck;Oh, Jong-Seok;Cho, Moo-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.11
    • /
    • pp.628-634
    • /
    • 2002
  • A capacitor-charging power supply using high frequency inverter technology is strongly recommended for the charging section of the pulsed power supplies. A high frequency inverter swiching makes the overall system size small. The command-charging feature can guarantee the higher reliability of switching function. The protection circuit can be easily included in the system and the good regulation of charging voltage can be acieved by the feedback system. Several modules can be stacked to supply required output power and a failed module can be easily replaced. A 50-kV, 35-kW capacitor charging power supply is developed. In this paper the detailed design and test results of a prototype unit are presented.

Effect of a Pulsed Nd:YAG laser irradiation on human gingival tissues (파동형 Nd:YAG 레이저조사가 인체 치은조직에 미치는 영향)

  • Kang, Kyung-Dong;Kim, Chun-Suk;Kim, Hyung-Soo;Kim, Hyun-Seop;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.4
    • /
    • pp.989-1002
    • /
    • 1996
  • The purpose of this study was to determine the effect of a pulsed Nd:YAG laser irradiation on human gingival tissues. The patients, who were planned to be treated by clinical crown lengthening procedure and gingivectomy, were selected. All the patients received oral hygiene instruction, scaling and root planing at preoperation. The crest of gingival tissue on upper and lower anterior teeth was irradiated by a pulsed Nd:YAG laser(El. EN. EN060, Italy) with a fiber optic of 300 m in contact mode for 20 seconds. Gingival tissues were divided into 4 groups according to the laser power of 1.0W(10Hz, 100mJ), 2.0W(20Hz, 100mJ), 3.0W(30Hz, 100mJ) and 4.0W(40Hz, 100mJ). Immediately after the laser irradiation, the specimens were excised, fixed 10% neutral formalin, sectioned $4-6{\mu}m$ thick, stained by Hematoxylin-Eosin and Periodic Acid Schiff stain and observed under light microscope. The removed tissue depth and the coagulated layer depth due to a laser irradiation by a laser irradiation were measured on the microphotographs. The difference of measurements according to the different laser power was statistical1y analyzed by Kruskal Wallis Test with SAS program. The results were as follows : 1. In histologic findings of irradiated gingival tissues; a. In the irradiated gingival specimen with 1.0W laser power, some vesicles were observed in limited superficial layer of gingival epithelium. b. In the irradiated gingival specimen with 2.0W and 3.0W laser power, the epithelium was almost removed except for the traces of viable basal cell remnants at ret peg, and coagulation necrosis related with the thermal effect of laser was noted. c. In the irradiated gingival specimen with 4.0W laser power, complete removal of epithelium, partial removal of underlying connective tissue, and the coagulation necrosis of subjacent gingival tissue were shown. 2. The removed tissue depth was deeper in the irradiated specimens with higher power. There was a statistical significance in the difference of removed tissue depth between 1.0W group ($44.54{\pm}6.99um$) and 3.0W group ($99.75{\pm}6.64{\mu}m$), and between 1.0W group($44.54{\pm}6.99{\mu}m$) and 4.0W group($111.36{\pm}4.50{\mu}m$), and between 2.0W group($98.01{\pm}4.53{\mu}m$) and 4.0W group($111.36{\pm}4.50{\mu}m$)(P<0.05). 3. The coagulated layer depth was deeper in the irradiated specimens with higher power. There was a statistical significance in the difference of coagulated layer depth between 1.0W group($31.82{\pm}8.99{\mu}m$) and 3.0W group($55.99{\pm}20.94{\mu}m$), and between 1.0W group($31.82{\pm}8.99{\mu}m$) and 4.0W group($83.68{\pm}10.34{\mu}m$)(P<0.05). From this study, the results demonstrated that the effects of a pulsed Nd:YAG laser irradiation on gingival tissues seemed to depend on the laser power and that the irradiation with high power could be harmful to adjacent healthy tissue.

  • PDF

AlGaN/GaN-on-Si Power FET with Mo/Au Gate

  • Kim, Hyun-Seop;Jang, Won-Ho;Han, Sang-Woo;Kim, Hyungtak;Cho, Chun-Hyung;Oh, Jungwoo;Cha, Ho-Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.2
    • /
    • pp.204-209
    • /
    • 2017
  • We have investigated a Mo/Au gate scheme for use in AlGaN/GaN-on-Si HFETs. AlGaN/GaN-on-Si HFETs were fabricated with Ni/Au or Mo/Au gates and their electrical characteristics were compared after thermal stress tests. While insignificant difference was observed in DC characteristics, the Mo/Au gate device exhibited lower on-resistance with superior pulsed characteristics in comparison with the Ni/Au gate device.

