• Title/Summary/Keyword: Pulsed power

검색결과 588건 처리시간 0.034초

황색포도구균과 대장균의 기준형별 결정에 있어서 Infrequent Restriction Site Polymerase Chain Reaction과 Pulsed-Field Gel Electrophoresis의 변별력 비교 (Comparison of Infrequent Restriction Site-Polymerase Chain Reaction and Pulsed-Field Gel Electrophoresis for Molecular Typing of Staphylococcus aureus and Escherichia coli)

  • 신완식;김태규;최정현;이동건;최희백;유진홍;김종현;강진한;민우성
    • 대한미생물학회지
    • /
    • 제35권4호
    • /
    • pp.289-297
    • /
    • 2000
  • Background: Staphylococcus aureus (s. aureus) and Escherichia coli (E. coli) are major pathogens in community and hospital. And they sometimes cause the outbreak in hospital in the immunocompromised patients. Pulsed-field gel electrophoresis (PFGE) has been regarded as a standard method for genotyping in epidemiologic studies, but it is laborious and time-consuming. Infrequent restriction site-polymerase chain reaction (IRS-PCR), a new genotyping methods, was performed to compare the applicability with PFGE. Methods: We performed PFGE and IRS-PCR on S. aurues (n=120) and E. coli (n=117) which were collected clinically in 4 different hospitals. We assessed each method in terms of discriminatory power, quality, and efficiency. Results: In E. coli, the discriminatory power of IRS-PCR was $46.7{\sim}86.7%$, and that of PFGE was $88.9{\sim}96.7%$ according to hospital. But in S. aurues, the discriminatory power of IRS-PCR was $20{\sim}56.7%$, and that of PFGE was $40{\sim}90%$ according to hospital. The typablity and reproducibility of IRS-PCR were 100% of each. PFGE needed four days to complete the procedure, but IRS-PCR could be performed within one day, IRS-PCR showed better resolution than PFGE. Conclusion: In case of gram negative bacteria (like E. coli), IRS-PCR could be a reliable alternative for epidemiologic typing due to better efficiency and comparable discriminatory power. But in the case of gram positive bacteria (like S. aureus), IRS-PCR does not seem to be suitable for the strain-to-strain differentiation. More trials and changes of restriction enzymes or primers could reveal the efficacy of IRS-PCR in the field of molecular typing.

  • PDF

구강내 연조직에 대한 무통적조사를 위한 Nd:YAG laser의 출력조절에 관한 임상적 연구 (A clinical study of the power control of Nd : YAG laser for painless irradiation on intraoral soft tissues)

  • 한상학;김현섭;임기정;김병옥;한경윤
    • Journal of Periodontal and Implant Science
    • /
    • 제26권2호
    • /
    • pp.522-530
    • /
    • 1996
  • Most dentists are very interested in laser therapy on the intraoral soft tissue lesions because they want to accomplish the analgesic and aseptic surgery with little or no bleeding. In order to determine the difference of pain threshold according to different gingival tissues with or without inflammation, 25 patients with inflammatory periodontal disease and 10 volunteers with good general and oral health were selected as the inflamed group and the normal group, respectively. Interdental papilla, marginal gingiva, attached gingiva, and alveolar mucosa were irradiated by the contact delivery($300{\mu]m$ fiber optic, for 5 seconds) of a pulsed Nd:YAG laser(EN.EL.EN06O, Italy). And the laser power was gradually increased from 0.5W by the increment of 0.1W. The highest laser power was recorded as the first painful power when the painful gesture was recognized at first. The difference of the first painful power of laser according to different gingival tissues with or without inflammation was statistically analyzed by paired t-test in MICROSTAT program. Following results were obtained: 1. In the comparison related with the inflammation, the first painful power was significantly lower in the inflamed group than in the normal group, regardless of interdental papilla and marginal gingiva(p<0.05). 2. In the comparison related with the tissue structure, the first painful. power was significantly lower in alveolar mucosa than in attached gingiva(p<0.05). The results suggest that, for the painless therapy by a pulsed-Nd:YAG laser irradiation, the laser surgery over 2.0W of power should be necessarily accomplished under the local anethesia, and the local anesthesia should be considered according to the degree of inflammation, the tissue structure, and the purpose of laser therapy.

  • PDF

연소가스내 탈황탈질처리를 위한 저온 플라즈마 기술 (Non-Thermal Plasma Technique for Removing $SO_2$ and $NO_x$ from Combustion Flue Gas)

  • 송영훈;신완호;김석준;장길홍
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1997년도 제15회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.69-76
    • /
    • 1997
  • Industrial-scale pulse corona process to remove $SO_2$ and $NO_x$ simultaneously from combustion flue gas has been studied. The pilot plant built in the present study treats 2,000 $Nm^3$/hr of flue gas from a boiler. The geometry of the pulse corona reactor is similar to that of an electrostatic precipitator commonly used in industry, A thyratron switch and magnetic pulse compressors, which can generate up to 130 kV of peak pulse voltage and up to 30 kW of average pulse power, have been used to produce pulsed corona. The removal efficiencies of $S0_2$ and $NO_x$ with the present process are maximum of 95 % and 85 %, respectively. Electrical power consumption to produce the pulsed corona, which has been one of the major difficulties to apply this process to industry, has been evaluated in the present study. The results showed that the power consumption can be reduced significantly by simultaneous addition of hydrocarbon injection and heterogeneous phase reactions to the process.

  • PDF

펄스파워 시스템용 고전압 펄스변압기의 EMTP 시뮬레이션 (A EMTP Simulation of High-Voltage Pulse Transformer for Pulsed Power System)

  • 김민수;이형구;주홍진;고광철;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1984-1986
    • /
    • 2000
  • In pulsed-power techniques. Marx generator is generally used for the high-power device. but this generator has insulation and spatial problems. So we will suggest a pulse transformer that has a small size to generate the high voltage pulse instead of Marx generator. In this paper, Pulse duration is 4 [${\mu}s$] and the ratio of input and output voltage is 40[kV]/200[kV](step-up ratio=5). The output voltage and the process of pulse compression for pulse circuit are simulated by EMTP (Electro-Magnetic Transient Program). The secondary voltage of pulse transformer is about 200[kV] and pulse width is 4[t/s]. When the secondary winding of the pulse transformer is saturated. the pulse width is 1.25[${\mu}s$]. We selected dummy load 50[$\Omega$] for impedance matching. The pulse voltage of dummy load is 100[kV] and pulse width is 500[ns].

  • PDF

대 출력 발생장치의 지파불안정성 연구 (A Study of Slow Wave Instability on High Power Generator)

  • 김원섭;김종만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2109-2109
    • /
    • 2011
  • High power microwave sources operating in relativistic regions, high current reletivistic electron beams are obtained by using cold cathodes with the help of explosive emission. For these relativistic devices, the pulsed power and magnetic field systems are very large and heavy. The phase velocity of electromagnetic mode should be showed down close to the beam velocity, ensuring enough beam coupling with electromagnetic modes. By using the annular electron beam, a weakly relativistic oversized bwo consisting of rectangularly corrugated cylindrical waveguide is demonstrated.

  • PDF

대 전력 전자빔 발생 초기 전류에 대한 연구 (A Study of Starting Current High Power Electron Beam Production)

  • 김원섭
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.268-271
    • /
    • 2006
  • We have studied the backward wave oscillator, a power-pulsed generator oscillator at 20 GHz has higher frequency then current one. An absolute instability linear analysis was used for the purpose of designing the slow wave structure. A large diameter of the slow wave structure was adopted to prevent the breakdown brought about by the increase of power density.

  • PDF

Pulsed Nd ; YGA 레이저의 치수마취효과에 관한 연구 (A STUDY OF ANALGESIC EFFECT ON PULP INDUCED BY PULSED Nd : YAG LASER)

  • 김도형;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제24권1호
    • /
    • pp.301-312
    • /
    • 1997
  • The purpose of this study was to evaluate the analgesic effect on pulp induced by pulsed Nd : YAG laser according to the power density, irradiated time and the method of application (Non-contact vs contact) in vivo. Experiments were carried out on 90 volunteers who have sound 4 canines. Each canine was grouped by the intensity and the time of irradiation of pulsed Nd : YAG laser was measured. Mean EPT response(units) was measured at 5 min, 30 min, and 60 min after irradiation with various intensity(1.5-3W, 15-30Hz), irradiated time (1.5min, 3min), and application method (Non-contact and contact). The results were as follows: 1. 5 minutes after irradiation, the mean EPT response(units) was increased by 32 % in the non-contact method and by 35% in the contact method of application. Which showed significant difference in mean EPT response(units) compared to not-lased canine in each groups(P<0.05). 2. The mean EPT response(units) with irradiating condition according to the various laser intensity, and the irradiation time stastically did not show significant difference in each groups as time elapsed. 3. There was no significant difference between the non-contact and contact method in the mean EPT response(units). 4. The mean EPT response(units) returned to the baseline value within 30 miuntes. In regard to the above results, the analgesic effect on pulp induced by pulsed Nd : YAG laser resulted a slight increase of pulpal pain threshold, but it was not as high as to replace the role of drug analgesia as whole. This technique can be used for inducing pulpal analgesia as adjunct to other pain control methods and is needed to develop better analgesic effects.