A Study on Inverter Arc Welder for Energy Saving in Power Station (발전소용 인버터에 의한 절전형 아크용접기에 관한 연구)

  • 윤병도;정재윤;김찬기;이병송
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.2
    • /
    • pp.85-93
    • /
    • 1994
  • In this paper, the welding characteristics of inverter arc welder for energy saving is presented. OC arc, pulsed arc and high-frequency arc are compared on the basis of welding characteristics and energy saving. Especially, Superposition of pulsed arc and high-frequency arc is researched. According to the simulation and experimental result, Superposition method is superior to ohters in the aspect of energy saving and welding characteristics without defect.

  • PDF

Surface Hardening Characteristics of SK5 Steel by Pulsed YAG LASER (YAG 레이저에 의한 SK5 표면경화 특성)

  • 강형식;문종현;전태옥;박홍식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.921-924
    • /
    • 1995
  • Case hardening behavior of carbon tool steel(SK5) was investigated after pulsed YAG laser irradiation. In the case od beam passes,martensite formed in the melt zone and in former pearlite regions of the austenitization zone exhibits vary high Vickers hardness values. The molten depth and width decrease as the beam power density increase. The influence of depth and width of color painted specimen was also investigated. The molten zone of the black painted specimen was the largest. The were loss of the black painted specimen was smaller than any other painted or raw material.

  • PDF

Shear Strength of lnconel Tube Welded with Pulsed Nd:YAG Laser (펄스형 Nd:YAG레이저로 용접된 Inconel Tube의 전단강도)

  • Chang, W.;Kim, J. D.;Chung, J. M.;Kim, C. J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.125-128
    • /
    • 1995
  • The remote sleeve repair-welding technology using the pulsed Nd:YAG laser for increasing the lifetime of the steam generator tube in the nuclear power plant has been developed. The laser welding has many advantages on deep penetration depth and narrow heat affect zone(HAZ). The inconel 600 tube and inconel 690 sleeve used high temperature and high pressure service have been welded as round lap welds. It is found that the relation between the connection width and welding parameters. It is found that the shear strength in proportion to the connection width by conducting tensile-shear tests.

  • PDF

Discharge Processes of NO Gas Using Bidirectional Pulsed Voltage (양방향 펄스전원을 이용한 NO 가스의 방전처리)

  • Ju, Heung-Jin;Park, Jeong-Ho;Shim, Jae-Hak;Ko, Kwang-Cheol;Kang, Hyung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1682-1684
    • /
    • 2001
  • In removing the flue-gas using electrical discharge method, it is important to dissociate or ionize the atoms and molecules by the collisions with energetic electrons and it produces the radicals that are used to decompose the pollutants. For that purpose, a bidirectional pulsed voltage is used to produce lots of energetic electrons efficiently and increase the power efficiency. The simulation is performed with changing the pulsewidth under the fixed applied voltage. The particle-mesh model coupling the NGP(nearest-grid-point) to FEM(finite element method) is used to simulate the behavior of electrons and the spatio-temporal variation of the electric field for the streamer in discharge tube.

  • PDF

Auto-focus Control by Chromatic Filtering in Laser Welding

  • Kim, Cheol-Jung;Baik, Sung-Hoon;Kim, Min-Suk;Chung, Chin-Man;Kim, Kwang-Jung
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.94-99
    • /
    • 2000
  • Optical monitoring using the chromatic aberration of focusing optics is applied to auto-focus control in laser welding. The spectral transmittance of thermal radiation from a weld pool through an aperture depends on the wavelength of the spectral band and on the distance of the weld pool from the focusing optics. Its dependence has been used to monitor the focus shift in laser welding by measuring the spectral band signals filtered by the aperture. The difference between pulsed and continuous laser welding is analyzed. Furthermore, the dependence of the focus shift monitoring on the weld pool size variation is optimized to monitor the focus shift independently from the laser power change at the weld pool. The performance of the auto-focus control with chromatic filtering is presented for pulsed laser welding.