  • PDF

계단 주파수 변조된 펄스 도플러 기법을 이용한 고해상도 전방 충돌 회피용 차량 레이다 성능 분석 (High Resolution Forward-Looking Collision Avoidance Automotive Radar Using Stepped-Frequency Pulsed-Doppler(SFPD) Technique)

  • 우성철;곽영길
    • 한국전자파학회논문지
    • /
    • 제20권8호
    • /
    • pp.784-790
    • /
    • 2009
  • 전방 감시 차량용 레이다에서 표적 거리와 속도 정보를 얻기 위해서는 일반적으로 주파수 변조된 연속파형(FMCW)이나 펄스 도플러(PD) 파형을 사용하고 있다. 그러나 고해상도의 표적 정보를 얻기 위해서는 펄스 폭이 매우 좁고 넓은 대역폭을 사용하여야 하므로 상대적으로 높은 첨두 전력이 필요하고 고속의 디지털 변환 처리속도가 요구된다. 본 논문에서는 계단 주파수 변조된 펄스 도들러 파형을 이용하여 고해상도의 표적 정보를 획득할 수 있는 SFPD(Stepped-frequency Pulsed-Doppler) 처리 기법을 제시한다. 제안된 SFPD 기법은 시뮬레이션을 통하여 기존의 FMCW 및 펄스 도플러 파형 방식과 비교 분석하였다. 본 기법은 필요에 따라서 거리 및 도플러 해상도를 가변할 수 있는 장점이 있기 때문에 이론적으로 고해상도의 표적 영상 형성이 가능하여 향후 정밀한 차량 충돌 방지를 위한 표적 식별에 활용할 수 있을 것으로 기대한다.

Diamond-Like Carbon Films Deposited by Pulsed Magnetron Sputtering System with Rotating Cathode

  • Chun, Hui-Gon;You, Yong-Zoo;Nikolay S. Sochugov;Sergey V. Rabotkin
    • 한국표면공학회지
    • /
    • 제36권4호
    • /
    • pp.296-300
    • /
    • 2003
  • Extended cylindrical magnetron sputtering system with rotating 600-mm long and 90-mm diameter graphite cathode and pulsed power supply voltage generator were developed and fabricated. Time-dependent Langmuir probe characteristics as well as carbon films thickness were measured. It was shown that ratio of ions flux to carbon atoms flux for pulsed magnetron discharge mode was equal to $\Phi_{i}$ $\Phi$sub C/ = 0.2. It did not depend on the discharge current in the range of $I_{d}$ / = 10∼60 A since both the plasma density and the film deposition rate were found approximately proportional to the discharge current. In spite of this fact carbon film structure was found to be strongly dependent on the discharge current. Grain size increased from 100 nm at $I_{d}$ = 10∼20 A to 500 nm at $I_{d}$ = 40∼60 A. To deposit fine-grained hard nanocrystalline or amorphous carbon coating current regime with $I_{d}$ = 20 A was chosen. Pulsed negative bias voltage ($\tau$= 40 ${\mu}\textrm{s}$, $U_{b}$ = 0∼10 ㎸) synchronized with magnetron discharge pulses was applied to a substrate and voltage of $U_{b}$ = 3.4 ㎸ was shown to be optimum for a hard carbon film deposition. Lower voltages were not sufficient for amorphization of a growing graphite film, while higher voltages led to excessive ion bombardment and effects of recrystalization and graphitization.

0.25 μm AlGaN/GaN HEMT 소자 및 9 GHz 대역 전력증폭기 (0.25 μm AlGaN/GaN HEMT Devices and 9 GHz Power Amplifier)

  • 강동민;민병규;이종민;윤형섭;김성일;안호균;김동영;김해천;임종원;남은수
    • 한국전자파학회논문지
    • /
    • 제27권1호
    • /
    • pp.76-79
    • /
    • 2016
  • 본 논문에서는 ETRI에서 개발된 50 W GaN-on-SiC HEMT 소자를 이용하여 X-band에서 동작하는 50 W 펄스 전력증폭기의 개발 결과를 정리하였다. 제작된 50 W GaN HEMT 소자는 $0.25{\mu}m$의 게이트 길이를 갖고, 총 게이트 폭은 12 mm인 소자이다. 펄스 전력증폭기는 9.2~9.5 GHz 주파수 대역에서 50 W의 출력전력과 6 dB의 전력이득 특성을 나타내었다. 전력소자의 전력밀도는 4.16 W/mm이다. 제작된 GaN-on-SiC HEMT 소자와 전력증폭기는 X-대역 레이더 시스템 등 다양한 응용분야에 적용이 가능할 것으로 판단된다.